[an error occurred while processing this directive]
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
GIRAFFE trending system: FULL report
HELP USERS-GUIDE MORE
Last update: 2025-12-18T16:41:02 (UT)
  | now: 2025-12-18T17:54:48 (UT) muc02 QC pipeline: giraf-2.16.14 (installed 2024-10-16)
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Marked green: ETC values.
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB none   fraction none  37 mean_effic all (full time range) HR efficiencies vs. wavelength (Argus, HR grating); old CCD
2 QC1DB none   fraction none  37 mean_effic all (full time range) LR efficiencies vs. wavelength (Argus, LR grating); old CCD
3 QC1DB none   fraction none  706 mean_effic all (full time range) HR efficiencies vs. wavelength (Argus, HR grating); new CCD
4 QC1DB none   fraction none  877 mean_effic all (full time range) LR efficiencies vs. wavelength (Argus, LR grating); new CCD
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:giraffe_std
(QC1 database)
dataset:mean_effic
average:none
thresholds:none
N_data plotted:37
[click plot for closeup]
Plot 2
scores: not implemented
data source:giraffe_std
(QC1 database)
dataset:mean_effic
average:none
thresholds:none
N_data plotted:37
[click plot for closeup]
Plot 3
scores: not implemented
data source:giraffe_std
(QC1 database)
dataset:mean_effic
average:none
thresholds:none
N_data plotted:706
[click plot for closeup]
Plot 4
scores: not implemented
data source:giraffe_std
(QC1 database)
dataset:mean_effic
average:none
thresholds:none
N_data plotted:877
[click plot for closeup]
This plot

This is the Health Check plot to monitor the system efficiency of GIRAFFE, with all data plotted on a chromatic scale (wavelength in nm). Find more about the efficiency monitoring here.

We display the QC1 parameter mean_effic (the ratio of detected photons and incident photons) versus wavelength, for the HR and LR gratings separately.

The top row has data for the old CCD (used until 2008-03-13); the bottom row shows the new CCD (in operations since 2008-05-14).  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up