ISAAC trending system: HEALTH CHECK plot
Last update: 2008-12-02T02:24:17 (UT)
now: 2008-12-02T23:06:31 (UT)
scores under test! INFO USERS-GUIDE MORE
same group: Linearity@10000 Lin_zoom@10000 Linearity@5000 Lin_zoom@5000
last OPSLOG data:
2008-11-30
Plot: 1 2 3 4   latest_files
N_data: number of recent OPSLOG entries plotted here
N_data: 9 8 0 0 availability
close window history: 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008   HEALTH
  ... ... ... ... ... ... ... ...
Print: Information and research: News:
- png file - advanced studies: QC1 browser | QC1 plotter
  • From 2008-04 on the max counts is no longer 4000 ADU but 20000 ADU. The effective non-linearity correction at 10000 ADU is no longer an extrapolation.
 
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 oQC1DB yes (9) MEDIAN -0.00848 ratio VAL-0.05,0.05 122 qc_detlin_eff this | last_yr | all SW-arm, DoubleCorr nonlinearity correction fraction at 10000 ADU
2 oQC1DB yes (8) MEDIAN 0.02559 ratio VAL0.02,0.04 94 qc_detlin_eff this | last_yr | all LW, UncorrHighBias nonlinearity correction fraction at 10000 ADU
3 oQC1DB yes (0) MEDIAN -0.09993 ratio none   11 qc_detlin_eff this | last_yr | all LW, DoubleCorrHighBias nonlinearity correction fraction at 10000 ADU
4 oQC1DB yes (0) MEDIAN -4118.0498 ratio none   12 qc_detlin_eff this | last_yr | all LW, DoubleCorrLowBias nonlinearity correction fraction at 10000 ADU
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate that OPSLOG data are included
This plot

This is the trending plot for the ISAAC Linearity calibration frames. The non-linearity polynom is :

counts_corrected = counts_meas + B/A * counts_meas^2 + C/A * counts_meas^3

Dividing by counts_meas, and subtracting 1 and apply the formular for a reference count level of 10 000 ADU we get:

lin_eff (10000 ADU) = ( counts_corr / counts_meas ) - 1 =

B/A * 10000 + C/A * 10000 * 10000 =

These plots describe:
1. SW, DoubleCorr
2. LW, UncorrHighBias
3. LW, DoubleCorrHighBias
4. LW, DoubleCorrLowBias
Find more information about ISAAC Linearity frames here.

Other QC parameters related to detector properties (like read noise, are trended.  


General information

Click on any of the plots to see a close-up version.

If applicable, the latest values from Paranal ops logs are plotted as blue dots. More information about those values, including a download option, is available in the OPSLOG section on top of the page.

The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up