[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
NACO trending system: HEALTH CHECK report
Last update: 2012-05-25T10:41:57 (UT)
| now: 2012-05-26T04:03:10 (UT)
HELP USERS-GUIDE MORE
same group: RON_DAILY RON_NONDAILY   8-col-noise 8col_noise_zoomed
General news: 2012-05-24: The HC monitors for OMEGACAM, VIRCAM and HAWKI are back. Population with current data is in progress.
NACO news:
Report news:  
DATE*: [?] 2012-05-19
report | NR
2012-05-20
report | NR
2012-05-21
report | NR
2012-05-22
report | NR
2012-05-23
report | NR
2012-05-24
report | NR
2012-05-25
report | NR
P...
Product quality:
products products products products products products products
  last OPSLOG data:
2012-05-24*

last files ...
monitor
close window history: 2004 2005 2006 2007 2008 2009 2010 2011   2012   HEALTH
  ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB yes (20) MEAN 3.8666   VAL2,6.2 266 dark_ron12 this | last_yr | all Double ReadResetRead read-out-mode
2 +QC1DB yes (3) MEAN 4.80459   VAL3,6.1 111 dark_ron12 this | last_yr | all Uncorrelated read-out-mode
3 *QC1DB yes (10) MEAN 1.27596   VAL0.6,2.0 126 dark_ron12 this | last_yr | all FowlerNSample read-out-mode, DIT <= 90s
4 oQC1DB yes (4) MEAN 2.39415   VAL0.6,3.2 53 dark_ron12 this | last_yr | all FowlerNSample read-out-mode, DIT > 90s
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate that OPSLOG data are included
Plot 1
scores: 56|
data source:naco_dark
(QC1 database)
dataset:dark_ron12
mean:3.8666 
fixed thresholds:2.0...6.2 
N_data plotted:266
[click on plot for closeup]
Plot 2
scores: 19|
data source:naco_dark
(QC1 database)
dataset:dark_ron12+
mean:4.80459 
fixed thresholds:3.0...6.1 
N_data plotted:111
[click on plot for closeup]
Plot 3
scores: 18|
data source:naco_dark
(QC1 database)
dataset:dark_ron12*
mean:1.27596 
fixed thresholds:0.6...2.0 
N_data plotted:126
[click on plot for closeup]
Plot 4
scores: 8|
data source:naco_dark
(QC1 database)
dataset:dark_ron12o
mean:2.39415 
fixed thresholds:0.6...3.2 
N_data plotted:53
[click on plot for closeup]
This plot

Read Out Noise values are shown for all three readout modes: Double_ReadResetRead ("DCR"), Multiple FowlerNsampling ("FNS") and Uncorrelated ("UCR"). The data calculated from darks taken with different integration time values (DIT) are displayed together. Only for the FNS readout mode, the data points are separated for darks taken with DIT less and more than 90 sec.  


General information

Click on any of the plots to see a close-up version.

If applicable, the latest values from Paranal ops logs are plotted as blue dots. More information about those values, including a download option, is available in the OPS column.

The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up