[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
SINFONI trending system: HISTORY report
Last update: 2012-06-28T09:24:23 (UT)
same group: psf_flux psf_strehl psf_persistence psf_center
close window history: 2009 2010 2011   2012   2013   2014 2015 2016 2017 2018 2019   HEALTH
  ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 oQC1DB MEDIAN 2.01318 ADU VAL1.8,300.0 12 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture in the J-band at all camera scales (ADU)
(this FULL data set is scored)
1 QC1DB none   ADU none   12 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture: J-band/250 mas scale
1 QC1DB none   ADU none   0 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture: J-band/100 mas scale
1 QC1DB none   ADU none   0 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture: J-band/25 mas scale

2 oQC1DB MEDIAN 2.14525 ADU VAL1.8,300.0 14 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture in the H-band at all camera scales (ADU)
(this FULL data set is scored)
2 QC1DB none   ADU none   10 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture: H-band/250 mas scale
2 QC1DB none   ADU none   4 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture: H-band/100 mas scale
2 QC1DB none   ADU none   0 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture: H-band/25 mas scale

3 oQC1DB MEDIAN 3.64505 ADU VAL1.8,300.0 73 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture in the K-band at all camera scales (ADU)
(this FULL data set is scored)
3 QC1DB none   ADU none   13 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture: K-band/250 mas scale
3 QC1DB none   ADU none   60 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture: K-band/100 mas scale
3 QC1DB none   ADU none   0 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture: K-band/25 mas scale

4 oQC1DB MEDIAN   ADU VAL1.8,300.0 0 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture in the H+K-band at all camera scales (ADU)
(this FULL data set is scored)
4 QC1DB none   ADU none   0 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture: H+K-band/250 mas scale
4 QC1DB none   ADU none   0 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture: H+K-band/100 mas scale
4 QC1DB none   ADU none   0 qc_net_flux this | last_yr | all mean flux per pixel within a 3 sigma aperture: H+K-band/25 mas scale

*Data sources: QC1DB: QC1 database; LOCAL: local text file
Plot 1
data source:sinfoni_psf
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_net_fluxo
median:2.01318ADU
fixed thresholds:1.8...300.0ADU
N_data plotted:12
[click on plot for closeup]
Plot 2
data source:sinfoni_psf
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_net_fluxo
median:2.14525ADU
fixed thresholds:1.8...300.0ADU
N_data plotted:14
[click on plot for closeup]
Plot 3
data source:sinfoni_psf
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_net_fluxo
median:3.64505ADU
fixed thresholds:1.8...300.0ADU
N_data plotted:73
[click on plot for closeup]
Plot 4
data source:sinfoni_psf
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_net_fluxo
median:no dataADU
fixed thresholds:1.8...300.0ADU
N_data plotted:0
[click on plot for closeup]
This plot

These are the trending plots for the SINFONI QC parameters derived from the PSF calibration frames. PSF standard star monitoring has been implemented beginning 2009-05-01.

The intent is to monitor the MINIMUM flux of the PSF star to insure that it has an adequate S/N. Flux levels should be above 3 ADU/pixel within a 3 sigma aperture for the K and H+K-band. In the case of the J and H-band PSF stars, the minimum allowed flux level is 2 ADU/pixel within a 3 sigma aperture.

The PSF standard star is often used to test the centering of science exposures. Therefore, we monitor the radial offset from the nominal field center: R = sqrt[ (x-x0)^2 + (y-y0)^2 ].

Find more information about SINFONI PSF calibration data here.

Other QC parameters are also trended here.  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up