mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
FULL reports
SINFONI:
lamp flat
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
SINFONI trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2014-07-24T18:01:30 (UT)
  | now: 2014-07-24T23:37:57 (UT) muc04 QC pipeline: sinfo-2.5.3 (installed 2014-05-22)
same group: lamp_eff   lamp_badpix lamp_off lamp_fpn1 lamp_fpn2 vignetting_check_sl1 vignetting_check_sl32
General news:
SINFONI news:
Report news:
DATE*: [?] 2014-07-17
report | NLT
2014-07-18
report | NLT
2014-07-19
report | NLT
2014-07-20
report | NLT
2014-07-21
report | NLT
2014-07-22
report | NLT
2014-07-23
report | NLT
2014-07-24
no data | NLT
P...
Product quality:
products products products products products products products no products
  no OPSLOG data  

scores&comments | FULL | history ... | plot tutorial ... | contact               [?]
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB no MEDIAN 0.443 Relative_Flux VAL0.22,1.0 457 qc_rf1 this | last_yr | all relative flux in slitlet (for ALL filters and pixel scales)
2 QC1DB no MEDIAN 0.798 Relative_Flux VAL0.24,1.0 457 qc_rf32 this | last_yr | all relative flux in slitlet (for ALL filters and pixel scales)
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: OPSLOG data are included
Plot 1
scores: 21|
data source:sinfoni_flat
(QC1 database)
dataset:qc_rf1
median:0.443Relative_Flux
fixed thresholds:0.22...1.0Relative_Flux
N_data plotted:457
[click on plot for closeup]
Plot 2
scores: 21|
data source:sinfoni_flat
(QC1 database)
dataset:qc_rf32
median:0.798Relative_Flux
fixed thresholds:0.24...1.0Relative_Flux
N_data plotted:457
[click on plot for closeup]
This plot

These are the trending plots for the vignetting check computed from the LAMP FLATs.

Slitlets #1 and #32 correspond to the upper-most and the lower-most slitlets in the field-of-view.
As such, these slitlets can be subject to vignetting to the extent that their overall count rates can be a few 10% lower than for other slitlets. Following image reconstruction, these slitlets are located on the central part of the detector. A possible vignetting is monitored by comparing the relative count rates (i.e. the mean counts in the slitlet #1 or #32 divided by the mean counts in all other slitlets).
This QC1 parameter is most relevant following an instrument intervention.  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up