mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
SINFONI:
SCIENCE
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
SINFONI trending system: HEALTH CHECK plot
Last update: 2011-11-10T05:17:44 (UT)
| now: 2014-07-25T18:29:01 (UT)
HELP USERS-GUIDE MORE
same group: science_persistence science_std science_wave
General news:
Report news: In light of the new operational model QC-XXLight, SINFONI science data is no longer processed. Thus, the final data point in this health check plot is that of Oct. 11, 2011.

DATE*: [?] 2014-07-18
report | NLT
2014-07-19
report | NLT
2014-07-20
report | NLT
2014-07-21
report | NLT
2014-07-22
report | NLT
2014-07-23
report | NLT
2014-07-24
report | NLT
P...
Product quality:
products products products products products products products
  no OPSLOG data  
scores&comments ... | history ... | plot tutorial ... | contact                 daily/often; important to check     [?] *Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB no none   days VAL-0.5,0.5 472 qc_delta_time this | last_yr | all Difference in time between science data and its associated telluric standard (in days).
2 QC1DB no none   unitless VAL-0.7,0.7 472 qc_delta_am this | last_yr | all Difference in airmass between science data and its associated telluric standard.
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate that OPSLOG data are included
Plot 1
scores: not implemented
data source:sinfoni_sci
(QC1 database)
dataset:qc_delta_time
average:none
fixed thresholds:-0.5...0.5days
N_data plotted:472
[click on plot for closeup]
Plot 2
scores: not implemented
data source:sinfoni_sci
(QC1 database)
dataset:qc_delta_am
average:none
fixed thresholds:-0.7...0.7unitless
N_data plotted:472
[click on plot for closeup]
This plot

These are the trending plots for the SINFONI QC parameters derived from the SCIENCE products.

Science product monitoring has been implemented beginning 2009-05-01.

NOTE: Large positive outliers in the delta time or delta airmass plots are the result of a missing airmass keyword in either the science or STD image.
NOTE 2: From 2009-10-01 the delta time/airmass values are measured from mid-OB. Previously, the delta time/airmass values are those of the first science frame in the OB.

Find more information about SINFONI Science data here.

Other QC parameters are also trended here.  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up