[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
UVES trending system: HISTORY report
Last update: 2012-05-08T21:37:28 (UT)
same group: Mean RMS
close window history: 2003 2004   2005   2006   2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024   HEALTH
  ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 0.00821 Pix VAL0.005,0.015 69 ydiffrms this | last_yr | all RMS of Y-Differences between the two frames
2 QC1DB MEDIAN 0.02329 Pix VAL0.010,0.040 70 ydiffrms this | last_yr | all same, for CD#2
3 QC1DB MEDIAN 0.01916 Pix VAL0.010,0.030 69 ydiffrms this | last_yr | all same, for CD#3
4 QC1DB MEDIAN 0.03696 Pix VAL0.025,0.055 69 ydiffrms this | last_yr | all same, for CD#4
*Data sources: QC1DB: QC1 database; LOCAL: local text file
Plot 1
data source:uves_zflat
(QC1 database)
dataset:ydiffrms
median:0.00821Pix
fixed thresholds:0.005...0.015Pix
N_data plotted:69
[click on plot for closeup]
Plot 2
data source:uves_zflat
(QC1 database)
dataset:ydiffrms
median:0.02329Pix
fixed thresholds:0.01...0.04Pix
N_data plotted:70
[click on plot for closeup]
Plot 3
data source:uves_zflat
(QC1 database)
dataset:ydiffrms
median:0.01916Pix
fixed thresholds:0.01...0.03Pix
N_data plotted:69
[click on plot for closeup]
Plot 4
data source:uves_zflat
(QC1 database)
dataset:ydiffrms
median:0.03696Pix
fixed thresholds:0.025...0.055Pix
N_data plotted:69
[click on plot for closeup]
This plot

This is the trending report for UVES QC parameters derived from the Cross-Disperser Alignment reproducibility frames.

These data are taken daily. Each Cross-Disperser [CD] is moved into position such that the zeroth order from the echelle falls on the detector and the first frame is exposed, then the CD is moved away, and then moved back into position and the second frame is taken. Ideally, if the mechanical mechanisms are working perfectly, the zeroth order will appear at exactly the same position in the two frames. So this data tests the reproducability of the instrumental setup, in particular that the instrumental setups used during the night can be accurately reproduced during daytime calibrations.

The spatial position of the zeroth order is then measured at a number (~25) positions along the order in the two frames. Plots 1 to 4 display the RMS of the differences between the measured positions in the two frames.

Find more information about UVES CD_ALIGN frames here.  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up