UVES trending system: FULL report
HELP USERS-GUIDE MORE
Last update: 2024-10-08T06:06:53 (UT)
  | now: 2024-10-08T09:41:25 (UT) muc02 QC pipeline: uves-6.1.11 (installed 2023-06-22)
close window history: 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023   2024   HEALTH FULL
  ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
- for reprocessing data: QC1_browser | QC1_plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 11.7 [C] none  60676 ins_temp1_mean all (full time range) Mean temperature of CAMERA
2 QC1DB MEDIAN 11.7 [C] none  60676 ins_temp1_mean all (full time range) temperature (repeated)
3 QC1DB MEDIAN 11.7 [C] none  60676 ins_temp1_mean all (full time range) temperature (repeated)
4 +QC1DB MEDIAN -0.46 [pix] none  9503 mean_dx all (full time range) DX between solution and Physical Model, CD#4, REDU 860nm, 1x1
4 +QC1DB none     none  2738 mean_dx all (full time range) same, from reprocessing 2015 with uves/5.5.3
5 +QC1DB MEDIAN 3.86 [pix] none  9503 mean_dy all (full time range) DY
5 +QC1DB none     none  2738 mean_dy all (full time range) same, from reprocessing 2015 with uves/5.5.3
6 +QC1DB MEDIAN 315 NONE none  9503 nlin_sel all (full time range) Number of lines used in solution
6 +QC1DB none   NONE none  2738 nlin_sel all (full time range) same, from reprocessing 2015 with uves/5.5.3
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:uves_fmtchk
(QC1 database)
dataset:ins_temp1_mean
median:11.7[C]
thresholds:none 
N_data plotted:60676
[click plot for closeup]
Plot 2
scores: not implemented
data source:uves_fmtchk
(QC1 database)
dataset:ins_temp1_mean
median:11.7[C]
thresholds:none 
N_data plotted:60676
[click plot for closeup]
Plot 3
scores: not implemented
data source:uves_fmtchk
(QC1 database)
dataset:ins_temp1_mean
median:11.7[C]
thresholds:none 
N_data plotted:60676
[click plot for closeup]
Plot 4
scores: not implemented
data source:uves_fmtchk
(QC1 database)
dataset:
(numbers below apply to this dataset)
mean_dx+
median:-0.46[pix]
thresholds:none 
N_data plotted:9503
[click plot for closeup]
Plot 5
scores: not implemented
data source:uves_fmtchk
(QC1 database)
dataset:
(numbers below apply to this dataset)
mean_dy+
median:3.86[pix]
thresholds:none 
N_data plotted:9503
[click plot for closeup]
Plot 6
scores: not implemented
data source:uves_fmtchk
(QC1 database)
dataset:
(numbers below apply to this dataset)
nlin_sel+
median:315NONE
thresholds:none 
N_data plotted:9503
[click plot for closeup]
This plot

This is the trending report for UVES QC parameters derived from the Echelle format check calibrations taken in wavelength setting 860, RED Upper CCD. The results are redundant with the "860L" plot except for plot #6 which monitors the number of lines and therefore also the pipeline recipe quality.

Calibrating SCIENCE observations made during the night with calibrations taken during the day relies on the stability and reproducibility of the positioning of the instrument components. To insure an accurate wavelength calibration, one of the critical criteria is the accuracy of the positioning of the gratings.

The important aspects in these plots are the day to day scatter. The absolute level, within reason (i.e. plus or minus 10 pixels) is not important.

From time to time there are sudden jumps in the mean levels, sometimes due to earthquakes, but often the cause of the jump is far from obvious. Such jumps are not in themselves a cause for immediate concern. Only if they are happening frequently, and liable to be happening during the night. Or if they take the instrument so far from the Physical Model that the pipeline will have serious difficulties to converge to a solution, as a rule of thumb, intervention to realign should be considered if the residuals exceed plus or minus 10 pixels.

The individual plots describe:

  1. average air temperature of the camera [C] (INS.TEMP4.NAME). Trends in the residuals often correlate with temperature.
  2. same as 1
  3. same as 1
  4. the mean residual in X of the fitted position of the emission lines with respect to the positions expected from the Physical Model
  5. the same for Y
  6. the number of emission lines selected in the final solution. Trends in this parameter can be due to lamp aging effects.

Data in red in the plots #4-#6 refer to the UVES_M reprocessing project in 2015.
Find more information about UVES Grating Position monitoring here.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up