Plot ? |
Symb ? |
Source * |
Average ? |
Thresholds ? |
N_ data |
QC1 parameter |
Data downloads |
Remarks |
method |
value |
unit |
method |
value |
1 |
| QC1DB |
none |
|
counts/sec |
none | |
1318 |
mean_master |
all (full time range)
| Stability of LAMP1 (flatfield deuterium lamp), BLUE CCD, 346nm, 1x1 |
1 |
| QC1DB |
none |
|
counts/sec |
none | |
216 |
mean_master |
all (full time range)
| same, from reprocessing 2015 with uves/5.5.3 |
2 |
| QC1DB |
none |
|
counts/sec |
none | |
1759 |
mean_master |
all (full time range)
| same for LAMP3 (FF lamp), same setups |
2 |
| QC1DB |
none |
|
counts/sec |
none | |
350 |
mean_master |
all (full time range)
| same, from reprocessing 2015 with uves/5.5.3 |
3 |
| QC1DB |
none |
|
counts/sec |
none | |
1833 |
mean_master |
all (full time range)
| same for LAMP4 (FF lamp), 437nm, 1x1 |
|
3 |
| QC1DB |
none |
|
counts/sec |
none | |
617 |
mean_master |
all (full time range)
| same, from reprocessing 2015 with uves/5.5.3 |
5 |
| QC1DB |
none |
|
counts/sec |
none | |
1725 |
mean_master |
all (full time range)
| same for LAMP5 (FF lamp), RED UPPER CCD, 580nm, 1x1 |
5 |
| QC1DB |
none |
|
counts/sec |
none | |
581 |
mean_master |
all (full time range)
| same, from reprocessing 2015 with uves/5.5.3 |
6 |
| QC1DB |
none |
|
counts/sec |
none | |
1725 |
mean_master |
all (full time range)
| same for LAMP5, RED LOWER CCD, 580nm, 1x1 |
6 |
| QC1DB |
none |
|
counts/sec |
none | |
576 |
mean_master |
all (full time range)
| same, from reprocessing 2015 with uves/5.5.3 |
7 |
| QC1DB |
none |
|
counts/sec |
none | |
1242 |
mean_master |
all (full time range)
| same for LAMP6 (FF lamp), RED UPPER CCD, 860nm, 1x1 |
7 |
| QC1DB |
none |
|
counts/sec |
none | |
297 |
mean_master |
all (full time range)
| same, from reprocessing 2015 with uves/5.5.3 |
8 |
| QC1DB |
none |
|
counts/sec |
none | |
1242 |
mean_master |
all (full time range)
| same for LAMP6, RED LOWER CCD, 860nm, 1x1 |
8 |
| QC1DB |
none |
|
counts/sec |
none | |
298 |
mean_master |
all (full time range)
| same, from reprocessing 2015 with uves/5.5.3 |
|
*Data sources: QC1DB: QC1 database; LOCAL: local data source
|
Plot 1 scores: not implemented
| data source: | uves_flat (QC1 database) |
dataset: (numbers below apply to this dataset) | mean_master | |
average: | none |
thresholds: | none |
N_data plotted: | 1318 |
[click plot for closeup] |
Plot 2 scores: not implemented
| data source: | uves_flat (QC1 database) |
dataset: (numbers below apply to this dataset) | mean_master | |
average: | none |
thresholds: | none |
N_data plotted: | 1759 |
[click plot for closeup] |
Plot 3 scores: not implemented
| data source: | uves_flat (QC1 database) |
dataset: (numbers below apply to this dataset) | mean_master | |
average: | none |
thresholds: | none |
N_data plotted: | 1833 |
[click plot for closeup] |
Plot 5 scores: not implemented
| data source: | uves_flat (QC1 database) |
dataset: (numbers below apply to this dataset) | mean_master | |
average: | none |
thresholds: | none |
N_data plotted: | 1725 |
[click plot for closeup] |
Plot 6 scores: not implemented
| data source: | uves_flat (QC1 database) |
dataset: (numbers below apply to this dataset) | mean_master | |
average: | none |
thresholds: | none |
N_data plotted: | 1725 |
[click plot for closeup] |
Plot 7 scores: not implemented
| data source: | uves_flat (QC1 database) |
dataset: (numbers below apply to this dataset) | mean_master | |
average: | none |
thresholds: | none |
N_data plotted: | 1242 |
[click plot for closeup] |
Plot 8 scores: not implemented
| data source: | uves_flat (QC1 database) |
dataset: (numbers below apply to this dataset) | mean_master | |
average: | none |
thresholds: | none |
N_data plotted: | 1242 |
[click plot for closeup] |
This plot
This is the trending report for the UVES flat lamps. It monitors the deuterium
lamp and the four standard flat-field lamps. It is based on data taken roughly
once a week. Trends in this plot probably indicate aging of the lamp.
These plots describe:
- the mean_master QC parameter for LAMP 1, the Deuterium
lamp used for BLUE FLATs with settings CD#1, 300-360nm
- the mean_master QC parameter for LAMP 3, used for BLUE
FLATs with settings CD#1, 300-400nm
- the mean_master QC parameter for LAMP 4, used for BLUE
FLATs with settings CD#2, 330-480nm
- the mean_master QC parameter for LAMP 5, REDU CCD, used
for RED FLATs with settings CD#3, 450-650nm (which also
includes MOS slit flats for the 520 and 580 settings)
- the same for the REDL CCD
- the mean_master QC parameter for LAMP 6, REDU CCD, used
for RED FLATs with settings CD#3, 650-750nm and CD#4,
600-950nm (which also includes MOS slit flats for the 860 setting)
- the same for the REDL CCD.
Data points in blue refer to the master calibration reprocessing project
UVES_M from 2015.
Find more information about UVES Echelle FLAT frames here.
General information
Click on any of the plots to see a close-up version.
The latest date is indicated on top of the plot.
If configured,
- data points belonging to the latest date are specially marked
- statistical averages are indicated by a solid line, and thresholds by broken lines
- outliers are marked by a red asterisk. They are defined as data points outside the
threshold lines
- "aliens" (= data points outside the plot Y limits) are marked by a red arrow (↑ or ↓)
- you can download the data for each parameter set if the 'Data downloads' link shows up
|