C         [page auto-refreshes after 300 sec]            [press Ctrl+R to enforce refresh of scores and dates]
VIMOS trending system: HISTORY plot
Last update: 2010-04-11T03:10:36 (UT)
same group: X0_Y0 XX_YY XY_YX   Y0_TEMP
close window history: 2006 2007 2008 2009   2010   2011   2012 2013 2014 2015 2016 2017 2018   HEALTH
  ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 0.00175 pix/mm VAL-0.002,0.006 90 xy this | last_yr | all coefficient a(xy), Q2
2 QC1DB MEDIAN 0.00883 pix/mm VAL0.005,0.015 90 xy this | last_yr | all coefficient a(xy), Q1
3 QC1DB MEDIAN -0.0022 pix/mm VAL-0.006,0.002 90 yx this | last_yr | all coefficient a(yx), Q2
4 QC1DB MEDIAN -0.00796 pix/mm VAL-0.015,-0.005 90 yx this | last_yr | all coefficient a(yx), Q1
5 QC1DB MEDIAN 0.01018 pix/mm VAL0.006,0.014 90 xy this | last_yr | all coefficient a(xy), Q3
6 QC1DB MEDIAN -0.00337 pix/mm VAL-0.006,0.002 90 xy this | last_yr | all coefficient a(xy), Q4
7 QC1DB MEDIAN -0.01141 pix/mm VAL-0.014,-0.006 90 yx this | last_yr | all coefficient a(yx), Q3
8 QC1DB MEDIAN 0.00251 pix/mm VAL-0.002,0.006 90 yx this | last_yr | all coefficient a(yx), Q4
*Data sources: QC1DB: QC1 database; LOCAL: local text file
This plot

Trending plots for monitoring the coefficients of the mask to CCD transformation.

The transformation is as follows:
X = a(xx)*x + a(xy)*y + x(0)
Y = a(yx)*x + a(yy)*y + y(0)
with (x,y) being mask coordinates in mm and (X,Y) CCD coordinates in pixel. X direction is along the slit orientation, y direction is perpendicular to the slits (i.e. in dispersion direction).

These trending plots show the time evolution of the matrix coefficients a(xx), a(xy), a(yx), and a(yy). The diagonal coefficients a(xx) and a(yy) give the scale factor between mask and CCD (near 8.4 pixel/mm). Variations are mainly cause by temperature changes, the empirical tolerance is around +/- 0.006 pixel/mm. The coefficients a(xy) and a(yx) give the rotation and should be near zero. The tolerance is +/- 0.005 pixel/mm around the empirical average. The procedure in case of violation of the thresholds is described on the SciOps Wiki pages.

Template ID: img_tec_MaskToCcd. Pipeline recipe: vmmasktoccd.  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up