[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
VIMOS trending system: HEALTH CHECK report
Last update: 2012-05-26T03:37:12 (UT)
| now: 2012-05-26T08:04:12 (UT)
HELP USERS-GUIDE MORE
same group: LRb_cent LRr_cent MR_cent HRb_cent HRo_cent HRr_cent   LRb_full LRr_full MR_full HRb_full HRo_full HRr_full
General news: 2012-05-24: The HC monitors for OMEGACAM, VIRCAM and HAWKI are back. Population with current data is in progress.
VIMOS news:  
Report news:  
DATE*: [?] 2012-05-19
report | NR
2012-05-20
report | NR
2012-05-21
report | NR
2012-05-22
report | NR
2012-05-23
report | NR
2012-05-24
report | NR
2012-05-25
no data | NR
P...
Product quality:
products products products products products products no products
  no OPSLOG data  
close window history: 2004 2005 2006 2007 2008 2009 2010 2011 2012   HEALTH
  ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB no none   none none  165 resol3 this | last_yr | all spectral resolution, blue end
1 QC1DB no none   none none  165 resol1 this | last_yr | all spectral resolution, red end
1 QC1DB no MEDIAN 540.98 none VAL450,650 165 resol2 this | last_yr | all spectral resolution, centre
2 QC1DB no none   none none  162 resol3 this | last_yr | all spectral resolution, blue end
2 QC1DB no none   none none  162 resol1 this | last_yr | all spectral resolution, red end
2 QC1DB no MEDIAN 545.464 none VAL450,650 162 resol2 this | last_yr | all spectral resolution, centre
3 QC1DB no none   none none  163 resol3 this | last_yr | all spectral resolution, blue end
3 QC1DB no none   none none  163 resol1 this | last_yr | all spectral resolution, red end
3 QC1DB no MEDIAN 544.544 none VAL450,650 163 resol2 this | last_yr | all spectral resolution, centre
4 QC1DB no none   none none  164 resol3 this | last_yr | all spectral resolution, blue end
4 QC1DB no none   none none  164 resol1 this | last_yr | all spectral resolution, red end
4 QC1DB no MEDIAN 545.972 none VAL450,650 164 resol2 this | last_yr | all spectral resolution, centre
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate that OPSLOG data are included
Plot 1
scores: not implemented
data source:vimos_mos_wave
(QC1 database)
dataset:
(numbers below apply to this dataset)
resol3
average:none
thresholds:none
N_data plotted:165
[click on plot for closeup]
Plot 2
scores: not implemented
data source:vimos_mos_wave
(QC1 database)
dataset:
(numbers below apply to this dataset)
resol3
average:none
thresholds:none
N_data plotted:162
[click on plot for closeup]
Plot 3
scores: not implemented
data source:vimos_mos_wave
(QC1 database)
dataset:
(numbers below apply to this dataset)
resol3
average:none
thresholds:none
N_data plotted:163
[click on plot for closeup]
Plot 4
scores: not implemented
data source:vimos_mos_wave
(QC1 database)
dataset:
(numbers below apply to this dataset)
resol3
average:none
thresholds:none
N_data plotted:164
[click on plot for closeup]
This plot

Trending plot for resolution (resolving power R) derived from MOS arc lamp measurements.

Only arc lamp measurements taken to calibrate MOS science observations are used; exposures with the standard star masks are disregarded. Only measurements with slit_width_dis=1.0 are plotted.

Resolution is measured at the blue and the red end, and at the centre of the spectral range. The "cent" plots only show the latter; they include scoring. The "full" plots also show the results at the blue and red ends; these are not scored. For LR_blue, the resolution at the blue and red ends are usually not well determined by the new pipeline; therefore only the central value is plotted.

Template ID: mos_cal_Arc (daytime), mos_cal_NightCalib (attached night-time). Pipeline recipe: vmspcaldisp.  


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up