mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

[an error occurred while processing this directive]
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
XSHOOTER trending system: FULL report
HELP USERS-GUIDE MORE
Last update: 2025-09-12T04:53:38 (UT)
  | now: 2025-09-12T06:30:27 (UT) muc02 QC pipeline: xshoo-3.6.5a (installed 2023-09-18)
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
XSHOOTER news:  
Report news: [an error occurred while processing this directive]
DATE*: [?] 2025-09-05
report | NLT
2025-09-06
report | NLT
2025-09-07
report | NLT
2025-09-08
report | NLT
2025-09-09
report | NLT
2025-09-10
report | NLT
2025-09-11
no data | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw no CAL raw files
P...
CAL product quality:
products products products products products products no CAL products
 
transfer   ngas [?]

scores&comments | history: all data plotted here | plot tutorial ... | contact | HC_docu... | quality events...               [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 0.152 NONE none  3293 eff2 all (full time range) Relative efficiency for UVB arm, range 5100A - 5300A
2 QC1DB MEDIAN 8.18e+04 ADU none  3309 counts2 all (full time range) median star counts in UVB arm, range 5100A - 5300A
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:xshooter_fluxeff
(QC1 database)
dataset:eff2
median:0.152NONE
thresholds:none 
N_data plotted:3293
[click plot for closeup]
Plot 2
scores: not implemented
data source:xshooter_fluxeff
(QC1 database)
dataset:counts2
median:8.18e+04ADU
thresholds:none 
N_data plotted:3309
[click plot for closeup]
This plot

This plot shows the efficiency per echelle order. The efficiency is obtained from flux standard stars acquired with a 5 arcsec wide slit. The different count rates in Plot No. 2 originate from the different magnitutes within the set of used flux standard stars.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up