SETINSD
Section: User Commands (1)
Updated: 2012-04-23 10:09
Index
Return to man pages list
NAME
SETINSD - Set configuration parameters for the
selected instrument
SYNOPSIS
SETINSD insId .
DESCRIPTION
Sets configuration parameters for the selected instrument
insId: String up to 32 character, ins+detector id (IsaacLw)
insMode: String up to 32 character, ins mode id
focusStation: String with the focus station name for the instrument
"UNDEFINED", "NA","NB","CA","CO","IM"
offsetRot: Rotator offset in degrees (DD.fff)
offsetFocus: Optimal focus offset (mm)
pixelSizeX: Detector pixel sizs in X direction (micron)
pixelSizeY: Detector pixel sizs in Y direction (micron)
vigAreaSizeX: Vignetting area size along X direction (arcsec)
vigAreaSizeY: Vignetting area size along Y direction (arcsec)
vigAreaCntX: Center in X of vignetting rectangle with respect to center
of field (arcsec)
vigAreaCntY: Center in Y of vignetting rectangle with respect to center
of field (arcsec)
pointAxisOffX: Offset of pointing axis in X (arcsec)
pointAxisOffY: Offset of pointing axis in X (arcsec)
detectorLcu: Str up to 256 ch. Environment + process name (@env:proc)
refX, refY : Reference pixel on chip
adapterFocus: Optimal adapter focus in mm
OK
or error structure
CAUTIONS
New fields will be added in a next release, in particular to handle
detector vignetting, pointing axis and detector focus.
EXAMPLES
SETINSD IsaacLw,NA,-12.5,12,12,@lt5islw:isServer
Index
- NAME
-
- SYNOPSIS
-
- DESCRIPTION
-
- OK
-
- CAUTIONS
-
- EXAMPLES
-
This document was created by
man2html,
using the manual pages.
Time: 10:09:57 GMT, April 23, 2012