SETINSD

Section: User Commands (1)
Updated: 2012-04-23 10:09
Index Return to man pages list
 

NAME


   SETINSD - Set configuration parameters for the
             selected instrument

 

SYNOPSIS


   SETINSD insId                                                     .

 

DESCRIPTION


    Sets configuration parameters for the selected instrument

      insId: String up to 32 character, ins+detector id (IsaacLw)
      insMode: String up to 32 character, ins mode id
      focusStation: String with the focus station name for the instrument
                    "UNDEFINED", "NA","NB","CA","CO","IM"
      offsetRot: Rotator offset in degrees (DD.fff)
      offsetFocus: Optimal focus offset (mm)
      pixelSizeX: Detector pixel sizs in X direction (micron)
      pixelSizeY: Detector pixel sizs in Y direction (micron)
      vigAreaSizeX: Vignetting area size along X direction (arcsec)
      vigAreaSizeY: Vignetting area size along Y direction (arcsec)
      vigAreaCntX: Center in X of vignetting rectangle with respect to center
                   of field (arcsec)
      vigAreaCntY: Center in Y of vignetting rectangle with respect to center
                   of field (arcsec)
      pointAxisOffX: Offset of pointing axis in X (arcsec)
      pointAxisOffY: Offset of pointing axis in X (arcsec)
      detectorLcu: Str up to 256 ch. Environment + process name (@env:proc)
      refX, refY : Reference pixel on chip
      adapterFocus: Optimal adapter focus in mm

 

OK


    or error structure

 

CAUTIONS


    New fields will be added in a next release, in particular to handle
    detector vignetting, pointing axis and detector focus.

 

EXAMPLES


   SETINSD IsaacLw,NA,-12.5,12,12,@lt5islw:isServer



 

Index

NAME
SYNOPSIS
DESCRIPTION
OK
CAUTIONS
EXAMPLES

This document was created by man2html, using the manual pages.
Time: 10:09:57 GMT, April 23, 2012