Azimuth Cable Wrap

Azimuth Cable Wrap interfaces:

The connection layout and pin assignment of Z5 and J6 is given in Annex [AN1] VLT-DWG-ESO-15154-1770

Item
From
To
Signal
Description
COMMUNICATION:
      PHASE Communication RS485 Port - Protocol S-Link 3 [RD 06]
CABLE WRAP:
1 ATS LCU No Fault Contact closed if cable wrap OK (see interlock section)
Source driver 24V, 100mA max.
Digital Input
2 ATS LCU Torque signal + [Nm/V] Analog signal -10V/+10V, 5mA (differential)
Analog input
3 ATS LCU Torque signal - Analog input
4     Shield  
5 LCU ATS Amplifier Enable Contact status 6.6kW to GND
Digital Output
SWITCHES:
8 ATS LCU Cable Wrap Positive Limit+ Contact opens if Cablewrap do not follow azimuth axis in positive direction
9 ATS LCU Cable Wrap Positive Limit- contact return
10 ATS LCU Cable Wrap Negative Limit+ Contact opens if Cablewrap do not follow azimuth axis in negative direction
11 ATS LCU Cable Wrap Negative Limit- return

Last modified: Mon 07-May-2001 8:41