E |
Board |
Supplier |
Number |
|
CPU |
Motorola MVME 2604 (PowerPC, 333 MHz, 32/64MB) |
1 |
|
|
Time Interface |
ESO TIM |
1 |
|
|
Digital I/O Interface |
Acromag AVME 9481 |
1 |
|
|
STRAP VME control board |
Microgate |
1 |
|
|
TCCD boards |
LIB (INMOS BO16) + LAB |
1 |
|
|
28V power supply for TCCD |
Kniel CP28.2 |
1 |
|
|
Motion Controller |
MACCON MAC4-INC |
1 |
|
|
Servo Amplifier |
ESO VME4SA-01 |
1 |
|
|
+5V +/-15V Supply |
KNIEL CPM 101 |
1 |
This ICD specifies to use the couple ESO VME4SA servo amplifier and MACCON MAC4-INC motion controller (both supplied by ESO) for the implementation of the control of the FSS Filter Wheel, FSS Field Diaphragm and the FSS Translation Stage X- & Y-axes.
This LCU is responsible for:
|
Device |
Terminal Block |
|
Z12 |
|
|
Z16 & Z17 |
|
E |
The field acquisition system, the field stabilization system and the M6 drives and the Field Diaphragm as shown on the Figure below belong to the ESO delivery. There is for those parts only a mechanical interface existing (see 6.3). |
|
E |
Device |
Connection |
|
Field Acquisition System (FAS) |
Y31 |
|
|
See [AD 03] |
||
|
M6 (to be replaced by Deformable Mirror) |
Y33 |
|
|
Y34 |
||
|
Y35 |
||
|
Power Supplies +5VDC +/-15VDC & 28VDC |
Y31 |
|
|
Future Device |
|
|
|
Adaptive Optics LCU |
For safety and maintenance purpose, a flow-meter is installed in the liquid cooling circuit. This device can detect rapidly any leak or obstruction in the cooling pipes.
![[Sensor LCU]](Images/DcsLCU.gif)