Service modules

They control and/or monitor the status of:

Service modules interfaces:

Item From To Signal Description Pin
COMMUNICATION:
1 ATS LCU Power, Hydraulic & Pneumatic Systems RS232 Port to Siemens PLC - Protocol RK512/3964R W42
2 ATS LCU Liquid Cooling Module RS232 Port to Sauter PLC - Protocol details in [RD 10] TBD W41

 

 

E
S
O
Item From To Signal Description Pin
3     Flow Meter monitoring Digital I/O Y35

 

Item From To Signal Description Pin
AUXILIARY POWER:
10 ATS LCU main power status contact open if undervoltages on power line from station plug Software Command to W42
11 ATS LCU Battery status contact open if battery is NOT OK
Digital Input
HYDRAULIC & PNEUMATIC SYSTEMS:
20 LCU ATS Hydraulic System control Switch On/Off if control panel button is in Remote position Software Command to W42
21 ATS LCU Hydraulic System status  
22 LCU ATS Pneumatic System control Switch On/Off if control panel button is in Remote position
23 ATS LCU Pneumatic System status  
LIQUID COOLING MODULE:
30 ATS LCU LCM Status Complete LCM status
and Liquid cooling Temperature
Software Command to W41
E
S
O
31 LCU ATS Flow-meter + +24VDC, Y35_1
32 ATS LCU Flow-meter signal Frequency as a function of flow Y35_2
33     Shield (Y35_1 - Y35_2)   Y35_3

 


Last modified: Wed Jan 150 10:20:44 MET 2003