NACO AGPM CALCHECKER calibration cascade

DFOS_OPS | CALCHECKER | CALSELECTOR (current) || select other instrument: OCA
OCA rule set:NACO.RLS
Type of rule set:CALCHECKER (no DO_CLASS defined; no gencalibs, no HC calibs defined; validity indicated)
Sub-cascades: ALL       IMG | SAM | POL | WIRE | SPEC | AGPM | COR | SDI | FPI
General comment:annular grooev phase mask (since 2012-11)

Mouse over ...
- a RAW_TYPE to see the classification rule (M marks a multiple definition)
- a grouping rule to see the complete grouping rule
- a matching rule (e.g. '1,1') to see the product matching rule.
Product tags etc. might be cut off, in that case mouse over the cell to see the full entry.
|| 7.0  validity (max. accepted mjd_obs time difference) for this match

bottom | right left     
RAW_TYPEDARK LIMGFLAT TIMGFLAT SCI_AGPM SCI_AGPM_CUBE
CATGCALIB CALIB CALIB SCIENCE SCIENCE
Grouping rule TPL_A TPL_A TPL_A TPL_A TPL_A
Index12345

Calibration cascade:
 calib matches:
  1 DARK   0,1 1,1 || 1 1,1 || 1
    2 LIMGFLAT   0,1 || 1 0,1 || 1
      3 TIMGFLAT 0,1 || 14 1,1 || 14

Comments:
  includes window read out darks and cube mode darks There are no L-band and no M-band lamp flats required for L-band and M-band, HJK-bands use lamp flats instead imaging with annular groove phase mask imaging with annular groove phase mask and cube read out mode

Analysis (technical consistency checks):
products* (CALIB only) OK OK OK n/a n/a
mcalibs** n/a n/a OK OK OK
powered by QC [createCalibMap v2.1.1] last update: 2019-05-24T08:39:12
*products: does raw_type have a product? (CALIB only)
**mcalibs: are all required mcalibs, per raw_type, somewhere listed as products?
top