Health Check monitor


Agora | CAL | HC | refs | QC
HealthCheck Monitor
    HOME | UsersGuide
ISAAC:
opt.dist.pixel.SW
Other HC:
QC links:
[best viewing with style sheets and javascript enabled]
ISAAC trending system: HEALTH CHECK plot
Last update: 2008-10-10T23:29:22 (UT)
now: 2008-10-12T14:15:22 (UT)
INFO USERS-GUIDE MORE
same group: SW_LR_SZ SW_LR_J SW_LR_SH SW_LR_SK   SW_MR_SZ SW_MR_J SW_MR_SH SW_MR_SK
no OPSLOG data
 
Print: Information and research: News:
- png file  
Plot
[info]
Symbol
[info]
Source* OPS?** Average [info] Thresholds [info] N_data Data downloads Remarks
method value unit method value
1 +LOCAL   none   ADU none   15 n/a optical distortion in pixel 256,768 as derived from Argon lamp
1 xLOCAL   none   ADU none   0 n/a optical distortion in pixel 256,768 as derived from Xenon lamp
2 +LOCAL   none   ADU none   15 n/a optical distortion in pixel 768,768 as derived from Argon lamp
2 xLOCAL   none   ADU none   0 n/a optical distortion in pixel 768,768 as derived from Xenon lamp
3 +LOCAL   none   ADU none   15 n/a optical distortion in pixel 512,512 as derived from Argon lamp
3 xLOCAL   none   ADU none   0 n/a optical distortion in pixel 512,512 as derived from Xenon lamp
4 +LOCAL   none   ADU none   15 n/a optical distortion in pixel 256,256 as derived from Argon lamp
4 xLOCAL   none   ADU none   0 n/a optical distortion in pixel 256,256 as derived from Xenon lamp
5 +LOCAL   none   ADU none   15 n/a optical distortion in pixel 768,256 as derived from Argon lamp
5 xLOCAL   none   ADU none   0 n/a optical distortion in pixel 768,256 as derived from Xenon lamp
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate if OPSLOG data are included
This plot

This is the trending plot for the ISAAC arc lamp calibrations of the SW-arm, LR-grating

QC parameters have not been calculated by the pipeline, but by post-pipeline QC scripts, hence there are no on-line pipeline results to be included in the plot.

Optical distortion coefficients for setup SW, LR, SZ as derived from the arc recipe are applied to five selected pixel of the detetcor: These plots describe the optical distortion correction in x-direction applied to:
Fig. 1. center of UL quadrant: Pixel [256,768]
Fig. 2. center of UR quadrant: Pixel [768,768]
Fig. 3. center of detector CC: Pixel [513,513]
Fig. 4. center of LL quadrant: Pixel [256,256]
Fig. 5. center of LR quadrant: Pixel [768,768]

Find more information about ISAAC QC parameters derived from arc lamp frames here.

 


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up