====> file NACO.2002-11-26T09:23:16.709.fits (main) <==== SIMPLE = T / Standard FITS (NOST-100-2.0) BITPIX = -32 / # of bits per pix value NAXIS = 2 / # of axes in data array NAXIS1 = 512 / # of pixels in NAXIS2 = 512 / # of pixels in ORIGIN = 'ESO-PARANAL' / European Southern Observatory DATE = '2002-11-26T09:23:27.9426' / Date this file was written EXPTIME = 0.056 / Integration time MJD-OBS = 52604.39116561 / Obs start DATE-OBS= '2002-11-26T09:23:16.7087' / Observing date ORIGFILE= 'NACO_0256.fits' / Original File Name INSTRUME= 'NAOS+CONICA' / Instrument used TELESCOP= 'ESO-VLT-U4' / ESO RA = 83.810569 / 05:35:14.5 RA (J2000) pointing DEC = -5.37337 / -05:22:24.1 DEC (J2000) pointing EQUINOX = 2000. / Standard FK5 RADECSYS= 'FK5 ' / FK5 LST = 32529.659 / 09:02:09.659 LST UTC = 33794.000 / 09:23:14.000 UTC OBSERVER= 'UNKNOWN ' / Name of observer PI-COI = 'R.Lenzen & G.Rousset' / Name(s) of proposer(s) OBJECT = 'Object name not set' / Target description AIRMASS = 1.66400 / Averaged air mass CRVAL1 = 83.81057 / Coordinate at reference pixel in CRPIX2 = 565.0 / Ref pixel in PCOUNT = 0 / Number of parameters per group GCOUNT = 1 / Number of groups CDELT1 = -0.00000800 / Increment in CDELT2 = 0.00000800 / Increment in CTYPE1 = 'RA---TAN' / Coordinate system of CTYPE2 = 'DEC--TAN' / Coordinate system of CD1_1 = -8.00000E-06 / Translation matrix element CD1_2 = -0.00000E+00 / Translation matrix element CD2_1 = 0.00000E+00 / Translation matrix element CD2_2 = 8.00000E-06 / Translation matrix element EXTEND = T / FITS Extension may be present HIERARCH ESO OBS DID = 'ESO-VLT-DIC.OBS-1.7' / OBS Dictionary HIERARCH ESO OBS OBSERVER = 'UNKNOWN ' / Observer Name HIERARCH ESO OBS EXECTIME = 3275 / Expected execution time HIERARCH ESO OBS PI-COI NAME = 'UNKNOWN ' / PI-COI name HIERARCH ESO OBS PI-COI ID = 567 / ESO internal PI-COI ID HIERARCH ESO OBS TARG NAME = 'BNSE ' / OB target name HIERARCH ESO OBS GRP = '0 ' / linked blocks HIERARCH ESO OBS NAME = 'BNKL_M ' / OB name HIERARCH ESO OBS ID = 200123744 / Observation block ID HIERARCH ESO OBS PROG ID = '70.C-0565(A)' / ESO program identification HIERARCH ESO OBS START = '2002-11-26T09:04:03' / OB start time HIERARCH ESO OBS TPLNO = 2 / Template number within OB HIERARCH ESO TPL DID = 'ESO-VLT-DIC.TPL-1.4' / Data dictionary for TPL HIERARCH ESO TPL ID = 'NACO_img_obs_AutoJitter' / Template signature ID HIERARCH ESO TPL NAME = 'OBS Imaging: Take a series of images with relat' HIERARCH ESO TPL PRESEQ = 'cnoseqImgObsAutoJitter' / Sequencer script HIERARCH ESO TPL START = '2002-11-26T09:04:04' / TPL start time HIERARCH ESO TPL VERSION = '@(#) $Revision: 1.49 $' / Version of the templat HIERARCH ESO TPL NEXP = 40 / Number of exposures within templat HIERARCH ESO TPL EXPNO = 33 / Exposure number within template HIERARCH ESO SEQ RELOFFSETX = -75.000000 / relative X offset HIERARCH ESO SEQ RELOFFSETY = -3.000000 / relative Y offset HIERARCH ESO SEQ CUMOFFSETX = -16.000000 / cummulative X offset HIERARCH ESO SEQ CUMOFFSETY = -64.000000 / cummulative Y offset HIERARCH ESO SEQ NEXPO = 1 / Number of exposures at each offset HIERARCH ESO SEQ NOFF = 40 / Number of offsets HIERARCH ESO SEQ JITTER WIDTH= 4.000000 / Box Size for random offsets in aut HIERARCH ESO SEQ POISSON = 10 / Homogeneity factor for Poisson ran HIERARCH ESO DPR TYPE = 'OBJECT ' / Observation type HIERARCH ESO DPR TECH = 'IMAGE ' / Observation technique HIERARCH ESO DPR CATG = 'SCIENCE ' / Observation category HIERARCH ESO TEL DID = 'ESO-VLT-DIC.TCS' / Data dictionary for TEL HIERARCH ESO TEL ID = 'v 1.443+' / TCS version number HIERARCH ESO TEL DATE = '2002-09-09T15:06:41.000' / TCS installation date HIERARCH ESO TEL ALT = 36.888 / Alt angle at start (deg) HIERARCH ESO TEL AZ = 102.421 / Az angle at start (deg) S=0,W=90 HIERARCH ESO TEL GEOELEV = 2648. / Elevation above sea level (m) HIERARCH ESO TEL GEOLAT = -24.6253 / Tel geo latitute (+=North) (deg) HIERARCH ESO TEL GEOLON = -70.4022 / Tel geo longitute (+=East) (deg) HIERARCH ESO TEL OPER = 'I, Condor' / Telescope Operator HIERARCH ESO TEL FOCU ID = 'NB ' / Telescope focus station ID HIERARCH ESO TEL FOCU LEN = 120.000 / Focal length (m) HIERARCH ESO TEL FOCU SCALE = 1.718 / Focal scale (arcsec/mm) HIERARCH ESO TEL FOCU VALUE = -31.537 / M2 setting (mm) HIERARCH ESO TEL PARANG START= 116.912 / Parallactic angle at start (deg) HIERARCH ESO TEL AIRM START = 1.663 / Airmass at start HIERARCH ESO TEL AMBI FWHM START= -1.00 / Observatory Seeing queried from AS HIERARCH ESO TEL AMBI PRES START= 742.50 / Observatory ambient air pressure q HIERARCH ESO TEL AMBI WINDSP = 3.45 / Observatory ambient wind speed que HIERARCH ESO TEL AMBI WINDDIR= 346. / Observatory ambient wind directio HIERARCH ESO TEL AMBI RHUM = 12. / Observatory ambient relative humi HIERARCH ESO TEL AMBI TEMP = 14.21 / Observatory ambient temperature qu HIERARCH ESO TEL MOON RA = 92815.630846 / ~~:~~:~~.~ RA (J2000) (deg) HIERARCH ESO TEL MOON DEC = 205107.49556 / ~~:~~:~~.~ DEC (J2000) (deg) HIERARCH ESO TEL TH M1 TEMP = 13.02 / M1 superficial temperature HIERARCH ESO TEL TRAK STATUS = 'NORMAL ' / Tracking status HIERARCH ESO TEL DOME STATUS = 'FULLY-OPEN' / Dome status HIERARCH ESO TEL CHOP ST = F / True when chopping is active HIERARCH ESO TEL PARANG END = 116.898 / Parallactic angle at end (deg) HIERARCH ESO TEL AIRM END = 1.665 / Airmass at end HIERARCH ESO TEL AMBI FWHM END= -1.00 / Observatory Seeing queried from AS HIERARCH ESO TEL AMBI PRES END= 742.50 / Observatory ambient air pressure q HIERARCH ESO ADA ABSROT START= 24.94939 / Abs rot angle at exp start (deg) HIERARCH ESO ADA POSANG = 0.00000 / Position angle at start HIERARCH ESO ADA GUID STATUS = 'ON ' / Status of autoguider HIERARCH ESO ADA GUID RA = 83.750560 / 05:35:00.1 Guide star RA J2000 HIERARCH ESO ADA GUID DEC = -5.42121 / -05:25:16.3 Guide star DEC J2000 HIERARCH ESO ADA ABSROT END = 25.01089 / Abs rot angle at exp end (deg) HIERARCH ESO INS SWSIM = 'NORMAL ' / Software simulated functions HIERARCH ESO INS ID = 'CONICA/HW 1.0/SW 1.47/' / Instrument identificat HIERARCH ESO INS STIME = '2002-11-26T09:23:29.867' / Acquired status time HIERARCH ESO INS DID = 'ESO-VLT-DIC.CONICA_ICS-0.10' / Data dictionary f HIERARCH ESO INS SOFW OPSMODE= 'NORMAL ' / ICS operational mode HIERARCH ESO INS PIXSCALE = 0.027100 / Pixel scale HIERARCH ESO INS XFLIP = F / Image flipped in X by optic. HIERARCH ESO INS CWLEN = 4.7800 / Central instrument wavelength HIERARCH ESO INS TEMP-MON TEMP1= 76.00 / Status temperature scanner HIERARCH ESO INS TEMP-MON NAME1= 'CstrMiddle' / Sensor placement HIERARCH ESO INS TEMP-MON TEMP2= 81.40 / Status temperature scanner HIERARCH ESO INS TEMP-MON NAME2= 'CstrFront' / Sensor placement HIERARCH ESO INS TEMP-MON TEMP3= 56.14 / Status temperature scanner HIERARCH ESO INS TEMP-MON NAME3= 'CstrBack' / Sensor placement HIERARCH ESO INS TEMP-MON TEMP4= 286.81 / Status temperature scanner HIERARCH ESO INS TEMP-MON NAME4= 'Instr Rack' / Sensor placement HIERARCH ESO INS TEMP FPI = 85.924 / Temperature of FPI HIERARCH ESO INS TEMP DET = 27.000 / Temperature of detector HIERARCH ESO INS FPI LAMBDA = 2092.41 / FPI Wavelength (nm) HIERARCH ESO INS FPI N = 39 / FPI order HIERARCH ESO INS FPI Z = 0 / FPI Z-position value. HIERARCH ESO INS FPI Y = -9999 / FPI Y-position value. HIERARCH ESO INS FPI X = -9999 / FPI X-position value. HIERARCH ESO INS PRES-MON PRES1= 0.000 / Status pressure scanner HIERARCH ESO INS PRES-MON NAME1= 'Pressure' / Pressure position HIERARCH ESO INS LAMP1 NAME = 'penray lamp' / Calibration lamp name HIERARCH ESO INS LAMP1 TYPE = 'DIGITAL ' / Calibration lamp type HIERARCH ESO INS LAMP1 ST = F / Calibration lamp activated HIERARCH ESO INS LAMP2 NAME = 'halogen lamp' / Calibration lamp name HIERARCH ESO INS LAMP2 TYPE = 'ANALOG ' / Calibration lamp type HIERARCH ESO INS LAMP2 SET = 0 / Value sent to amplifier. HIERARCH ESO INS LAMP2 CURRENT= 0 / Amplifier status current HIERARCH ESO INS BFOCUS = 0.000000 / Telescope focus offset ordered HIERARCH ESO INS FOCUS ENC = 34000 / CONICA instrument focus HIERARCH ESO INS TADC TYPE = 'NONE ' / TADC action selection and state. HIERARCH ESO INS TADC WLENGTH= 0.0000 / Wavelength for focus correction. HIERARCH ESO INS TADC PHINF = 0.000 / Nasmyth flange rotation angle. HIERARCH ESO INS TADC ZDIST = 0.00 / Zenith distance of TADC pos. HIERARCH ESO INS ADC1 POS = 0.00 / ADCi offset from Zenith position HIERARCH ESO INS ADC2 POS = 0.00 / ADCi offset from Zenith position HIERARCH ESO INS GRP ID = 'open ' / Configuration ID of element HIERARCH ESO INS GRP NAME = 'open ' / Configuration name of element. HIERARCH ESO INS GRP NO = 3 / GRP slot number HIERARCH ESO INS GRP TYPE = 'FREE ' / Configuration TYPE of element HIERARCH ESO INS OPTI1 ID = 'FLM_27 ' / Unique element ID. HIERARCH ESO INS OPTI1 NAME = 'FLM_27 ' / Name of element. HIERARCH ESO INS OPTI1 NO = 14 / OPTIi slot number HIERARCH ESO INS OPTI1 TYPE = 'MASK ' / Type of element in OPTIi HIERARCH ESO INS OPTI2 ID = 'open ' / Unique element ID. HIERARCH ESO INS OPTI2 NAME = 'open ' / Name of element. HIERARCH ESO INS OPTI2 NO = 1 / OPTIi slot number HIERARCH ESO INS OPTI2 TYPE = 'FREE ' / Type of element in OPTIi HIERARCH ESO INS OPTI3 ID = 'Full ' / Unique element ID. HIERARCH ESO INS OPTI3 NAME = 'Full ' / Name of element. HIERARCH ESO INS OPTI3 NO = 2 / OPTIi slot number HIERARCH ESO INS OPTI3 TYPE = 'FILTER ' / Type of element in OPTIi HIERARCH ESO INS OPTI4 ID = 'empty ' / Unique element ID. HIERARCH ESO INS OPTI4 NAME = 'empty ' / Name of element. HIERARCH ESO INS OPTI4 NO = 16 / OPTIi slot number HIERARCH ESO INS OPTI4 TYPE = 'FREE ' / Type of element in OPTIi HIERARCH ESO INS OPTI5 ID = 'empty ' / Unique element ID. HIERARCH ESO INS OPTI5 NAME = 'empty ' / Name of element. HIERARCH ESO INS OPTI5 NO = 21 / OPTIi slot number HIERARCH ESO INS OPTI5 TYPE = 'FREE ' / Type of element in OPTIi HIERARCH ESO INS OPTI6 ID = 'M_prime ' / Unique element ID. HIERARCH ESO INS OPTI6 NAME = 'M_prime ' / Name of element. HIERARCH ESO INS OPTI6 NO = 7 / OPTIi slot number HIERARCH ESO INS OPTI6 TYPE = 'FILTER ' / Type of element in OPTIi HIERARCH ESO INS OPTI7 ID = 'L27 ' / Unique element ID. HIERARCH ESO INS OPTI7 NAME = 'L27 ' / Name of element. HIERARCH ESO INS OPTI7 NO = 7 / OPTIi slot number HIERARCH ESO INS OPTI7 TYPE = 'OBJECTIVE' / Type of element in OPTIi HIERARCH ESO INS MODE = 'IMAGING ' / Instrument macro setup. HIERARCH ESO DET FRAM TYPE = 'INT ' / Frame type HIERARCH ESO DET FRAM NO = 1 / Frame number HIERARCH ESO DET FRAM UTC = '2002-11-26T09:23:27.8547' / Time Recv Frame HIERARCH ESO DET EXP NO = 4416 / Exposure Number HIERARCH ESO DET EXP UTC = '2002-11-26T09:23:27.9426' / File Creation Time HIERARCH ESO DET EXP NAME = 'NACO_0256' / Exposure Name HIERARCH ESO DET DID = 'ESO-VLT-DIC.IRACE-1.23' / Dictionary Name and Re HIERARCH ESO DET CON OPMODE = 'NORMAL ' / Operational Mode HIERARCH ESO DET IRACE SEQCONT= T / Sequencer Cont. Mode HIERARCH ESO DET CHIP ID = 'ESO-Aladdin' / Detector ID HIERARCH ESO DET CHIP NAME = 'AladdinIRD02' / Detector name HIERARCH ESO DET CHIP NX = 1024 / Pixels in X HIERARCH ESO DET CHIP NY = 1024 / Pixels in Y HIERARCH ESO DET CHIP TYPE = 'IR ' / The Type of Det Chip HIERARCH ESO DET CHIP PXSPACE= 2.700e-05 / Pixel-Pixel Spacing HIERARCH ESO DET DIT = 0.0556 / Integration Time HIERARCH ESO DET NCORRS = 1 / Read-Out Mode HIERARCH ESO DET NCORRS NAME = 'Uncorr ' / Read-Out Mode Name HIERARCH ESO DET MODE NAME = 'HighSensitivity' / DCS Detector Mode HIERARCH ESO DET NDIT = 200 / # of Sub-Integrations HIERARCH ESO DET NDITSKIP = 0 / DITs skipped at 1st.INT HIERARCH ESO DET CHOP NCYCLES= 4 / # of Chop Cycles HIERARCH ESO DET CHOP CYCSKIP= 0 / # of Chop Cycles to Skip HIERARCH ESO DET CHOP ST = F / Chopping On/Off HIERARCH ESO DET RSPEED = 4 / Read-Speed Factor HIERARCH ESO DET RSPEEDADD = 0 / Read-Speed Add HIERARCH ESO DET WIN TYPE = 1 / Win-Type: 0=SW/1=HW HIERARCH ESO DET WIN STARTX = 257.000000 / Lower Left X Ref HIERARCH ESO DET WIN STARTY = 257.000000 / Lower left Y Ref HIERARCH ESO DET WIN NX = 512 / # of Pixels in X HIERARCH ESO DET WIN NY = 512 / # of Pixels in Y HIERARCH ESO DET IRACE ADC1 NAME= 'CONICA-ADC' / Name for ADC Board HIERARCH ESO DET IRACE ADC1 HEADER= 0 / Header of ADC Board HIERARCH ESO DET IRACE ADC1 ENABLE= 1 / Enable ADC Board (0/1) HIERARCH ESO DET IRACE ADC1 FILTER1= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC1 FILTER2= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC1 DELAY= 7 / ADC Delay Adjustment HIERARCH ESO DET IRACE ADC2 NAME= 'CONICA-ADC' / Name for ADC Board HIERARCH ESO DET IRACE ADC2 HEADER= 0 / Header of ADC Board HIERARCH ESO DET IRACE ADC2 ENABLE= 1 / Enable ADC Board (0/1) HIERARCH ESO DET IRACE ADC2 FILTER1= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC2 FILTER2= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC2 DELAY= 7 / ADC Delay Adjustment HIERARCH ESO DET IRACE ADC3 NAME= 'CONICA-ADC' / Name for ADC Board HIERARCH ESO DET IRACE ADC3 HEADER= 0 / Header of ADC Board HIERARCH ESO DET IRACE ADC3 ENABLE= 1 / Enable ADC Board (0/1) HIERARCH ESO DET IRACE ADC3 FILTER1= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC3 FILTER2= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC3 DELAY= 7 / ADC Delay Adjustment HIERARCH ESO DET IRACE ADC4 NAME= 'CONICA-ADC' / Name for ADC Board HIERARCH ESO DET IRACE ADC4 HEADER= 0 / Header of ADC Board HIERARCH ESO DET IRACE ADC4 ENABLE= 1 / Enable ADC Board (0/1) HIERARCH ESO DET IRACE ADC4 FILTER1= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC4 FILTER2= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC4 DELAY= 7 / ADC Delay Adjustment HIERARCH ESO DET IRACE ADC5 NAME= 'CONICA-ADC' / Name for ADC Board HIERARCH ESO DET IRACE ADC5 HEADER= 0 / Header of ADC Board HIERARCH ESO DET IRACE ADC5 ENABLE= 1 / Enable ADC Board (0/1) HIERARCH ESO DET IRACE ADC5 FILTER1= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC5 FILTER2= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC5 DELAY= 7 / ADC Delay Adjustment HIERARCH ESO DET IRACE ADC6 NAME= 'CONICA-ADC' / Name for ADC Board HIERARCH ESO DET IRACE ADC6 HEADER= 0 / Header of ADC Board HIERARCH ESO DET IRACE ADC6 ENABLE= 1 / Enable ADC Board (0/1) HIERARCH ESO DET IRACE ADC6 FILTER1= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC6 FILTER2= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC6 DELAY= 7 / ADC Delay Adjustment HIERARCH ESO DET IRACE ADC7 NAME= 'CONICA-ADC' / Name for ADC Board HIERARCH ESO DET IRACE ADC7 HEADER= 0 / Header of ADC Board HIERARCH ESO DET IRACE ADC7 ENABLE= 1 / Enable ADC Board (0/1) HIERARCH ESO DET IRACE ADC7 FILTER1= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC7 FILTER2= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC7 DELAY= 7 / ADC Delay Adjustment HIERARCH ESO DET IRACE ADC8 NAME= 'CONICA-ADC' / Name for ADC Board HIERARCH ESO DET IRACE ADC8 HEADER= 0 / Header of ADC Board HIERARCH ESO DET IRACE ADC8 ENABLE= 1 / Enable ADC Board (0/1) HIERARCH ESO DET IRACE ADC8 FILTER1= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC8 FILTER2= 0 / ADC Filter Adjustment HIERARCH ESO DET IRACE ADC8 DELAY= 7 / ADC Delay Adjustment HIERARCH ESO DET MINDIT = 0.0556 / Minimum DIT HIERARCH ESO DET VOLT1 CLKHINM1= 'clk1Hi CkFSync' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI1= -0.5000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT1= -0.4932 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM1= 'clk1Lo CkFSync' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO1= -6.0000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT1= -6.0059 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM2= 'clk2Hi CkF1' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI2= -0.5000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT2= -0.5957 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM2= 'clk2Lo CkF1' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO2= -6.0000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT2= -5.8789 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM3= 'clk3Hi CkF2' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI3= -0.5000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT3= -0.5908 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM3= 'clk3Lo CkF2' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO3= -6.0000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT3= -5.8887 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM4= 'clk4Hi CkSSync' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI4= -0.5000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT4= -0.4932 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM4= 'clk4Lo CkSSync' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO4= -6.0000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT4= -6.0107 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM5= 'clk5Hi CkS1' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI5= -0.5000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT5= -0.4932 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM5= 'clk5Lo CkS1' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO5= -6.0000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT5= -5.9814 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM6= 'clk6Hi CkS2' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI6= -0.5000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT6= -0.4980 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM6= 'clk6Lo CkS2' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO6= -6.0000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT6= -5.9717 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM7= 'clk7Hi CkS_O/E' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI7= -0.5000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT7= -0.4980 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM7= 'clk7Lo CkS_O/E' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO7= -6.0000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT7= -5.9668 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM8= 'clk8Hi VRST_R' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI8= -3.0000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT8= -2.9688 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM8= 'clk8Lo VRST_R' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO8= -6.0000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT8= -6.0059 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM9= 'clk9Hi VRST_G' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI9= -3.0000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT9= -2.9688 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM9= 'clk9Lo VRST_G' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO9= -6.0000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT9= -6.0107 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM10= 'clk10Hi CkR_DES' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI10= -0.5000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT10= -0.4932 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM10= 'clk10Lo CkR_DES' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO10= -6.0000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT10= -6.0107 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM11= 'clk11Hi VROW_ON' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI11= 0.0000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT11= 0.0049 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM11= 'clk11Lo VROW_ON' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO11= -6.2000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT11= -6.1377 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM12= 'clock12Hi VnRow' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI12= -6.5000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT12= -6.5137 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM12= 'clock12Lo VnRow' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO12= -6.5000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT12= -6.4404 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM13= 'clock13Hi VnCol' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI13= -6.4000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT13= -6.4355 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM13= 'clock13Lo VnCol' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO13= -6.4000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT13= -6.3232 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM14= 'clock14Hi' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI14= 0.0000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT14= 0.0098 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM14= 'clock14Lo' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO14= 0.0000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT14= 0.0049 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM15= 'clock15Hi' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI15= 0.0000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT15= 0.0049 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM15= 'clock15Lo' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO15= 0.0000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT15= 0.0049 / Tel Value Low Clock HIERARCH ESO DET VOLT1 CLKHINM16= 'clock16Hi' / Name of High Clock HIERARCH ESO DET VOLT1 CLKHI16= 0.0000 / Set Value High Clock HIERARCH ESO DET VOLT1 CLKHIT16= 0.0098 / Tel Value High Clock HIERARCH ESO DET VOLT1 CLKLONM16= 'clock16Lo' / Name of Low Clock HIERARCH ESO DET VOLT1 CLKLO16= 0.0000 / Set Value Low Clock HIERARCH ESO DET VOLT1 CLKLOT16= 0.0049 / Tel Value Low Clock HIERARCH ESO DET VOLT1 DCNM1 = 'DC1 VDETCOM' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC1 = -3.6000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA1 = -3.6035 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB1 = -3.5693 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM2 = 'DC2 VddUc' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC2 = -3.8000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA2 = -3.8086 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB2 = -3.6963 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM3 = 'DC3 VddCl' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC3 = -1.5000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA3 = -1.4990 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB3 = -1.4844 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM4 = 'DC4 VddOut' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC4 = -1.3000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA4 = -1.2988 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB4 = -1.0645 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM5 = 'DC5 VggCl' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC5 = -2.0000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA5 = -1.9971 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB5 = -1.9775 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM6 = 'DC6 Iref (250K to)' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC6 = -2.5000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA6 = -2.5000 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB6 = -2.4756 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM7 = 'DC7 VLoad' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC7 = 2.0000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA7 = 2.0068 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB7 = 1.7676 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM8 = 'DC8 VTest' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC8 = -3.6000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA8 = -3.6035 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB8 = -3.5693 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM9 = 'DC9 REF1' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC9 = -1.0000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA9 = -0.9961 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB9 = -0.9814 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM10= 'DC10 REF2' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC10 = -1.0000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA10= -0.9961 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB10= -0.9814 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM11= 'DC11 REF3' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC11 = -1.0000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA11= -0.9912 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB11= -0.9814 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM12= 'DC12 REF4' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC12 = -1.0000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA12= -0.9961 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB12= -0.9814 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM13= 'DC13 ' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC13 = 0.0000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA13= 0.0098 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB13= 0.0098 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM14= 'DC14 ' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC14 = 0.0000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA14= 0.0098 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB14= 0.0098 / Tel Value 2 for DC HIERARCH ESO DET VOLT1 DCNM15= 'DC15 ' / Name of DC Voltage HIERARCH ESO DET VOLT1 DC15 = 0.0000 / Set Value DC Voltage HIERARCH ESO DET VOLT1 DCTA15= 0.0098 / Tel Value 1 for DC HIERARCH ESO DET VOLT1 DCTB15= 0.0098 / Tel Value 2 for DC HIERARCH ESO DET CHOP FREQ = 0.000000 / Chopping Frequency HIERARCH ESO AOS RTC DET WFS MODE= '2-1 ' / Wavefront sensor mode HIERARCH ESO AOS RTC DET ADAO NBRESET= 0 / Nb. AO control resets HIERARCH ESO AOS RTC DET DST L0MEAN= 0.00 / Average value of L0 HIERARCH ESO AOS RTC DET DST R0MEAN= 0.0 / Average value of R0 HIERARCH ESO AOS RTC DET DST T0MEAN= 0.0 / Average value of T0 HIERARCH ESO AOS RTC DET DST NOISMEAN= 0.000000 / Average value of noise of vari HIERARCH ESO AOS RTC DET DST ECMEAN= 0.0 / Average value of coherent energy HIERARCH ESO AOS RTC DET DST FLUXMEAN= 0. / Average value of reference source HIERARCH ESO AOS RTC DET DST TTMXMEAN= -1.936 / Average value of TTMX along an e HIERARCH ESO AOS RTC DET DST TTMYMEAN= 0.020 / Average value of TTMY along an ex HIERARCH ESO AOS RTC DET ADAO ST= T / AO correction activated HIERARCH ESO AOS IR DET WFS MODE= '2-1 ' / Wavefront sensor mode HIERARCH ESO AOS IR INS FILT POSNAM= 'IJHK ' / Motor FILT named position HIERARCH ESO AOS INS CON POSANG= -1.0000 / Instrument orientation on NAOS HIERARCH ESO AOS INS PSCALE = 1.780 / Plate scale HIERARCH ESO AOS INS ALPH ABSPOS= -8.220548 / Alpha coordinate HIERARCH ESO AOS INS DELT ABSPOS= 4.464036 / Delta coordinate HIERARCH ESO AOS INS FOCU ABSPOS= 4.000000 / Focus value HIERARCH ESO AOS INS DABE ST = F / Correction of static aberrations f HIERARCH ESO AOS INS DABE XAXIS= 0.1920 / Value of scientific instrument abe HIERARCH ESO AOS INS DABE YAXIS= 0.2160 / Value of scientific instrument abe HIERARCH ESO AOS INS DABE FOCUS= -1.079 / Value of scientific instrument foc HIERARCH ESO AOS INS WABE ST = F / Correction of static aberrations f HIERARCH ESO AOS INS WABE XAXIS= 0.4300 / Value of WFS aberrations on X axis HIERARCH ESO AOS INS WABE YAXIS= 0.9600 / Value of WFS aberrations on Y axis HIERARCH ESO AOS INS WABE FOCUS= 0.054 / Value of WFS focus aberrations. HIERARCH ESO AOS INS REFR ST = F / Differential refraction compensati HIERARCH ESO AOS INS TRAK ST = F / Tracking of the reference object ( HIERARCH ESO AOS INS DICH POSNAM= 'JHK ' / Motor DICH named position HIERARCH ESO AOS INS WSEL POSNAM= 'IR ' / Motor WSEL named position HIERARCH ESO AOS OCS WFS TYPE= 'IR ' / Wavefront sensor type HIERARCH ESO AOS OCS WFS MODE= '2-1 ' / Wavefront sensor mode HIERARCH ESO OCS SOS INS MODE= 'IMAGING ' / Instrument mode used ARCFILE = 'NACO.2002-11-26T09:23:16.709.fits' / Archive File Name CHECKSUM= 'lgAIng5IlgAIlg3I' / ASCII 1's complement checksum END