[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
OMEGACAM trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-05-01T16:03:15 (UT)
  | now: 2024-05-02T08:51:28 (UT) muc06 QC pipeline: omega-1.1.8 (installed 2023-06-22)
same group: non-linearity   num_NL_pixels linearity_minmax FP_noise
close window history: 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023   2024   HEALTH
  ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 990 ADU none  13 qc_counts_min this | last_yr | all minimum median flux level used in the linearity computation averaged over all 32 detectors (ADU)
1 QC1DB MEDIAN 3.51e+04 ADU none  13 qc_counts_max this | last_yr | all maximum median flux level used in the linearity computation averaged over all 32 detectors (ADU)
2 QC1DB MEDIAN 997 ADU none  416 qc_counts_min this | last_yr | all minimum median flux level used in the linearity computation for each individual detector (ADU)
2 QC1DB MEDIAN 3.53e+04 ADU none  416 qc_counts_max this | last_yr | all maximum median flux level used in the linearity computation for each individual detector (ADU)
3 LOCAL none   none none  416 det_id n/a score per detector:
GREEN = within the thresholds
3 LOCAL none   none none  0 det_id n/a score per detector:
RED = beyond the thresholds
3 LOCAL none   none none  416 det_id n/a  
3 LOCAL none   none none  0 det_id n/a  
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:omegacam_detlin
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_counts_min
median:990ADU
thresholds:none 
N_data plotted:13
[click plot for closeup]
Plot 2
scores: not implemented
data source:omegacam_detlin
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_counts_min
median:997ADU
thresholds:none 
N_data plotted:416
[click plot for closeup]
Plot 3
scores: not implemented
data source:local data source
dataset:
(numbers below apply to this dataset)
det_id
average:none
thresholds:none
N_data plotted:416
[click plot for closeup]
This plot

Trending plots for the detector linearity (minimum and maximum flux levels used in the non-linearity computation).

QC parameters are derived from each of 32 detectors of OmegaCAM dome flat frames.

DB Name: omegacam_detlin
Fits header: QC.COUNTS.MIN / QC.COUNTS.MAX
QC1 DB: qc_counts_min / qc_counts_max

Description:
The minimum and maximum flux levels of the input images used to compute the non-linear pixels as measured from the detector monitoring pipeline product BP_MAP_NL

Setup:
BIN.X / BIN.Y / READ.MODE / READ.SPEED = 1/1/normal/normal

These Health Check plots describe:
Fig. 1 min/max_flux_AVG: The minimum and maximum flux levels used to compute the effective non-linearity correction averaged over all 32 detectors. This plot is sensitive to any changes common to all detectors.
Fig. 2 min/max_flux_ALL: The minimum and maximum flux levels used to compute the effective non-linearity correction for each individual detector. This plot is sensitive changes in individual detectors.
Fig. 3 score_outliers: Scores of the effective non-linearity correction as measured for each of the 32 detectors.
Green = within the defined thresholds.
Red = beyond the defined thresholds.


OmegaCAM detector plane layout (detector_ID locations):
OmegaCAM detector layout

 
General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up