[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
OMEGACAM trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-05-05T10:04:51 (UT)
  | now: 2024-05-05T12:41:27 (UT) muc06 QC pipeline: omega-1.1.8 (installed 2023-06-22)
same group: Zpt_uSDSS Zpt_gSDSS Zpt_rSDSS Zpt_iSDSS Zpt_zSDSS   Zpt_BJOHN Zpt_VJOHN Zpt_ugriSDSS
close window history: 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023   2024   HEALTH FULL
  ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 23.6 mag VAL23.1,25.1 91 qc_zeropoint_electron this | last_yr | all u_SDSS zeropoints (computed with flux units in electrons) averaged over all 32 detectors (magnitudes)
2 QC1DB MEDIAN 0.153 mag VAL0.,0.9 139 qc_zeropoint_electron this | last_yr | all u_SDSS standard deviation of the zeropoints (magnitudes)
3 QC1DB MEDIAN 23.7 mag VAL23.1,25.1 3132 qc_zeropoint_electron this | last_yr | all u_SDSS zeropoints (computed with flux units in electrons) for each individual detector (magnitudes)
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: no current data
data source:omegacam_std
(QC1 database)
dataset:qc_zeropoint_electron
median:23.6mag
fixed thresholds:23.1...25.1mag
N_data plotted:91
[click plot for closeup]
Plot 2
scores: no current data
data source:omegacam_std
(QC1 database)
dataset:qc_zeropoint_electron
median:0.153mag
fixed thresholds:0.0...0.9mag
N_data plotted:139
[click plot for closeup]
Plot 3
scores: not implemented
data source:omegacam_std
(QC1 database)
dataset:qc_zeropoint_electron
median:23.7mag
fixed thresholds:23.1...25.1mag
N_data plotted:3132
[click plot for closeup]
This plot

Trending plots for standard zeropoints: u_SDSS .

QC parameters are derived from each of 32 detectors of OmegaCAM STD,ZEROPOINT frames.

DB Name: omegacam_std
Fits header: QC.ZEROPOINT_ELECTRON / QC.ZEROPOINT_ELECTRON.ERR
QC1 DB: qc_zeropoint_electron / qc_zeropoint_electron_err

Description:
The zeropoints are measured using flux units in electrons and are contained in the pipeline product frame ZEROPOINTS

Setup:
INS.FILT1.NAME / BIN.X / BIN.Y / READ.MODE / READ.SPEED = u_SDSS/1/1/normal/normal

These Health Check plots describe:
Fig. 1 Zpt_rSDSS_AVG: The u_SDSS zeropoints averaged over all 32 detectors. This plot is sensitive to any changes common to all detectors. Also, Paranal opslog data are included. The data from Paranal is filtered (s.t. mag.>=20.0) and averaged over the 8 detectors for which it is measured.
Fig. 2 Zpt_rSDSS_RMS: The rms of the u_SDSS zeropoints averaged over all 32 detectors.
Fig. 3 Zpt_rSDSS_ALL: The u_SDSS zeropoints for each individual detector. This plot is sensitive changes in individual detectors.

OmegaCAM detector plane layout (detector_ID locations):
OmegaCAM detector layout

 
General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up