| QC PLOTS |
| |
CURRENT |
HISTORY |
| Daily Health Checks: |
|
|
| MOS FMTCHK GratPos PhysM dX DHC |
 |
 |
| MOS FMTCHK GratPos PhysM dY DHC |
 |
 |
| MOS FMTCHK GratPos NLIN DHC |
 |
 |
| QC1 uves_fib_fmtchk database (advanced users):
browse
|
plot
|
| QC1 uves_fmtchk database (advanced users):
browse
|
plot
|
Click on CURRENT to see the last trending (Health Check).
Click on HISTORY to see the historical evolution of the trending. |
|
top
Fibre-Physical-Model-Prediction-Results |
QC1 parameters
- difference of X positions to physical model (QC1 database table uves_fib_fmtchk, column mean_dx, product keyword QC.MODEL.DIFFXAVG)
Description: The physical model used in Formatcheck step allows
to measure the difference between model predicted
and detected line positions. This is useful to verify
precision of physical model prediction and instrument
spectral format stability.
- difference of Y positions to physical model (QC1 database table uves_fib_fmtchk, column mean_dy, product keyword QC.MODEL.DIFFYAVG)
Description: The physical model used in Formatcheck step allows
to measure the difference between model predicted
and detected line positions. This is useful to verify
precision of physical model prediction and instrument
spectral format stability.
- number of lines selected (QC1 database table uves_fib_fmtchk, column nlin_sel, product keyword QC.MODEL.NLINSEL)
Description: The physical model used in the Formatcheck step allows
to predict line positions on the formatcheck frame.
The selected number of lines is the subset of the total
number of lines which fall in the physical model plot
limits.
|
top
Physical-Model-Prediction-Results |
QC1 parameters
- difference of X positions to physical model (QC1 database table uves_fmtchk, column mean_dx, product keyword QC.MODEL.DIFFXAVG)
Description: The physical model used in Formatcheck step allows
to measure the difference between model predicted
and detected line positions. This is useful to verify
precision of physical model prediction and instrument
spectral format stability.
- difference of Y positions to physical model (QC1 database table uves_fmtchk, column mean_dy, product keyword QC.MODEL.DIFFYAVG)
Description: The physical model used in Formatcheck step allows
to measure the difference between model predicted
and detected line positions. This is useful to verify
precision of physical model prediction and instrument
spectral format stability.
- number of lines selected (QC1 database table uves_fmtchk, column nlin_sel, product keyword QC.MODEL.NLINSEL)
Description: The physical model used in the Formatcheck step allows
to predict line positions on the formatcheck frame.
The selected number of lines is the subset of the total
number of lines which fall in the physical model plot
limits.
|