Wavelength      Line    Source  Strength    Comments
--------------------------------------------------------
28697.9         Ar      2       11.1
28782.9         Ar      2      108.3       
28843.1         Ar      2       19.5
29134.0         Ar      2       10.7
29262.9         Ar      2        2.4
29280.6         Ar      2        4.4
29392.3         Xe      1        7.3
29456.2         Xe      1        3.1
29796.8         Ar      2       62.2       
30261.3         Xe      1       31.8       
30462.6         Ar      2        8.5
30483.9         Xe      1      118.8       
30802.5         Xe      1       30.7       
30996.2         Ar      2        8.6        
31077.6         Xe      1      946.1       
31284.3         Xe      1        2.0
31333.0         Ar      2       74.9       
31344.6         Xe      1       10.9        
31616.7         Xe      1       36.1       
31727.8         Ar      2        7.0        
32256.3         Ar      2        6.0
32333.9         Ar      2       11.4
32747.9         Xe      1      234.8       
32888.6         Ar      2        9.8        
33078.8         Ar      2       28.4       
33148.4         Ar      2       31.0       
33293.4         Ar      2       23.4        
33675.7         Xe      1      835.0       
34023.8         Xe      1       20.1        
34084.2         Xe      1       19.7
34334.6         Xe      1       81.3       
34753.7         Xe      1       18.2
34960.5         Ar      2        5.8
35080.0         Xe      1     1833.0       
36220.8         Ar      2       45.9       
36241.8         Xe      1       10.2
36312.4         Ar      2       12.2
36492.0         Ar      2       58.0       
36518.5         Xe      1       95.3       
36798.4         Xe      1      193.6       
36858.6         Xe      1       27.8        
37013.6         Ar      2        7.7
37086.0         Ar      2       10.3
37143.5         Ar      2       29.5
37186.1         Ar      2        4.7
37291.8         Ar      2        6.9
38120.0         Ar      2       19.9       
38331.2         Ar      2       10.3
38696.9         Xe      1       14.3
38737.7         Xe      1       21.9       
38748.6         Xe      1       21.4         
38878.8         Xe      1       25.1        
38950.4         Xe      1      298.2       
38959.7         Xe      1       59.5         Blended with 38950.4      
38973.1         Xe      1       47.8
39483.9         Xe      1       25.0
39529.9         Xe      1       17.2 
39909.2         Ar      2       71.3       
39965.7         Xe      1      155.2       
40008.2         Ar      2       14.3        
40435.2         Ar      2       52.0       
40891.3         Ar      2       23.7
-------------------------------------------------



Jean Gabriel Cuby