# K filter curve @ T=90K # K # Wavelength (nm) T (%) 497.000 0.000266825 498.988 -0.000228290 500.976 0.000979493 502.964 -0.001500235 504.952 0.000150599 506.940 -0.000959903 508.928 -0.000077500 510.916 -0.000082100 512.904 -0.000478464 514.892 -0.000373631 516.880 0.000544385 518.868 0.000507415 520.856 0.000179691 522.844 -0.000640896 524.832 0.000111137 526.820 0.000598623 528.808 0.000926607 530.796 0.000531246 532.784 -0.000295818 534.772 0.000609278 536.760 0.000049500 538.748 -0.000027200 540.736 0.000339538 542.724 0.000041800 544.712 -0.000293703 546.700 0.000096500 548.688 -0.000235075 550.676 0.000543028 552.664 0.000213077 554.652 -0.000225214 556.640 0.000274730 558.628 -0.000108021 560.616 -0.000173175 562.604 0.000104298 564.592 -0.000744925 566.580 0.000031200 568.568 -0.000457618 570.556 -0.000258539 572.544 -0.000952038 574.532 -0.000642884 576.520 -0.000314157 578.508 0.000223374 580.496 -0.000708906 582.484 0.000233143 584.472 0.000805460 586.460 -0.000412907 588.448 0.000142200 590.436 -0.000313557 592.424 0.000437956 594.412 0.000339875 596.400 -0.000174910 598.388 0.000165583 600.376 -0.001063781 602.364 0.000045800 604.352 -0.000083800 606.340 0.001197710 608.328 0.000366391 610.316 -0.000411443 612.304 -0.000471024 614.292 -0.000813063 616.280 -0.000124232 618.268 0.000009890 620.256 -0.000922562 622.244 -0.000357743 624.232 0.000112120 626.220 -0.000043700 628.208 0.000170072 630.196 -0.000075100 632.184 -0.000364263 634.172 -0.000265755 636.160 -0.000689146 638.148 0.000230465 640.136 0.000120910 642.124 0.000677588 644.112 -0.000193467 646.100 0.000631569 648.088 0.000115651 650.076 -0.000030700 652.064 0.000009110 654.052 -0.000960503 656.040 0.000027400 658.028 0.000244797 660.016 -0.000153509 662.004 0.000184354 663.992 -0.000152487 665.980 0.000359169 667.968 0.000165493 669.956 0.000288220 671.944 0.000465859 673.932 0.000924555 675.920 -0.000564644 677.908 0.000447968 679.896 -0.000107676 681.884 -0.000086100 683.872 -0.000441014 685.860 -0.000574654 687.848 -0.000425932 689.836 -0.000027200 691.824 -0.000336704 693.812 0.000575999 695.800 0.000104998 697.788 0.000141905 699.776 -0.000137682 701.764 0.000246460 703.752 -0.000090200 705.740 -0.000213296 707.728 -0.000151448 709.716 0.000356485 711.704 -0.000990924 713.692 0.000187023 715.680 -0.000150930 717.668 0.000713986 719.656 -0.000074500 721.644 0.000225932 723.632 -0.000181524 725.620 0.000233449 727.608 -0.000114833 729.596 0.000621714 731.584 0.000596182 733.572 -0.000328564 735.560 -0.000434251 737.548 0.000518395 739.536 0.000228704 741.524 0.000353547 743.512 -0.000289964 745.500 -0.000222531 747.488 -0.000760328 749.476 -0.000546646 751.464 0.000045800 753.452 0.000112151 755.440 -0.000665489 757.428 -0.000053800 759.416 -0.000163701 761.404 -0.000272981 763.392 0.000089700 765.380 0.000046200 767.368 0.000415203 769.356 0.000896866 771.344 0.001003686 773.332 0.000256549 775.320 0.000036300 777.308 0.000409307 779.296 -0.000542559 781.284 -0.000608713 783.272 -0.000343823 785.260 0.000273013 787.248 -0.000024500 789.236 -0.000193102 791.224 0.001004327 793.212 -0.000950547 795.200 0.000116056 797.188 -0.000305100 799.176 -0.000205814 801.164 0.000643710 803.152 -0.000189939 805.140 0.000672052 807.128 0.000652829 809.116 -0.000250125 811.104 -0.000546007 813.092 -0.000009840 815.080 0.000536653 817.068 0.000251377 819.056 -0.000030200 821.044 -0.000153305 823.032 -0.000819575 825.020 -0.002539246 827.008 -0.003072413 828.996 -0.001990174 830.984 -0.004547140 832.972 -0.005736475 834.960 -0.002370483 836.948 -0.001156259 838.936 -0.005150869 840.924 -0.002400610 842.912 -0.002223927 844.900 -0.003240955 846.888 -0.003324352 848.876 -0.002250341 850.864 -0.003088183 852.852 -0.007194612 854.840 -0.003410840 856.828 0.001593784 858.816 0.001632051 860.804 -0.009394489 862.792 -0.006297167 864.780 -0.000576065 866.768 -0.005874760 868.756 -0.006134281 870.744 -0.009229851 872.732 -0.001839100 874.720 -0.004209063 876.708 -0.008496072 878.696 -0.006294023 880.684 -0.003738854 882.672 -0.000387679 884.660 -0.001773260 886.648 -0.004020993 888.636 -0.007120688 890.624 0.000254070 892.612 -0.004752922 894.600 -0.008816924 896.588 -0.001291478 898.576 -0.002138791 900.564 -0.002937285 902.552 -0.007988682 904.540 -0.003204504 906.528 -0.005316321 908.516 -0.004045620 910.504 -0.002175144 912.492 -0.000137332 914.480 -0.000755271 916.468 -0.003432752 918.456 -0.000222165 920.444 0.001612692 922.432 -0.007788269 924.420 -0.004876584 926.408 -0.002660249 928.396 -0.000525515 930.384 -0.007122533 932.372 0.008824370 934.360 -0.001759191 936.348 -0.006645317 938.336 -0.006934523 940.324 -0.003023655 942.312 -0.000693292 944.300 -0.005848615 946.288 -0.004245806 948.276 -0.003904926 950.264 -0.004490691 952.252 -0.003582058 954.240 -0.003264214 956.228 -0.004595858 958.216 -0.003188546 960.204 -0.002882940 962.192 -0.004936312 964.180 -0.000692723 966.168 -0.003646876 968.156 -0.004472746 970.144 -0.005430152 972.132 -0.004453406 974.120 -0.003229751 976.108 -0.006196438 978.096 -0.005154889 980.084 -0.000914397 982.072 -0.001796308 984.060 0.001472222 986.048 -0.004355677 988.036 -0.002138298 990.024 -0.006995014 992.012 -0.008074483 994.000 -0.008837654 995.988 -0.000366176 997.976 -0.003053311 999.964 -0.008358102 1001.952 0.002680433 1003.940 -0.004116969 1005.928 -0.005445580 1007.916 -0.002926475 1009.904 -0.004105057 1011.892 -0.004153478 1013.880 -0.004081131 1015.868 -0.004353099 1017.856 -0.002047910 1019.844 -0.004107201 1021.832 -0.001551450 1023.820 -0.002349587 1025.808 -0.006381662 1027.796 -0.002685077 1029.784 -0.001784679 1031.772 -0.004706248 1033.760 -0.004062518 1035.748 -0.003320701 1037.736 -0.004256614 1039.724 -0.006010878 1041.712 -0.003634616 1043.700 0.000511831 1045.688 -0.003754844 1047.676 -0.002177718 1049.664 -0.000925498 1051.652 -0.005849278 1053.640 -0.002499106 1055.628 -0.002802875 1057.616 -0.000455623 1059.604 -0.007138251 1061.592 -0.004563542 1063.580 -0.006184021 1065.568 -0.005506671 1067.556 0.001689096 1069.544 -0.001368630 1071.532 0.000144333 1073.520 -0.006041637 1075.508 -0.007043762 1077.496 0.002475685 1079.484 -0.007207651 1081.472 -0.000571671 1083.460 -0.006815726 1085.448 -0.001586154 1087.436 -0.003236764 1089.424 0.002971770 1091.412 0.000435354 1093.400 -0.006457097 1095.388 -0.002100853 1097.376 -0.004370587 1099.364 -0.003347953 1101.352 -0.005090984 1103.340 -0.004752981 1105.328 -0.002816552 1107.316 -0.009172774 1109.304 -0.008395785 1111.292 0.005359757 1113.280 -0.001445654 1115.268 0.000153414 1117.256 -0.006491985 1119.244 -0.003399353 1121.232 -0.005399177 1123.220 -0.009193334 1125.208 0.016629107 1127.196 -0.011148329 1129.184 -0.006307282 1131.172 -0.002868836 1133.160 -0.010235972 1135.148 -0.001970172 1137.136 -0.012773519 1139.124 0.009175805 1141.112 -0.001015569 1143.100 -0.004568622 1145.088 -0.007294139 1147.076 0.008383292 1149.064 -0.006372668 1151.052 -0.009873820 1153.040 -0.005173511 1155.028 0.003808816 1157.016 -0.005616788 1159.004 0.000381126 1160.992 -0.008724847 1162.980 -0.003805182 1164.968 -0.006821397 1166.956 -0.003452882 1168.944 -0.005509166 1170.932 -0.006002173 1172.920 -0.000922373 1174.908 0.000023600 1176.896 -0.004660362 1178.884 -0.002642022 1180.872 -0.003451192 1182.860 -0.009890885 1184.848 -0.002319398 1186.836 -0.003869943 1188.824 -0.000441996 1190.812 -0.003467521 1192.800 -0.003896604 1194.788 -0.003087095 1196.776 -0.002371649 1198.764 -0.003519629 1200.752 -0.004484414 1202.740 -0.000033400 1204.728 -0.000420249 1206.716 0.000347873 1208.704 -0.002358227 1210.692 -0.002748618 1212.680 -0.002753983 1214.668 -0.000057200 1216.656 -0.003928839 1218.644 -0.001198287 1220.632 -0.001186850 1222.620 -0.005384459 1224.608 -0.008483147 1226.596 -0.001762506 1228.584 0.006471670 1230.572 -0.003509137 1232.560 -0.003904913 1234.548 -0.000188636 1236.536 -0.000293586 1238.524 -0.008137319 1240.512 -0.003859818 1242.500 -0.000436248 1244.488 -0.006176141 1246.476 -0.003929924 1248.464 -0.000599774 1250.452 -0.005646608 1252.440 -0.009624935 1254.428 -0.000074000 1256.416 -0.000868617 1258.404 -0.006964677 1260.392 -0.000451520 1262.380 -0.003171898 1264.368 -0.005583122 1266.356 -0.006004682 1268.344 -0.003717580 1270.332 -0.000807272 1272.320 -0.006541378 1274.308 -0.006174490 1276.296 -0.003551753 1278.284 -0.003740080 1280.272 -0.007375079 1282.260 -0.005792514 1284.248 0.004022618 1286.236 -0.004528529 1288.224 -0.000163414 1290.212 -0.002558158 1292.200 -0.002978540 1294.188 -0.007189018 1296.176 -0.005049933 1298.164 -0.002908972 1300.152 -0.003213409 1302.140 -0.004705433 1304.128 -0.001716301 1306.116 -0.003080859 1308.104 -0.006225109 1310.092 -0.001706525 1312.080 -0.005473923 1314.068 0.000966360 1316.056 -0.003992937 1318.044 -0.001787020 1320.032 -0.005285883 1322.020 -0.005065551 1324.008 -0.004672239 1325.996 -0.008495609 1327.984 -0.000178579 1329.972 -0.002265888 1331.960 -0.009337269 1333.948 0.001311885 1335.936 -0.012352902 1337.924 0.000529458 1339.912 -0.006121727 1341.900 -0.008399236 1343.888 0.005736773 1345.876 -0.008722006 1347.864 -0.001204553 1349.852 -0.002788091 1351.840 -0.005385465 1353.828 -0.002966103 1355.816 0.002252064 1357.804 -0.009630299 1359.792 -0.006830214 1361.780 -0.002174835 1363.768 -0.006952592 1365.756 -0.004649583 1367.744 -0.004796654 1369.732 -0.003228280 1371.720 -0.003468863 1373.708 0.002192021 1375.696 -0.005494478 1377.684 0.001929015 1379.672 -0.010488303 1381.660 -0.001146058 1383.648 -0.004572685 1385.636 -0.007905819 1387.624 -0.001504859 1389.612 -0.005469119 1391.600 -0.001454015 1393.588 -0.004574980 1395.576 0.000520941 1397.564 -0.000250160 1399.552 -0.000422902 1401.540 -0.005189927 1403.528 -0.004542773 1405.516 -0.001764442 1407.504 -0.007427321 1409.492 -0.006073222 1411.480 -0.002290483 1413.468 -0.004842817 1415.456 -0.007165338 1417.444 0.001311006 1419.432 -0.003936796 1421.420 -0.002001035 1423.408 -0.005659134 1425.396 -0.004988498 1427.384 -0.011341359 1429.372 0.007220978 1431.360 -0.005249044 1433.348 0.000271990 1435.336 -0.002059932 1437.324 -0.003109566 1439.312 -0.004396909 1441.300 -0.003805325 1443.288 -0.004360266 1445.276 -0.004175987 1447.264 -0.002140437 1449.252 -0.000526258 1451.240 -0.011118490 1453.228 -0.002850377 1455.216 -0.005650871 1457.204 -0.006792956 1459.192 -0.007408255 1461.180 -0.006119282 1463.168 -0.002135371 1465.156 0.002171734 1467.144 -0.006648302 1469.132 -0.008167448 1471.120 -0.005304214 1473.108 -0.002313215 1475.096 -0.005920050 1477.084 -0.006129034 1479.072 -0.006553728 1481.060 -0.006485479 1483.048 0.002548478 1485.036 -0.001798582 1487.024 -0.004346134 1489.012 -0.002922934 1491.000 -0.002521609 1492.988 0.002546014 1494.976 -0.005531922 1496.964 -0.008101621 1498.952 -0.007510935 1500.940 -0.003967984 1502.928 0.000757237 1504.916 -0.001594834 1506.904 -0.002935949 1508.892 -0.003154065 1510.880 -0.004891410 1512.868 -0.000692503 1514.856 -0.007533822 1516.844 -0.003447880 1518.832 -0.003298277 1520.820 -0.002957801 1522.808 -0.003736680 1524.796 -0.003117381 1526.784 -0.000297124 1528.772 -0.001982112 1530.760 0.000485197 1532.748 -0.002898730 1534.736 -0.006112773 1536.724 -0.004623518 1538.712 0.006284055 1540.700 -0.015919955 1542.688 -0.002706079 1544.676 -0.001069997 1546.664 -0.004638588 1548.652 -0.002408861 1550.640 -0.000877742 1552.628 -0.001436285 1554.616 0.001161524 1556.604 -0.008698638 1558.592 -0.003697077 1560.580 -0.002591462 1562.568 -0.000340580 1564.556 -0.002269691 1566.544 -0.000799767 1568.532 -0.001014562 1570.520 -0.006454941 1572.508 -0.006321552 1574.496 -0.002784403 1576.484 -0.002976535 1578.472 -0.003318029 1580.460 -0.004897058 1582.448 -0.004489238 1584.436 0.003349381 1586.424 -0.002848378 1588.412 -0.002772521 1590.400 -0.008032778 1592.388 -0.007668227 1594.376 -0.000535481 1596.364 -0.005750151 1598.352 -0.001271165 1600.340 -0.004081135 1602.328 -0.000715429 1604.316 -0.003527871 1606.304 -0.003773251 1608.292 -0.004699353 1610.280 -0.004459729 1612.268 -0.003863803 1614.256 -0.000171297 1616.244 -0.008245510 1618.232 -0.002807142 1620.220 0.002425544 1622.208 -0.002267631 1624.196 -0.006083027 1626.184 -0.004455313 1628.172 0.001283779 1630.160 -0.005960579 1632.148 -0.001922086 1634.136 -0.001119355 1636.124 -0.006321007 1638.112 -0.003574560 1640.100 -0.009794746 1642.088 0.006199014 1644.076 -0.002097284 1646.064 -0.004124666 1648.052 0.006018543 1650.040 -0.008824843 1652.028 -0.003520238 1654.016 -0.003691602 1656.004 -0.003588653 1657.992 -0.004685394 1659.980 -0.002692329 1661.968 -0.003619298 1663.956 -0.000617143 1665.944 -0.006729049 1667.932 -0.005423227 1669.920 -0.001890218 1671.908 -0.004754063 1673.896 -0.014446552 1675.884 0.005539138 1677.872 0.000314048 1679.860 -0.003411559 1681.848 -0.005286102 1683.836 -0.002640127 1685.824 -0.000983693 1687.812 -0.000195813 1689.800 -0.004120013 1691.788 -0.006381807 1693.776 -0.005152008 1695.764 -0.001932060 1697.752 -0.002196916 1699.740 -0.001519294 1701.728 -0.006441386 1703.716 -0.008090630 1705.704 -0.005108376 1707.692 -0.004296423 1709.680 -0.002801982 1711.668 -0.004524506 1713.656 -0.002757729 1715.644 -0.003665280 1717.632 -0.008581490 1719.620 -0.001155486 1721.608 -0.002899445 1723.596 -0.005656202 1725.584 -0.003608093 1727.572 -0.003063840 1729.560 -0.003450121 1731.548 -0.003921830 1733.536 -0.001900051 1735.524 -0.004816550 1737.512 -0.001610150 1739.500 -0.010856308 1741.488 0.002494982 1743.476 -0.002913924 1745.464 -0.009391641 1747.452 0.005146610 1749.440 -0.005282921 1751.428 -0.005314431 1753.416 -0.003769092 1755.404 -0.002407359 1757.392 -0.006992782 1759.380 -0.001785797 1761.368 -0.000466093 1763.356 -0.003631928 1765.344 -0.007318879 1767.332 -0.007884965 1769.320 -0.002147290 1771.308 -0.003936835 1773.296 -0.001362111 1775.284 -0.003254570 1777.272 -0.003300523 1779.260 -0.010392698 1781.248 0.006885853 1783.236 -0.013648823 1785.224 0.001374899 1787.212 -0.003541830 1789.200 -0.004346567 1791.188 -0.001600097 1793.176 -0.004736505 1795.164 -0.008417452 1797.152 0.003841893 1799.140 0.000753883 1801.128 -0.004351865 1803.116 0.000719148 1805.104 0.000427268 1807.092 -0.001631473 1809.080 -0.000893372 1811.068 -0.001914214 1813.056 -0.001061503 1815.044 -0.002489950 1817.032 -0.005059219 1819.020 -0.002257069 1821.008 -0.003684540 1822.996 -0.005329343 1824.984 -0.003456031 1826.972 -0.003115135 1828.960 0.002038714 1830.948 -0.006564763 1832.936 -0.005194032 1834.924 -0.003087142 1836.912 -0.003676452 1838.900 -0.001083341 1840.888 -0.001920477 1842.876 -0.002468867 1844.864 -0.000656456 1846.852 -0.002960050 1848.840 -0.004379580 1850.828 -0.000926140 1852.816 -0.004537360 1854.804 -0.000402510 1856.792 -0.005099074 1858.780 0.001572133 1860.768 0.001937027 1862.756 -0.004756946 1864.744 -0.001675996 1866.732 0.000106955 1868.720 0.000152225 1870.708 -0.001143111 1872.696 -0.000460519 1874.684 -0.003076600 1876.672 -0.004371129 1878.660 -0.000070100 1880.648 -0.003507982 1882.636 0.009000352 1884.624 0.002654119 1886.612 0.000940809 1888.600 -0.002466550 1890.588 0.006631515 1892.576 0.008191666 1894.564 0.013797576 1896.552 0.009592571 1898.540 0.015569467 1900.528 0.022585686 1902.516 0.027011396 1904.504 0.037168853 1906.492 0.052334275 1908.480 0.065497503 1910.468 0.092310436 1912.456 0.109788150 1914.444 0.149835467 1916.432 0.190114155 1918.420 0.238005698 1920.408 0.291509151 1922.396 0.349899709 1924.384 0.409219235 1926.372 0.471946597 1928.360 0.536275744 1930.348 0.597074151 1932.336 0.665005088 1934.324 0.739980161 1936.312 0.818478227 1938.300 0.912339866 1940.288 1.008391857 1942.276 1.136072993 1944.264 1.287239552 1946.252 1.480282307 1948.240 1.698910117 1950.228 1.971799374 1952.216 2.317011833 1954.204 2.784301996 1956.192 3.351060629 1958.180 4.053459644 1960.168 4.972446442 1962.156 6.138072968 1964.144 7.629930973 1966.132 9.561995506 1968.120 11.991965294 1970.108 15.144146919 1972.096 18.889846802 1974.084 23.343593597 1976.072 28.378110886 1978.060 33.587856293 1980.048 38.742835999 1982.036 43.625045776 1984.024 48.082164764 1986.012 51.526580811 1988.000 54.418098450 1989.988 56.762050629 1991.976 58.773517609 1993.964 60.545085907 1995.952 62.221263885 1997.940 63.939292908 1999.928 65.567115784 2001.916 67.274703979 2003.904 69.006446838 2005.892 70.588584900 2007.880 72.166694641 2009.868 73.539978027 2011.856 74.765670776 2013.844 75.727455139 2015.832 76.461112976 2017.820 77.015121460 2019.808 77.269172668 2021.796 77.447052002 2023.784 77.490409851 2025.772 77.380226135 2027.760 77.277030945 2029.748 77.137443542 2031.736 77.081565857 2033.724 76.984039307 2035.712 76.982055664 2037.700 77.072853088 2039.688 77.211631775 2041.676 77.412918091 2043.664 77.702690125 2045.652 77.996482849 2047.640 78.340133667 2049.628 78.667610168 2051.616 79.020843506 2053.604 79.392448425 2055.592 79.673645020 2057.580 79.970489502 2059.568 80.185897827 2061.556 80.339904785 2063.544 80.513923645 2065.532 80.553749084 2067.520 80.588302612 2069.508 80.633483887 2071.496 80.588500977 2073.484 80.557563782 2075.472 80.503768921 2077.460 80.472747803 2079.448 80.413291931 2081.436 80.399795532 2083.424 80.429458618 2085.412 80.421875000 2087.400 80.504058838 2089.388 80.583625793 2091.376 80.678184509 2093.364 80.843429565 2095.352 80.990859985 2097.340 81.171379089 2099.328 81.377342224 2101.316 81.536605835 2103.304 81.746299744 2105.292 81.924018860 2107.280 82.086822510 2109.268 82.225669861 2111.256 82.353652954 2113.244 82.465270996 2115.232 82.513839722 2117.220 82.584114075 2119.208 82.613937378 2121.196 82.576690674 2123.184 82.567031860 2125.172 82.504837036 2127.160 82.409255981 2129.148 82.336608887 2131.136 82.245506287 2133.124 82.165977478 2135.112 82.035682678 2137.100 81.944427490 2139.088 81.833129883 2141.076 81.757614136 2143.064 81.683082581 2145.052 81.621307373 2147.040 81.578842163 2149.028 81.561714172 2151.016 81.557075500 2153.004 81.604537964 2154.992 81.614761353 2156.980 81.691947937 2158.968 81.759819031 2160.956 81.823043823 2162.944 81.975158691 2164.932 82.089408875 2166.920 82.249176025 2168.908 82.329734802 2170.896 82.511016846 2172.884 82.664009094 2174.872 82.786949158 2176.860 82.922378540 2178.848 83.014305115 2180.836 83.148452759 2182.824 83.208015442 2184.812 83.279083252 2186.800 83.386619568 2188.788 83.421081543 2190.776 83.464080811 2192.764 83.554748535 2194.752 83.578285217 2196.740 83.697021484 2198.728 83.694686890 2200.716 83.814773560 2202.704 83.869659424 2204.692 83.920288086 2206.680 83.996910095 2208.668 84.058944702 2210.656 84.115020752 2212.644 84.154853821 2214.632 84.163764954 2216.620 84.244522095 2218.608 84.263626099 2220.596 84.322311401 2222.584 84.375885010 2224.572 84.386924744 2226.560 84.482269287 2228.548 84.472946167 2230.536 84.559753418 2232.524 84.615379333 2234.512 84.659400940 2236.500 84.713768005 2238.488 84.791473389 2240.476 84.818649292 2242.464 84.855194092 2244.452 84.898719788 2246.440 84.937660217 2248.428 84.961700439 2250.416 84.963554382 2252.404 84.999176025 2254.392 84.978141785 2256.380 84.962348938 2258.368 84.921997070 2260.356 84.906852722 2262.344 84.882156372 2264.332 84.789947510 2266.320 84.723930359 2268.308 84.608581543 2270.296 84.445625305 2272.284 84.264183044 2274.272 84.022163391 2276.260 83.650161743 2278.248 83.216011047 2280.236 82.489067078 2282.224 81.684806824 2284.212 80.527648926 2286.200 79.097053528 2288.188 77.261367798 2290.176 75.020141602 2292.164 72.350898743 2294.152 69.257728577 2296.140 65.511215210 2298.128 61.385959625 2300.116 57.089908600 2302.104 52.610755920 2304.092 47.992862701 2306.080 43.470935822 2308.068 38.964939117 2310.056 34.659976959 2312.044 30.581796646 2314.032 26.937812805 2316.020 23.647399902 2318.008 20.635740280 2319.996 18.052289963 2321.984 15.775635719 2323.972 13.826401711 2325.960 12.127214432 2327.948 10.589762688 2329.936 9.282752037 2331.924 8.127222061 2333.912 7.114124298 2335.900 6.271456718 2337.888 5.496649265 2339.876 4.832757473 2341.864 4.291684151 2343.852 3.812221766 2345.840 3.378903389 2347.828 3.008507490 2349.816 2.681573868 2351.804 2.402582645 2353.792 2.163452387 2355.780 1.939674497 2357.768 1.748070478 2359.756 1.578176260 2361.744 1.420226812 2363.732 1.292954683 2365.720 1.173684239 2367.708 1.063418031 2369.696 0.965430021 2371.684 0.878204048 2373.672 0.800923645 2375.660 0.730493546 2377.648 0.673979640 2379.636 0.611267030 2381.624 0.558459461 2383.612 0.515979648 2385.600 0.471436054 2387.588 0.427414060 2389.576 0.394141853 2391.564 0.373394519 2393.552 0.337213337 2395.540 0.310035765 2397.528 0.286832303 2399.516 0.253182113 2401.504 0.238229781 2403.492 0.222090498 2405.480 0.204329163 2407.468 0.182342440 2409.456 0.173011243 2411.444 0.159524411 2413.432 0.140618801 2415.420 0.128041357 2417.408 0.136504129 2419.396 0.114089981 2421.384 0.109097935 2423.372 0.095149174 2425.360 0.086950853 2427.348 0.082164511 2429.336 0.074866109 2431.324 0.068448804 2433.312 0.063466363 2435.300 0.060195230 2437.288 0.054306079 2439.276 0.052897237 2441.264 0.047222532 2443.252 0.039803930 2445.240 0.032804646 2447.228 0.037447859 2449.216 0.032399151 2451.204 0.029561648 2453.192 0.028366832 2455.180 0.026848504 2457.168 0.029645145 2459.156 0.018841112 2461.144 0.016313737 2463.132 0.010697888 2465.120 0.030160766 2467.108 0.024290659 2469.096 0.013840666 2471.084 0.012434248 2473.072 0.012442374 2475.060 0.008754848 2477.048 0.008688907 2479.036 0.013756943 2481.024 0.011640197 2483.012 0.007220156 2485.000 0.005169122 2486.988 0.010203329 2488.976 0.003697358 2490.964 0.009660774 2492.952 0.010928935 2494.940 -0.001858562 2496.928 0.005429620 2498.916 0.001943722 2500.904 0.001361787 2502.892 0.006362989 2504.880 0.004894074 2506.868 0.002836467 2508.856 0.004083562 2510.844 0.004005792 2512.832 -0.003112683 2514.820 0.003495848 2516.808 0.005318317 2518.796 0.002032471 2520.784 0.002758460 2522.772 -0.000533145 2524.760 -0.000790089 2526.748 0.000220584 2528.736 0.002918082 2530.724 -0.000735576 2532.712 0.005134155 2534.700 -0.001956169 2536.688 0.002853678 2538.676 -0.001720066 2540.664 -0.001510115 2542.652 -0.000344353 2544.640 -0.004297487 2546.628 0.000210175 2548.616 -0.003602250 2550.604 -0.003781574 2552.592 -0.003886721 2554.580 0.000612462 2556.568 -0.004953460 2558.556 -0.003510534 2560.544 0.003618383 2562.532 -0.004120778 2564.520 -0.000741347 2566.508 -0.002981329 2568.496 -0.002082503 2570.484 0.003072015 2572.472 -0.001383567 2574.460 -0.002671971 2576.448 -0.002382637 2578.436 -0.002564559 2580.424 0.002572176 2582.412 -0.008029384 2584.400 -0.000701611 2586.388 -0.000955775 2588.376 0.002521888 2590.364 -0.005802983 2592.352 -0.004398557 2594.340 -0.008413793 2596.328 0.006069951 2598.316 -0.001501003 2600.304 -0.006073066 2602.292 -0.005214763 2604.280 -0.003335184 2606.268 -0.005496282 2608.256 -0.003782624 2610.244 -0.004472254 2612.232 0.002760089 2614.220 0.002175606 2616.208 -0.010011726 2618.196 -0.002496914 2620.184 -0.001465450 2622.172 -0.003094123 2624.160 -0.002039485 2626.148 -0.006481796 2628.136 0.003019189 2630.124 -0.001591812 2632.112 -0.005230745 2634.100 -0.004563307 2636.088 -0.003486391 2638.076 0.000861836 2640.064 -0.002308318 2642.052 -0.001294204 2644.040 -0.002726741 2646.028 -0.002622674 2648.016 0.000617211 2650.004 -0.007297798 2651.992 -0.002549525 2653.980 -0.005984362 2655.968 -0.001336213 2657.956 -0.006565399 2659.944 -0.001830731 2661.932 -0.006338181 2663.920 -0.000713346 2665.908 -0.003099863 2667.896 -0.000872962 2669.884 0.002855874 2671.872 -0.004069544 2673.860 -0.001837547 2675.848 -0.003576234 2677.836 -0.003333094 2679.824 -0.001564973 2681.812 -0.002405332 2683.800 -0.007466105 2685.788 -0.004304692 2687.776 -0.001942748 2689.764 -0.002099834 2691.752 -0.003418550 2693.740 -0.002896948 2695.728 -0.001395740 2697.716 -0.005612298 2699.704 -0.000573701 2701.692 -0.000698742 2703.680 -0.008371063 2705.668 -0.005369520 2707.656 -0.000024000 2709.644 -0.008786462 2711.632 -0.006095710 2713.620 -0.003457877 2715.608 -0.003784266 2717.596 -0.005046624 2719.584 -0.002730584 2721.572 -0.000424589 2723.560 -0.007994308 2725.548 -0.005937827 2727.536 -0.001862827 2729.524 -0.002287102 2731.512 -0.007696402 2733.500 0.009585961 2735.488 -0.005887644 2737.476 -0.006198636 2739.464 0.000244542 2741.452 -0.004568977 2743.440 -0.002147743 2745.428 -0.008354331 2747.416 -0.001250952 2749.404 -0.007001255 2751.392 0.001829779 2753.380 -0.003090169 2755.368 -0.003071668 2757.356 -0.006055873 2759.344 -0.003801299 2761.332 -0.003361101 2763.320 -0.004284318 2765.308 -0.002967855 2767.296 -0.006159457 2769.284 -0.003742089 2771.272 0.000077100 2773.260 -0.004251301 2775.248 -0.001544970 2777.236 -0.006667891 2779.224 -0.007800439 2781.212 -0.001650765 2783.200 0.002148306 2785.188 -0.008595048 2787.176 0.003822749 2789.164 -0.006876173 2791.152 -0.003088197 2793.140 -0.003267418 2795.128 -0.001783119 2797.116 -0.011004505 2799.104 0.009295812 2801.092 -0.002998927 2803.080 -0.006400269 2805.068 -0.004383996 2807.056 -0.002435135 2809.044 -0.005546552 2811.032 -0.002032424 2813.020 -0.006911632 2815.008 -0.005012406 2816.996 -0.003216654 2818.984 -0.005911262 2820.972 -0.001450432 2822.960 -0.006374983 2824.948 -0.007151951 2826.936 0.000589990 2828.924 -0.000148862 2830.912 -0.004121754 2832.900 -0.005227654 2834.888 -0.002580749 2836.876 -0.002261254 2838.864 -0.007354591 2840.852 0.002906168 2842.840 -0.005174249 2844.828 -0.008139496 2846.816 -0.003283578 2848.804 -0.003645203 2850.792 -0.006493034 2852.780 -0.006278065 2854.768 -0.002036463 2856.756 -0.002441723 2858.744 -0.002311371 2860.732 -0.002229932 2862.720 -0.004621052 2864.708 -0.004419663 2866.696 -0.002875306 2868.684 -0.005045285 2870.672 0.000199888 2872.660 -0.005925661 2874.648 -0.002675265 2876.636 -0.007310145 2878.624 -0.002851366 2880.612 -0.003694735 2882.600 -0.005366800 2884.588 -0.002110286 2886.576 -0.000385458 2888.564 -0.004830064 2890.552 -0.002853179 2892.540 0.000621188 2894.528 -0.001652972 2896.516 -0.006061236 2898.504 -0.002044740 2900.492 -0.008217859 2902.480 -0.003061873 2904.468 -0.011386733 2906.456 -0.005243275 2908.444 0.002138271 2910.432 -0.002276917 2912.420 -0.009960486 2914.408 -0.009078375 2916.396 0.004813456 2918.384 -0.003966467 2920.372 0.001025105 2922.360 -0.007720293 2924.348 -0.002191692 2926.336 -0.000203047 2928.324 -0.006541110 2930.312 -0.003034623 2932.300 -0.006221222 2934.288 -0.003152666 2936.276 -0.002575191 2938.264 -0.005349382 2940.252 -0.003247843 2942.240 -0.004959620 2944.228 0.003321868 2946.216 -0.004868456 2948.204 -0.013785455 2950.192 -0.008678491 2952.180 -0.007862760 2954.168 -0.004202695 2956.156 -0.012377191 2958.144 -0.009242234 2960.132 -0.003703241 2962.120 -0.000393006 2964.108 -0.015950028 2966.096 -0.003715838 2968.084 -0.008444398 2970.072 -0.011135261 2972.060 0.004582253 2974.048 -0.004287727 2976.036 -0.006115202 2978.024 -0.008966058 2980.012 -0.003500895 2982.000 -0.002426745