#lRMS=0.0004083506647 iRMS=0.0004083506938 0 # lk ukf_o5v uks_o5v fh fse fl # 1150.0 12.354247 10.980931 12.354247 0.000000 0.000000 1155.0 9.928268 8.291242 9.928268 0.000000 0.000000 1160.0 8.410753 7.608442 8.410753 0.000000 0.000000 1165.0 7.509275 6.992280 7.509275 0.000000 0.000000 1170.0 6.670680 4.924852 6.670680 0.000000 0.000000 1175.0 6.781011 5.311603 6.781011 0.000000 0.000000 1180.0 7.357984 6.347106 7.357984 0.000000 0.000000 1185.0 6.852360 6.348125 6.852360 0.000000 0.000000 1190.0 4.872262 5.994653 4.872262 0.000000 0.000000 1195.0 3.911742 2.993020 3.911742 0.000000 0.000000 1200.0 3.635705 3.000951 3.635705 0.000000 0.000000 1205.0 3.118013 2.088474 3.118013 0.000000 0.000000 1210.0 3.574178 4.643471 3.574178 0.000000 0.000000 1215.0 4.025427 4.739435 4.025427 0.000000 0.000000 1220.0 2.568774 1.811924 2.568774 0.000000 0.000000 1225.0 1.621761 1.097628 1.621761 0.000000 0.000000 1230.0 1.946986 2.095428 1.946986 0.000000 0.000000 1235.0 3.440087 2.499049 3.440087 0.000000 0.000000 1240.0 7.304927 4.461062 7.304927 0.000000 0.000000 1245.0 10.425267 7.279398 10.425267 0.000000 0.000000 1250.0 9.332570 6.200742 9.332570 0.000000 0.000000 1255.0 8.277149 5.760581 8.277149 0.000000 0.000000 1260.0 8.269590 5.407857 8.269590 0.000000 0.000000 1265.0 8.999817 5.904920 8.999817 0.000000 0.000000 1270.0 9.816989 6.777295 9.816989 0.000000 0.000000 1275.0 10.038819 7.267655 10.038819 0.000000 0.000000 1280.0 10.157413 6.672056 10.157413 0.000000 0.000000 1285.0 10.720798 7.105211 10.720798 0.000000 0.000000 1290.0 11.270990 7.436379 11.270990 0.000000 0.000000 1295.0 11.288293 7.468132 11.288293 0.000000 0.000000 1300.0 10.213554 6.677330 10.213554 0.000000 0.000000 1305.0 9.725484 5.377144 9.725484 0.000000 0.000000 1310.0 10.801042 6.940595 10.801042 0.000000 0.000000 1315.0 11.241415 7.144486 11.241415 0.000000 0.000000 1320.0 11.143845 6.909888 11.143845 0.000000 0.000000 1325.0 11.355783 6.556329 11.355783 0.000000 0.000000 1330.0 10.812620 6.313520 10.812620 0.000000 0.000000 1335.0 9.796715 5.013232 9.796715 0.000000 0.000000 1340.0 10.036439 5.253002 10.036439 0.000000 0.000000 1345.0 11.388572 6.423124 11.388572 0.000000 0.000000 1350.0 11.942840 6.679553 11.942840 0.000000 0.000000 1355.0 11.697521 6.662138 11.697521 0.000000 0.000000 1360.0 10.939327 6.527024 10.939327 0.000000 0.000000 1365.0 10.472205 6.093715 10.472205 0.000000 0.000000 1370.0 10.386893 6.801046 10.386893 0.000000 0.000000 1375.0 10.265371 5.308548 10.265371 0.000000 0.000000 1380.0 10.594095 5.727740 10.594095 0.000000 0.000000 1385.0 9.101425 4.452341 9.101425 0.000000 0.000000 1390.0 9.106222 4.521545 9.106222 0.000000 0.000000 1395.0 10.218836 4.540083 10.218836 0.000000 0.000000 1400.0 12.030488 5.714878 12.030488 0.000000 0.000000 1405.0 12.692549 6.907038 12.692549 0.000000 0.000000 1410.0 12.465882 5.662028 12.465882 0.000000 0.000000 1415.0 12.188085 6.108338 12.188085 0.000000 0.000000 1420.0 11.972627 5.192355 11.972627 0.000000 0.000000 1425.0 12.549244 5.694500 12.549244 0.000000 0.000000 1430.0 12.381000 4.780162 12.381000 0.000000 0.000000 1435.0 13.183895 5.854579 13.183895 0.000000 0.000000 1440.0 12.588732 5.512104 12.588732 0.000000 0.000000 1445.0 12.072426 5.389409 12.072426 0.000000 0.000000 1450.0 11.745475 5.174939 11.745475 0.000000 0.000000 1455.0 11.344063 4.798389 11.344063 0.000000 0.000000 1460.0 11.558090 4.909589 11.558090 0.000000 0.000000 1465.0 12.287302 4.808154 12.287302 0.000000 0.000000 1470.0 13.342228 5.305589 13.342228 0.000000 0.000000 1475.0 13.789039 5.131207 13.789039 0.000000 0.000000 1480.0 14.373831 5.464374 14.373831 0.000000 0.000000 1485.0 14.915152 5.388556 14.915152 0.000000 0.000000 1490.0 15.405516 5.847723 15.405516 0.000000 0.000000 1495.0 14.876936 5.619649 14.876936 0.000000 0.000000 1500.0 13.815476 5.113196 13.815476 0.000000 0.000000 1505.0 14.264360 4.961569 14.264360 0.000000 0.000000 1510.0 14.894167 5.760510 14.894167 0.000000 0.000000 1515.0 14.642174 5.567638 14.642174 0.000000 0.000000 1520.0 14.612108 5.320275 14.612108 0.000000 0.000000 1525.0 13.738270 4.798807 13.738270 0.000000 0.000000 1530.0 10.425825 4.512047 10.425825 0.000000 0.000000 1535.0 5.192809 3.709957 5.192809 0.000000 0.000000 1540.0 4.034249 1.328628 4.034249 0.000000 0.000000 1545.0 8.733002 3.033457 8.733002 0.000000 0.000000 1550.0 16.761051 4.487554 16.761051 0.000000 0.000000 1555.0 20.603991 6.974559 20.603991 0.000000 0.000000 1560.0 17.648708 5.817967 17.648708 0.000000 0.000000 1565.0 14.894928 4.394453 14.894928 0.000000 0.000000 1570.0 14.415968 4.187100 14.415968 0.000000 0.000000 1575.0 14.725375 4.407162 14.725375 0.000000 0.000000 1580.0 14.549064 4.213482 14.549064 0.000000 0.000000 1585.0 14.076339 4.260939 14.076339 0.000000 0.000000 1590.0 13.778352 4.303608 13.778352 0.000000 0.000000 1595.0 13.536096 4.184775 13.536096 0.000000 0.000000 1600.0 13.048507 3.880507 13.048507 0.000000 0.000000 1605.0 12.583019 3.788502 12.583019 0.000000 0.000000 1610.0 12.014565 3.365780 12.014565 0.000000 0.000000 1615.0 12.153325 3.364941 12.153325 0.000000 0.000000 1620.0 12.099739 3.379442 12.099739 0.000000 0.000000 1625.0 12.197218 3.330233 12.197218 0.000000 0.000000 1630.0 12.312810 3.253565 12.312810 0.000000 0.000000 1635.0 12.549278 3.621519 12.549278 0.000000 0.000000 1640.0 12.834955 3.654448 12.834955 0.000000 0.000000 1645.0 13.522785 3.611804 13.522785 0.000000 0.000000 1650.0 13.270918 4.037282 13.270918 0.000000 0.000000 1655.0 12.011052 3.588437 12.011052 0.000000 0.000000 1660.0 11.829187 3.118863 11.829187 0.000000 0.000000 1665.0 12.650260 3.602691 12.650260 0.000000 0.000000 1670.0 12.388281 3.164885 12.388281 0.000000 0.000000 1675.0 12.455683 3.190500 12.455683 0.000000 0.000000 1680.0 13.185306 3.875166 13.185306 0.000000 0.000000 1685.0 13.291745 4.163063 13.291745 0.000000 0.000000 1690.0 13.062643 3.497468 13.062643 0.000000 0.000000 1695.0 12.934876 3.605821 12.934876 0.000000 0.000000 1700.0 12.634619 3.346132 12.634619 0.000000 0.000000 1705.0 12.162938 3.692179 12.162938 0.000000 0.000000 1710.0 10.960016 3.546886 10.960016 0.000000 0.000000 1715.0 10.233763 3.452264 10.233763 0.000000 0.000000 1720.0 11.535001 2.931038 11.535001 0.000000 0.000000 1725.0 12.728098 2.968908 12.728098 0.000000 0.000000 1730.0 12.800633 3.104153 12.800633 0.000000 0.000000 1735.0 12.909595 3.354982 12.909595 0.000000 0.000000 1740.0 12.770240 3.414867 12.770240 0.000000 0.000000 1745.0 12.601005 3.365599 12.601005 0.000000 0.000000 1750.0 12.427034 3.382661 12.427034 0.000000 0.000000 1755.0 12.513680 3.346527 12.513680 0.000000 0.000000 1760.0 12.520302 3.349519 12.520302 0.000000 0.000000 1765.0 12.271631 3.346327 12.271631 0.000000 0.000000 1770.0 12.151934 3.374699 12.151934 0.000000 0.000000 1775.0 12.350992 3.423854 12.350992 0.000000 0.000000 1780.0 12.207653 3.344751 12.207653 0.000000 0.000000 1785.0 11.225578 3.760432 11.225578 0.000000 0.000000 1790.0 9.867487 4.012749 9.867487 0.000000 0.000000 1795.0 10.754947 2.866405 10.754947 0.000000 0.000000 1800.0 11.228872 3.260080 11.228872 0.000000 0.000000 1805.0 10.871095 3.157174 10.871095 0.000000 0.000000 1810.0 10.663568 2.947707 10.663568 0.000000 0.000000 1815.0 10.987250 3.218279 10.987250 0.000000 0.000000 1820.0 11.055533 3.176932 11.055533 0.000000 0.000000 1825.0 10.850305 3.097930 10.850305 0.000000 0.000000 1830.0 10.662852 3.164541 10.662852 0.000000 0.000000 1835.0 10.525848 3.372072 10.525848 0.000000 0.000000 1840.0 10.271605 3.141080 10.271605 0.000000 0.000000 1845.0 10.132284 3.053606 10.132284 0.000000 0.000000 1850.0 9.780405 2.947453 9.780405 0.000000 0.000000 1855.0 9.363360 2.708431 9.363360 0.000000 0.000000 1860.0 9.375544 2.803971 9.375544 0.000000 0.000000 1865.0 9.483219 2.761803 9.483219 0.000000 0.000000 1870.0 9.344897 2.938748 9.344897 0.000000 0.000000 1875.0 9.076859 2.833525 9.076859 0.000000 0.000000 1880.0 9.020525 2.876675 9.020525 0.000000 0.000000 1885.0 8.783040 2.786741 8.783040 0.000000 0.000000 1890.0 8.647580 2.694352 8.647580 0.000000 0.000000 1895.0 8.541557 2.803611 8.541557 0.000000 0.000000 1900.0 8.310987 2.953053 8.310987 0.000000 0.000000 1905.0 8.013688 2.826595 8.013688 0.000000 0.000000 1910.0 7.913830 2.718022 7.913830 0.000000 0.000000 1915.0 7.650915 2.619924 7.650915 0.000000 0.000000 1920.0 7.274323 2.479655 7.274323 0.000000 0.000000 1925.0 7.102759 2.305085 7.102759 0.000000 0.000000 1930.0 7.157187 2.424468 7.157187 0.000000 0.000000 1935.0 7.082033 2.545681 7.082033 0.000000 0.000000 1940.0 6.943686 2.591086 6.943686 0.000000 0.000000 1945.0 6.773274 2.520771 6.773274 0.000000 0.000000 1950.0 6.621999 2.474335 6.621999 0.000000 0.000000 1955.0 6.383287 2.696472 6.383287 0.000000 0.000000 1960.0 6.088006 2.597074 6.088006 0.000000 0.000000 1965.0 5.908768 3.036317 5.908768 0.000000 0.000000 1970.0 5.727754 2.426451 5.727754 0.000000 0.000000 1975.0 5.799105 2.515983 5.799105 0.000000 0.000000 1980.0 5.645377 2.502501 5.645377 0.000000 0.000000 1985.0 5.521245 2.596977 5.521245 0.000000 0.000000 1990.0 5.106112 2.761676 5.106112 0.000000 0.000000 1995.0 4.826860 2.500480 4.826860 0.000000 0.000000 2000.0 5.111944 2.426430 5.111944 0.000000 0.000000 2005.0 4.885216 2.840626 4.885216 0.000000 0.000000 2010.0 4.573777 2.117482 4.573777 0.000000 0.000000 2015.0 4.584790 2.294907 4.584790 0.000000 0.000000 2020.0 4.503578 2.410586 4.503578 0.000000 0.000000 2025.0 4.240175 2.455351 4.240175 0.000000 0.000000 2030.0 4.129937 2.196985 4.129937 0.000000 0.000000 2035.0 4.207735 2.134442 4.207735 0.000000 0.000000 2040.0 4.035404 2.565257 4.035404 0.000000 0.000000 2045.0 3.889281 2.107994 3.889281 0.000000 0.000000 2050.0 3.855501 2.405015 3.855501 0.000000 0.000000 2055.0 3.911336 2.102076 3.911336 0.000000 0.000000 2060.0 3.437137 1.595227 3.437137 0.000000 0.000000 2065.0 3.304794 1.947687 3.304794 0.000000 0.000000 2070.0 3.763025 1.807453 3.763025 0.000000 0.000000 2075.0 3.530975 1.819214 3.530975 0.000000 0.000000 2080.0 3.654477 1.854660 3.654477 0.000000 0.000000 2085.0 3.468575 1.888538 3.468575 0.000000 0.000000 2090.0 3.215738 1.972531 3.215738 0.000000 0.000000 2095.0 2.952195 1.820588 2.952195 0.000000 0.000000 2100.0 2.596302 1.940090 2.596302 0.000000 0.000000 2105.0 2.644565 1.622685 2.644565 0.000000 0.000000 2110.0 2.885005 1.441361 2.885005 0.000000 0.000000 2115.0 2.844980 1.908998 2.844980 0.000000 0.000000 2120.0 2.621891 1.833098 2.621891 0.000000 0.000000 2125.0 2.728950 1.482013 2.728950 0.000000 0.000000 2130.0 2.785945 1.860000 2.785945 0.000000 0.000000 2135.0 2.407447 1.641312 2.407447 0.000000 0.000000 2140.0 2.330971 1.603457 2.330971 0.000000 0.000000 2145.0 2.281234 1.623693 2.281234 0.000000 0.000000 2150.0 2.207196 1.479048 2.207196 0.000000 0.000000 2155.0 2.292736 1.598029 2.292736 0.000000 0.000000 2160.0 2.328056 1.593810 2.328056 0.000000 0.000000 2165.0 2.232810 1.350886 2.232810 0.000000 0.000000 2170.0 2.143929 1.212597 2.143929 0.000000 0.000000 2175.0 1.943004 1.508192 1.943004 0.000000 0.000000 2180.0 1.752884 1.494123 1.752884 0.000000 0.000000 2185.0 1.754634 1.396778 1.754634 0.000000 0.000000 2190.0 1.819848 1.380808 1.819848 0.000000 0.000000 2195.0 1.998276 1.535704 1.998276 0.000000 0.000000 2200.0 2.062936 1.475799 2.062936 0.000000 0.000000 2205.0 2.103238 1.413158 2.103238 0.000000 0.000000 2210.0 1.984544 1.384953 1.984544 0.000000 0.000000 2215.0 2.018105 1.501866 2.018105 0.000000 0.000000 2220.0 2.051461 1.457442 2.051461 0.000000 0.000000 2225.0 2.148038 1.287029 2.148038 0.000000 0.000000 2230.0 2.267962 1.206956 2.267962 0.000000 0.000000 2235.0 2.180169 1.207939 2.180169 0.000000 0.000000 2240.0 2.178752 1.373532 2.178752 0.000000 0.000000 2245.0 2.228225 1.305947 2.228225 0.000000 0.000000 2250.0 2.501392 1.323714 2.501392 0.000000 0.000000 2255.0 2.737138 1.253049 2.737138 0.000000 0.000000 2260.0 2.591789 1.484730 2.591789 0.000000 0.000000 2265.0 2.460554 1.237041 2.460554 0.000000 0.000000 2270.0 2.715842 1.070648 2.715842 0.000000 0.000000 2275.0 2.609978 1.426401 2.609978 0.000000 0.000000 2280.0 2.570449 1.631198 2.570449 0.000000 0.000000 2285.0 2.633254 1.521573 2.633254 0.000000 0.000000 2290.0 2.757573 1.508803 2.757573 0.000000 0.000000 2295.0 2.891746 1.460144 2.891746 0.000000 0.000000 2300.0 2.875659 1.339004 2.875659 0.000000 0.000000 2305.0 3.043302 1.247215 3.043302 0.000000 0.000000 2310.0 3.359229 1.220869 3.359229 0.000000 0.000000 2315.0 3.425841 1.409931 3.425841 0.000000 0.000000 2320.0 3.165980 1.579322 3.165980 0.000000 0.000000 2325.0 3.341468 1.416315 3.341468 0.000000 0.000000 2330.0 3.675023 1.215222 3.675023 0.000000 0.000000 2335.0 3.857401 1.514333 3.857401 0.000000 0.000000 2340.0 3.769199 1.557044 3.769199 0.000000 0.000000 2345.0 3.779188 1.363810 3.779188 0.000000 0.000000 2350.0 3.907269 1.339942 3.907269 0.000000 0.000000 2355.0 3.917960 1.563402 3.917960 0.000000 0.000000 2360.0 3.969418 1.604337 3.969418 0.000000 0.000000 2365.0 3.918830 1.838475 3.918830 0.000000 0.000000 2370.0 4.108988 1.703990 4.108988 0.000000 0.000000 2375.0 4.199293 1.582343 4.199293 0.000000 0.000000 2380.0 4.316381 1.464765 4.316381 0.000000 0.000000 2385.0 4.350537 1.467788 4.350537 0.000000 0.000000 2390.0 4.208629 1.439262 4.208629 0.000000 0.000000 2395.0 4.364014 1.606333 4.364014 0.000000 0.000000 2400.0 4.731734 1.377996 4.731734 0.000000 0.000000 2405.0 4.630998 1.547747 4.630998 0.000000 0.000000 2410.0 4.582914 1.675227 4.582914 0.000000 0.000000 2415.0 4.617506 1.706107 4.617506 0.000000 0.000000 2420.0 4.691247 1.674449 4.691247 0.000000 0.000000 2425.0 4.889919 1.356373 4.889919 0.000000 0.000000 2430.0 5.154402 1.445111 5.154402 0.000000 0.000000 2435.0 5.108383 1.567734 5.108383 0.000000 0.000000 2440.0 5.118075 1.421666 5.118075 0.000000 0.000000 2445.0 5.349842 1.394326 5.349842 0.000000 0.000000 2450.0 5.312993 1.398342 5.312993 0.000000 0.000000 2455.0 5.657761 1.544676 5.657761 0.000000 0.000000 2460.0 5.981045 1.577152 5.981045 0.000000 0.000000 2465.0 6.014513 1.701465 6.014513 0.000000 0.000000 2470.0 5.659464 1.643323 5.659464 0.000000 0.000000 2475.0 5.557835 1.548991 5.557835 0.000000 0.000000 2480.0 5.564890 1.353970 5.564890 0.000000 0.000000 2485.0 5.657494 1.414175 5.657494 0.000000 0.000000 2490.0 5.721494 1.447686 5.721494 0.000000 0.000000 2495.0 5.530495 1.506557 5.530495 0.000000 0.000000 2500.0 5.810987 1.485966 5.810987 0.000000 0.000000 2505.0 5.816087 1.339867 5.816087 0.000000 0.000000 2510.0 5.755470 1.447402 5.755470 0.000000 0.000000 2515.0 5.725237 1.309335 5.725237 0.000000 0.000000 2520.0 5.730535 1.328669 5.730535 0.000000 0.000000 2525.0 5.885444 1.306288 5.885444 0.000000 0.000000 2530.0 6.190369 1.677437 6.190369 0.000000 0.000000 2535.0 6.351297 1.653854 6.351297 0.000000 0.000000 2540.0 6.236351 1.569306 6.236351 0.000000 0.000000 2545.0 6.178383 1.453513 6.178383 0.000000 0.000000 2550.0 6.375881 1.684425 6.375881 0.000000 0.000000 2555.0 6.290639 1.476426 6.290639 0.000000 0.000000 2560.0 6.221519 1.471200 6.221519 0.000000 0.000000 2565.0 6.471826 1.473326 6.471826 0.000000 0.000000 2570.0 6.569402 1.394067 6.569402 0.000000 0.000000 2575.0 6.467954 1.718736 6.467954 0.000000 0.000000 2580.0 5.467284 1.352420 5.467284 0.000000 0.000000 2585.0 4.983804 1.424178 4.983804 0.000000 0.000000 2590.0 5.579272 1.201935 5.579272 0.000000 0.000000 2595.0 6.049005 1.309604 6.049005 0.000000 0.000000 2600.0 6.081197 1.468689 6.081197 0.000000 0.000000 2605.0 6.241147 1.524844 6.241147 0.000000 0.000000 2610.0 6.327127 1.348299 6.327127 0.000000 0.000000 2615.0 6.680542 1.598418 6.680542 0.000000 0.000000 2620.0 6.848479 1.620808 6.848479 0.000000 0.000000 2625.0 6.886405 1.666129 6.886405 0.000000 0.000000 2630.0 6.879529 1.618595 6.879529 0.000000 0.000000 2635.0 6.857961 1.594763 6.857961 0.000000 0.000000 2640.0 6.556355 1.617549 6.556355 0.000000 0.000000 2645.0 6.612978 1.799645 6.612978 0.000000 0.000000 2650.0 6.819241 1.681674 6.819241 0.000000 0.000000 2655.0 6.868794 1.709042 6.868794 0.000000 0.000000 2660.0 6.779873 1.691933 6.779873 0.000000 0.000000 2665.0 6.673353 1.610826 6.673353 0.000000 0.000000 2670.0 6.740400 1.623416 6.740400 0.000000 0.000000 2675.0 6.773973 1.536867 6.773973 0.000000 0.000000 2680.0 6.790723 1.582767 6.790723 0.000000 0.000000 2685.0 6.845486 1.692389 6.845486 0.000000 0.000000 2690.0 7.015737 1.916854 7.015737 0.000000 0.000000 2695.0 6.780900 1.644191 6.780900 0.000000 0.000000 2700.0 6.700571 1.574557 6.700571 0.000000 0.000000 2705.0 6.811278 1.607553 6.811278 0.000000 0.000000 2710.0 6.840482 1.631284 6.840482 0.000000 0.000000 2715.0 6.746272 1.414754 6.746272 0.000000 0.000000 2720.0 6.753408 1.461946 6.753408 0.000000 0.000000 2725.0 6.769570 1.549111 6.769570 0.000000 0.000000 2730.0 6.967436 1.940314 6.967436 0.000000 0.000000 2735.0 7.008129 1.837735 7.008129 0.000000 0.000000 2740.0 6.983191 1.866293 6.983191 0.000000 0.000000 2745.0 6.897233 1.567269 6.897233 0.000000 0.000000 2750.0 7.035151 1.651565 7.035151 0.000000 0.000000 2755.0 6.950256 1.613284 6.950256 0.000000 0.000000 2760.0 7.161397 1.631245 7.161397 0.000000 0.000000 2765.0 7.359293 1.793003 7.359293 0.000000 0.000000 2770.0 7.204125 1.728424 7.204125 0.000000 0.000000 2775.0 7.005527 1.652848 7.005527 0.000000 0.000000 2780.0 7.017360 1.632840 7.017360 0.000000 0.000000 2785.0 6.922927 1.550284 6.922927 0.000000 0.000000 2790.0 6.840604 1.519763 6.840604 0.000000 0.000000 2795.0 6.521082 1.415462 6.521082 0.000000 0.000000 2800.0 6.245466 1.162196 6.245466 0.000000 0.000000 2805.0 6.520746 1.315059 6.520746 0.000000 0.000000 2810.0 7.093396 1.753186 7.093396 0.000000 0.000000 2815.0 7.254028 1.515318 7.254028 0.000000 0.000000 2820.0 7.235205 1.621412 7.235205 0.000000 0.000000 2825.0 7.030965 1.518881 7.030965 0.000000 0.000000 2830.0 6.983291 1.427516 6.983291 0.000000 0.000000 2835.0 7.143864 1.588251 7.143864 0.000000 0.000000 2840.0 7.283491 1.715723 7.283491 0.000000 0.000000 2845.0 7.132699 1.521876 7.132699 0.000000 0.000000 2850.0 7.049846 1.570510 7.049846 0.000000 0.000000 2855.0 6.917205 1.479173 6.917205 0.000000 0.000000 2860.0 7.058835 1.594951 7.058835 0.000000 0.000000 2865.0 7.241823 1.697535 7.241823 0.000000 0.000000 2870.0 7.220841 1.506400 7.220841 0.000000 0.000000 2875.0 7.226741 1.458091 7.226741 0.000000 0.000000 2880.0 7.167696 1.459477 7.167696 0.000000 0.000000 2885.0 7.236569 1.596384 7.236569 0.000000 0.000000 2890.0 7.366451 1.537076 7.366451 0.000000 0.000000 2895.0 7.398692 1.660972 7.398692 0.000000 0.000000 2900.0 7.330579 1.542405 7.330579 0.000000 0.000000 2905.0 7.186863 1.419750 7.186863 0.000000 0.000000 2910.0 7.270552 1.487518 7.270552 0.000000 0.000000 2915.0 7.346966 1.391115 7.346966 0.000000 0.000000 2920.0 7.412508 1.410635 7.412508 0.000000 0.000000 2925.0 7.393971 1.460993 7.393971 0.000000 0.000000 2930.0 7.342690 1.445406 7.342690 0.000000 0.000000 2935.0 7.227251 1.379503 7.227251 0.000000 0.000000 2940.0 7.237062 1.249994 7.237062 0.000000 0.000000 2945.0 7.355906 1.307511 7.355906 0.000000 0.000000 2950.0 7.310308 1.208132 7.310308 0.000000 0.000000 2955.0 7.440499 1.417200 7.440499 0.000000 0.000000 2960.0 7.511858 1.343464 7.511858 0.000000 0.000000 2965.0 7.360662 1.238376 7.360662 0.000000 0.000000 2970.0 7.375257 1.251678 7.375257 0.000000 0.000000 2975.0 7.403920 1.125240 7.403920 0.000000 0.000000 2980.0 7.498200 1.103195 7.498200 0.000000 0.000000 2985.0 7.362726 0.989399 7.362726 0.000000 0.000000 2990.0 7.356517 1.188063 7.356517 0.000000 0.000000 2995.0 7.233176 1.028475 7.233176 0.000000 0.000000 3000.0 7.216478 1.020066 7.216478 0.000000 0.000000 3005.0 7.201781 0.875095 7.201781 0.000000 0.000000 3010.0 7.376844 1.006738 7.376844 0.000000 0.000000 3015.0 7.414644 1.028219 7.414644 0.000000 0.000000 3020.0 7.274108 0.990214 7.274108 0.000000 0.000000 3025.0 7.047410 0.796423 7.047410 0.000000 0.000000 3030.0 7.111680 0.750333 7.111680 0.000000 0.000000 3035.0 7.205910 0.690327 7.205910 0.000000 0.000000 3040.0 7.335783 0.821312 7.335783 0.000000 0.000000 3045.0 7.237627 0.765641 7.237627 0.000000 0.000000 3050.0 7.180950 0.690108 7.180950 0.000000 0.000000 3055.0 7.271171 0.735286 7.271171 0.000000 0.000000 3060.0 7.012531 0.542726 7.012531 0.000000 0.000000 3065.0 6.912734 0.412530 6.912734 0.000000 0.000000 3070.0 7.079757 0.398164 7.079757 0.000000 0.000000 3075.0 7.049777 0.278084 7.049777 0.000000 0.000000 3080.0 7.367270 0.405594 7.367270 0.000000 0.000000 3085.0 7.669431 0.646472 7.669431 0.000000 0.000000 3090.0 7.642879 0.696330 7.642879 0.000000 0.000000 3095.0 7.518178 0.475324 7.518178 0.000000 0.000000 3100.0 7.707456 0.338800 7.707456 0.000000 0.000000 3105.0 7.807666 0.418296 7.807666 0.000000 0.000000 3110.0 7.708428 0.163947 7.708428 0.000000 0.000000 3115.0 7.709791 0.666416 7.709791 0.000000 0.000000 3120.0 7.734833 0.513608 7.734833 0.000000 0.000000 3125.0 7.950598 0.399707 7.950598 0.000000 0.000000 3130.0 7.960353 0.580373 7.960353 0.000000 0.000000 3135.0 7.871122 0.711457 7.871122 0.000000 0.000000 3140.0 7.914507 0.942511 7.914507 0.000000 0.000000 3145.0 8.231490 0.826147 8.231490 0.000000 0.000000 3150.0 8.361894 0.923019 8.361894 0.000000 0.000000 3155.0 8.316783 0.937988 8.316783 0.000000 0.000000 3160.0 8.103815 0.033117 8.103815 0.000000 0.000000 3165.0 8.254359 0.144155 8.254359 0.000000 0.000000 3170.0 8.392982 0.243241 8.392982 0.000000 0.000000 3175.0 8.489452 0.217535 8.489452 0.000000 0.000000 3180.0 8.378233 0.216678 8.378233 0.000000 0.000000 3185.0 8.139612 0.148200 8.139612 0.000000 0.000000 3190.0 8.220535 0.405197 8.220535 0.000000 0.000000 3195.0 7.948538 0.546360 7.948538 0.000000 0.000000 3200.0 7.355319 0.000000 7.355319 0.000000 0.000000 3205.0 7.697585 0.000000 7.697585 0.000000 0.000000 3210.0 7.992072 0.000000 7.992072 0.000000 0.000000 3215.0 7.793368 0.000000 7.793368 0.000000 0.000000 3220.0 7.500418 0.000000 7.500418 0.000000 0.000000 3225.0 7.558261 0.000000 7.558261 0.000000 0.000000 3230.0 7.751969 0.000000 7.751969 0.000000 0.000000 3235.0 7.780250 0.000000 7.780250 0.000000 0.000000 3240.0 7.656339 0.000000 7.656339 0.000000 0.000000 3245.0 7.484559 0.000000 7.484559 0.000000 0.000000 3250.0 7.419063 0.000000 7.419063 0.000000 0.000000 3255.0 7.546488 0.000000 7.546488 0.000000 0.000000 3260.0 7.633584 0.000000 7.633584 0.000000 0.000000 3265.0 7.468321 0.000000 7.468321 0.000000 0.000000 3270.0 7.243440 0.000000 7.243440 0.000000 0.000000 3275.0 7.172769 0.000000 7.172769 0.000000 0.000000 3280.0 7.149729 0.000000 7.149729 0.000000 0.000000 3285.0 7.038074 0.000000 7.038074 0.000000 0.000000 3290.0 6.903294 0.000000 6.903294 0.000000 0.000000 3295.0 6.826443 0.000000 6.826443 0.000000 0.000000 3300.0 6.749083 0.000000 6.749083 0.000000 0.000000 3305.0 6.615716 0.000000 6.615716 0.000000 0.000000 3310.0 6.522100 0.000000 6.522100 0.000000 0.000000 3315.0 6.559974 0.000000 6.559974 0.000000 0.000000 3320.0 6.653771 0.000000 6.653771 0.000000 0.000000 3325.0 6.698923 0.000000 6.698923 0.000000 0.000000 3330.0 6.642181 0.000000 6.642181 0.000000 0.000000 3335.0 6.482273 0.000000 6.482273 0.000000 0.000000 3340.0 6.374506 0.000000 6.374506 0.000000 0.000000 3345.0 6.440778 0.000000 6.440778 0.000000 0.000000 3350.0 6.512753 0.000000 6.512753 0.000000 0.000000 3355.0 6.422764 0.000000 6.422764 0.000000 0.000000 3360.0 6.296062 0.000000 6.296062 0.000000 0.000000 3365.0 6.273357 0.000000 6.273357 0.000000 0.000000 3370.0 6.264282 0.000000 6.264282 0.000000 0.000000 3375.0 6.166691 0.000000 6.166691 0.000000 0.000000 3380.0 6.062383 0.000000 6.062383 0.000000 0.000000 3385.0 6.042455 0.000000 6.042455 0.000000 0.000000 3390.0 6.051256 0.000000 6.051256 0.000000 0.000000 3395.0 6.017390 0.000000 6.017390 0.000000 0.000000 3400.0 5.953247 0.000000 5.953247 0.000000 0.000000 3405.0 5.891100 0.000000 5.891100 0.000000 0.000000 3410.0 5.858983 0.000000 5.858983 0.000000 0.000000 3415.0 5.872938 0.000000 5.872938 0.000000 0.000000 3420.0 5.905296 0.000000 5.905296 0.000000 0.000000 3425.0 5.922138 0.000000 5.922138 0.000000 0.000000 3430.0 5.908273 0.000000 5.908273 0.000000 0.000000 3435.0 5.863833 0.000000 5.863833 0.000000 0.000000 3440.0 5.831523 0.000000 5.831523 0.000000 0.000000 3445.0 5.845898 0.000000 5.845898 0.000000 0.000000 3450.0 5.866347 0.000000 5.866347 0.000000 0.000000 3455.0 5.846630 0.000000 5.846630 0.000000 0.000000 3460.0 5.793149 0.000000 5.793149 0.000000 0.000000 3465.0 5.720603 0.000000 5.720603 0.000000 0.000000 3470.0 5.624221 0.000000 5.624221 0.000000 0.000000 3475.0 5.507444 0.000000 5.507444 0.000000 0.000000 3480.0 5.426026 0.000000 5.426026 0.000000 0.000000 3485.0 5.429195 0.000000 5.429195 0.000000 0.000000 3490.0 5.487771 0.000000 5.487771 0.000000 0.000000 3495.0 5.550201 0.000000 5.550201 0.000000 0.000000 3500.0 5.553849 0.000000 5.553849 0.000000 0.000000 3505.0 5.465034 0.000000 5.465034 0.000000 0.000000 3510.0 5.506341 0.102702 5.506341 0.000000 0.000000 3515.0 5.528964 0.121904 5.528964 0.000000 0.000000 3520.0 5.525383 0.111943 5.525383 0.000000 0.000000 3525.0 5.492723 0.116668 5.492723 0.000000 0.000000 3530.0 5.432461 0.124975 5.432461 0.000000 0.000000 3535.0 5.408492 0.140901 5.408492 0.000000 0.000000 3540.0 5.383089 0.136063 5.383089 0.000000 0.000000 3545.0 5.350412 0.112411 5.350412 0.000000 0.000000 3550.0 5.315348 0.100662 5.315348 0.000000 0.000000 3555.0 5.268064 0.103338 5.268064 0.000000 0.000000 3560.0 5.215472 0.104474 5.215472 0.000000 0.000000 3565.0 5.181294 0.102190 5.181294 0.000000 0.000000 3570.0 5.151640 0.103315 5.151640 0.000000 0.000000 3575.0 5.064332 0.087931 5.064332 0.000000 0.000000 3580.0 5.000496 0.084121 5.000496 0.000000 0.000000 3585.0 4.956786 0.089517 4.956786 0.000000 0.000000 3590.0 4.938492 0.083652 4.938492 0.000000 0.000000 3595.0 4.931778 0.061376 4.931778 0.000000 0.000000 3600.0 4.914600 0.045544 4.914600 0.000000 0.000000 3605.0 4.898636 0.034939 4.898636 0.000000 0.000000 3610.0 4.937316 0.018139 4.937316 0.000000 0.000000 3615.0 4.910562 0.011027 4.910562 0.000000 0.000000 3620.0 4.873390 0.028471 4.873390 0.000000 0.000000 3625.0 4.879949 0.054438 4.879949 0.000000 0.000000 3630.0 4.896858 0.091727 4.896858 0.000000 0.000000 3635.0 4.908331 0.115631 4.908331 0.000000 0.000000 3640.0 4.906817 0.109281 4.906817 0.000000 0.000000 3645.0 4.897730 0.090167 4.897730 0.000000 0.000000 3650.0 4.896791 0.082446 4.896791 0.000000 0.000000 3655.0 4.954408 0.043151 4.954408 0.000000 0.000000 3660.0 4.963260 0.059221 4.963260 0.000000 0.000000 3665.0 4.921260 0.092722 4.921260 0.000000 0.000000 3670.0 4.859016 0.093885 4.859016 0.000000 0.000000 3675.0 4.789067 0.069552 4.789067 0.000000 0.000000 3680.0 4.730928 0.088458 4.730928 0.000000 0.000000 3685.0 4.730941 0.101229 4.730941 0.000000 0.000000 3690.0 4.705989 0.095559 4.705989 0.000000 0.000000 3695.0 4.676873 0.068080 4.676873 0.000000 0.000000 3700.0 4.639644 0.075502 4.639644 0.000000 0.000000 3705.0 4.590496 0.114990 4.590496 0.000000 0.000000 3710.0 4.602149 0.116104 4.602149 0.000000 0.000000 3715.0 4.638532 0.100211 4.638532 0.000000 0.000000 3720.0 4.603949 0.113214 4.603949 0.000000 0.000000 3725.0 4.533883 0.126596 4.533883 0.000000 0.000000 3730.0 4.507094 0.127459 4.507094 0.000000 0.000000 3735.0 4.544147 0.125802 4.544147 0.000000 0.000000 3740.0 4.599780 0.095496 4.599780 0.000000 0.000000 3745.0 4.536463 0.091610 4.536463 0.000000 0.000000 3750.0 4.390773 0.118854 4.390773 0.000000 0.000000 3755.0 4.322390 0.106217 4.322390 0.000000 0.000000 3760.0 4.326548 0.070336 4.326548 0.000000 0.000000 3765.0 4.309671 0.070472 4.309671 0.000000 0.000000 3770.0 4.257657 0.171323 4.257657 0.000000 0.000000 3775.0 4.445686 0.146931 4.445686 0.000000 0.000000 3780.0 4.638746 0.105677 4.638746 0.000000 0.000000 3785.0 4.617775 0.116616 4.617775 0.000000 0.000000 3790.0 4.486809 0.130097 4.486809 0.000000 0.000000 3795.0 4.310945 0.213776 4.310945 0.000000 0.000000 3800.0 4.340013 0.215906 4.340013 0.000000 0.000000 3805.0 4.535757 0.151863 4.535757 0.000000 0.000000 3810.0 4.635430 0.162569 4.635430 0.000000 0.000000 3815.0 4.648519 0.168461 4.648519 0.000000 0.000000 3820.0 4.598944 0.166073 4.598944 0.000000 0.000000 3825.0 4.505975 0.124363 4.505975 0.000000 0.000000 3830.0 4.280913 0.153595 4.280913 0.000000 0.000000 3835.0 4.118976 0.239347 4.118976 0.000000 0.000000 3840.0 4.288995 0.157102 4.288995 0.000000 0.000000 3845.0 4.447870 0.123449 4.447870 0.000000 0.000000 3850.0 4.471776 0.161192 4.471776 0.000000 0.000000 3855.0 4.429366 0.197455 4.429366 0.000000 0.000000 3860.0 4.410645 0.188049 4.410645 0.000000 0.000000 3865.0 4.371662 0.184406 4.371662 0.000000 0.000000 3870.0 4.344462 0.162452 4.344462 0.000000 0.000000 3875.0 4.299703 0.131764 4.299703 0.000000 0.000000 3880.0 4.121013 0.124947 4.121013 0.000000 0.000000 3885.0 3.834561 0.211486 3.834561 0.000000 0.000000 3890.0 3.808447 0.240232 3.808447 0.000000 0.000000 3895.0 4.071723 0.163191 4.071723 0.000000 0.000000 3900.0 4.249123 0.147635 4.249123 0.000000 0.000000 3905.0 4.270894 0.153820 4.270894 0.000000 0.000000 3910.0 4.220328 0.143250 4.220328 0.000000 0.000000 3915.0 4.143891 0.138253 4.143891 0.000000 0.000000 3920.0 4.077285 0.153106 4.077285 0.000000 0.000000 3925.0 4.038380 0.156029 4.038380 0.000000 0.000000 3930.0 3.976930 0.177657 3.976930 0.000000 0.000000 3935.0 3.979873 0.186914 3.979873 0.000000 0.000000 3940.0 4.065801 0.159168 4.065801 0.000000 0.000000 3945.0 4.082828 0.169694 4.082828 0.000000 0.000000 3950.0 4.060128 0.167595 4.060128 0.000000 0.000000 3955.0 3.982962 0.141871 3.982962 0.000000 0.000000 3960.0 3.787206 0.106290 3.787206 0.000000 0.000000 3965.0 3.475824 0.153082 3.475824 0.000000 0.000000 3970.0 3.350482 0.223033 3.350482 0.000000 0.000000 3975.0 3.614794 0.126568 3.614794 0.000000 0.000000 3980.0 3.806394 0.115239 3.806394 0.000000 0.000000 3985.0 3.834706 0.129081 3.834706 0.000000 0.000000 3990.0 3.793397 0.125911 3.793397 0.000000 0.000000 3995.0 3.764283 0.117487 3.764283 0.000000 0.000000 4000.0 3.740660 0.128089 3.740660 0.000000 0.000000 4005.0 3.715607 0.132467 3.715607 0.000000 0.000000 4010.0 3.685520 0.123459 3.685520 0.000000 0.000000 4015.0 3.641503 0.106290 3.641503 0.000000 0.000000 4020.0 3.555322 0.120898 3.555322 0.000000 0.000000 4025.0 3.470134 0.159302 3.470134 0.000000 0.000000 4030.0 3.488447 0.126285 3.488447 0.000000 0.000000 4035.0 3.526244 0.111815 3.526244 0.000000 0.000000 4040.0 3.567580 0.119484 3.567580 0.000000 0.000000 4045.0 3.588054 0.134756 3.588054 0.000000 0.000000 4050.0 3.595747 0.129657 3.595747 0.000000 0.000000 4055.0 3.563520 0.144596 3.563520 0.000000 0.000000 4060.0 3.546625 0.140986 3.546625 0.000000 0.000000 4065.0 3.523078 0.134046 3.523078 0.000000 0.000000 4070.0 3.473087 0.145283 3.473087 0.000000 0.000000 4075.0 3.459444 0.142621 3.459444 0.000000 0.000000 4080.0 3.439579 0.143865 3.439579 0.000000 0.000000 4085.0 3.382276 0.136915 3.382276 0.000000 0.000000 4090.0 3.294374 0.097803 3.294374 0.000000 0.000000 4095.0 3.091724 0.116923 3.091724 0.000000 0.000000 4100.0 2.896920 0.206890 2.896920 0.000000 0.000000 4105.0 3.031221 0.161672 3.031221 0.000000 0.000000 4110.0 3.244087 0.121434 3.244087 0.000000 0.000000 4115.0 3.309517 0.141967 3.309517 0.000000 0.000000 4120.0 3.318604 0.135901 3.318604 0.000000 0.000000 4125.0 3.311059 0.135734 3.311059 0.000000 0.000000 4130.0 3.304340 0.131147 3.304340 0.000000 0.000000 4135.0 3.282842 0.130568 3.282842 0.000000 0.000000 4140.0 3.258918 0.129330 3.258918 0.000000 0.000000 4145.0 3.244801 0.121777 3.244801 0.000000 0.000000 4150.0 3.231102 0.124200 3.231102 0.000000 0.000000 4155.0 3.229472 0.124913 3.229472 0.000000 0.000000 4160.0 3.213803 0.130052 3.213803 0.000000 0.000000 4165.0 3.192666 0.128173 3.192666 0.000000 0.000000 4170.0 3.175755 0.130116 3.175755 0.000000 0.000000 4175.0 3.165456 0.136884 3.165456 0.000000 0.000000 4180.0 3.154830 0.136958 3.154830 0.000000 0.000000 4185.0 3.125080 0.131908 3.125080 0.000000 0.000000 4190.0 3.061807 0.134756 3.061807 0.000000 0.000000 4195.0 2.976036 0.149046 2.976036 0.000000 0.000000 4200.0 2.925914 0.158571 2.925914 0.000000 0.000000 4205.0 2.978519 0.117796 2.978519 0.000000 0.000000 4210.0 3.013246 0.107511 3.013246 0.000000 0.000000 4215.0 3.008003 0.108168 3.008003 0.000000 0.000000 4220.0 3.002639 0.099973 3.002639 0.000000 0.000000 4225.0 2.995408 0.101921 2.995408 0.000000 0.000000 4230.0 2.984229 0.093235 2.984229 0.000000 0.000000 4235.0 2.954819 0.089617 2.954819 0.000000 0.000000 4240.0 2.932537 0.088862 2.932537 0.000000 0.000000 4245.0 2.930752 0.084854 2.930752 0.000000 0.000000 4250.0 2.928275 0.077988 2.928275 0.000000 0.000000 4255.0 2.903358 0.073087 2.903358 0.000000 0.000000 4260.0 2.871778 0.077003 2.871778 0.000000 0.000000 4265.0 2.847426 0.084910 2.847426 0.000000 0.000000 4270.0 2.840531 0.079396 2.840531 0.000000 0.000000 4275.0 2.832905 0.077758 2.832905 0.000000 0.000000 4280.0 2.820014 0.075754 2.820014 0.000000 0.000000 4285.0 2.807442 0.066651 2.807442 0.000000 0.000000 4290.0 2.791812 0.069058 2.791812 0.000000 0.000000 4295.0 2.789046 0.068612 2.789046 0.000000 0.000000 4300.0 2.784508 0.066713 2.784508 0.000000 0.000000 4305.0 2.775176 0.067407 2.775176 0.000000 0.000000 4310.0 2.778084 0.066315 2.778084 0.000000 0.000000 4315.0 2.768073 0.078498 2.768073 0.000000 0.000000 4320.0 2.745305 0.078346 2.745305 0.000000 0.000000 4325.0 2.714263 0.048084 2.714263 0.000000 0.000000 4330.0 2.609965 0.026744 2.609965 0.000000 0.000000 4335.0 2.417091 0.062664 2.417091 0.000000 0.000000 4340.0 2.304199 0.121826 2.304199 0.000000 0.000000 4345.0 2.442607 0.071421 2.442607 0.000000 0.000000 4350.0 2.589814 0.051761 2.589814 0.000000 0.000000 4355.0 2.653373 0.053063 2.653373 0.000000 0.000000 4360.0 2.662863 0.053047 2.662863 0.000000 0.000000 4365.0 2.652761 0.051985 2.652761 0.000000 0.000000 4370.0 2.638364 0.054777 2.638364 0.000000 0.000000 4375.0 2.623167 0.056174 2.623167 0.000000 0.000000 4380.0 2.597995 0.060486 2.597995 0.000000 0.000000 4385.0 2.577212 0.067446 2.577212 0.000000 0.000000 4390.0 2.584989 0.055194 2.584989 0.000000 0.000000 4395.0 2.582220 0.044444 2.582220 0.000000 0.000000 4400.0 2.561121 0.040998 2.561121 0.000000 0.000000 4405.0 2.538024 0.044013 2.538024 0.000000 0.000000 4410.0 2.510464 0.044938 2.510464 0.000000 0.000000 4415.0 2.463937 0.048895 2.463937 0.000000 0.000000 4420.0 2.417243 0.046592 2.417243 0.000000 0.000000 4425.0 2.375760 0.045248 2.375760 0.000000 0.000000 4430.0 2.340586 0.057422 2.340586 0.000000 0.000000 4435.0 2.350785 0.050301 2.350785 0.000000 0.000000 4440.0 2.384998 0.032130 2.384998 0.000000 0.000000 4445.0 2.410148 0.027197 2.410148 0.000000 0.000000 4450.0 2.432351 0.029981 2.432351 0.000000 0.000000 4455.0 2.438818 0.033359 2.438818 0.000000 0.000000 4460.0 2.413490 0.036711 2.413490 0.000000 0.000000 4465.0 2.376311 0.032991 2.376311 0.000000 0.000000 4470.0 2.324116 0.051478 2.324116 0.000000 0.000000 4475.0 2.333668 0.028866 2.333668 0.000000 0.000000 4480.0 2.348763 0.018139 2.348763 0.000000 0.000000 4485.0 2.346370 0.019316 2.346370 0.000000 0.000000 4490.0 2.340014 0.016755 2.340014 0.000000 0.000000 4495.0 2.334521 0.013659 2.334521 0.000000 0.000000 4500.0 2.328965 0.016158 2.328965 0.000000 0.000000 4505.0 2.309363 0.025791 2.309363 0.000000 0.000000 4510.0 2.297810 0.021617 2.297810 0.000000 0.000000 4515.0 2.285011 0.022548 2.285011 0.000000 0.000000 4520.0 2.280267 0.022189 2.280267 0.000000 0.000000 4525.0 2.261416 0.010529 2.261416 0.000000 0.000000 4530.0 2.233078 0.004367 2.233078 0.000000 0.000000 4535.0 2.172098 0.008279 2.172098 0.000000 0.000000 4540.0 2.108621 0.025124 2.108621 0.000000 0.000000 4545.0 2.151205 0.020088 2.151205 0.000000 0.000000 4550.0 2.194848 0.012207 2.194848 0.000000 0.000000 4555.0 2.207146 0.005063 2.207146 0.000000 0.000000 4560.0 2.209116 0.003538 2.209116 0.000000 0.000000 4565.0 2.196997 0.005349 2.196997 0.000000 0.000000 4570.0 2.181215 0.006641 2.181215 0.000000 0.000000 4575.0 2.169757 0.011215 2.169757 0.000000 0.000000 4580.0 2.171879 0.020630 2.171879 0.000000 0.000000 4585.0 2.158612 0.016612 2.158612 0.000000 0.000000 4590.0 2.134382 0.006905 2.134382 0.000000 0.000000 4595.0 2.123401 0.010836 2.123401 0.000000 0.000000 4600.0 2.116204 0.010973 2.116204 0.000000 0.000000 4605.0 2.108387 0.010529 2.108387 0.000000 0.000000 4610.0 2.113212 0.019301 2.113212 0.000000 0.000000 4615.0 2.113685 0.020412 2.113685 0.000000 0.000000 4620.0 2.102574 0.025547 2.102574 0.000000 0.000000 4625.0 2.084434 0.018927 2.084434 0.000000 0.000000 4630.0 2.083315 0.010836 2.083315 0.000000 0.000000 4635.0 2.082672 0.016504 2.082672 0.000000 0.000000 4640.0 2.088073 0.021409 2.088073 0.000000 0.000000 4645.0 2.073948 0.034127 2.073948 0.000000 0.000000 4650.0 2.051712 0.037506 2.051712 0.000000 0.000000 4655.0 2.037895 0.046064 2.037895 0.000000 0.000000 4660.0 2.044002 0.055054 2.044002 0.000000 0.000000 4665.0 2.040011 0.063814 2.040011 0.000000 0.000000 4670.0 2.018997 0.063256 2.018997 0.000000 0.000000 4675.0 1.993647 0.061140 1.993647 0.000000 0.000000 4680.0 1.916061 0.053819 1.916061 0.000000 0.000000 4685.0 1.859749 0.044384 1.859749 0.000000 0.000000 4690.0 1.915028 0.045961 1.915028 0.000000 0.000000 4695.0 1.963758 0.061398 1.963758 0.000000 0.000000 4700.0 1.958291 0.061349 1.958291 0.000000 0.000000 4705.0 1.949402 0.065746 1.949402 0.000000 0.000000 4710.0 1.917382 0.057430 1.917382 0.000000 0.000000 4715.0 1.899787 0.046406 1.899787 0.000000 0.000000 4720.0 1.889676 0.045606 1.889676 0.000000 0.000000 4725.0 1.871239 0.053237 1.871239 0.000000 0.000000 4730.0 1.874872 0.065580 1.874872 0.000000 0.000000 4735.0 1.869085 0.053441 1.869085 0.000000 0.000000 4740.0 1.864865 0.061463 1.864865 0.000000 0.000000 4745.0 1.862967 0.073605 1.862967 0.000000 0.000000 4750.0 1.848031 0.070708 1.848031 0.000000 0.000000 4755.0 1.824786 0.068239 1.824786 0.000000 0.000000 4760.0 1.803741 0.058711 1.803741 0.000000 0.000000 4765.0 1.800319 0.063512 1.800319 0.000000 0.000000 4770.0 1.808924 0.067788 1.808924 0.000000 0.000000 4775.0 1.798452 0.066827 1.798452 0.000000 0.000000 4780.0 1.784757 0.062818 1.784757 0.000000 0.000000 4785.0 1.784232 0.066180 1.784232 0.000000 0.000000 4790.0 1.780136 0.057965 1.780136 0.000000 0.000000 4795.0 1.766839 0.056517 1.766839 0.000000 0.000000 4800.0 1.754507 0.056012 1.754507 0.000000 0.000000 4805.0 1.750172 0.046592 1.750172 0.000000 0.000000 4810.0 1.745331 0.053700 1.745331 0.000000 0.000000 4815.0 1.737823 0.058234 1.737823 0.000000 0.000000 4820.0 1.733929 0.055598 1.733929 0.000000 0.000000 4825.0 1.728627 0.057733 1.728627 0.000000 0.000000 4830.0 1.727700 0.067621 1.727700 0.000000 0.000000 4835.0 1.723498 0.072131 1.723498 0.000000 0.000000 4840.0 1.719507 0.077057 1.719507 0.000000 0.000000 4845.0 1.694735 0.076051 1.694735 0.000000 0.000000 4850.0 1.634978 0.078026 1.634978 0.000000 0.000000 4855.0 1.501500 0.070714 1.501500 0.000000 0.000000 4860.0 1.382087 0.045314 1.382087 0.000000 0.000000 4865.0 1.457954 0.035015 1.457954 0.000000 0.000000 4870.0 1.571613 0.043272 1.571613 0.000000 0.000000 4875.0 1.605421 0.052433 1.605421 0.000000 0.000000 4880.0 1.610805 0.061531 1.610805 0.000000 0.000000 4885.0 1.616123 0.064582 1.616123 0.000000 0.000000 4890.0 1.619858 0.065129 1.619858 0.000000 0.000000 4895.0 1.618274 0.061558 1.618274 0.000000 0.000000 4900.0 1.615890 0.066776 1.615890 0.000000 0.000000 4905.0 1.621166 0.074772 1.621166 0.000000 0.000000 4910.0 1.619439 0.076741 1.619439 0.000000 0.000000 4915.0 1.611475 0.078026 1.611475 0.000000 0.000000 4920.0 1.587395 0.068826 1.587395 0.000000 0.000000 4925.0 1.594559 0.074317 1.594559 0.000000 0.000000 4930.0 1.608176 0.082783 1.608176 0.000000 0.000000 4935.0 1.600916 0.075247 1.600916 0.000000 0.000000 4940.0 1.587463 0.068043 1.587463 0.000000 0.000000 4945.0 1.582775 0.070317 1.582775 0.000000 0.000000 4950.0 1.580435 0.073965 1.580435 0.000000 0.000000 4955.0 1.575225 0.074591 1.575225 0.000000 0.000000 4960.0 1.573141 0.082314 1.573141 0.000000 0.000000 4965.0 1.561011 0.079177 1.561011 0.000000 0.000000 4970.0 1.544183 0.065873 1.544183 0.000000 0.000000 4975.0 1.535783 0.063182 1.535783 0.000000 0.000000 4980.0 1.522823 0.056303 1.522823 0.000000 0.000000 4985.0 1.530253 0.067797 1.530253 0.000000 0.000000 4990.0 1.529029 0.070544 1.529029 0.000000 0.000000 4995.0 1.524927 0.073419 1.524927 0.000000 0.000000 5000.0 1.521316 0.071794 1.521316 0.000000 0.000000 5005.0 1.507041 0.064600 1.507041 0.000000 0.000000 5010.0 1.488407 0.055337 1.488407 0.000000 0.000000 5015.0 1.470268 0.049986 1.470268 0.000000 0.000000 5020.0 1.470656 0.057378 1.470656 0.000000 0.000000 5025.0 1.468634 0.054703 1.468634 0.000000 0.000000 5030.0 1.460164 0.050079 1.460164 0.000000 0.000000 5035.0 1.458620 0.051412 1.458620 0.000000 0.000000 5040.0 1.455726 0.057272 1.455726 0.000000 0.000000 5045.0 1.449439 0.056662 1.449439 0.000000 0.000000 5050.0 1.443154 0.055769 1.443154 0.000000 0.000000 5055.0 1.440408 0.051672 1.440408 0.000000 0.000000 5060.0 1.435246 0.053452 1.435246 0.000000 0.000000 5065.0 1.432580 0.054956 1.432580 0.000000 0.000000 5070.0 1.432368 0.055587 1.432368 0.000000 0.000000 5075.0 1.431692 0.062894 1.431692 0.000000 0.000000 5080.0 1.428548 0.062956 1.428548 0.000000 0.000000 5085.0 1.422792 0.058226 1.422792 0.000000 0.000000 5090.0 1.417030 0.059130 1.417030 0.000000 0.000000 5095.0 1.406642 0.055532 1.406642 0.000000 0.000000 5100.0 1.405829 0.059046 1.405829 0.000000 0.000000 5105.0 1.394181 0.055029 1.394181 0.000000 0.000000 5110.0 1.383517 0.049819 1.383517 0.000000 0.000000 5115.0 1.379383 0.044712 1.379383 0.000000 0.000000 5120.0 1.373877 0.044652 1.373877 0.000000 0.000000 5125.0 1.371288 0.045105 1.371288 0.000000 0.000000 5130.0 1.370308 0.049022 1.370308 0.000000 0.000000 5135.0 1.365723 0.050169 1.365723 0.000000 0.000000 5140.0 1.361532 0.051951 1.361532 0.000000 0.000000 5145.0 1.356145 0.051925 1.356145 0.000000 0.000000 5150.0 1.349294 0.048878 1.349294 0.000000 0.000000 5155.0 1.344162 0.049774 1.344162 0.000000 0.000000 5160.0 1.340673 0.052207 1.340673 0.000000 0.000000 5165.0 1.333722 0.047235 1.333722 0.000000 0.000000 5170.0 1.328486 0.047821 1.328486 0.000000 0.000000 5175.0 1.328736 0.050239 1.328736 0.000000 0.000000 5180.0 1.323181 0.048910 1.323181 0.000000 0.000000 5185.0 1.315930 0.044835 1.315930 0.000000 0.000000 5190.0 1.307836 0.041687 1.307836 0.000000 0.000000 5195.0 1.308233 0.048988 1.308233 0.000000 0.000000 5200.0 1.298663 0.045493 1.298663 0.000000 0.000000 5205.0 1.287448 0.039954 1.287448 0.000000 0.000000 5210.0 1.290102 0.042242 1.290102 0.000000 0.000000 5215.0 1.288460 0.045258 1.288460 0.000000 0.000000 5220.0 1.280389 0.041245 1.280389 0.000000 0.000000 5225.0 1.273036 0.037722 1.273036 0.000000 0.000000 5230.0 1.265580 0.032598 1.265580 0.000000 0.000000 5235.0 1.260703 0.032764 1.260703 0.000000 0.000000 5240.0 1.255359 0.033535 1.255359 0.000000 0.000000 5245.0 1.255282 0.038005 1.255282 0.000000 0.000000 5250.0 1.245590 0.034568 1.245590 0.000000 0.000000 5255.0 1.249312 0.040620 1.249312 0.000000 0.000000 5260.0 1.248238 0.040688 1.248238 0.000000 0.000000 5265.0 1.235956 0.032410 1.235956 0.000000 0.000000 5270.0 1.227798 0.026388 1.227798 0.000000 0.000000 5275.0 1.227248 0.027290 1.227248 0.000000 0.000000 5280.0 1.221089 0.029034 1.221089 0.000000 0.000000 5285.0 1.219573 0.032757 1.219573 0.000000 0.000000 5290.0 1.212409 0.029113 1.212409 0.000000 0.000000 5295.0 1.203874 0.023353 1.203874 0.000000 0.000000 5300.0 1.197500 0.020956 1.197500 0.000000 0.000000 5305.0 1.197945 0.025284 1.197945 0.000000 0.000000 5310.0 1.194252 0.023977 1.194252 0.000000 0.000000 5315.0 1.194883 0.025673 1.194883 0.000000 0.000000 5320.0 1.192047 0.026908 1.192047 0.000000 0.000000 5325.0 1.184911 0.024116 1.184911 0.000000 0.000000 5330.0 1.175465 0.018376 1.175465 0.000000 0.000000 5335.0 1.171941 0.017439 1.171941 0.000000 0.000000 5340.0 1.165313 0.017159 1.165313 0.000000 0.000000 5345.0 1.164120 0.019747 1.164120 0.000000 0.000000 5350.0 1.164800 0.023360 1.164800 0.000000 0.000000 5355.0 1.163259 0.027860 1.163259 0.000000 0.000000 5360.0 1.151912 0.020415 1.151912 0.000000 0.000000 5365.0 1.146598 0.019645 1.146598 0.000000 0.000000 5370.0 1.143518 0.018032 1.143518 0.000000 0.000000 5375.0 1.140256 0.017068 1.140256 0.000000 0.000000 5380.0 1.138326 0.017456 1.138326 0.000000 0.000000 5385.0 1.132392 0.012907 1.132392 0.000000 0.000000 5390.0 1.134609 0.019932 1.134609 0.000000 0.000000 5395.0 1.128119 0.020481 1.128119 0.000000 0.000000 5400.0 1.108495 0.017567 1.108495 0.000000 0.000000 5405.0 1.066491 0.016513 1.066491 0.000000 0.000000 5410.0 1.021042 0.002990 1.021042 0.000000 0.000000 5415.0 1.044040 0.008588 1.044040 0.000000 0.000000 5420.0 1.086016 0.014241 1.086016 0.000000 0.000000 5425.0 1.095270 0.014194 1.095270 0.000000 0.000000 5430.0 1.095123 0.014709 1.095123 0.000000 0.000000 5435.0 1.089796 0.013621 1.089796 0.000000 0.000000 5440.0 1.086566 0.015551 1.086566 0.000000 0.000000 5445.0 1.077528 0.011998 1.077528 0.000000 0.000000 5450.0 1.072877 0.010795 1.072877 0.000000 0.000000 5455.0 1.067716 0.006390 1.067716 0.000000 0.000000 5460.0 1.068057 0.008769 1.068057 0.000000 0.000000 5465.0 1.063363 0.005222 1.063363 0.000000 0.000000 5470.0 1.066066 0.009028 1.066066 0.000000 0.000000 5475.0 1.063575 0.010815 1.063575 0.000000 0.000000 5480.0 1.052402 0.006366 1.052402 0.000000 0.000000 5485.0 1.040744 0.002674 1.040744 0.000000 0.000000 5490.0 1.037943 0.001495 1.037943 0.000000 0.000000 5495.0 1.048260 0.010228 1.048260 0.000000 0.000000 5500.0 1.047725 0.014314 1.047725 0.000000 0.000000 5505.0 1.036965 0.009376 1.036965 0.000000 0.000000 5510.0 1.031918 0.005594 1.031918 0.000000 0.000000 5515.0 1.032413 0.007180 1.032413 0.000000 0.000000 5520.0 1.027665 0.001495 1.027665 0.000000 0.000000 5525.0 1.019546 0.000546 1.019546 0.000000 0.000000 5530.0 1.015922 0.001158 1.015922 0.000000 0.000000 5535.0 1.008126 0.002730 1.008126 0.000000 0.000000 5540.0 1.006934 0.001021 1.006934 0.000000 0.000000 5545.0 1.006305 0.000386 1.006305 0.000000 0.000000 5550.0 1.005341 0.002472 1.005341 0.000000 0.000000 5555.0 1.002277 0.002914 1.002277 0.000000 0.000000 5560.0 1.001319 0.002411 1.001319 0.000000 0.000000 5565.0 0.998932 0.000819 0.998932 0.000000 0.000000 5570.0 0.993667 0.004672 0.993667 0.000000 0.000000 5575.0 0.993699 0.006372 0.993699 0.000000 0.000000 5580.0 0.988919 0.004012 0.988919 0.000000 0.000000 5585.0 0.977233 0.001930 0.977233 0.000000 0.000000 5590.0 0.966262 0.000273 0.966262 0.000000 0.000000 5595.0 0.964858 0.001683 0.964858 0.000000 0.000000 5600.0 0.970053 0.003015 0.970053 0.000000 0.000000 5605.0 0.967947 0.003601 0.967947 0.000000 0.000000 5610.0 0.963008 0.006719 0.963008 0.000000 0.000000 5615.0 0.957674 0.010529 0.957674 0.000000 0.000000 5620.0 0.956647 0.008448 0.956647 0.000000 0.000000 5625.0 0.953920 0.008999 0.953920 0.000000 0.000000 5630.0 0.950771 0.007440 0.950771 0.000000 0.000000 5635.0 0.948347 0.007840 0.948347 0.000000 0.000000 5640.0 0.945012 0.007638 0.945012 0.000000 0.000000 5645.0 0.941731 0.005300 0.941731 0.000000 0.000000 5650.0 0.939804 0.004845 0.939804 0.000000 0.000000 5655.0 0.935990 0.004237 0.935990 0.000000 0.000000 5660.0 0.931658 0.002823 0.931658 0.000000 0.000000 5665.0 0.927520 0.002823 0.927520 0.000000 0.000000 5670.0 0.921833 0.005070 0.921833 0.000000 0.000000 5675.0 0.916046 0.009662 0.916046 0.000000 0.000000 5680.0 0.915521 0.006884 0.915521 0.000000 0.000000 5685.0 0.917493 0.005342 0.917493 0.000000 0.000000 5690.0 0.917845 0.008700 0.917845 0.000000 0.000000 5695.0 0.921021 0.006284 0.921021 0.000000 0.000000 5700.0 0.910517 0.001726 0.910517 0.000000 0.000000 5705.0 0.892511 0.006916 0.892511 0.000000 0.000000 5710.0 0.897787 0.002770 0.897787 0.000000 0.000000 5715.0 0.898082 0.001092 0.898082 0.000000 0.000000 5720.0 0.889743 0.007594 0.889743 0.000000 0.000000 5725.0 0.884772 0.008549 0.884772 0.000000 0.000000 5730.0 0.882481 0.006454 0.882481 0.000000 0.000000 5735.0 0.877837 0.007897 0.877837 0.000000 0.000000 5740.0 0.873134 0.006964 0.873134 0.000000 0.000000 5745.0 0.870006 0.007599 0.870006 0.000000 0.000000 5750.0 0.868411 0.007869 0.868411 0.000000 0.000000 5755.0 0.865849 0.009747 0.865849 0.000000 0.000000 5760.0 0.865101 0.006224 0.865101 0.000000 0.000000 5765.0 0.858722 0.006073 0.858722 0.000000 0.000000 5770.0 0.849837 0.007237 0.849837 0.000000 0.000000 5775.0 0.835218 0.001851 0.835218 0.000000 0.000000 5780.0 0.814963 0.012350 0.814963 0.000000 0.000000 5785.0 0.826499 0.012742 0.826499 0.000000 0.000000 5790.0 0.835066 0.009212 0.835066 0.000000 0.000000 5795.0 0.816090 0.009416 0.816090 0.000000 0.000000 5800.0 0.803287 0.010691 0.803287 0.000000 0.000000 5805.0 0.809841 0.012338 0.809841 0.000000 0.000000 5810.0 0.809366 0.015385 0.809366 0.000000 0.000000 5815.0 0.816633 0.017580 0.816633 0.000000 0.000000 5820.0 0.829489 0.013843 0.829489 0.000000 0.000000 5825.0 0.832000 0.008221 0.832000 0.000000 0.000000 5830.0 0.829654 0.008382 0.829654 0.000000 0.000000 5835.0 0.825649 0.008764 0.825649 0.000000 0.000000 5840.0 0.823412 0.006152 0.823412 0.000000 0.000000 5845.0 0.817082 0.005974 0.817082 0.000000 0.000000 5850.0 0.812878 0.007574 0.812878 0.000000 0.000000 5855.0 0.809519 0.011168 0.809519 0.000000 0.000000 5860.0 0.810100 0.009720 0.810100 0.000000 0.000000 5865.0 0.808375 0.002348 0.808375 0.000000 0.000000 5870.0 0.783770 0.001660 0.783770 0.000000 0.000000 5875.0 0.756876 0.007028 0.756876 0.000000 0.000000 5880.0 0.776266 0.005018 0.776266 0.000000 0.000000 5885.0 0.753364 0.006200 0.753364 0.000000 0.000000 5890.0 0.695083 0.003548 0.695083 0.000000 0.000000 5895.0 0.705948 0.002971 0.705948 0.000000 0.000000 5900.0 0.755212 0.007744 0.755212 0.000000 0.000000 5905.0 0.785667 0.005328 0.785667 0.000000 0.000000 5910.0 0.783037 0.001638 0.783037 0.000000 0.000000 5915.0 0.781893 0.006465 0.781893 0.000000 0.000000 5920.0 0.773510 0.002604 0.773510 0.000000 0.000000 5925.0 0.770671 0.005026 0.770671 0.000000 0.000000 5930.0 0.771364 0.005601 0.771364 0.000000 0.000000 5935.0 0.768383 0.005092 0.768383 0.000000 0.000000 5940.0 0.763973 0.003927 0.763973 0.000000 0.000000 5945.0 0.757592 0.007123 0.757592 0.000000 0.000000 5950.0 0.753331 0.010798 0.753331 0.000000 0.000000 5955.0 0.754244 0.011772 0.754244 0.000000 0.000000 5960.0 0.750452 0.007711 0.750452 0.000000 0.000000 5965.0 0.750108 0.004039 0.750108 0.000000 0.000000 5970.0 0.743496 0.007375 0.743496 0.000000 0.000000 5975.0 0.744142 0.005513 0.744142 0.000000 0.000000 5980.0 0.742761 0.003762 0.742761 0.000000 0.000000 5985.0 0.738033 0.008042 0.738033 0.000000 0.000000 5990.0 0.739908 0.003870 0.739908 0.000000 0.000000 5995.0 0.741654 0.004664 0.741654 0.000000 0.000000 6000.0 0.735786 0.003453 0.735786 0.000000 0.000000 6005.0 0.730656 0.004510 0.730656 0.000000 0.000000 6010.0 0.726057 0.006708 0.726057 0.000000 0.000000 6015.0 0.725243 0.008139 0.725243 0.000000 0.000000 6020.0 0.725720 0.007227 0.725720 0.000000 0.000000 6025.0 0.726374 0.008597 0.726374 0.000000 0.000000 6030.0 0.726515 0.011513 0.726515 0.000000 0.000000 6035.0 0.715903 0.015392 0.715903 0.000000 0.000000 6040.0 0.711509 0.012479 0.711509 0.000000 0.000000 6045.0 0.715883 0.012724 0.715883 0.000000 0.000000 6050.0 0.711402 0.008658 0.711402 0.000000 0.000000 6055.0 0.711858 0.008166 0.711858 0.000000 0.000000 6060.0 0.708347 0.007972 0.708347 0.000000 0.000000 6065.0 0.703055 0.010501 0.703055 0.000000 0.000000 6070.0 0.700589 0.011223 0.700589 0.000000 0.000000 6075.0 0.698870 0.008943 0.698870 0.000000 0.000000 6080.0 0.698184 0.009127 0.698184 0.000000 0.000000 6085.0 0.697365 0.010367 0.697365 0.000000 0.000000 6090.0 0.697777 0.006664 0.697777 0.000000 0.000000 6095.0 0.695689 0.006511 0.695689 0.000000 0.000000 6100.0 0.692154 0.009536 0.692154 0.000000 0.000000 6105.0 0.688173 0.010795 0.688173 0.000000 0.000000 6110.0 0.686146 0.008764 0.686146 0.000000 0.000000 6115.0 0.686333 0.011273 0.686333 0.000000 0.000000 6120.0 0.677671 0.007458 0.677671 0.000000 0.000000 6125.0 0.681732 0.007147 0.681732 0.000000 0.000000 6130.0 0.680589 0.005877 0.680589 0.000000 0.000000 6135.0 0.677642 0.006119 0.677642 0.000000 0.000000 6140.0 0.677710 0.004708 0.677710 0.000000 0.000000 6145.0 0.673670 0.005765 0.673670 0.000000 0.000000 6150.0 0.673081 0.005201 0.673081 0.000000 0.000000 6155.0 0.669480 0.003797 0.669480 0.000000 0.000000 6160.0 0.665481 0.001580 0.665481 0.000000 0.000000 6165.0 0.655783 0.006829 0.655783 0.000000 0.000000 6170.0 0.649435 0.008601 0.649435 0.000000 0.000000 6175.0 0.650337 0.004620 0.650337 0.000000 0.000000 6180.0 0.651746 0.009806 0.651746 0.000000 0.000000 6185.0 0.653777 0.009094 0.653777 0.000000 0.000000 6190.0 0.653094 0.005781 0.653094 0.000000 0.000000 6195.0 0.652608 0.006033 0.652608 0.000000 0.000000 6200.0 0.647681 0.005965 0.647681 0.000000 0.000000 6205.0 0.643435 0.005597 0.643435 0.000000 0.000000 6210.0 0.647592 0.002524 0.647592 0.000000 0.000000 6215.0 0.646917 0.003951 0.646917 0.000000 0.000000 6220.0 0.646520 0.005121 0.646520 0.000000 0.000000 6225.0 0.641329 0.005150 0.641329 0.000000 0.000000 6230.0 0.635599 0.003337 0.635599 0.000000 0.000000 6235.0 0.634695 0.001660 0.634695 0.000000 0.000000 6240.0 0.635969 0.000546 0.635969 0.000000 0.000000 6245.0 0.639498 0.004620 0.639498 0.000000 0.000000 6250.0 0.640067 0.005591 0.640067 0.000000 0.000000 6255.0 0.636969 0.003647 0.636969 0.000000 0.000000 6260.0 0.636878 0.010358 0.636878 0.000000 0.000000 6265.0 0.627287 0.004592 0.627287 0.000000 0.000000 6270.0 0.621502 0.007510 0.621502 0.000000 0.000000 6275.0 0.606036 0.013662 0.606036 0.000000 0.000000 6280.0 0.580205 0.017385 0.580205 0.000000 0.000000 6285.0 0.587204 0.021758 0.587204 0.000000 0.000000 6290.0 0.606890 0.008881 0.606890 0.000000 0.000000 6295.0 0.611236 0.002494 0.611236 0.000000 0.000000 6300.0 0.609379 0.002006 0.609379 0.000000 0.000000 6305.0 0.601864 0.004974 0.601864 0.000000 0.000000 6310.0 0.593986 0.005513 0.593986 0.000000 0.000000 6315.0 0.594474 0.003748 0.594474 0.000000 0.000000 6320.0 0.601604 0.002494 0.601604 0.000000 0.000000 6325.0 0.607403 0.003533 0.607403 0.000000 0.000000 6330.0 0.605091 0.000984 0.605091 0.000000 0.000000 6335.0 0.605344 0.002259 0.605344 0.000000 0.000000 6340.0 0.603081 0.003965 0.603081 0.000000 0.000000 6345.0 0.600088 0.005040 0.600088 0.000000 0.000000 6350.0 0.597714 0.004224 0.597714 0.000000 0.000000 6355.0 0.594037 0.005690 0.594037 0.000000 0.000000 6360.0 0.592365 0.010046 0.592365 0.000000 0.000000 6365.0 0.589960 0.006848 0.589960 0.000000 0.000000 6370.0 0.588574 0.008512 0.588574 0.000000 0.000000 6375.0 0.584644 0.009145 0.584644 0.000000 0.000000 6380.0 0.581084 0.006497 0.581084 0.000000 0.000000 6385.0 0.582496 0.005096 0.582496 0.000000 0.000000 6390.0 0.582448 0.004175 0.582448 0.000000 0.000000 6395.0 0.579250 0.004940 0.579250 0.000000 0.000000 6400.0 0.571250 0.004833 0.571250 0.000000 0.000000 6405.0 0.568194 0.003738 0.568194 0.000000 0.000000 6410.0 0.567774 0.004081 0.567774 0.000000 0.000000 6415.0 0.570366 0.005307 0.570366 0.000000 0.000000 6420.0 0.573342 0.003183 0.573342 0.000000 0.000000 6425.0 0.574612 0.000984 0.574612 0.000000 0.000000 6430.0 0.573255 0.000722 0.573255 0.000000 0.000000 6435.0 0.570730 0.001392 0.570730 0.000000 0.000000 6440.0 0.567817 0.003321 0.567817 0.000000 0.000000 6445.0 0.564982 0.003637 0.564982 0.000000 0.000000 6450.0 0.562314 0.002251 0.562314 0.000000 0.000000 6455.0 0.559573 0.006372 0.559573 0.000000 0.000000 6460.0 0.558710 0.007002 0.558710 0.000000 0.000000 6465.0 0.558142 0.003713 0.558142 0.000000 0.000000 6470.0 0.556381 0.001158 0.556381 0.000000 0.000000 6475.0 0.555453 0.001821 0.555453 0.000000 0.000000 6480.0 0.556333 0.005338 0.556333 0.000000 0.000000 6485.0 0.552112 0.005254 0.552112 0.000000 0.000000 6490.0 0.549874 0.002201 0.549874 0.000000 0.000000 6495.0 0.550986 0.004067 0.550986 0.000000 0.000000 6500.0 0.552667 0.005902 0.552667 0.000000 0.000000 6505.0 0.552303 0.003349 0.552303 0.000000 0.000000 6510.0 0.550978 0.006061 0.550978 0.000000 0.000000 6515.0 0.544322 0.006514 0.544322 0.000000 0.000000 6520.0 0.537988 0.006619 0.537988 0.000000 0.000000 6525.0 0.529896 0.004700 0.529896 0.000000 0.000000 6530.0 0.528945 0.006551 0.528945 0.000000 0.000000 6535.0 0.535450 0.007720 0.535450 0.000000 0.000000 6540.0 0.538616 0.008362 0.538616 0.000000 0.000000 6545.0 0.534851 0.007253 0.534851 0.000000 0.000000 6550.0 0.522171 0.007235 0.522171 0.000000 0.000000 6555.0 0.489121 0.014100 0.489121 0.000000 0.000000 6560.0 0.446247 0.006836 0.446247 0.000000 0.000000 6565.0 0.449426 0.021218 0.449426 0.000000 0.000000 6570.0 0.498242 0.016627 0.498242 0.000000 0.000000 6575.0 0.524353 0.010105 0.524353 0.000000 0.000000 6580.0 0.531931 0.008492 0.531931 0.000000 0.000000 6585.0 0.529738 0.006835 0.529738 0.000000 0.000000 6590.0 0.529597 0.008754 0.529597 0.000000 0.000000 6595.0 0.528352 0.007883 0.528352 0.000000 0.000000 6600.0 0.527850 0.007902 0.527850 0.000000 0.000000 6605.0 0.527306 0.009131 0.527306 0.000000 0.000000 6610.0 0.522098 0.008364 0.522098 0.000000 0.000000 6615.0 0.519816 0.007956 0.519816 0.000000 0.000000 6620.0 0.517831 0.007245 0.517831 0.000000 0.000000 6625.0 0.520186 0.007076 0.520186 0.000000 0.000000 6630.0 0.515914 0.006892 0.515914 0.000000 0.000000 6635.0 0.515612 0.008490 0.515612 0.000000 0.000000 6640.0 0.514102 0.007440 0.514102 0.000000 0.000000 6645.0 0.511314 0.006212 0.511314 0.000000 0.000000 6650.0 0.508787 0.005261 0.508787 0.000000 0.000000 6655.0 0.504585 0.003052 0.504585 0.000000 0.000000 6660.0 0.501759 0.004224 0.501759 0.000000 0.000000 6665.0 0.498610 0.002876 0.498610 0.000000 0.000000 6670.0 0.495889 0.002653 0.495889 0.000000 0.000000 6675.0 0.486066 0.003667 0.486066 0.000000 0.000000 6680.0 0.476114 0.003376 0.476114 0.000000 0.000000 6685.0 0.478700 0.007791 0.478700 0.000000 0.000000 6690.0 0.487284 0.007000 0.487284 0.000000 0.000000 6695.0 0.492773 0.003879 0.492773 0.000000 0.000000 6700.0 0.491704 0.002571 0.491704 0.000000 0.000000 6705.0 0.490808 0.002918 0.490808 0.000000 0.000000 6710.0 0.491346 0.003562 0.491346 0.000000 0.000000 6715.0 0.489686 0.001790 0.489686 0.000000 0.000000 6720.0 0.488660 0.002629 0.488660 0.000000 0.000000 6725.0 0.489522 0.004487 0.489522 0.000000 0.000000 6730.0 0.487166 0.003870 0.487166 0.000000 0.000000 6735.0 0.485128 0.005254 0.485128 0.000000 0.000000 6740.0 0.481536 0.004686 0.481536 0.000000 0.000000 6745.0 0.480794 0.004648 0.480794 0.000000 0.000000 6750.0 0.479177 0.004702 0.479177 0.000000 0.000000 6755.0 0.477054 0.005785 0.477054 0.000000 0.000000 6760.0 0.477540 0.007447 0.477540 0.000000 0.000000 6765.0 0.475540 0.007483 0.475540 0.000000 0.000000 6770.0 0.473415 0.006117 0.473415 0.000000 0.000000 6775.0 0.471062 0.004936 0.471062 0.000000 0.000000 6780.0 0.469223 0.005784 0.469223 0.000000 0.000000 6785.0 0.467267 0.004670 0.467267 0.000000 0.000000 6790.0 0.464838 0.002990 0.464838 0.000000 0.000000 6795.0 0.465979 0.005192 0.465979 0.000000 0.000000 6800.0 0.467827 0.006068 0.467827 0.000000 0.000000 6805.0 0.465559 0.005569 0.465559 0.000000 0.000000 6810.0 0.461679 0.003501 0.461679 0.000000 0.000000 6815.0 0.461650 0.002856 0.461650 0.000000 0.000000 6820.0 0.461801 0.003710 0.461801 0.000000 0.000000 6825.0 0.460385 0.004222 0.460385 0.000000 0.000000 6830.0 0.460259 0.005862 0.460259 0.000000 0.000000 6835.0 0.458034 0.007880 0.458034 0.000000 0.000000 6840.0 0.452001 0.001174 0.452001 0.000000 0.000000 6845.0 0.450917 0.001205 0.450917 0.000000 0.000000 6850.0 0.449833 0.001228 0.449833 0.000000 0.000000 6855.0 0.448749 0.001251 0.448749 0.000000 0.000000 6860.0 0.447665 0.001288 0.447665 0.000000 0.000000 6865.0 0.446581 0.001323 0.446581 0.000000 0.000000 6870.0 0.445497 0.001351 0.445497 0.000000 0.000000 6875.0 0.444413 0.001378 0.444413 0.000000 0.000000 6880.0 0.443329 0.001412 0.443329 0.000000 0.000000 6885.0 0.442245 0.001431 0.442245 0.000000 0.000000 6890.0 0.441161 0.001464 0.441161 0.000000 0.000000 6895.0 0.440077 0.001495 0.440077 0.000000 0.000000 6900.0 0.438993 0.001526 0.438993 0.000000 0.000000 6905.0 0.437909 0.001556 0.437909 0.000000 0.000000 6910.0 0.436825 0.001574 0.436825 0.000000 0.000000 6915.0 0.435741 0.001603 0.435741 0.000000 0.000000 6920.0 0.434657 0.001638 0.434657 0.000000 0.000000 6925.0 0.433573 0.001672 0.433573 0.000000 0.000000 6930.0 0.432489 0.001699 0.432489 0.000000 0.000000 6935.0 0.431405 0.001726 0.431405 0.000000 0.000000 6940.0 0.430321 0.001753 0.430321 0.000000 0.000000 6945.0 0.429237 0.001785 0.429237 0.000000 0.000000 6950.0 0.428153 0.001816 0.428153 0.000000 0.000000 6955.0 0.427069 0.001846 0.427069 0.000000 0.000000 6960.0 0.425986 0.001876 0.425986 0.000000 0.000000 6965.0 0.424902 0.001901 0.424902 0.000000 0.000000 6970.0 0.423818 0.001930 0.423818 0.000000 0.000000 6975.0 0.430262 0.012012 0.430262 0.000000 0.000000 6980.0 0.427752 0.011883 0.427752 0.000000 0.000000 6985.0 0.424017 0.008851 0.424017 0.000000 0.000000 6990.0 0.417992 0.005337 0.417992 0.000000 0.000000 6995.0 0.417981 0.005869 0.417981 0.000000 0.000000 7000.0 0.417153 0.005776 0.417153 0.000000 0.000000 7005.0 0.416619 0.004357 0.416619 0.000000 0.000000 7010.0 0.416979 0.007051 0.416979 0.000000 0.000000 7015.0 0.413611 0.003720 0.413611 0.000000 0.000000 7020.0 0.414764 0.006786 0.414764 0.000000 0.000000 7025.0 0.413817 0.007171 0.413817 0.000000 0.000000 7030.0 0.413743 0.009835 0.413743 0.000000 0.000000 7035.0 0.413965 0.006284 0.413965 0.000000 0.000000 7040.0 0.411701 0.006161 0.411701 0.000000 0.000000 7045.0 0.407351 0.003398 0.407351 0.000000 0.000000 7050.0 0.405887 0.003485 0.405887 0.000000 0.000000 7055.0 0.407669 0.007974 0.407669 0.000000 0.000000 7060.0 0.400735 0.006651 0.400735 0.000000 0.000000 7065.0 0.394219 0.007873 0.394219 0.000000 0.000000 7070.0 0.398218 0.011717 0.398218 0.000000 0.000000 7075.0 0.403403 0.007454 0.403403 0.000000 0.000000 7080.0 0.402212 0.007420 0.402212 0.000000 0.000000 7085.0 0.402509 0.007928 0.402509 0.000000 0.000000 7090.0 0.403025 0.010785 0.403025 0.000000 0.000000 7095.0 0.402777 0.011852 0.402777 0.000000 0.000000 7100.0 0.398624 0.008030 0.398624 0.000000 0.000000 7105.0 0.398757 0.007273 0.398757 0.000000 0.000000 7110.0 0.397959 0.008014 0.397959 0.000000 0.000000 7115.0 0.396981 0.010884 0.396981 0.000000 0.000000 7120.0 0.399811 0.013190 0.399811 0.000000 0.000000 7125.0 0.399281 0.015351 0.399281 0.000000 0.000000 7130.0 0.399893 0.016846 0.399893 0.000000 0.000000 7135.0 0.400882 0.018898 0.400882 0.000000 0.000000 7140.0 0.399617 0.018300 0.399617 0.000000 0.000000 7145.0 0.397686 0.016312 0.397686 0.000000 0.000000 7150.0 0.396064 0.016291 0.396064 0.000000 0.000000 7155.0 0.394626 0.015338 0.394626 0.000000 0.000000 7160.0 0.390738 0.013198 0.390738 0.000000 0.000000 7165.0 0.386157 0.009402 0.386157 0.000000 0.000000 7170.0 0.372420 0.002643 0.372420 0.000000 0.000000 7175.0 0.363136 0.007093 0.363136 0.000000 0.000000 7180.0 0.361233 0.009928 0.361233 0.000000 0.000000 7185.0 0.359411 0.011041 0.359411 0.000000 0.000000 7190.0 0.365866 0.003988 0.365866 0.000000 0.000000 7195.0 0.370019 0.003390 0.370019 0.000000 0.000000 7200.0 0.369296 0.004103 0.369296 0.000000 0.000000 7205.0 0.372001 0.008776 0.372001 0.000000 0.000000 7210.0 0.381519 0.017305 0.381519 0.000000 0.000000 7215.0 0.383277 0.017602 0.383277 0.000000 0.000000 7220.0 0.382119 0.017054 0.382119 0.000000 0.000000 7225.0 0.380817 0.018173 0.380817 0.000000 0.000000 7230.0 0.376708 0.015594 0.376708 0.000000 0.000000 7235.0 0.369263 0.012137 0.369263 0.000000 0.000000 7240.0 0.365790 0.008912 0.365790 0.000000 0.000000 7245.0 0.364249 0.009037 0.364249 0.000000 0.000000 7250.0 0.365700 0.010377 0.365700 0.000000 0.000000 7255.0 0.363726 0.010134 0.363726 0.000000 0.000000 7260.0 0.364879 0.011392 0.364879 0.000000 0.000000 7265.0 0.360753 0.009247 0.360753 0.000000 0.000000 7270.0 0.359734 0.009359 0.359734 0.000000 0.000000 7275.0 0.354739 0.006558 0.354739 0.000000 0.000000 7280.0 0.358906 0.013460 0.358906 0.000000 0.000000 7285.0 0.359909 0.013307 0.359909 0.000000 0.000000 7290.0 0.353713 0.008063 0.353713 0.000000 0.000000 7295.0 0.357960 0.015677 0.357960 0.000000 0.000000 7300.0 0.357475 0.014205 0.357475 0.000000 0.000000 7305.0 0.352430 0.011941 0.352430 0.000000 0.000000 7310.0 0.353631 0.013463 0.353631 0.000000 0.000000 7315.0 0.351289 0.011743 0.351289 0.000000 0.000000 7320.0 0.350849 0.011074 0.350849 0.000000 0.000000 7325.0 0.351648 0.013195 0.351648 0.000000 0.000000 7330.0 0.349579 0.012263 0.349579 0.000000 0.000000 7335.0 0.350570 0.015290 0.350570 0.000000 0.000000 7340.0 0.349845 0.015839 0.349845 0.000000 0.000000 7345.0 0.348531 0.015347 0.348531 0.000000 0.000000 7350.0 0.346355 0.015019 0.346355 0.000000 0.000000 7355.0 0.347050 0.016961 0.347050 0.000000 0.000000 7360.0 0.344469 0.014572 0.344469 0.000000 0.000000 7365.0 0.341514 0.013221 0.341514 0.000000 0.000000 7370.0 0.342076 0.012146 0.342076 0.000000 0.000000 7375.0 0.342577 0.013928 0.342577 0.000000 0.000000 7380.0 0.341096 0.013132 0.341096 0.000000 0.000000 7385.0 0.336444 0.009303 0.336444 0.000000 0.000000 7390.0 0.336349 0.009142 0.336349 0.000000 0.000000 7395.0 0.337995 0.011923 0.337995 0.000000 0.000000 7400.0 0.334411 0.010261 0.334411 0.000000 0.000000 7405.0 0.331268 0.007131 0.331268 0.000000 0.000000 7410.0 0.328531 0.006459 0.328531 0.000000 0.000000 7415.0 0.330955 0.009220 0.330955 0.000000 0.000000 7420.0 0.332923 0.012498 0.332923 0.000000 0.000000 7425.0 0.323753 0.007612 0.323753 0.000000 0.000000 7430.0 0.323534 0.009288 0.323534 0.000000 0.000000 7435.0 0.322430 0.007374 0.322430 0.000000 0.000000 7440.0 0.323027 0.008733 0.323027 0.000000 0.000000 7445.0 0.322448 0.008491 0.322448 0.000000 0.000000 7450.0 0.321699 0.007093 0.321699 0.000000 0.000000 7455.0 0.322997 0.007769 0.322997 0.000000 0.000000 7460.0 0.319360 0.005670 0.319360 0.000000 0.000000 7465.0 0.320017 0.007407 0.320017 0.000000 0.000000 7470.0 0.316073 0.004498 0.316073 0.000000 0.000000 7475.0 0.317172 0.006649 0.317172 0.000000 0.000000 7480.0 0.316454 0.007563 0.316454 0.000000 0.000000 7485.0 0.314990 0.007273 0.314990 0.000000 0.000000 7490.0 0.313728 0.006303 0.313728 0.000000 0.000000 7495.0 0.313354 0.006374 0.313354 0.000000 0.000000 7500.0 0.313290 0.007032 0.313290 0.000000 0.000000 7505.0 0.311540 0.005753 0.311540 0.000000 0.000000 7510.0 0.311390 0.006385 0.311390 0.000000 0.000000 7515.0 0.311546 0.006905 0.311546 0.000000 0.000000 7520.0 0.309484 0.004610 0.309484 0.000000 0.000000 7525.0 0.309898 0.006613 0.309898 0.000000 0.000000 7530.0 0.307433 0.005695 0.307433 0.000000 0.000000 7535.0 0.306397 0.006014 0.306397 0.000000 0.000000 7540.0 0.305547 0.007152 0.305547 0.000000 0.000000 7545.0 0.305379 0.007549 0.305379 0.000000 0.000000 7550.0 0.305224 0.007542 0.305224 0.000000 0.000000 7555.0 0.304342 0.007604 0.304342 0.000000 0.000000 7560.0 0.303459 0.007665 0.303459 0.000000 0.000000 7565.0 0.302577 0.007728 0.302577 0.000000 0.000000 7570.0 0.301695 0.007790 0.301695 0.000000 0.000000 7575.0 0.300813 0.007851 0.300813 0.000000 0.000000 7580.0 0.299931 0.007913 0.299931 0.000000 0.000000 7585.0 0.299048 0.007975 0.299048 0.000000 0.000000 7590.0 0.298166 0.008038 0.298166 0.000000 0.000000 7595.0 0.297284 0.008100 0.297284 0.000000 0.000000 7600.0 0.296402 0.008162 0.296402 0.000000 0.000000 7605.0 0.295520 0.008223 0.295520 0.000000 0.000000 7610.0 0.294638 0.008286 0.294638 0.000000 0.000000 7615.0 0.293755 0.008346 0.293755 0.000000 0.000000 7620.0 0.292873 0.008409 0.292873 0.000000 0.000000 7625.0 0.291991 0.008471 0.291991 0.000000 0.000000 7630.0 0.291109 0.008533 0.291109 0.000000 0.000000 7635.0 0.290227 0.008594 0.290227 0.000000 0.000000 7640.0 0.289344 0.008658 0.289344 0.000000 0.000000 7645.0 0.288462 0.008719 0.288462 0.000000 0.000000 7650.0 0.287580 0.008782 0.287580 0.000000 0.000000 7655.0 0.286698 0.008842 0.286698 0.000000 0.000000 7660.0 0.285816 0.008905 0.285816 0.000000 0.000000 7665.0 0.284934 0.008966 0.284934 0.000000 0.000000 7670.0 0.284051 0.009029 0.284051 0.000000 0.000000 7675.0 0.283169 0.009091 0.283169 0.000000 0.000000 7680.0 0.282287 0.009153 0.282287 0.000000 0.000000 7685.0 0.281405 0.009215 0.281405 0.000000 0.000000 7690.0 0.280523 0.009277 0.280523 0.000000 0.000000 7695.0 0.279641 0.009338 0.279641 0.000000 0.000000 7700.0 0.278758 0.009400 0.278758 0.000000 0.000000 7705.0 0.277876 0.009462 0.277876 0.000000 0.000000 7710.0 0.276994 0.009525 0.276994 0.000000 0.000000 7715.0 0.276112 0.009586 0.276112 0.000000 0.000000 7720.0 0.275230 0.009649 0.275230 0.000000 0.000000 7725.0 0.274347 0.009710 0.274347 0.000000 0.000000 7730.0 0.273465 0.009772 0.273465 0.000000 0.000000 7735.0 0.272181 0.009125 0.272181 0.000000 0.000000 7740.0 0.272959 0.010650 0.272959 0.000000 0.000000 7745.0 0.271578 0.009426 0.271578 0.000000 0.000000 7750.0 0.271809 0.009649 0.271809 0.000000 0.000000 7755.0 0.270888 0.009562 0.270888 0.000000 0.000000 7760.0 0.270185 0.010243 0.270185 0.000000 0.000000 7765.0 0.268911 0.010668 0.268911 0.000000 0.000000 7770.0 0.269078 0.011320 0.269078 0.000000 0.000000 7775.0 0.268858 0.011360 0.268858 0.000000 0.000000 7780.0 0.266375 0.009025 0.266375 0.000000 0.000000 7785.0 0.267075 0.010213 0.267075 0.000000 0.000000 7790.0 0.266096 0.008595 0.266096 0.000000 0.000000 7795.0 0.265302 0.007886 0.265302 0.000000 0.000000 7800.0 0.265220 0.009153 0.265220 0.000000 0.000000 7805.0 0.264219 0.008892 0.264219 0.000000 0.000000 7810.0 0.264443 0.009477 0.264443 0.000000 0.000000 7815.0 0.263114 0.008468 0.263114 0.000000 0.000000 7820.0 0.263755 0.008159 0.263755 0.000000 0.000000 7825.0 0.262594 0.008650 0.262594 0.000000 0.000000 7830.0 0.260397 0.008400 0.260397 0.000000 0.000000 7835.0 0.260995 0.010440 0.260995 0.000000 0.000000 7840.0 0.259578 0.008427 0.259578 0.000000 0.000000 7845.0 0.259895 0.009569 0.259895 0.000000 0.000000 7850.0 0.259273 0.008122 0.259273 0.000000 0.000000 7855.0 0.259581 0.008049 0.259581 0.000000 0.000000 7860.0 0.255743 0.005439 0.255743 0.000000 0.000000 7865.0 0.255601 0.007750 0.255601 0.000000 0.000000 7870.0 0.256031 0.008767 0.256031 0.000000 0.000000 7875.0 0.255135 0.009434 0.255135 0.000000 0.000000 7880.0 0.255578 0.010312 0.255578 0.000000 0.000000 7885.0 0.253327 0.008451 0.253327 0.000000 0.000000 7890.0 0.253870 0.009906 0.253870 0.000000 0.000000 7895.0 0.251718 0.009337 0.251718 0.000000 0.000000 7900.0 0.251173 0.008905 0.251173 0.000000 0.000000 7905.0 0.251794 0.010435 0.251794 0.000000 0.000000 7910.0 0.250875 0.008549 0.250875 0.000000 0.000000 7915.0 0.251042 0.007602 0.251042 0.000000 0.000000 7920.0 0.249965 0.010155 0.249965 0.000000 0.000000 7925.0 0.247702 0.010345 0.247702 0.000000 0.000000 7930.0 0.246801 0.010398 0.246801 0.000000 0.000000 7935.0 0.247876 0.011875 0.247876 0.000000 0.000000 7940.0 0.248405 0.012847 0.248405 0.000000 0.000000 7945.0 0.246258 0.010066 0.246258 0.000000 0.000000 7950.0 0.245561 0.009144 0.245561 0.000000 0.000000 7955.0 0.244195 0.009024 0.244195 0.000000 0.000000 7960.0 0.243798 0.008365 0.243798 0.000000 0.000000 7965.0 0.243944 0.008397 0.243944 0.000000 0.000000 7970.0 0.242287 0.007915 0.242287 0.000000 0.000000 7975.0 0.242953 0.009913 0.242953 0.000000 0.000000 7980.0 0.241731 0.008726 0.241731 0.000000 0.000000 7985.0 0.241785 0.010324 0.241785 0.000000 0.000000 7990.0 0.241750 0.009653 0.241750 0.000000 0.000000 7995.0 0.240342 0.007388 0.240342 0.000000 0.000000 8000.0 0.241027 0.010766 0.241027 0.000000 0.000000 8005.0 0.241871 0.010033 0.241871 0.000000 0.000000 8010.0 0.241900 0.010180 0.241900 0.000000 0.000000 8015.0 0.240962 0.009618 0.240962 0.000000 0.000000 8020.0 0.240642 0.009469 0.240642 0.000000 0.000000 8025.0 0.240320 0.009776 0.240320 0.000000 0.000000 8030.0 0.240593 0.011040 0.240593 0.000000 0.000000 8035.0 0.240312 0.011674 0.240312 0.000000 0.000000 8040.0 0.239552 0.012045 0.239552 0.000000 0.000000 8045.0 0.239511 0.012160 0.239511 0.000000 0.000000 8050.0 0.239947 0.011901 0.239947 0.000000 0.000000 8055.0 0.240919 0.010053 0.240919 0.000000 0.000000 8060.0 0.239463 0.011187 0.239463 0.000000 0.000000 8065.0 0.237723 0.011449 0.237723 0.000000 0.000000 8070.0 0.237402 0.011899 0.237402 0.000000 0.000000 8075.0 0.236708 0.011472 0.236708 0.000000 0.000000 8080.0 0.234768 0.010375 0.234768 0.000000 0.000000 8085.0 0.233695 0.010065 0.233695 0.000000 0.000000 8090.0 0.232279 0.009586 0.232279 0.000000 0.000000 8095.0 0.231395 0.009534 0.231395 0.000000 0.000000 8100.0 0.230269 0.009152 0.230269 0.000000 0.000000 8105.0 0.230517 0.009940 0.230517 0.000000 0.000000 8110.0 0.229565 0.009168 0.229565 0.000000 0.000000 8115.0 0.231601 0.011425 0.231601 0.000000 0.000000 8120.0 0.231277 0.011347 0.231277 0.000000 0.000000 8125.0 0.230447 0.011139 0.230447 0.000000 0.000000 8130.0 0.229942 0.011258 0.229942 0.000000 0.000000 8135.0 0.228734 0.010934 0.228734 0.000000 0.000000 8140.0 0.228566 0.010983 0.228566 0.000000 0.000000 8145.0 0.226896 0.010106 0.226896 0.000000 0.000000 8150.0 0.224411 0.008752 0.224411 0.000000 0.000000 8155.0 0.222395 0.007664 0.222395 0.000000 0.000000 8160.0 0.220686 0.006824 0.220686 0.000000 0.000000 8165.0 0.219779 0.006455 0.219779 0.000000 0.000000 8170.0 0.220098 0.006809 0.220098 0.000000 0.000000 8175.0 0.221577 0.008508 0.221577 0.000000 0.000000 8180.0 0.219163 0.007026 0.219163 0.000000 0.000000 8185.0 0.222950 0.010998 0.222950 0.000000 0.000000 8190.0 0.222762 0.011313 0.222762 0.000000 0.000000 8195.0 0.218269 0.007539 0.218269 0.000000 0.000000 8200.0 0.221286 0.011283 0.221286 0.000000 0.000000 8205.0 0.220235 0.011529 0.220235 0.000000 0.000000 8210.0 0.219565 0.012848 0.219565 0.000000 0.000000 8215.0 0.217241 0.011923 0.217241 0.000000 0.000000 8220.0 0.213787 0.008965 0.213787 0.000000 0.000000 8225.0 0.209685 0.004326 0.209685 0.000000 0.000000 8230.0 0.205844 0.001749 0.205844 0.000000 0.000000 8235.0 0.207665 0.002504 0.207665 0.000000 0.000000 8240.0 0.206825 0.003494 0.206825 0.000000 0.000000 8245.0 0.210995 0.005970 0.210995 0.000000 0.000000 8250.0 0.215449 0.010224 0.215449 0.000000 0.000000 8255.0 0.215159 0.010142 0.215159 0.000000 0.000000 8260.0 0.215591 0.010949 0.215591 0.000000 0.000000 8265.0 0.215324 0.011102 0.215324 0.000000 0.000000 8270.0 0.215239 0.011761 0.215239 0.000000 0.000000 8275.0 0.212327 0.009739 0.212327 0.000000 0.000000 8280.0 0.210988 0.009125 0.210988 0.000000 0.000000 8285.0 0.210217 0.008784 0.210217 0.000000 0.000000 8290.0 0.210845 0.009705 0.210845 0.000000 0.000000 8295.0 0.211434 0.010712 0.211434 0.000000 0.000000 8300.0 0.213217 0.012434 0.213217 0.000000 0.000000 8305.0 0.210894 0.011496 0.210894 0.000000 0.000000 8310.0 0.210584 0.011437 0.210584 0.000000 0.000000 8315.0 0.209950 0.011230 0.209950 0.000000 0.000000 8320.0 0.207969 0.010464 0.207969 0.000000 0.000000 8325.0 0.207987 0.010863 0.207987 0.000000 0.000000 8330.0 0.208178 0.011441 0.208178 0.000000 0.000000 8335.0 0.207687 0.011617 0.207687 0.000000 0.000000 8340.0 0.207829 0.011711 0.207829 0.000000 0.000000 8345.0 0.205305 0.010117 0.205305 0.000000 0.000000 8350.0 0.203659 0.009216 0.203659 0.000000 0.000000 8355.0 0.202000 0.008919 0.202000 0.000000 0.000000 8360.0 0.199765 0.007579 0.199765 0.000000 0.000000 8365.0 0.200374 0.008808 0.200374 0.000000 0.000000 8370.0 0.201048 0.009293 0.201048 0.000000 0.000000 8375.0 0.201847 0.009917 0.201847 0.000000 0.000000 8380.0 0.201460 0.010237 0.201460 0.000000 0.000000 8385.0 0.202817 0.011753 0.202817 0.000000 0.000000 8390.0 0.202737 0.012462 0.202737 0.000000 0.000000 8395.0 0.202338 0.012953 0.202338 0.000000 0.000000 8400.0 0.203185 0.013616 0.203185 0.000000 0.000000 8405.0 0.202719 0.013782 0.202719 0.000000 0.000000 8410.0 0.201952 0.013540 0.201952 0.000000 0.000000 8415.0 0.201639 0.012894 0.201639 0.000000 0.000000 8420.0 0.200843 0.012778 0.200843 0.000000 0.000000 8425.0 0.200921 0.012606 0.200921 0.000000 0.000000 8430.0 0.199773 0.012043 0.199773 0.000000 0.000000 8435.0 0.199466 0.012461 0.199466 0.000000 0.000000 8440.0 0.197601 0.013448 0.197601 0.000000 0.000000 8445.0 0.198129 0.012834 0.198129 0.000000 0.000000 8450.0 0.197388 0.012193 0.197388 0.000000 0.000000 8455.0 0.197881 0.012470 0.197881 0.000000 0.000000 8460.0 0.197064 0.012222 0.197064 0.000000 0.000000 8465.0 0.196437 0.011075 0.196437 0.000000 0.000000 8470.0 0.195395 0.011013 0.195395 0.000000 0.000000 8475.0 0.196480 0.012264 0.196480 0.000000 0.000000 8480.0 0.192602 0.010424 0.192602 0.000000 0.000000 8485.0 0.192566 0.010983 0.192566 0.000000 0.000000 8490.0 0.193141 0.011107 0.193141 0.000000 0.000000 8495.0 0.193749 0.012454 0.193749 0.000000 0.000000 8500.0 0.192096 0.013295 0.192096 0.000000 0.000000 8505.0 0.193033 0.013407 0.193033 0.000000 0.000000 8510.0 0.193527 0.013499 0.193527 0.000000 0.000000 8515.0 0.192745 0.013599 0.192745 0.000000 0.000000 8520.0 0.192177 0.013168 0.192177 0.000000 0.000000 8525.0 0.190905 0.012104 0.190905 0.000000 0.000000 8530.0 0.189662 0.011624 0.189662 0.000000 0.000000 8535.0 0.188396 0.009684 0.188396 0.000000 0.000000 8540.0 0.189944 0.008656 0.189944 0.000000 0.000000 8545.0 0.186328 0.009741 0.186328 0.000000 0.000000 8550.0 0.186661 0.011474 0.186661 0.000000 0.000000 8555.0 0.186961 0.011832 0.186961 0.000000 0.000000 8560.0 0.188735 0.012839 0.188735 0.000000 0.000000 8565.0 0.188059 0.012276 0.188059 0.000000 0.000000 8570.0 0.186405 0.011841 0.186405 0.000000 0.000000 8575.0 0.185071 0.010923 0.185071 0.000000 0.000000 8580.0 0.183937 0.009906 0.183937 0.000000 0.000000 8585.0 0.182835 0.009357 0.182835 0.000000 0.000000 8590.0 0.181178 0.008996 0.181178 0.000000 0.000000 8595.0 0.179652 0.009110 0.179652 0.000000 0.000000 8600.0 0.180297 0.009991 0.180297 0.000000 0.000000 8605.0 0.179407 0.009444 0.179407 0.000000 0.000000 8610.0 0.180900 0.010037 0.180900 0.000000 0.000000 8615.0 0.181318 0.010394 0.181318 0.000000 0.000000 8620.0 0.180580 0.010818 0.180580 0.000000 0.000000 8625.0 0.180669 0.010737 0.180669 0.000000 0.000000 8630.0 0.181887 0.010596 0.181887 0.000000 0.000000 8635.0 0.181324 0.010102 0.181324 0.000000 0.000000 8640.0 0.179290 0.010537 0.179290 0.000000 0.000000 8645.0 0.179985 0.011771 0.179985 0.000000 0.000000 8650.0 0.180397 0.012290 0.180397 0.000000 0.000000 8655.0 0.180075 0.013129 0.180075 0.000000 0.000000 8660.0 0.178981 0.014256 0.178981 0.000000 0.000000 8665.0 0.178442 0.015467 0.178442 0.000000 0.000000 8670.0 0.179302 0.015671 0.179302 0.000000 0.000000 8675.0 0.179921 0.015123 0.179921 0.000000 0.000000 8680.0 0.180724 0.014475 0.180724 0.000000 0.000000 8685.0 0.180926 0.013682 0.180926 0.000000 0.000000 8690.0 0.180888 0.013908 0.180888 0.000000 0.000000 8695.0 0.181117 0.013535 0.181117 0.000000 0.000000 8700.0 0.181236 0.014020 0.181236 0.000000 0.000000 8705.0 0.179983 0.013028 0.179983 0.000000 0.000000 8710.0 0.179369 0.013277 0.179369 0.000000 0.000000 8715.0 0.179049 0.013570 0.179049 0.000000 0.000000 8720.0 0.178692 0.013636 0.178692 0.000000 0.000000 8725.0 0.178569 0.014207 0.178569 0.000000 0.000000 8730.0 0.177131 0.014049 0.177131 0.000000 0.000000 8735.0 0.176025 0.013943 0.176025 0.000000 0.000000 8740.0 0.177849 0.015869 0.177849 0.000000 0.000000 8745.0 0.172060 0.015602 0.172060 0.000000 0.000000 8750.0 0.172573 0.015933 0.172573 0.000000 0.000000 8755.0 0.173268 0.015256 0.173268 0.000000 0.000000 8760.0 0.174235 0.013457 0.174235 0.000000 0.000000 8765.0 0.176183 0.012672 0.176183 0.000000 0.000000 8770.0 0.173303 0.012959 0.173303 0.000000 0.000000 8775.0 0.175029 0.013379 0.175029 0.000000 0.000000 8780.0 0.174098 0.013663 0.174098 0.000000 0.000000 8785.0 0.175342 0.015358 0.175342 0.000000 0.000000 8790.0 0.175539 0.015476 0.175539 0.000000 0.000000 8795.0 0.175036 0.015587 0.175036 0.000000 0.000000 8800.0 0.175539 0.016356 0.175539 0.000000 0.000000 8805.0 0.174575 0.016301 0.174575 0.000000 0.000000 8810.0 0.175044 0.016056 0.175044 0.000000 0.000000 8815.0 0.171914 0.015350 0.171914 0.000000 0.000000 8820.0 0.173638 0.014501 0.173638 0.000000 0.000000 8825.0 0.174389 0.013257 0.174389 0.000000 0.000000 8830.0 0.173454 0.013391 0.173454 0.000000 0.000000 8835.0 0.172716 0.014618 0.172716 0.000000 0.000000 8840.0 0.170355 0.014986 0.170355 0.000000 0.000000 8845.0 0.169421 0.014909 0.169421 0.000000 0.000000 8850.0 0.167373 0.014677 0.167373 0.000000 0.000000 8855.0 0.164249 0.014499 0.164249 0.000000 0.000000 8860.0 0.161692 0.014460 0.161692 0.000000 0.000000 8865.0 0.160584 0.013243 0.160584 0.000000 0.000000 8870.0 0.161624 0.011795 0.161624 0.000000 0.000000 8875.0 0.163316 0.011911 0.163316 0.000000 0.000000 8880.0 0.164262 0.010283 0.164262 0.000000 0.000000 8885.0 0.164287 0.008704 0.164287 0.000000 0.000000 8890.0 0.165059 0.009861 0.165059 0.000000 0.000000 8895.0 0.166174 0.012229 0.166174 0.000000 0.000000 8900.0 0.164810 0.010731 0.164810 0.000000 0.000000 8905.0 0.165830 0.011644 0.165830 0.000000 0.000000 8910.0 0.164695 0.011146 0.164695 0.000000 0.000000 8915.0 0.164141 0.010463 0.164141 0.000000 0.000000 8920.0 0.164516 0.009160 0.164516 0.000000 0.000000 8925.0 0.163699 0.011845 0.163699 0.000000 0.000000 8930.0 0.170744 0.002266 0.170744 0.000000 0.000000 8935.0 0.170748 0.003035 0.170748 0.000000 0.000000 8940.0 0.172784 0.000367 0.172784 0.000000 0.000000 8945.0 0.169521 0.001905 0.169521 0.000000 0.000000 8950.0 0.166886 0.001552 0.166886 0.000000 0.000000 8955.0 0.164368 0.000706 0.164368 0.000000 0.000000 8960.0 0.162916 0.000871 0.162916 0.000000 0.000000 8965.0 0.161392 0.001298 0.161392 0.000000 0.000000 8970.0 0.158567 0.000526 0.158567 0.000000 0.000000 8975.0 0.158966 0.000927 0.158966 0.000000 0.000000 8980.0 0.157639 0.000607 0.157639 0.000000 0.000000 8985.0 0.157217 0.001781 0.157217 0.000000 0.000000 8990.0 0.151537 0.002785 0.151537 0.000000 0.000000 8995.0 0.153548 0.000886 0.153548 0.000000 0.000000 9000.0 0.153846 0.001785 0.153846 0.000000 0.000000 9005.0 0.151076 0.001992 0.151076 0.000000 0.000000 9010.0 0.152675 0.002052 0.152675 0.000000 0.000000 9015.0 0.153207 0.004281 0.153207 0.000000 0.000000 9020.0 0.153095 0.008009 0.153095 0.000000 0.000000 9025.0 0.160205 0.004127 0.160205 0.000000 0.000000 9030.0 0.163353 0.004335 0.163353 0.000000 0.000000 9035.0 0.166849 0.002882 0.166849 0.000000 0.000000 9040.0 0.163837 0.006504 0.163837 0.000000 0.000000 9045.0 0.166058 0.001502 0.166058 0.000000 0.000000 9050.0 0.164380 0.001052 0.164380 0.000000 0.000000 9055.0 0.159692 0.000929 0.159692 0.000000 0.000000 9060.0 0.158024 0.003656 0.158024 0.000000 0.000000 9065.0 0.156377 0.004880 0.156377 0.000000 0.000000 9070.0 0.153138 0.002683 0.153138 0.000000 0.000000 9075.0 0.154081 0.003630 0.154081 0.000000 0.000000 9080.0 0.154049 0.002059 0.154049 0.000000 0.000000 9085.0 0.154110 0.000593 0.154110 0.000000 0.000000 9090.0 0.155491 0.002177 0.155491 0.000000 0.000000 9095.0 0.157237 0.002862 0.157237 0.000000 0.000000 9100.0 0.156499 0.004923 0.156499 0.000000 0.000000 9105.0 0.153257 0.007785 0.153257 0.000000 0.000000 9110.0 0.156032 0.002540 0.156032 0.000000 0.000000 9115.0 0.157460 0.001653 0.157460 0.000000 0.000000 9120.0 0.156597 0.002811 0.156597 0.000000 0.000000 9125.0 0.154987 0.001998 0.154987 0.000000 0.000000 9130.0 0.153201 0.000241 0.153201 0.000000 0.000000 9135.0 0.151501 0.001521 0.151501 0.000000 0.000000 9140.0 0.152843 0.000667 0.152843 0.000000 0.000000 9145.0 0.152430 0.001847 0.152430 0.000000 0.000000 9150.0 0.150413 0.001579 0.150413 0.000000 0.000000 9155.0 0.142405 0.005883 0.142405 0.000000 0.000000 9160.0 0.149919 0.002660 0.149919 0.000000 0.000000 9165.0 0.151111 0.002247 0.151111 0.000000 0.000000 9170.0 0.150183 0.001746 0.150183 0.000000 0.000000 9175.0 0.150280 0.004811 0.150280 0.000000 0.000000 9180.0 0.154520 0.002473 0.154520 0.000000 0.000000 9185.0 0.156525 0.001134 0.156525 0.000000 0.000000 9190.0 0.155050 0.002486 0.155050 0.000000 0.000000 9195.0 0.151963 0.005004 0.151963 0.000000 0.000000 9200.0 0.151803 0.004169 0.151803 0.000000 0.000000 9205.0 0.157339 0.002688 0.157339 0.000000 0.000000 9210.0 0.153034 0.001686 0.153034 0.000000 0.000000 9215.0 0.150143 0.004452 0.150143 0.000000 0.000000 9220.0 0.149059 0.004915 0.149059 0.000000 0.000000 9225.0 0.146587 0.006482 0.146587 0.000000 0.000000 9230.0 0.148371 0.003028 0.148371 0.000000 0.000000 9235.0 0.145322 0.004990 0.145322 0.000000 0.000000 9240.0 0.145492 0.003638 0.145492 0.000000 0.000000 9245.0 0.143807 0.004875 0.143807 0.000000 0.000000 9250.0 0.145978 0.002370 0.145978 0.000000 0.000000 9255.0 0.150806 0.002522 0.150806 0.000000 0.000000 9260.0 0.146229 0.003694 0.146229 0.000000 0.000000 9265.0 0.152681 0.001791 0.152681 0.000000 0.000000 9270.0 0.154578 0.001408 0.154578 0.000000 0.000000 9275.0 0.158911 0.002804 0.158911 0.000000 0.000000 9280.0 0.155954 0.005062 0.155954 0.000000 0.000000 9285.0 0.152147 0.014832 0.152147 0.000000 0.000000 9290.0 0.162481 0.008265 0.162481 0.000000 0.000000 9295.0 0.161985 0.011467 0.161985 0.000000 0.000000 9300.0 0.158865 0.013455 0.158865 0.000000 0.000000 9305.0 0.155643 0.010450 0.155643 0.000000 0.000000 9310.0 0.146786 0.011077 0.146786 0.000000 0.000000 9315.0 0.144053 0.005482 0.144053 0.000000 0.000000 9320.0 0.135605 0.010193 0.135605 0.000000 0.000000 9325.0 0.139732 0.006917 0.139732 0.000000 0.000000 9330.0 0.138776 0.013012 0.138776 0.000000 0.000000 9335.0 0.138055 0.019009 0.138055 0.000000 0.000000 9340.0 0.139325 0.019425 0.139325 0.000000 0.000000 9345.0 0.129382 0.026634 0.129382 0.000000 0.000000 9350.0 0.133546 0.014481 0.133546 0.000000 0.000000 9355.0 0.125537 0.015633 0.125537 0.000000 0.000000 9360.0 0.133166 0.002284 0.133166 0.000000 0.000000 9365.0 0.134508 0.001335 0.134508 0.000000 0.000000 9370.0 0.130966 0.010003 0.130966 0.000000 0.000000 9375.0 0.137493 0.009461 0.137493 0.000000 0.000000 9380.0 0.138133 0.015437 0.138133 0.000000 0.000000 9385.0 0.149437 0.007656 0.149437 0.000000 0.000000 9390.0 0.156787 0.002057 0.156787 0.000000 0.000000 9395.0 0.158040 0.000976 0.158040 0.000000 0.000000 9400.0 0.157648 0.000629 0.157648 0.000000 0.000000 9405.0 0.155486 0.002509 0.155486 0.000000 0.000000 9410.0 0.153452 0.005972 0.153452 0.000000 0.000000 9415.0 0.141510 0.001181 0.141510 0.000000 0.000000 9420.0 0.142109 0.005163 0.142109 0.000000 0.000000 9425.0 0.136779 0.003515 0.136779 0.000000 0.000000 9430.0 0.130490 0.000841 0.130490 0.000000 0.000000 9435.0 0.133261 0.003167 0.133261 0.000000 0.000000 9440.0 0.122364 0.009998 0.122364 0.000000 0.000000 9445.0 0.129898 0.004361 0.129898 0.000000 0.000000 9450.0 0.135814 0.001379 0.135814 0.000000 0.000000 9455.0 0.136588 0.003825 0.136588 0.000000 0.000000 9460.0 0.133131 0.009499 0.133131 0.000000 0.000000 9465.0 0.134634 0.007333 0.134634 0.000000 0.000000 9470.0 0.133638 0.006375 0.133638 0.000000 0.000000 9475.0 0.135530 0.001687 0.135530 0.000000 0.000000 9480.0 0.132814 0.002742 0.132814 0.000000 0.000000 9485.0 0.128335 0.007172 0.128335 0.000000 0.000000 9490.0 0.133954 0.001452 0.133954 0.000000 0.000000 9495.0 0.134717 0.001779 0.134717 0.000000 0.000000 9500.0 0.130549 0.007701 0.130549 0.000000 0.000000 9505.0 0.137317 0.001082 0.137317 0.000000 0.000000 9510.0 0.135824 0.003544 0.135824 0.000000 0.000000 9515.0 0.142490 0.002978 0.142490 0.000000 0.000000 9520.0 0.132487 0.009568 0.132487 0.000000 0.000000 9525.0 0.134534 0.009168 0.134534 0.000000 0.000000 9530.0 0.135944 0.009295 0.135944 0.000000 0.000000 9535.0 0.133391 0.012761 0.133391 0.000000 0.000000 9540.0 0.132554 0.012307 0.132554 0.000000 0.000000 9545.0 0.129896 0.011381 0.129896 0.000000 0.000000 9550.0 0.127868 0.008345 0.127868 0.000000 0.000000 9555.0 0.125606 0.005674 0.125606 0.000000 0.000000 9560.0 0.126842 0.000696 0.126842 0.000000 0.000000 9565.0 0.127225 0.000658 0.127225 0.000000 0.000000 9570.0 0.127142 0.000442 0.127142 0.000000 0.000000 9575.0 0.129306 0.000210 0.129306 0.000000 0.000000 9580.0 0.130570 0.000285 0.130570 0.000000 0.000000 9585.0 0.130259 0.000108 0.130259 0.000000 0.000000 9590.0 0.127378 0.002460 0.127378 0.000000 0.000000 9595.0 0.126884 0.001920 0.126884 0.000000 0.000000 9600.0 0.130390 0.002623 0.130390 0.000000 0.000000 9605.0 0.127749 0.000625 0.127749 0.000000 0.000000 9610.0 0.130430 0.001640 0.130430 0.000000 0.000000 9615.0 0.127319 0.002277 0.127319 0.000000 0.000000 9620.0 0.125917 0.003262 0.125917 0.000000 0.000000 9625.0 0.124712 0.002548 0.124712 0.000000 0.000000 9630.0 0.128442 0.004555 0.128442 0.000000 0.000000 9635.0 0.119889 0.002074 0.119889 0.000000 0.000000 9640.0 0.120039 0.000160 0.120039 0.000000 0.000000 9645.0 0.116627 0.003110 0.116627 0.000000 0.000000 9650.0 0.123353 0.003709 0.123353 0.000000 0.000000 9655.0 0.125512 0.004672 0.125512 0.000000 0.000000 9660.0 0.121497 0.001522 0.121497 0.000000 0.000000 9665.0 0.123762 0.000512 0.123762 0.000000 0.000000 9670.0 0.125609 0.000423 0.125609 0.000000 0.000000 9675.0 0.125228 0.000605 0.125228 0.000000 0.000000 9680.0 0.123830 0.002086 0.123830 0.000000 0.000000 9685.0 0.126057 0.001223 0.126057 0.000000 0.000000 9690.0 0.127975 0.004630 0.127975 0.000000 0.000000 9695.0 0.126356 0.004144 0.126356 0.000000 0.000000 9700.0 0.127930 0.006903 0.127930 0.000000 0.000000 9705.0 0.119464 0.002153 0.119464 0.000000 0.000000 9710.0 0.118589 0.003134 0.118589 0.000000 0.000000 9715.0 0.120682 0.000914 0.120682 0.000000 0.000000 9720.0 0.122784 0.001495 0.122784 0.000000 0.000000 9725.0 0.118097 0.003312 0.118097 0.000000 0.000000 9730.0 0.116706 0.004253 0.116706 0.000000 0.000000 9735.0 0.120789 0.000816 0.120789 0.000000 0.000000 9740.0 0.120816 0.000947 0.120816 0.000000 0.000000 9745.0 0.123249 0.003207 0.123249 0.000000 0.000000 9750.0 0.115191 0.006474 0.115191 0.000000 0.000000 9755.0 0.123822 0.002781 0.123822 0.000000 0.000000 9760.0 0.123445 0.002726 0.123445 0.000000 0.000000 9765.0 0.113378 0.007113 0.113378 0.000000 0.000000 9770.0 0.117836 0.000149 0.117836 0.000000 0.000000 9775.0 0.115103 0.001359 0.115103 0.000000 0.000000 9780.0 0.114605 0.000878 0.114605 0.000000 0.000000 9785.0 0.122121 0.007294 0.122121 0.000000 0.000000 9790.0 0.120029 0.003920 0.120029 0.000000 0.000000 9795.0 0.117535 0.000000 0.117535 0.000000 0.000000 9800.0 0.111204 0.007641 0.111204 0.000000 0.000000 9805.0 0.124660 0.007914 0.124660 0.000000 0.000000 9810.0 0.117866 0.001490 0.117866 0.000000 0.000000 9815.0 0.114331 0.001252 0.114331 0.000000 0.000000 9820.0 0.115233 0.000383 0.115233 0.000000 0.000000 9825.0 0.117246 0.002253 0.117246 0.000000 0.000000 9830.0 0.121383 0.005859 0.121383 0.000000 0.000000 9835.0 0.112666 0.004972 0.112666 0.000000 0.000000 9840.0 0.120166 0.002828 0.120166 0.000000 0.000000 9845.0 0.116572 0.000859 0.116572 0.000000 0.000000 9850.0 0.115039 0.001537 0.115039 0.000000 0.000000 9855.0 0.121421 0.006971 0.121421 0.000000 0.000000 9860.0 0.106002 0.008926 0.106002 0.000000 0.000000 9865.0 0.113945 0.000954 0.113945 0.000000 0.000000 9870.0 0.110036 0.002860 0.110036 0.000000 0.000000 9875.0 0.115981 0.003856 0.115981 0.000000 0.000000 9880.0 0.113961 0.001136 0.113961 0.000000 0.000000 9885.0 0.105816 0.008953 0.105816 0.000000 0.000000 9890.0 0.113409 0.001732 0.113409 0.000000 0.000000 9895.0 0.116386 0.000331 0.116386 0.000000 0.000000 9900.0 0.115584 0.001532 0.115584 0.000000 0.000000 9905.0 0.109543 0.008709 0.109543 0.000000 0.000000 9910.0 0.112280 0.005450 0.112280 0.000000 0.000000 9915.0 0.116639 0.000279 0.116639 0.000000 0.000000 9920.0 0.111713 0.003676 0.111713 0.000000 0.000000 9925.0 0.117233 0.004677 0.117233 0.000000 0.000000 9930.0 0.106728 0.004710 0.106728 0.000000 0.000000 9935.0 0.106886 0.002554 0.106886 0.000000 0.000000 9940.0 0.115119 0.007698 0.115119 0.000000 0.000000 9945.0 0.111738 0.003664 0.111738 0.000000 0.000000 9950.0 0.110431 0.001005 0.110431 0.000000 0.000000 9955.0 0.111192 0.000251 0.111192 0.000000 0.000000 9960.0 0.116340 0.004537 0.116340 0.000000 0.000000 9965.0 0.113457 0.000425 0.113457 0.000000 0.000000 9970.0 0.107011 0.007001 0.107011 0.000000 0.000000 9975.0 0.107764 0.005717 0.107764 0.000000 0.000000 9980.0 0.109147 0.003070 0.109147 0.000000 0.000000 9985.0 0.116317 0.006605 0.116317 0.000000 0.000000 9990.0 0.105530 0.003704 0.105530 0.000000 0.000000 9995.0 0.109625 0.002159 0.109625 0.000000 0.000000 10000.0 0.100833 0.007413 0.100833 0.000000 0.000000 10005.0 0.110216 0.002013 0.110216 0.000000 0.000000 10010.0 0.114714 0.005397 0.114714 0.000000 0.000000 10015.0 0.108846 0.002378 0.108846 0.000000 0.000000 10020.0 0.096866 0.015550 0.096866 0.000000 0.000000 10025.0 0.108580 0.000108 0.108580 0.000000 0.000000 10030.0 0.112759 0.008448 0.112759 0.000000 0.000000 10035.0 0.108607 0.008315 0.108607 0.000000 0.000000 10040.0 0.094086 0.003691 0.094086 0.000000 0.000000 10045.0 0.094736 0.000167 0.094736 0.000000 0.000000 10050.0 0.103921 0.012010 0.103921 0.000000 0.000000 10055.0 0.100110 0.007403 0.100110 0.000000 0.000000 10060.0 0.095151 0.000776 0.095151 0.000000 0.000000 10065.0 0.098813 0.001609 0.098813 0.000000 0.000000 10070.0 0.104314 0.001234 0.104314 0.000000 0.000000 10075.0 0.109975 0.000273 0.109975 0.000000 0.000000 10080.0 0.110275 0.001448 0.110275 0.000000 0.000000 10085.0 0.110192 0.000336 0.110192 0.000000 0.000000 10090.0 0.101196 0.005266 0.101196 0.000000 0.000000 10095.0 0.105043 0.004085 0.105043 0.000000 0.000000 10100.0 0.104358 0.006977 0.104358 0.000000 0.000000 10105.0 0.097210 0.000190 0.097210 0.000000 0.000000 10110.0 0.090956 0.008461 0.090956 0.000000 0.000000 10115.0 0.102539 0.002395 0.102539 0.000000 0.000000 10120.0 0.099726 0.002380 0.099726 0.000000 0.000000 10125.0 0.098282 0.004222 0.098282 0.000000 0.000000 10130.0 0.091382 0.011187 0.091382 0.000000 0.000000 10135.0 0.101177 0.000725 0.101177 0.000000 0.000000 10140.0 0.100169 0.000000 0.100169 0.000000 0.000000 10145.0 0.100773 0.000000 0.100773 0.000000 0.000000 10150.0 0.101922 0.000000 0.101922 0.000000 0.000000 10155.0 0.102974 0.000000 0.102974 0.000000 0.000000 10160.0 0.103291 0.000000 0.103291 0.000000 0.000000 10165.0 0.102456 0.000000 0.102456 0.000000 0.000000 10170.0 0.100947 0.000000 0.100947 0.000000 0.000000 10175.0 0.099469 0.000000 0.099469 0.000000 0.000000 10180.0 0.098723 0.000000 0.098723 0.000000 0.000000 10185.0 0.099195 0.000000 0.099195 0.000000 0.000000 10190.0 0.100505 0.000000 0.100505 0.000000 0.000000 10195.0 0.102054 0.000000 0.102054 0.000000 0.000000 10200.0 0.103243 0.000000 0.103243 0.000000 0.000000 10205.0 0.103641 0.000000 0.103641 0.000000 0.000000 10210.0 0.103488 0.000000 0.103488 0.000000 0.000000 10215.0 0.103189 0.000000 0.103189 0.000000 0.000000 10220.0 0.103152 0.000000 0.103152 0.000000 0.000000 10225.0 0.103662 0.000000 0.103662 0.000000 0.000000 10230.0 0.104533 0.000000 0.104533 0.000000 0.000000 10235.0 0.105459 0.000000 0.105459 0.000000 0.000000 10240.0 0.106134 0.000000 0.106134 0.000000 0.000000 10245.0 0.106311 0.000000 0.106311 0.000000 0.000000 10250.0 0.105992 0.000000 0.105992 0.000000 0.000000 10255.0 0.105239 0.000000 0.105239 0.000000 0.000000 10260.0 0.104113 0.000000 0.104113 0.000000 0.000000 10265.0 0.102706 0.000000 0.102706 0.000000 0.000000 10270.0 0.101235 0.000000 0.101235 0.000000 0.000000 10275.0 0.099948 0.000000 0.099948 0.000000 0.000000 10280.0 0.099093 0.000000 0.099093 0.000000 0.000000 10285.0 0.098822 0.000000 0.098822 0.000000 0.000000 10290.0 0.098910 0.000000 0.098910 0.000000 0.000000 10295.0 0.099036 0.000000 0.099036 0.000000 0.000000 10300.0 0.098879 0.000000 0.098879 0.000000 0.000000 10305.0 0.097938 0.000351 0.098226 0.097650 0.000000 10310.0 0.097390 0.000129 0.097287 0.097492 0.000000 10315.0 0.096857 0.000584 0.096379 0.097335 0.000000 10320.0 0.096497 0.000834 0.095817 0.097178 0.000000 10325.0 0.096429 0.000724 0.095838 0.097021 0.000000 10330.0 0.096607 0.000315 0.096351 0.096864 0.000000 10335.0 0.096947 0.000297 0.097187 0.096707 0.000000 10340.0 0.097362 0.000995 0.098173 0.096551 0.000000 10345.0 0.097753 0.001664 0.099111 0.096394 0.000000 10350.0 0.097968 0.002118 0.099697 0.096238 0.000000 10355.0 0.097839 0.002152 0.099596 0.096082 0.000000 10360.0 0.097201 0.001562 0.098476 0.095926 0.000000 10365.0 0.095980 0.000253 0.096189 0.095770 0.000000 10370.0 0.094473 0.001399 0.093331 0.095615 0.000000 10375.0 0.093072 0.002924 0.090684 0.095460 0.000000 10380.0 0.092167 0.003842 0.089030 0.095304 0.000000 10385.0 0.092042 0.003806 0.088934 0.095149 0.000000 10390.0 0.092543 0.003002 0.090092 0.094994 0.000000 10395.0 0.093411 0.001750 0.091983 0.094839 0.000000 10400.0 0.094385 0.000368 0.094085 0.094685 0.000000 10405.0 0.095229 0.000856 0.095928 0.094530 0.000000 10410.0 0.095811 0.001758 0.097246 0.094376 0.000000 10415.0 0.096022 0.002205 0.097823 0.094221 0.000000 10420.0 0.095755 0.002067 0.097442 0.094067 0.000000 10425.0 0.094982 0.001309 0.096050 0.093913 0.000000 10430.0 0.094003 0.000297 0.094247 0.093759 0.000000 10435.0 0.093199 0.000496 0.092793 0.093606 0.000000 10440.0 0.092951 0.000613 0.092450 0.093452 0.000000 10445.0 0.093488 0.000230 0.093677 0.093299 0.000000 10450.0 0.094438 0.001583 0.095730 0.093145 0.000000 10455.0 0.095276 0.002798 0.097561 0.092992 0.000000 10460.0 0.095480 0.003236 0.098122 0.092839 0.000000 10465.0 0.094698 0.002465 0.096711 0.092686 0.000000 10470.0 0.093268 0.000900 0.094002 0.092533 0.000000 10475.0 0.091696 0.000838 0.091012 0.092380 0.000000 10480.0 0.090494 0.002124 0.088760 0.092228 0.000000 10485.0 0.090040 0.002493 0.088005 0.092075 0.000000 10490.0 0.090202 0.002108 0.088481 0.091923 0.000000 10495.0 0.090717 0.001291 0.089663 0.091771 0.000000 10500.0 0.091323 0.000364 0.091026 0.091619 0.000000 10505.0 0.091798 0.000404 0.092128 0.091467 0.000000 10510.0 0.092081 0.000937 0.092846 0.091315 0.000000 10515.0 0.092153 0.001212 0.093142 0.091164 0.000000 10520.0 0.091994 0.001202 0.092976 0.091012 0.000000 10525.0 0.091611 0.000918 0.092360 0.090861 0.000000 10530.0 0.091113 0.000493 0.091516 0.090710 0.000000 10535.0 0.090638 0.000099 0.090717 0.090559 0.000000 10540.0 0.090321 0.000112 0.090234 0.090408 0.000000 10545.0 0.090252 0.000037 0.090247 0.090257 0.000000 10550.0 0.090327 0.000267 0.090548 0.090106 0.000000 10555.0 0.090396 0.000539 0.090836 0.089956 0.000000 10560.0 0.090307 0.000614 0.090808 0.089806 0.000000 10565.0 0.089965 0.000377 0.090274 0.089655 0.000000 10570.0 0.089494 0.000000 0.089483 0.089505 0.000000 10575.0 0.089077 0.000341 0.088798 0.089355 0.000000 10580.0 0.088893 0.000381 0.088581 0.089206 0.000000 10585.0 0.089062 0.000000 0.089068 0.089056 0.000000 10590.0 0.089455 0.000673 0.090004 0.088906 0.000000 10595.0 0.089882 0.001378 0.091008 0.088757 0.000000 10600.0 0.090153 0.001893 0.091699 0.088608 0.000000 10605.0 0.090124 0.002040 0.091789 0.088459 0.000000 10610.0 0.089835 0.001868 0.091360 0.088310 0.000000 10615.0 0.089372 0.001484 0.090584 0.088161 0.000000 10620.0 0.088823 0.000995 0.089634 0.088012 0.000000 10625.0 0.087863 0.000000 0.000000 0.087863 0.000000 10630.0 0.087715 0.000000 0.000000 0.087715 0.000000 10635.0 0.087567 0.000000 0.000000 0.087567 0.000000 10640.0 0.087419 0.000000 0.000000 0.087419 0.000000 10645.0 0.087271 0.000000 0.000000 0.087271 0.000000 10650.0 0.087123 0.000000 0.000000 0.087123 0.000000 10655.0 0.086975 0.000000 0.000000 0.086975 0.000000 10660.0 0.086827 0.000000 0.000000 0.086827 0.000000 10665.0 0.086680 0.000000 0.000000 0.086680 0.000000 10670.0 0.086533 0.000000 0.000000 0.086533 0.000000 10675.0 0.086386 0.000000 0.000000 0.086386 0.000000 10680.0 0.086239 0.000000 0.000000 0.086239 0.000000 10685.0 0.086092 0.000000 0.000000 0.086092 0.000000 10690.0 0.085945 0.000000 0.000000 0.085945 0.000000 10695.0 0.085798 0.000000 0.000000 0.085798 0.000000 10700.0 0.085652 0.000000 0.000000 0.085652 0.000000 10705.0 0.085506 0.000000 0.000000 0.085506 0.000000 10710.0 0.085360 0.000000 0.000000 0.085360 0.000000 10715.0 0.085214 0.000000 0.000000 0.085214 0.000000 10720.0 0.085068 0.000000 0.000000 0.085068 0.000000 10725.0 0.084922 0.000000 0.000000 0.084922 0.000000 10730.0 0.084776 0.000000 0.000000 0.084776 0.000000 10735.0 0.084631 0.000000 0.000000 0.084631 0.000000 10740.0 0.084486 0.000000 0.000000 0.084486 0.000000 10745.0 0.084341 0.000000 0.000000 0.084341 0.000000 10750.0 0.084196 0.000000 0.000000 0.084196 0.000000 10755.0 0.084051 0.000000 0.000000 0.084051 0.000000 10760.0 0.083906 0.000000 0.000000 0.083906 0.000000 10765.0 0.083761 0.000000 0.000000 0.083761 0.000000 10770.0 0.083617 0.000000 0.000000 0.083617 0.000000 10775.0 0.083473 0.000000 0.000000 0.083473 0.000000 10780.0 0.083329 0.000000 0.000000 0.083329 0.000000 10785.0 0.083185 0.000000 0.000000 0.083185 0.000000 10790.0 0.083041 0.000000 0.000000 0.083041 0.000000 10795.0 0.082897 0.000000 0.000000 0.082897 0.000000 10800.0 0.082753 0.000000 0.000000 0.082753 0.000000 10805.0 0.082610 0.000000 0.000000 0.082610 0.000000 10810.0 0.082467 0.000000 0.000000 0.082467 0.000000 10815.0 0.082324 0.000000 0.000000 0.082324 0.000000 10820.0 0.082181 0.000000 0.000000 0.082181 0.000000 10825.0 0.082038 0.000000 0.000000 0.082038 0.000000 10830.0 0.081895 0.000000 0.000000 0.081895 0.000000 10835.0 0.081753 0.000000 0.000000 0.081753 0.000000 10840.0 0.081610 0.000000 0.000000 0.081610 0.000000 10845.0 0.081468 0.000000 0.000000 0.081468 0.000000 10850.0 0.081326 0.000000 0.000000 0.081326 0.000000 10855.0 0.081184 0.000000 0.000000 0.081184 0.000000 10860.0 0.081042 0.000000 0.000000 0.081042 0.000000 10865.0 0.080901 0.000000 0.000000 0.080901 0.000000 10870.0 0.080759 0.000000 0.000000 0.080759 0.000000 10875.0 0.080618 0.000000 0.000000 0.080618 0.000000 10880.0 0.080477 0.000000 0.000000 0.080477 0.000000 10885.0 0.080336 0.000000 0.000000 0.080336 0.000000 10890.0 0.080195 0.000000 0.000000 0.080195 0.000000 10895.0 0.080054 0.000000 0.000000 0.080054 0.000000 10900.0 0.079913 0.000000 0.000000 0.079913 0.000000 10905.0 0.079773 0.000000 0.000000 0.079773 0.000000 10910.0 0.079633 0.000000 0.000000 0.079633 0.000000 10915.0 0.079493 0.000000 0.000000 0.079493 0.000000 10920.0 0.079353 0.000000 0.000000 0.079353 0.000000 10925.0 0.079213 0.000000 0.000000 0.079213 0.000000 10930.0 0.079073 0.000000 0.000000 0.079073 0.000000 10935.0 0.078934 0.000000 0.000000 0.078934 0.000000 10940.0 0.078794 0.000000 0.000000 0.078794 0.000000 10945.0 0.078655 0.000000 0.000000 0.078655 0.000000 10950.0 0.078516 0.000000 0.000000 0.078516 0.000000 10955.0 0.078377 0.000000 0.000000 0.078377 0.000000 10960.0 0.078238 0.000000 0.000000 0.078238 0.000000 10965.0 0.078100 0.000000 0.000000 0.078100 0.000000 10970.0 0.077961 0.000000 0.000000 0.077961 0.000000 10975.0 0.077823 0.000000 0.000000 0.077823 0.000000 10980.0 0.077685 0.000000 0.000000 0.077685 0.000000 10985.0 0.077547 0.000000 0.000000 0.077547 0.000000 10990.0 0.077409 0.000000 0.000000 0.077409 0.000000 10995.0 0.077271 0.000000 0.000000 0.077271 0.000000 11000.0 0.077133 0.000000 0.000000 0.077133 0.000000 11005.0 0.076996 0.000000 0.000000 0.076996 0.000000 11010.0 0.076859 0.000000 0.000000 0.076859 0.000000 11015.0 0.076722 0.000000 0.000000 0.076722 0.000000 11020.0 0.076585 0.000000 0.000000 0.076585 0.000000 11025.0 0.076448 0.000000 0.000000 0.076448 0.000000 11030.0 0.076311 0.000000 0.000000 0.076311 0.000000 11035.0 0.076175 0.000000 0.000000 0.076175 0.000000 11040.0 0.076038 0.000000 0.000000 0.076038 0.000000 11045.0 0.075902 0.000000 0.000000 0.075902 0.000000 11050.0 0.075766 0.000000 0.000000 0.075766 0.000000 11055.0 0.075630 0.000000 0.000000 0.075630 0.000000 11060.0 0.075495 0.000000 0.000000 0.075495 0.000000 11065.0 0.075359 0.000000 0.000000 0.075359 0.000000 11070.0 0.075224 0.000000 0.000000 0.075224 0.000000 11075.0 0.075088 0.000000 0.000000 0.075088 0.000000 11080.0 0.074953 0.000000 0.000000 0.074953 0.000000 11085.0 0.074818 0.000000 0.000000 0.074818 0.000000 11090.0 0.074684 0.000000 0.000000 0.074684 0.000000 11095.0 0.074549 0.000000 0.000000 0.074549 0.000000 11100.0 0.074415 0.000000 0.000000 0.074415 0.000000 11105.0 0.074280 0.000000 0.000000 0.074280 0.000000 11110.0 0.074146 0.000000 0.000000 0.074146 0.000000 11115.0 0.074012 0.000000 0.000000 0.074012 0.000000 11120.0 0.073878 0.000000 0.000000 0.073878 0.000000 11125.0 0.073745 0.000000 0.000000 0.073745 0.000000 11130.0 0.073611 0.000000 0.000000 0.073611 0.000000 11135.0 0.073478 0.000000 0.000000 0.073478 0.000000 11140.0 0.073344 0.000000 0.000000 0.073344 0.000000 11145.0 0.073211 0.000000 0.000000 0.073211 0.000000 11150.0 0.073079 0.000000 0.000000 0.073079 0.000000 11155.0 0.072946 0.000000 0.000000 0.072946 0.000000 11160.0 0.072813 0.000000 0.000000 0.072813 0.000000 11165.0 0.072681 0.000000 0.000000 0.072681 0.000000 11170.0 0.072549 0.000000 0.000000 0.072549 0.000000 11175.0 0.072416 0.000000 0.000000 0.072416 0.000000 11180.0 0.072285 0.000000 0.000000 0.072285 0.000000 11185.0 0.072153 0.000000 0.000000 0.072153 0.000000 11190.0 0.072021 0.000000 0.000000 0.072021 0.000000 11195.0 0.071890 0.000000 0.000000 0.071890 0.000000 11200.0 0.071758 0.000000 0.000000 0.071758 0.000000 11205.0 0.071627 0.000000 0.000000 0.071627 0.000000 11210.0 0.071496 0.000000 0.000000 0.071496 0.000000 11215.0 0.071365 0.000000 0.000000 0.071365 0.000000 11220.0 0.071235 0.000000 0.000000 0.071235 0.000000 11225.0 0.071104 0.000000 0.000000 0.071104 0.000000 11230.0 0.070974 0.000000 0.000000 0.070974 0.000000 11235.0 0.070844 0.000000 0.000000 0.070844 0.000000 11240.0 0.070714 0.000000 0.000000 0.070714 0.000000 11245.0 0.070584 0.000000 0.000000 0.070584 0.000000 11250.0 0.070454 0.000000 0.000000 0.070454 0.000000 11255.0 0.070325 0.000000 0.000000 0.070325 0.000000 11260.0 0.070195 0.000000 0.000000 0.070195 0.000000 11265.0 0.070066 0.000000 0.000000 0.070066 0.000000 11270.0 0.069937 0.000000 0.000000 0.069937 0.000000 11275.0 0.069808 0.000000 0.000000 0.069808 0.000000 11280.0 0.069680 0.000000 0.000000 0.069680 0.000000 11285.0 0.069551 0.000000 0.000000 0.069551 0.000000 11290.0 0.069423 0.000000 0.000000 0.069423 0.000000 11295.0 0.069294 0.000000 0.000000 0.069294 0.000000 11300.0 0.069166 0.000000 0.000000 0.069166 0.000000 11305.0 0.069038 0.000000 0.000000 0.069038 0.000000 11310.0 0.068911 0.000000 0.000000 0.068911 0.000000 11315.0 0.068783 0.000000 0.000000 0.068783 0.000000 11320.0 0.068656 0.000000 0.000000 0.068656 0.000000 11325.0 0.068528 0.000000 0.000000 0.068528 0.000000 11330.0 0.068401 0.000000 0.000000 0.068401 0.000000 11335.0 0.068275 0.000000 0.000000 0.068275 0.000000 11340.0 0.068148 0.000000 0.000000 0.068148 0.000000 11345.0 0.068021 0.000000 0.000000 0.068021 0.000000 11350.0 0.067895 0.000000 0.000000 0.067895 0.000000 11355.0 0.067769 0.000000 0.000000 0.067769 0.000000 11360.0 0.067642 0.000000 0.000000 0.067642 0.000000 11365.0 0.067517 0.000000 0.000000 0.067517 0.000000 11370.0 0.067391 0.000000 0.000000 0.067391 0.000000 11375.0 0.067265 0.000000 0.000000 0.067265 0.000000 11380.0 0.067140 0.000000 0.000000 0.067140 0.000000 11385.0 0.067014 0.000000 0.000000 0.067014 0.000000 11390.0 0.066889 0.000000 0.000000 0.066889 0.000000 11395.0 0.066764 0.000000 0.000000 0.066764 0.000000 11400.0 0.066640 0.000000 0.000000 0.066640 0.000000 11405.0 0.066515 0.000000 0.000000 0.066515 0.000000 11410.0 0.066391 0.000000 0.000000 0.066391 0.000000 11415.0 0.066266 0.000000 0.000000 0.066266 0.000000 11420.0 0.066142 0.000000 0.000000 0.066142 0.000000 11425.0 0.066018 0.000000 0.000000 0.066018 0.000000 11430.0 0.065895 0.000000 0.000000 0.065895 0.000000 11435.0 0.065771 0.000000 0.000000 0.065771 0.000000 11440.0 0.065648 0.000000 0.000000 0.065648 0.000000 11445.0 0.065524 0.000000 0.000000 0.065524 0.000000 11450.0 0.065401 0.000000 0.000000 0.065401 0.000000 11455.0 0.065278 0.000000 0.000000 0.065278 0.000000 11460.0 0.065156 0.000000 0.000000 0.065156 0.000000 11465.0 0.065033 0.000000 0.000000 0.065033 0.000000 11470.0 0.064911 0.000000 0.000000 0.064911 0.000000 11475.0 0.064789 0.000000 0.000000 0.064789 0.000000 11480.0 0.064666 0.000000 0.000000 0.064666 0.000000 11485.0 0.064545 0.000000 0.000000 0.064545 0.000000 11490.0 0.064423 0.000000 0.000000 0.064423 0.000000 11495.0 0.064301 0.000000 0.000000 0.064301 0.000000 11500.0 0.064180 0.000000 0.000000 0.064180 0.000000 11505.0 0.064059 0.000000 0.000000 0.064059 0.000000 11510.0 0.063938 0.000000 0.000000 0.063938 0.000000 11515.0 0.063817 0.000000 0.000000 0.063817 0.000000 11520.0 0.063696 0.000000 0.000000 0.063696 0.000000 11525.0 0.063576 0.000000 0.000000 0.063576 0.000000 11530.0 0.063455 0.000000 0.000000 0.063455 0.000000 11535.0 0.063335 0.000000 0.000000 0.063335 0.000000 11540.0 0.063215 0.000000 0.000000 0.063215 0.000000 11545.0 0.063095 0.000000 0.000000 0.063095 0.000000 11550.0 0.062976 0.000000 0.000000 0.062976 0.000000 11555.0 0.062856 0.000000 0.000000 0.062856 0.000000 11560.0 0.062737 0.000000 0.000000 0.062737 0.000000 11565.0 0.062618 0.000000 0.000000 0.062618 0.000000 11570.0 0.062499 0.000000 0.000000 0.062499 0.000000 11575.0 0.062380 0.000000 0.000000 0.062380 0.000000 11580.0 0.062261 0.000000 0.000000 0.062261 0.000000 11585.0 0.062143 0.000000 0.000000 0.062143 0.000000 11590.0 0.062024 0.000000 0.000000 0.062024 0.000000 11595.0 0.061906 0.000000 0.000000 0.061906 0.000000 11600.0 0.061788 0.000000 0.000000 0.061788 0.000000 11605.0 0.061671 0.000000 0.000000 0.061671 0.000000 11610.0 0.061553 0.000000 0.000000 0.061553 0.000000 11615.0 0.061436 0.000000 0.000000 0.061436 0.000000 11620.0 0.061318 0.000000 0.000000 0.061318 0.000000 11625.0 0.061201 0.000000 0.000000 0.061201 0.000000 11630.0 0.061084 0.000000 0.000000 0.061084 0.000000 11635.0 0.060968 0.000000 0.000000 0.060968 0.000000 11640.0 0.060851 0.000000 0.000000 0.060851 0.000000 11645.0 0.060735 0.000000 0.000000 0.060735 0.000000 11650.0 0.060619 0.000000 0.000000 0.060619 0.000000 11655.0 0.060503 0.000000 0.000000 0.060503 0.000000 11660.0 0.060387 0.000000 0.000000 0.060387 0.000000 11665.0 0.060271 0.000000 0.000000 0.060271 0.000000 11670.0 0.060156 0.000000 0.000000 0.060156 0.000000 11675.0 0.060040 0.000000 0.000000 0.060040 0.000000 11680.0 0.059925 0.000000 0.000000 0.059925 0.000000 11685.0 0.059810 0.000000 0.000000 0.059810 0.000000 11690.0 0.059696 0.000000 0.000000 0.059696 0.000000 11695.0 0.059581 0.000000 0.000000 0.059581 0.000000 11700.0 0.059467 0.000000 0.000000 0.059467 0.000000 11705.0 0.059352 0.000000 0.000000 0.059352 0.000000 11710.0 0.059238 0.000000 0.000000 0.059238 0.000000 11715.0 0.059124 0.000000 0.000000 0.059124 0.000000 11720.0 0.059011 0.000000 0.000000 0.059011 0.000000 11725.0 0.058897 0.000000 0.000000 0.058897 0.000000 11730.0 0.058784 0.000000 0.000000 0.058784 0.000000 11735.0 0.058671 0.000000 0.000000 0.058671 0.000000 11740.0 0.058558 0.000000 0.000000 0.058558 0.000000 11745.0 0.058445 0.000000 0.000000 0.058445 0.000000 11750.0 0.058332 0.000000 0.000000 0.058332 0.000000 11755.0 0.058220 0.000000 0.000000 0.058220 0.000000 11760.0 0.058107 0.000000 0.000000 0.058107 0.000000 11765.0 0.057995 0.000000 0.000000 0.057995 0.000000 11770.0 0.057883 0.000000 0.000000 0.057883 0.000000 11775.0 0.057772 0.000000 0.000000 0.057772 0.000000 11780.0 0.057660 0.000000 0.000000 0.057660 0.000000 11785.0 0.057549 0.000000 0.000000 0.057549 0.000000 11790.0 0.057437 0.000000 0.000000 0.057437 0.000000 11795.0 0.057326 0.000000 0.000000 0.057326 0.000000 11800.0 0.057216 0.000000 0.000000 0.057216 0.000000 11805.0 0.057105 0.000000 0.000000 0.057105 0.000000 11810.0 0.056995 0.000000 0.000000 0.056995 0.000000 11815.0 0.056884 0.000000 0.000000 0.056884 0.000000 11820.0 0.056774 0.000000 0.000000 0.056774 0.000000 11825.0 0.056664 0.000000 0.000000 0.056664 0.000000 11830.0 0.056554 0.000000 0.000000 0.056554 0.000000 11835.0 0.056445 0.000000 0.000000 0.056445 0.000000 11840.0 0.056335 0.000000 0.000000 0.056335 0.000000 11845.0 0.056226 0.000000 0.000000 0.056226 0.000000 11850.0 0.056117 0.000000 0.000000 0.056117 0.000000 11855.0 0.056008 0.000000 0.000000 0.056008 0.000000 11860.0 0.055900 0.000000 0.000000 0.055900 0.000000 11865.0 0.055791 0.000000 0.000000 0.055791 0.000000 11870.0 0.055683 0.000000 0.000000 0.055683 0.000000 11875.0 0.055575 0.000000 0.000000 0.055575 0.000000 11880.0 0.055467 0.000000 0.000000 0.055467 0.000000 11885.0 0.055359 0.000000 0.000000 0.055359 0.000000 11890.0 0.055252 0.000000 0.000000 0.055252 0.000000 11895.0 0.055144 0.000000 0.000000 0.055144 0.000000 11900.0 0.055037 0.000000 0.000000 0.055037 0.000000 11905.0 0.054930 0.000000 0.000000 0.054930 0.000000 11910.0 0.054823 0.000000 0.000000 0.054823 0.000000 11915.0 0.054717 0.000000 0.000000 0.054717 0.000000 11920.0 0.054610 0.000000 0.000000 0.054610 0.000000 11925.0 0.054504 0.000000 0.000000 0.054504 0.000000 11930.0 0.054398 0.000000 0.000000 0.054398 0.000000 11935.0 0.054292 0.000000 0.000000 0.054292 0.000000 11940.0 0.054186 0.000000 0.000000 0.054186 0.000000 11945.0 0.054081 0.000000 0.000000 0.054081 0.000000 11950.0 0.053976 0.000000 0.000000 0.053976 0.000000 11955.0 0.053870 0.000000 0.000000 0.053870 0.000000 11960.0 0.053765 0.000000 0.000000 0.053765 0.000000 11965.0 0.053661 0.000000 0.000000 0.053661 0.000000 11970.0 0.053556 0.000000 0.000000 0.053556 0.000000 11975.0 0.053452 0.000000 0.000000 0.053452 0.000000 11980.0 0.053347 0.000000 0.000000 0.053347 0.000000 11985.0 0.053243 0.000000 0.000000 0.053243 0.000000 11990.0 0.053140 0.000000 0.000000 0.053140 0.000000 11995.0 0.053036 0.000000 0.000000 0.053036 0.000000 12000.0 0.052932 0.000000 0.000000 0.052932 0.000000 12005.0 0.052829 0.000000 0.000000 0.052829 0.000000 12010.0 0.052726 0.000000 0.000000 0.052726 0.000000 12015.0 0.052623 0.000000 0.000000 0.052623 0.000000 12020.0 0.052521 0.000000 0.000000 0.052521 0.000000 12025.0 0.052418 0.000000 0.000000 0.052418 0.000000 12030.0 0.052316 0.000000 0.000000 0.052316 0.000000 12035.0 0.052214 0.000000 0.000000 0.052214 0.000000 12040.0 0.052112 0.000000 0.000000 0.052112 0.000000 12045.0 0.052010 0.000000 0.000000 0.052010 0.000000 12050.0 0.051908 0.000000 0.000000 0.051908 0.000000 12055.0 0.051807 0.000000 0.000000 0.051807 0.000000 12060.0 0.051706 0.000000 0.000000 0.051706 0.000000 12065.0 0.051605 0.000000 0.000000 0.051605 0.000000 12070.0 0.051504 0.000000 0.000000 0.051504 0.000000 12075.0 0.051403 0.000000 0.000000 0.051403 0.000000 12080.0 0.051303 0.000000 0.000000 0.051303 0.000000 12085.0 0.051203 0.000000 0.000000 0.051203 0.000000 12090.0 0.051103 0.000000 0.000000 0.051103 0.000000 12095.0 0.051003 0.000000 0.000000 0.051003 0.000000 12100.0 0.050903 0.000000 0.000000 0.050903 0.000000 12105.0 0.050804 0.000000 0.000000 0.050804 0.000000 12110.0 0.050704 0.000000 0.000000 0.050704 0.000000 12115.0 0.050605 0.000000 0.000000 0.050605 0.000000 12120.0 0.050506 0.000000 0.000000 0.050506 0.000000 12125.0 0.050408 0.000000 0.000000 0.050408 0.000000 12130.0 0.050309 0.000000 0.000000 0.050309 0.000000 12135.0 0.050211 0.000000 0.000000 0.050211 0.000000 12140.0 0.050113 0.000000 0.000000 0.050113 0.000000 12145.0 0.050015 0.000000 0.000000 0.050015 0.000000 12150.0 0.049917 0.000000 0.000000 0.049917 0.000000 12155.0 0.049819 0.000000 0.000000 0.049819 0.000000 12160.0 0.049722 0.000000 0.000000 0.049722 0.000000 12165.0 0.049625 0.000000 0.000000 0.049625 0.000000 12170.0 0.049528 0.000000 0.000000 0.049528 0.000000 12175.0 0.049431 0.000000 0.000000 0.049431 0.000000 12180.0 0.049334 0.000000 0.000000 0.049334 0.000000 12185.0 0.049238 0.000000 0.000000 0.049238 0.000000 12190.0 0.049142 0.000000 0.000000 0.049142 0.000000 12195.0 0.049046 0.000000 0.000000 0.049046 0.000000 12200.0 0.048950 0.000000 0.000000 0.048950 0.000000 12205.0 0.048854 0.000000 0.000000 0.048854 0.000000 12210.0 0.048759 0.000000 0.000000 0.048759 0.000000 12215.0 0.048664 0.000000 0.000000 0.048664 0.000000 12220.0 0.048569 0.000000 0.000000 0.048569 0.000000 12225.0 0.048474 0.000000 0.000000 0.048474 0.000000 12230.0 0.048379 0.000000 0.000000 0.048379 0.000000 12235.0 0.048285 0.000000 0.000000 0.048285 0.000000 12240.0 0.048191 0.000000 0.000000 0.048191 0.000000 12245.0 0.048097 0.000000 0.000000 0.048097 0.000000 12250.0 0.048003 0.000000 0.000000 0.048003 0.000000 12255.0 0.047909 0.000000 0.000000 0.047909 0.000000 12260.0 0.047816 0.000000 0.000000 0.047816 0.000000 12265.0 0.047722 0.000000 0.000000 0.047722 0.000000 12270.0 0.047629 0.000000 0.000000 0.047629 0.000000 12275.0 0.047536 0.000000 0.000000 0.047536 0.000000 12280.0 0.047444 0.000000 0.000000 0.047444 0.000000 12285.0 0.047351 0.000000 0.000000 0.047351 0.000000 12290.0 0.047259 0.000000 0.000000 0.047259 0.000000 12295.0 0.047167 0.000000 0.000000 0.047167 0.000000 12300.0 0.047075 0.000000 0.000000 0.047075 0.000000 12305.0 0.046983 0.000000 0.000000 0.046983 0.000000 12310.0 0.046891 0.000000 0.000000 0.046891 0.000000 12315.0 0.046800 0.000000 0.000000 0.046800 0.000000 12320.0 0.046709 0.000000 0.000000 0.046709 0.000000 12325.0 0.046618 0.000000 0.000000 0.046618 0.000000 12330.0 0.046527 0.000000 0.000000 0.046527 0.000000 12335.0 0.046437 0.000000 0.000000 0.046437 0.000000 12340.0 0.046346 0.000000 0.000000 0.046346 0.000000 12345.0 0.046256 0.000000 0.000000 0.046256 0.000000 12350.0 0.046166 0.000000 0.000000 0.046166 0.000000 12355.0 0.046076 0.000000 0.000000 0.046076 0.000000 12360.0 0.045986 0.000000 0.000000 0.045986 0.000000 12365.0 0.045897 0.000000 0.000000 0.045897 0.000000 12370.0 0.045808 0.000000 0.000000 0.045808 0.000000 12375.0 0.045718 0.000000 0.000000 0.045718 0.000000 12380.0 0.045630 0.000000 0.000000 0.045630 0.000000 12385.0 0.045541 0.000000 0.000000 0.045541 0.000000 12390.0 0.045452 0.000000 0.000000 0.045452 0.000000 12395.0 0.045364 0.000000 0.000000 0.045364 0.000000 12400.0 0.045276 0.000000 0.000000 0.045276 0.000000 12405.0 0.045188 0.000000 0.000000 0.045188 0.000000 12410.0 0.045100 0.000000 0.000000 0.045100 0.000000 12415.0 0.045012 0.000000 0.000000 0.045012 0.000000 12420.0 0.044925 0.000000 0.000000 0.044925 0.000000 12425.0 0.044838 0.000000 0.000000 0.044838 0.000000 12430.0 0.044751 0.000000 0.000000 0.044751 0.000000 12435.0 0.044664 0.000000 0.000000 0.044664 0.000000 12440.0 0.044577 0.000000 0.000000 0.044577 0.000000 12445.0 0.044491 0.000000 0.000000 0.044491 0.000000 12450.0 0.044404 0.000000 0.000000 0.044404 0.000000 12455.0 0.044318 0.000000 0.000000 0.044318 0.000000 12460.0 0.044232 0.000000 0.000000 0.044232 0.000000 12465.0 0.044147 0.000000 0.000000 0.044147 0.000000 12470.0 0.044061 0.000000 0.000000 0.044061 0.000000 12475.0 0.043976 0.000000 0.000000 0.043976 0.000000 12480.0 0.043891 0.000000 0.000000 0.043891 0.000000 12485.0 0.043806 0.000000 0.000000 0.043806 0.000000 12490.0 0.043721 0.000000 0.000000 0.043721 0.000000 12495.0 0.043636 0.000000 0.000000 0.043636 0.000000 12500.0 0.043552 0.000000 0.000000 0.043552 0.000000 12505.0 0.043467 0.000000 0.000000 0.043467 0.000000 12510.0 0.043383 0.000000 0.000000 0.043383 0.000000 12515.0 0.043299 0.000000 0.000000 0.043299 0.000000 12520.0 0.043215 0.000000 0.000000 0.043215 0.000000 12525.0 0.043132 0.000000 0.000000 0.043132 0.000000 12530.0 0.043049 0.000000 0.000000 0.043049 0.000000 12535.0 0.042965 0.000000 0.000000 0.042965 0.000000 12540.0 0.042882 0.000000 0.000000 0.042882 0.000000 12545.0 0.042799 0.000000 0.000000 0.042799 0.000000 12550.0 0.042717 0.000000 0.000000 0.042717 0.000000 12555.0 0.042634 0.000000 0.000000 0.042634 0.000000 12560.0 0.042552 0.000000 0.000000 0.042552 0.000000 12565.0 0.042470 0.000000 0.000000 0.042470 0.000000 12570.0 0.042388 0.000000 0.000000 0.042388 0.000000 12575.0 0.042306 0.000000 0.000000 0.042306 0.000000 12580.0 0.042225 0.000000 0.000000 0.042225 0.000000 12585.0 0.042143 0.000000 0.000000 0.042143 0.000000 12590.0 0.042062 0.000000 0.000000 0.042062 0.000000 12595.0 0.041981 0.000000 0.000000 0.041981 0.000000 12600.0 0.041900 0.000000 0.000000 0.041900 0.000000 12605.0 0.041819 0.000000 0.000000 0.041819 0.000000 12610.0 0.041739 0.000000 0.000000 0.041739 0.000000 12615.0 0.041658 0.000000 0.000000 0.041658 0.000000 12620.0 0.041578 0.000000 0.000000 0.041578 0.000000 12625.0 0.041498 0.000000 0.000000 0.041498 0.000000 12630.0 0.041419 0.000000 0.000000 0.041419 0.000000 12635.0 0.041339 0.000000 0.000000 0.041339 0.000000 12640.0 0.041259 0.000000 0.000000 0.041259 0.000000 12645.0 0.041180 0.000000 0.000000 0.041180 0.000000 12650.0 0.041101 0.000000 0.000000 0.041101 0.000000 12655.0 0.041022 0.000000 0.000000 0.041022 0.000000 12660.0 0.040943 0.000000 0.000000 0.040943 0.000000 12665.0 0.040865 0.000000 0.000000 0.040865 0.000000 12670.0 0.040786 0.000000 0.000000 0.040786 0.000000 12675.0 0.040708 0.000000 0.000000 0.040708 0.000000 12680.0 0.040630 0.000000 0.000000 0.040630 0.000000 12685.0 0.040552 0.000000 0.000000 0.040552 0.000000 12690.0 0.040474 0.000000 0.000000 0.040474 0.000000 12695.0 0.040397 0.000000 0.000000 0.040397 0.000000 12700.0 0.040319 0.000000 0.000000 0.040319 0.000000 12705.0 0.040242 0.000000 0.000000 0.040242 0.000000 12710.0 0.040165 0.000000 0.000000 0.040165 0.000000 12715.0 0.040088 0.000000 0.000000 0.040088 0.000000 12720.0 0.040012 0.000000 0.000000 0.040012 0.000000 12725.0 0.039935 0.000000 0.000000 0.039935 0.000000 12730.0 0.039859 0.000000 0.000000 0.039859 0.000000 12735.0 0.039783 0.000000 0.000000 0.039783 0.000000 12740.0 0.039707 0.000000 0.000000 0.039707 0.000000 12745.0 0.039631 0.000000 0.000000 0.039631 0.000000 12750.0 0.039555 0.000000 0.000000 0.039555 0.000000 12755.0 0.039480 0.000000 0.000000 0.039480 0.000000 12760.0 0.039404 0.000000 0.000000 0.039404 0.000000 12765.0 0.039329 0.000000 0.000000 0.039329 0.000000 12770.0 0.039254 0.000000 0.000000 0.039254 0.000000 12775.0 0.039180 0.000000 0.000000 0.039180 0.000000 12780.0 0.039105 0.000000 0.000000 0.039105 0.000000 12785.0 0.039030 0.000000 0.000000 0.039030 0.000000 12790.0 0.038956 0.000000 0.000000 0.038956 0.000000 12795.0 0.038882 0.000000 0.000000 0.038882 0.000000 12800.0 0.038808 0.000000 0.000000 0.038808 0.000000 12805.0 0.038734 0.000000 0.000000 0.038734 0.000000 12810.0 0.038661 0.000000 0.000000 0.038661 0.000000 12815.0 0.038587 0.000000 0.000000 0.038587 0.000000 12820.0 0.038514 0.000000 0.000000 0.038514 0.000000 12825.0 0.038441 0.000000 0.000000 0.038441 0.000000 12830.0 0.038368 0.000000 0.000000 0.038368 0.000000 12835.0 0.038295 0.000000 0.000000 0.038295 0.000000 12840.0 0.038222 0.000000 0.000000 0.038222 0.000000 12845.0 0.038150 0.000000 0.000000 0.038150 0.000000 12850.0 0.038078 0.000000 0.000000 0.038078 0.000000 12855.0 0.038006 0.000000 0.000000 0.038006 0.000000 12860.0 0.037934 0.000000 0.000000 0.037934 0.000000 12865.0 0.037862 0.000000 0.000000 0.037862 0.000000 12870.0 0.037790 0.000000 0.000000 0.037790 0.000000 12875.0 0.037719 0.000000 0.000000 0.037719 0.000000 12880.0 0.037647 0.000000 0.000000 0.037647 0.000000 12885.0 0.037576 0.000000 0.000000 0.037576 0.000000 12890.0 0.037505 0.000000 0.000000 0.037505 0.000000 12895.0 0.037434 0.000000 0.000000 0.037434 0.000000 12900.0 0.037364 0.000000 0.000000 0.037364 0.000000 12905.0 0.037293 0.000000 0.000000 0.037293 0.000000 12910.0 0.037223 0.000000 0.000000 0.037223 0.000000 12915.0 0.037153 0.000000 0.000000 0.037153 0.000000 12920.0 0.037083 0.000000 0.000000 0.037083 0.000000 12925.0 0.037013 0.000000 0.000000 0.037013 0.000000 12930.0 0.036943 0.000000 0.000000 0.036943 0.000000 12935.0 0.036874 0.000000 0.000000 0.036874 0.000000 12940.0 0.036805 0.000000 0.000000 0.036805 0.000000 12945.0 0.036735 0.000000 0.000000 0.036735 0.000000 12950.0 0.036666 0.000000 0.000000 0.036666 0.000000 12955.0 0.036598 0.000000 0.000000 0.036598 0.000000 12960.0 0.036529 0.000000 0.000000 0.036529 0.000000 12965.0 0.036460 0.000000 0.000000 0.036460 0.000000 12970.0 0.036392 0.000000 0.000000 0.036392 0.000000 12975.0 0.036324 0.000000 0.000000 0.036324 0.000000 12980.0 0.036256 0.000000 0.000000 0.036256 0.000000 12985.0 0.036188 0.000000 0.000000 0.036188 0.000000 12990.0 0.036120 0.000000 0.000000 0.036120 0.000000 12995.0 0.036052 0.000000 0.000000 0.036052 0.000000 13000.0 0.035985 0.000000 0.000000 0.035985 0.000000 13005.0 0.035918 0.000000 0.000000 0.035918 0.000000 13010.0 0.035851 0.000000 0.000000 0.035851 0.000000 13015.0 0.035784 0.000000 0.000000 0.035784 0.000000 13020.0 0.035717 0.000000 0.000000 0.035717 0.000000 13025.0 0.035650 0.000000 0.000000 0.035650 0.000000 13030.0 0.035584 0.000000 0.000000 0.035584 0.000000 13035.0 0.035518 0.000000 0.000000 0.035518 0.000000 13040.0 0.035451 0.000000 0.000000 0.035451 0.000000 13045.0 0.035386 0.000000 0.000000 0.035386 0.000000 13050.0 0.035320 0.000000 0.000000 0.035320 0.000000 13055.0 0.035254 0.000000 0.000000 0.035254 0.000000 13060.0 0.035188 0.000000 0.000000 0.035188 0.000000 13065.0 0.035123 0.000000 0.000000 0.035123 0.000000 13070.0 0.035058 0.000000 0.000000 0.035058 0.000000 13075.0 0.034993 0.000000 0.000000 0.034993 0.000000 13080.0 0.034928 0.000000 0.000000 0.034928 0.000000 13085.0 0.034863 0.000000 0.000000 0.034863 0.000000 13090.0 0.034799 0.000000 0.000000 0.034799 0.000000 13095.0 0.034734 0.000000 0.000000 0.034734 0.000000 13100.0 0.034670 0.000000 0.000000 0.034670 0.000000 13105.0 0.034606 0.000000 0.000000 0.034606 0.000000 13110.0 0.034542 0.000000 0.000000 0.034542 0.000000 13115.0 0.034478 0.000000 0.000000 0.034478 0.000000 13120.0 0.034414 0.000000 0.000000 0.034414 0.000000 13125.0 0.034351 0.000000 0.000000 0.034351 0.000000 13130.0 0.034288 0.000000 0.000000 0.034288 0.000000 13135.0 0.034224 0.000000 0.000000 0.034224 0.000000 13140.0 0.034161 0.000000 0.000000 0.034161 0.000000 13145.0 0.034098 0.000000 0.000000 0.034098 0.000000 13150.0 0.034036 0.000000 0.000000 0.034036 0.000000 13155.0 0.033973 0.000000 0.000000 0.033973 0.000000 13160.0 0.033911 0.000000 0.000000 0.033911 0.000000 13165.0 0.033848 0.000000 0.000000 0.033848 0.000000 13170.0 0.033786 0.000000 0.000000 0.033786 0.000000 13175.0 0.033724 0.000000 0.000000 0.033724 0.000000 13180.0 0.033662 0.000000 0.000000 0.033662 0.000000 13185.0 0.033601 0.000000 0.000000 0.033601 0.000000 13190.0 0.033539 0.000000 0.000000 0.033539 0.000000 13195.0 0.033478 0.000000 0.000000 0.033478 0.000000 13200.0 0.033417 0.000000 0.000000 0.033417 0.000000 13205.0 0.033355 0.000000 0.000000 0.033355 0.000000 13210.0 0.033295 0.000000 0.000000 0.033295 0.000000 13215.0 0.033234 0.000000 0.000000 0.033234 0.000000 13220.0 0.033173 0.000000 0.000000 0.033173 0.000000 13225.0 0.033113 0.000000 0.000000 0.033113 0.000000 13230.0 0.033052 0.000000 0.000000 0.033052 0.000000 13235.0 0.032992 0.000000 0.000000 0.032992 0.000000 13240.0 0.032932 0.000000 0.000000 0.032932 0.000000 13245.0 0.032872 0.000000 0.000000 0.032872 0.000000 13250.0 0.032812 0.000000 0.000000 0.032812 0.000000 13255.0 0.032753 0.000000 0.000000 0.032753 0.000000 13260.0 0.032693 0.000000 0.000000 0.032693 0.000000 13265.0 0.032634 0.000000 0.000000 0.032634 0.000000 13270.0 0.032575 0.000000 0.000000 0.032575 0.000000 13275.0 0.032516 0.000000 0.000000 0.032516 0.000000 13280.0 0.032457 0.000000 0.000000 0.032457 0.000000 13285.0 0.032398 0.000000 0.000000 0.032398 0.000000 13290.0 0.032340 0.000000 0.000000 0.032340 0.000000 13295.0 0.032281 0.000000 0.000000 0.032281 0.000000 13300.0 0.032223 0.000000 0.000000 0.032223 0.000000 13305.0 0.032165 0.000000 0.000000 0.032165 0.000000 13310.0 0.032107 0.000000 0.000000 0.032107 0.000000 13315.0 0.032049 0.000000 0.000000 0.032049 0.000000 13320.0 0.031991 0.000000 0.000000 0.031991 0.000000 13325.0 0.031934 0.000000 0.000000 0.031934 0.000000 13330.0 0.031876 0.000000 0.000000 0.031876 0.000000 13335.0 0.031819 0.000000 0.000000 0.031819 0.000000 13340.0 0.031762 0.000000 0.000000 0.031762 0.000000 13345.0 0.031705 0.000000 0.000000 0.031705 0.000000 13350.0 0.031648 0.000000 0.000000 0.031648 0.000000 13355.0 0.031592 0.000000 0.000000 0.031592 0.000000 13360.0 0.031535 0.000000 0.000000 0.031535 0.000000 13365.0 0.031479 0.000000 0.000000 0.031479 0.000000 13370.0 0.031422 0.000000 0.000000 0.031422 0.000000 13375.0 0.031366 0.000000 0.000000 0.031366 0.000000 13380.0 0.031310 0.000000 0.000000 0.031310 0.000000 13385.0 0.031254 0.000000 0.000000 0.031254 0.000000 13390.0 0.031199 0.000000 0.000000 0.031199 0.000000 13395.0 0.031143 0.000000 0.000000 0.031143 0.000000 13400.0 0.031088 0.000000 0.000000 0.031088 0.000000 13405.0 0.031032 0.000000 0.000000 0.031032 0.000000 13410.0 0.030977 0.000000 0.000000 0.030977 0.000000 13415.0 0.030922 0.000000 0.000000 0.030922 0.000000 13420.0 0.030867 0.000000 0.000000 0.030867 0.000000 13425.0 0.030813 0.000000 0.000000 0.030813 0.000000 13430.0 0.030758 0.000000 0.000000 0.030758 0.000000 13435.0 0.030704 0.000000 0.000000 0.030704 0.000000 13440.0 0.030649 0.000000 0.000000 0.030649 0.000000 13445.0 0.030595 0.000000 0.000000 0.030595 0.000000 13450.0 0.030541 0.000000 0.000000 0.030541 0.000000 13455.0 0.030487 0.000000 0.000000 0.030487 0.000000 13460.0 0.030434 0.000000 0.000000 0.030434 0.000000 13465.0 0.030380 0.000000 0.000000 0.030380 0.000000 13470.0 0.030326 0.000000 0.000000 0.030326 0.000000 13475.0 0.030273 0.000000 0.000000 0.030273 0.000000 13480.0 0.030220 0.000000 0.000000 0.030220 0.000000 13485.0 0.030167 0.000000 0.000000 0.030167 0.000000 13490.0 0.030114 0.000000 0.000000 0.030114 0.000000 13495.0 0.030061 0.000000 0.000000 0.030061 0.000000 13500.0 0.030009 0.000000 0.000000 0.030009 0.000000 13505.0 0.029956 0.000000 0.000000 0.029956 0.000000 13510.0 0.029904 0.000000 0.000000 0.029904 0.000000 13515.0 0.029851 0.000000 0.000000 0.029851 0.000000 13520.0 0.029799 0.000000 0.000000 0.029799 0.000000 13525.0 0.029747 0.000000 0.000000 0.029747 0.000000 13530.0 0.029695 0.000000 0.000000 0.029695 0.000000 13535.0 0.029644 0.000000 0.000000 0.029644 0.000000 13540.0 0.029592 0.000000 0.000000 0.029592 0.000000 13545.0 0.029541 0.000000 0.000000 0.029541 0.000000 13550.0 0.029489 0.000000 0.000000 0.029489 0.000000 13555.0 0.029438 0.000000 0.000000 0.029438 0.000000 13560.0 0.029387 0.000000 0.000000 0.029387 0.000000 13565.0 0.029336 0.000000 0.000000 0.029336 0.000000 13570.0 0.029286 0.000000 0.000000 0.029286 0.000000 13575.0 0.029235 0.000000 0.000000 0.029235 0.000000 13580.0 0.029184 0.000000 0.000000 0.029184 0.000000 13585.0 0.029134 0.000000 0.000000 0.029134 0.000000 13590.0 0.029084 0.000000 0.000000 0.029084 0.000000 13595.0 0.029034 0.000000 0.000000 0.029034 0.000000 13600.0 0.028984 0.000000 0.000000 0.028984 0.000000 13605.0 0.028934 0.000000 0.000000 0.028934 0.000000 13610.0 0.028884 0.000000 0.000000 0.028884 0.000000 13615.0 0.028835 0.000000 0.000000 0.028835 0.000000 13620.0 0.028785 0.000000 0.000000 0.028785 0.000000 13625.0 0.028736 0.000000 0.000000 0.028736 0.000000 13630.0 0.028687 0.000000 0.000000 0.028687 0.000000 13635.0 0.028638 0.000000 0.000000 0.028638 0.000000 13640.0 0.028589 0.000000 0.000000 0.028589 0.000000 13645.0 0.028540 0.000000 0.000000 0.028540 0.000000 13650.0 0.028491 0.000000 0.000000 0.028491 0.000000 13655.0 0.028443 0.000000 0.000000 0.028443 0.000000 13660.0 0.028394 0.000000 0.000000 0.028394 0.000000 13665.0 0.028346 0.000000 0.000000 0.028346 0.000000 13670.0 0.028298 0.000000 0.000000 0.028298 0.000000 13675.0 0.028250 0.000000 0.000000 0.028250 0.000000 13680.0 0.028202 0.000000 0.000000 0.028202 0.000000 13685.0 0.028154 0.000000 0.000000 0.028154 0.000000 13690.0 0.028107 0.000000 0.000000 0.028107 0.000000 13695.0 0.028059 0.000000 0.000000 0.028059 0.000000 13700.0 0.028012 0.000000 0.000000 0.028012 0.000000 13705.0 0.027964 0.000000 0.000000 0.027964 0.000000 13710.0 0.027917 0.000000 0.000000 0.027917 0.000000 13715.0 0.027870 0.000000 0.000000 0.027870 0.000000 13720.0 0.027823 0.000000 0.000000 0.027823 0.000000 13725.0 0.027777 0.000000 0.000000 0.027777 0.000000 13730.0 0.027730 0.000000 0.000000 0.027730 0.000000 13735.0 0.027683 0.000000 0.000000 0.027683 0.000000 13740.0 0.027637 0.000000 0.000000 0.027637 0.000000 13745.0 0.027591 0.000000 0.000000 0.027591 0.000000 13750.0 0.027545 0.000000 0.000000 0.027545 0.000000 13755.0 0.027499 0.000000 0.000000 0.027499 0.000000 13760.0 0.027453 0.000000 0.000000 0.027453 0.000000 13765.0 0.027407 0.000000 0.000000 0.027407 0.000000 13770.0 0.027361 0.000000 0.000000 0.027361 0.000000 13775.0 0.027316 0.000000 0.000000 0.027316 0.000000 13780.0 0.027271 0.000000 0.000000 0.027271 0.000000 13785.0 0.027225 0.000000 0.000000 0.027225 0.000000 13790.0 0.027180 0.000000 0.000000 0.027180 0.000000 13795.0 0.027135 0.000000 0.000000 0.027135 0.000000 13800.0 0.027090 0.000000 0.000000 0.027090 0.000000 13805.0 0.027045 0.000000 0.000000 0.027045 0.000000 13810.0 0.027001 0.000000 0.000000 0.027001 0.000000 13815.0 0.026956 0.000000 0.000000 0.026956 0.000000 13820.0 0.026912 0.000000 0.000000 0.026912 0.000000 13825.0 0.026868 0.000000 0.000000 0.026868 0.000000 13830.0 0.026823 0.000000 0.000000 0.026823 0.000000 13835.0 0.026779 0.000000 0.000000 0.026779 0.000000 13840.0 0.026735 0.000000 0.000000 0.026735 0.000000 13845.0 0.026692 0.000000 0.000000 0.026692 0.000000 13850.0 0.026648 0.000000 0.000000 0.026648 0.000000 13855.0 0.026604 0.000000 0.000000 0.026604 0.000000 13860.0 0.026561 0.000000 0.000000 0.026561 0.000000 13865.0 0.026518 0.000000 0.000000 0.026518 0.000000 13870.0 0.026474 0.000000 0.000000 0.026474 0.000000 13875.0 0.026431 0.000000 0.000000 0.026431 0.000000 13880.0 0.026388 0.000000 0.000000 0.026388 0.000000 13885.0 0.026346 0.000000 0.000000 0.026346 0.000000 13890.0 0.026303 0.000000 0.000000 0.026303 0.000000 13895.0 0.026260 0.000000 0.000000 0.026260 0.000000 13900.0 0.026218 0.000000 0.000000 0.026218 0.000000 13905.0 0.026175 0.000000 0.000000 0.026175 0.000000 13910.0 0.026133 0.000000 0.000000 0.026133 0.000000 13915.0 0.026091 0.000000 0.000000 0.026091 0.000000 13920.0 0.026049 0.000000 0.000000 0.026049 0.000000 13925.0 0.026007 0.000000 0.000000 0.026007 0.000000 13930.0 0.025965 0.000000 0.000000 0.025965 0.000000 13935.0 0.025924 0.000000 0.000000 0.025924 0.000000 13940.0 0.025882 0.000000 0.000000 0.025882 0.000000 13945.0 0.025841 0.000000 0.000000 0.025841 0.000000 13950.0 0.025799 0.000000 0.000000 0.025799 0.000000 13955.0 0.025758 0.000000 0.000000 0.025758 0.000000 13960.0 0.025717 0.000000 0.000000 0.025717 0.000000 13965.0 0.025676 0.000000 0.000000 0.025676 0.000000 13970.0 0.025635 0.000000 0.000000 0.025635 0.000000 13975.0 0.025594 0.000000 0.000000 0.025594 0.000000 13980.0 0.025554 0.000000 0.000000 0.025554 0.000000 13985.0 0.025513 0.000000 0.000000 0.025513 0.000000 13990.0 0.025473 0.000000 0.000000 0.025473 0.000000 13995.0 0.025432 0.000000 0.000000 0.025432 0.000000 14000.0 0.025392 0.000000 0.000000 0.025392 0.000000 14005.0 0.025352 0.000000 0.000000 0.025352 0.000000 14010.0 0.025312 0.000000 0.000000 0.025312 0.000000 14015.0 0.025272 0.000000 0.000000 0.025272 0.000000 14020.0 0.025233 0.000000 0.000000 0.025233 0.000000 14025.0 0.025193 0.000000 0.000000 0.025193 0.000000 14030.0 0.025153 0.000000 0.000000 0.025153 0.000000 14035.0 0.025114 0.000000 0.000000 0.025114 0.000000 14040.0 0.025075 0.000000 0.000000 0.025075 0.000000 14045.0 0.025036 0.000000 0.000000 0.025036 0.000000 14050.0 0.024997 0.000000 0.000000 0.024997 0.000000 14055.0 0.024958 0.000000 0.000000 0.024958 0.000000 14060.0 0.024919 0.000000 0.000000 0.024919 0.000000 14065.0 0.024880 0.000000 0.000000 0.024880 0.000000 14070.0 0.024841 0.000000 0.000000 0.024841 0.000000 14075.0 0.024803 0.000000 0.000000 0.024803 0.000000 14080.0 0.024765 0.000000 0.000000 0.024765 0.000000 14085.0 0.024726 0.000000 0.000000 0.024726 0.000000 14090.0 0.024688 0.000000 0.000000 0.024688 0.000000 14095.0 0.024650 0.000000 0.000000 0.024650 0.000000 14100.0 0.024612 0.000000 0.000000 0.024612 0.000000 14105.0 0.024574 0.000000 0.000000 0.024574 0.000000 14110.0 0.024536 0.000000 0.000000 0.024536 0.000000 14115.0 0.024499 0.000000 0.000000 0.024499 0.000000 14120.0 0.024461 0.000000 0.000000 0.024461 0.000000 14125.0 0.024424 0.000000 0.000000 0.024424 0.000000 14130.0 0.024386 0.000000 0.000000 0.024386 0.000000 14135.0 0.024349 0.000000 0.000000 0.024349 0.000000 14140.0 0.024312 0.000000 0.000000 0.024312 0.000000 14145.0 0.024275 0.000000 0.000000 0.024275 0.000000 14150.0 0.024238 0.000000 0.000000 0.024238 0.000000 14155.0 0.024201 0.000000 0.000000 0.024201 0.000000 14160.0 0.024165 0.000000 0.000000 0.024165 0.000000 14165.0 0.024128 0.000000 0.000000 0.024128 0.000000 14170.0 0.024092 0.000000 0.000000 0.024092 0.000000 14175.0 0.024055 0.000000 0.000000 0.024055 0.000000 14180.0 0.024019 0.000000 0.000000 0.024019 0.000000 14185.0 0.023983 0.000000 0.000000 0.023983 0.000000 14190.0 0.023947 0.000000 0.000000 0.023947 0.000000 14195.0 0.023911 0.000000 0.000000 0.023911 0.000000 14200.0 0.023875 0.000000 0.000000 0.023875 0.000000 14205.0 0.023839 0.000000 0.000000 0.023839 0.000000 14210.0 0.023804 0.000000 0.000000 0.023804 0.000000 14215.0 0.023768 0.000000 0.000000 0.023768 0.000000 14220.0 0.023733 0.000000 0.000000 0.023733 0.000000 14225.0 0.023698 0.000000 0.000000 0.023698 0.000000 14230.0 0.023662 0.000000 0.000000 0.023662 0.000000 14235.0 0.023627 0.000000 0.000000 0.023627 0.000000 14240.0 0.023592 0.000000 0.000000 0.023592 0.000000 14245.0 0.023557 0.000000 0.000000 0.023557 0.000000 14250.0 0.023522 0.000000 0.000000 0.023522 0.000000 14255.0 0.023488 0.000000 0.000000 0.023488 0.000000 14260.0 0.023453 0.000000 0.000000 0.023453 0.000000 14265.0 0.023419 0.000000 0.000000 0.023419 0.000000 14270.0 0.023384 0.000000 0.000000 0.023384 0.000000 14275.0 0.023350 0.000000 0.000000 0.023350 0.000000 14280.0 0.023316 0.000000 0.000000 0.023316 0.000000 14285.0 0.023282 0.000000 0.000000 0.023282 0.000000 14290.0 0.023248 0.000000 0.000000 0.023248 0.000000 14295.0 0.023214 0.000000 0.000000 0.023214 0.000000 14300.0 0.023180 0.000000 0.000000 0.023180 0.000000 14305.0 0.023036 0.000135 0.000000 0.023146 0.022926 14310.0 0.022837 0.000337 0.000000 0.023113 0.022562 14315.0 0.022694 0.000472 0.000000 0.023079 0.022308 14320.0 0.022658 0.000475 0.000000 0.023046 0.022270 14325.0 0.022758 0.000312 0.000000 0.023012 0.022503 14330.0 0.022998 0.000023 0.000000 0.022979 0.023016 14335.0 0.023303 0.000437 0.000000 0.022946 0.023660 14340.0 0.023538 0.000766 0.000000 0.022913 0.024164 14345.0 0.023620 0.000906 0.000000 0.022880 0.024360 14350.0 0.023533 0.000840 0.000000 0.022847 0.024219 14355.0 0.023299 0.000593 0.000000 0.022815 0.023783 14360.0 0.022979 0.000242 0.000000 0.022782 0.023177 14365.0 0.022666 0.000103 0.000000 0.022749 0.022582 14370.0 0.022459 0.000315 0.000000 0.022717 0.022202 14375.0 0.022427 0.000315 0.000000 0.022685 0.022170 14380.0 0.022554 0.000121 0.000000 0.022652 0.022455 14385.0 0.022751 0.000160 0.000000 0.022620 0.022882 14390.0 0.022918 0.000404 0.000000 0.022588 0.023248 14395.0 0.022985 0.000525 0.000000 0.022556 0.023413 14400.0 0.022925 0.000491 0.000000 0.022524 0.023326 14405.0 0.022755 0.000321 0.000000 0.022493 0.023017 14410.0 0.022522 0.000074 0.000000 0.022461 0.022583 14415.0 0.022303 0.000155 0.000000 0.022429 0.022176 14420.0 0.022168 0.000282 0.000000 0.022398 0.021937 14425.0 0.022144 0.000272 0.000000 0.022366 0.021922 14430.0 0.022206 0.000159 0.000000 0.022335 0.022076 14435.0 0.022291 0.000016 0.000000 0.022304 0.022278 14440.0 0.022340 0.000081 0.000000 0.022273 0.022406 14445.0 0.022325 0.000102 0.000000 0.022242 0.022409 14450.0 0.022245 0.000043 0.000000 0.022211 0.022280 14455.0 0.022121 0.000073 0.000000 0.022180 0.022061 14460.0 0.021994 0.000190 0.000000 0.022149 0.021839 14465.0 0.021915 0.000249 0.000000 0.022119 0.021712 14470.0 0.021901 0.000229 0.000000 0.022088 0.021714 14475.0 0.021919 0.000170 0.000000 0.022058 0.021780 14480.0 0.021918 0.000134 0.000000 0.022027 0.021809 14485.0 0.021873 0.000152 0.000000 0.021997 0.021749 14490.0 0.021794 0.000211 0.000000 0.021967 0.021622 14495.0 0.021727 0.000257 0.000000 0.021937 0.021518 14500.0 0.021548 0.000779 0.000000 0.000000 0.021548 14505.0 0.021735 0.001095 0.000000 0.000000 0.021735 14510.0 0.021954 0.001493 0.000000 0.000000 0.021954 14515.0 0.022083 0.001494 0.000000 0.000000 0.022083 14520.0 0.022121 0.001121 0.000000 0.000000 0.022121 14525.0 0.022121 0.000700 0.000000 0.000000 0.022121 14530.0 0.022105 0.000693 0.000000 0.000000 0.022105 14535.0 0.022067 0.000916 0.000000 0.000000 0.022067 14540.0 0.022018 0.000953 0.000000 0.000000 0.022018 14545.0 0.021985 0.000724 0.000000 0.000000 0.021985 14550.0 0.021975 0.000135 0.000000 0.000000 0.021975 14555.0 0.021937 0.000300 0.000000 0.000000 0.021937 14560.0 0.021823 0.000734 0.000000 0.000000 0.021823 14565.0 0.021636 0.000869 0.000000 0.000000 0.021636 14570.0 0.021440 0.000739 0.000000 0.000000 0.021440 14575.0 0.021302 0.000440 0.000000 0.000000 0.021302 14580.0 0.021256 0.000242 0.000000 0.000000 0.021256 14585.0 0.021286 0.000387 0.000000 0.000000 0.021286 14590.0 0.021333 0.000570 0.000000 0.000000 0.021333 14595.0 0.021323 0.000683 0.000000 0.000000 0.021323 14600.0 0.021201 0.000770 0.000000 0.000000 0.021201 14605.0 0.020967 0.000810 0.000000 0.000000 0.020967 14610.0 0.020699 0.000708 0.000000 0.000000 0.020699 14615.0 0.020524 0.000424 0.000000 0.000000 0.020524 14620.0 0.020550 0.000041 0.000000 0.000000 0.020550 14625.0 0.020799 0.000591 0.000000 0.000000 0.020799 14630.0 0.021188 0.000992 0.000000 0.000000 0.021188 14635.0 0.021563 0.001147 0.000000 0.000000 0.021563 14640.0 0.021757 0.000954 0.000000 0.000000 0.021757 14645.0 0.021653 0.000449 0.000000 0.000000 0.021653 14650.0 0.021239 0.000547 0.000000 0.000000 0.021239 14655.0 0.020636 0.001209 0.000000 0.000000 0.020636 14660.0 0.020074 0.001586 0.000000 0.000000 0.020074 14665.0 0.019812 0.001425 0.000000 0.000000 0.019812 14670.0 0.019884 0.000971 0.000000 0.000000 0.019884 14675.0 0.020216 0.000845 0.000000 0.000000 0.020216 14680.0 0.020610 0.001210 0.000000 0.000000 0.020610 14685.0 0.020891 0.001440 0.000000 0.000000 0.020891 14690.0 0.020951 0.001331 0.000000 0.000000 0.020951 14695.0 0.020651 0.000767 0.000000 0.000000 0.020651 14700.0 0.020052 0.000731 0.000000 0.000000 0.020052 14705.0 0.019431 0.001563 0.000000 0.000000 0.019431 14710.0 0.019072 0.002116 0.000000 0.000000 0.019072 14715.0 0.019131 0.002095 0.000000 0.000000 0.019131 14720.0 0.019535 0.001619 0.000000 0.000000 0.019535 14725.0 0.020056 0.000997 0.000000 0.000000 0.020056 14730.0 0.020387 0.000603 0.000000 0.000000 0.020387 14735.0 0.020424 0.000460 0.000000 0.000000 0.020424 14740.0 0.020248 0.000454 0.000000 0.000000 0.020248 14745.0 0.019936 0.000523 0.000000 0.000000 0.019936 14750.0 0.019608 0.000587 0.000000 0.000000 0.019608 14755.0 0.019395 0.000744 0.000000 0.000000 0.019395 14760.0 0.019375 0.001090 0.000000 0.000000 0.019375 14765.0 0.019545 0.001451 0.000000 0.000000 0.019545 14770.0 0.019815 0.001569 0.000000 0.000000 0.019815 14775.0 0.020082 0.001349 0.000000 0.000000 0.020082 14780.0 0.020213 0.000714 0.000000 0.000000 0.020213 14785.0 0.020207 0.000455 0.000000 0.000000 0.020207 14790.0 0.020092 0.001242 0.000000 0.000000 0.020092 14795.0 0.019958 0.001835 0.000000 0.000000 0.019958 14800.0 0.019886 0.002040 0.000000 0.000000 0.019886 14805.0 0.019902 0.001829 0.000000 0.000000 0.019902 14810.0 0.019974 0.001351 0.000000 0.000000 0.019974 14815.0 0.020033 0.000817 0.000000 0.000000 0.020033 14820.0 0.020015 0.000415 0.000000 0.000000 0.020015 14825.0 0.019894 0.000249 0.000000 0.000000 0.019894 14830.0 0.019692 0.000329 0.000000 0.000000 0.019692 14835.0 0.019475 0.000511 0.000000 0.000000 0.019475 14840.0 0.019320 0.000638 0.000000 0.000000 0.019320 14845.0 0.019269 0.000641 0.000000 0.000000 0.019269 14850.0 0.019340 0.000506 0.000000 0.000000 0.019340 14855.0 0.019510 0.000322 0.000000 0.000000 0.019510 14860.0 0.019705 0.000311 0.000000 0.000000 0.019705 14865.0 0.019837 0.000440 0.000000 0.000000 0.019837 14870.0 0.019844 0.000545 0.000000 0.000000 0.019844 14875.0 0.019713 0.000684 0.000000 0.000000 0.019713 14880.0 0.019487 0.000903 0.000000 0.000000 0.019487 14885.0 0.019238 0.001115 0.000000 0.000000 0.019238 14890.0 0.019059 0.001169 0.000000 0.000000 0.019059 14895.0 0.019006 0.001006 0.000000 0.000000 0.019006 14900.0 0.019152 0.000542 0.000000 0.000000 0.019152 14905.0 0.019424 0.000170 0.000000 0.000000 0.019424 14910.0 0.019747 0.000459 0.000000 0.000000 0.019747 14915.0 0.020005 0.000779 0.000000 0.000000 0.020005 14920.0 0.020118 0.000768 0.000000 0.000000 0.020118 14925.0 0.020059 0.000512 0.000000 0.000000 0.020059 14930.0 0.019860 0.000152 0.000000 0.000000 0.019860 14935.0 0.019601 0.000284 0.000000 0.000000 0.019601 14940.0 0.019403 0.000435 0.000000 0.000000 0.019403 14945.0 0.019323 0.000315 0.000000 0.000000 0.019323 14950.0 0.019349 0.000164 0.000000 0.000000 0.019349 14955.0 0.019476 0.000368 0.000000 0.000000 0.019476 14960.0 0.019656 0.000694 0.000000 0.000000 0.019656 14965.0 0.019821 0.000894 0.000000 0.000000 0.019821 14970.0 0.019949 0.000974 0.000000 0.000000 0.019949 14975.0 0.020052 0.000977 0.000000 0.000000 0.020052 14980.0 0.020118 0.000976 0.000000 0.000000 0.020118 14985.0 0.020127 0.000992 0.000000 0.000000 0.020127 14990.0 0.020070 0.001009 0.000000 0.000000 0.020070 14995.0 0.019914 0.000883 0.000000 0.000000 0.019914 15000.0 0.019726 0.000713 0.000000 0.000000 0.019726 15005.0 0.019540 0.000594 0.000000 0.000000 0.019540 15010.0 0.019321 0.000415 0.000000 0.000000 0.019321 15015.0 0.019094 0.000282 0.000000 0.000000 0.019094 15020.0 0.018910 0.000455 0.000000 0.000000 0.018910 15025.0 0.018792 0.000698 0.000000 0.000000 0.018792 15030.0 0.018758 0.000807 0.000000 0.000000 0.018758 15035.0 0.018795 0.000714 0.000000 0.000000 0.018795 15040.0 0.018876 0.000418 0.000000 0.000000 0.018876 15045.0 0.018999 0.000312 0.000000 0.000000 0.018999 15050.0 0.019087 0.000576 0.000000 0.000000 0.019087 15055.0 0.019090 0.000796 0.000000 0.000000 0.019090 15060.0 0.019012 0.000819 0.000000 0.000000 0.019012 15065.0 0.018861 0.000647 0.000000 0.000000 0.018861 15070.0 0.018656 0.000322 0.000000 0.000000 0.018656 15075.0 0.018397 0.000124 0.000000 0.000000 0.018397 15080.0 0.018152 0.000555 0.000000 0.000000 0.018152 15085.0 0.017998 0.000920 0.000000 0.000000 0.017998 15090.0 0.017956 0.001193 0.000000 0.000000 0.017956 15095.0 0.018030 0.001312 0.000000 0.000000 0.018030 15100.0 0.018196 0.001247 0.000000 0.000000 0.018196 15105.0 0.018410 0.000978 0.000000 0.000000 0.018410 15110.0 0.018615 0.000563 0.000000 0.000000 0.018615 15115.0 0.018745 0.000113 0.000000 0.000000 0.018745 15120.0 0.018757 0.000297 0.000000 0.000000 0.018757 15125.0 0.018646 0.000479 0.000000 0.000000 0.018646 15130.0 0.018460 0.000433 0.000000 0.000000 0.018460 15135.0 0.018273 0.000289 0.000000 0.000000 0.018273 15140.0 0.018177 0.000324 0.000000 0.000000 0.018177 15145.0 0.018224 0.000469 0.000000 0.000000 0.018224 15150.0 0.018388 0.000460 0.000000 0.000000 0.018388 15155.0 0.018623 0.000259 0.000000 0.000000 0.018623 15160.0 0.018812 0.000296 0.000000 0.000000 0.018812 15165.0 0.018847 0.000526 0.000000 0.000000 0.018847 15170.0 0.018717 0.000651 0.000000 0.000000 0.018717 15175.0 0.018438 0.000544 0.000000 0.000000 0.018438 15180.0 0.018077 0.000235 0.000000 0.000000 0.018077 15185.0 0.017743 0.000282 0.000000 0.000000 0.017743 15190.0 0.017542 0.000784 0.000000 0.000000 0.017542 15195.0 0.017529 0.001047 0.000000 0.000000 0.017529 15200.0 0.017687 0.001055 0.000000 0.000000 0.017687 15205.0 0.017936 0.000814 0.000000 0.000000 0.017936 15210.0 0.018182 0.000423 0.000000 0.000000 0.018182 15215.0 0.018329 0.000090 0.000000 0.000000 0.018329 15220.0 0.018323 0.000194 0.000000 0.000000 0.018323 15225.0 0.018173 0.000214 0.000000 0.000000 0.018173 15230.0 0.017942 0.000053 0.000000 0.000000 0.017942 15235.0 0.017680 0.000322 0.000000 0.000000 0.017680 15240.0 0.017462 0.000636 0.000000 0.000000 0.017462 15245.0 0.017333 0.000811 0.000000 0.000000 0.017333 15250.0 0.017294 0.000784 0.000000 0.000000 0.017294 15255.0 0.017316 0.000588 0.000000 0.000000 0.017316 15260.0 0.017361 0.000304 0.000000 0.000000 0.017361 15265.0 0.017413 0.000128 0.000000 0.000000 0.017413 15270.0 0.017472 0.000174 0.000000 0.000000 0.017472 15275.0 0.017554 0.000201 0.000000 0.000000 0.017554 15280.0 0.017675 0.000137 0.000000 0.000000 0.017675 15285.0 0.017836 0.000174 0.000000 0.000000 0.017836 15290.0 0.017961 0.000371 0.000000 0.000000 0.017961 15295.0 0.018016 0.000583 0.000000 0.000000 0.018016 15300.0 0.017968 0.000745 0.000000 0.000000 0.017968 15305.0 0.017810 0.000845 0.000000 0.000000 0.017810 15310.0 0.017578 0.000870 0.000000 0.000000 0.017578 15315.0 0.017345 0.000812 0.000000 0.000000 0.017345 15320.0 0.017184 0.000680 0.000000 0.000000 0.017184 15325.0 0.017156 0.000507 0.000000 0.000000 0.017156 15330.0 0.017267 0.000401 0.000000 0.000000 0.017267 15335.0 0.017462 0.000474 0.000000 0.000000 0.017462 15340.0 0.017645 0.000647 0.000000 0.000000 0.017645 15345.0 0.017706 0.000768 0.000000 0.000000 0.017706 15350.0 0.017581 0.000797 0.000000 0.000000 0.017581 15355.0 0.017286 0.000787 0.000000 0.000000 0.017286 15360.0 0.016897 0.000800 0.000000 0.000000 0.016897 15365.0 0.016521 0.000869 0.000000 0.000000 0.016521 15370.0 0.016268 0.000968 0.000000 0.000000 0.016268 15375.0 0.016188 0.001045 0.000000 0.000000 0.016188 15380.0 0.016332 0.001065 0.000000 0.000000 0.016332 15385.0 0.016637 0.000998 0.000000 0.000000 0.016637 15390.0 0.017004 0.000840 0.000000 0.000000 0.017004 15395.0 0.017317 0.000579 0.000000 0.000000 0.017317 15400.0 0.017513 0.000270 0.000000 0.000000 0.017513 15405.0 0.017564 0.000085 0.000000 0.000000 0.017564 15410.0 0.017495 0.000240 0.000000 0.000000 0.017495 15415.0 0.017355 0.000348 0.000000 0.000000 0.017355 15420.0 0.017198 0.000343 0.000000 0.000000 0.017198 15425.0 0.017058 0.000239 0.000000 0.000000 0.017058 15430.0 0.016944 0.000073 0.000000 0.000000 0.016944 15435.0 0.016842 0.000219 0.000000 0.000000 0.016842 15440.0 0.016727 0.000594 0.000000 0.000000 0.016727 15445.0 0.016589 0.000952 0.000000 0.000000 0.016589 15450.0 0.016442 0.001239 0.000000 0.000000 0.016442 15455.0 0.016315 0.001363 0.000000 0.000000 0.016315 15460.0 0.016247 0.001281 0.000000 0.000000 0.016247 15465.0 0.016272 0.000994 0.000000 0.000000 0.016272 15470.0 0.016388 0.000587 0.000000 0.000000 0.016388 15475.0 0.016561 0.000171 0.000000 0.000000 0.016561 15480.0 0.016739 0.000139 0.000000 0.000000 0.016739 15485.0 0.016872 0.000294 0.000000 0.000000 0.016872 15490.0 0.016928 0.000331 0.000000 0.000000 0.016928 15495.0 0.016897 0.000375 0.000000 0.000000 0.016897 15500.0 0.016794 0.000466 0.000000 0.000000 0.016794 15505.0 0.016649 0.000527 0.000000 0.000000 0.016649 15510.0 0.016497 0.000506 0.000000 0.000000 0.016497 15515.0 0.016360 0.000430 0.000000 0.000000 0.016360 15520.0 0.016257 0.000361 0.000000 0.000000 0.016257 15525.0 0.016181 0.000317 0.000000 0.000000 0.016181 15530.0 0.016109 0.000290 0.000000 0.000000 0.016109 15535.0 0.016080 0.000344 0.000000 0.000000 0.016080 15540.0 0.016104 0.000503 0.000000 0.000000 0.016104 15545.0 0.016186 0.000628 0.000000 0.000000 0.016186 15550.0 0.016319 0.000609 0.000000 0.000000 0.016319 15555.0 0.016471 0.000417 0.000000 0.000000 0.016471 15560.0 0.016600 0.000168 0.000000 0.000000 0.016600 15565.0 0.016660 0.000294 0.000000 0.000000 0.016660 15570.0 0.016617 0.000525 0.000000 0.000000 0.016617 15575.0 0.016481 0.000547 0.000000 0.000000 0.016481 15580.0 0.016294 0.000344 0.000000 0.000000 0.016294 15585.0 0.016115 0.000102 0.000000 0.000000 0.016115 15590.0 0.016002 0.000455 0.000000 0.000000 0.016002 15595.0 0.015995 0.000858 0.000000 0.000000 0.015995 15600.0 0.016104 0.001062 0.000000 0.000000 0.016104 15605.0 0.016294 0.001039 0.000000 0.000000 0.016294 15610.0 0.016505 0.000795 0.000000 0.000000 0.016505 15615.0 0.016676 0.000408 0.000000 0.000000 0.016676 15620.0 0.016756 0.000065 0.000000 0.000000 0.016756 15625.0 0.016722 0.000434 0.000000 0.000000 0.016722 15630.0 0.016582 0.000706 0.000000 0.000000 0.016582 15635.0 0.016382 0.000818 0.000000 0.000000 0.016382 15640.0 0.016182 0.000774 0.000000 0.000000 0.016182 15645.0 0.016034 0.000619 0.000000 0.000000 0.016034 15650.0 0.015956 0.000406 0.000000 0.000000 0.015956 15655.0 0.015962 0.000194 0.000000 0.000000 0.015962 15660.0 0.015997 0.000121 0.000000 0.000000 0.015997 15665.0 0.016034 0.000246 0.000000 0.000000 0.016034 15670.0 0.016061 0.000326 0.000000 0.000000 0.016061 15675.0 0.016052 0.000342 0.000000 0.000000 0.016052 15680.0 0.015954 0.000327 0.000000 0.000000 0.015954 15685.0 0.015856 0.000257 0.000000 0.000000 0.015856 15690.0 0.015765 0.000122 0.000000 0.000000 0.015765 15695.0 0.015718 0.000094 0.000000 0.000000 0.015718 15700.0 0.015708 0.000387 0.000000 0.000000 0.015708 15705.0 0.015701 0.000618 0.000000 0.000000 0.015701 15710.0 0.015650 0.000752 0.000000 0.000000 0.015650 15715.0 0.015538 0.000753 0.000000 0.000000 0.015538 15720.0 0.015382 0.000682 0.000000 0.000000 0.015382 15725.0 0.015218 0.000660 0.000000 0.000000 0.015218 15730.0 0.015113 0.000751 0.000000 0.000000 0.015113 15735.0 0.015123 0.000830 0.000000 0.000000 0.015123 15740.0 0.015240 0.000787 0.000000 0.000000 0.015240 15745.0 0.015426 0.000628 0.000000 0.000000 0.015426 15750.0 0.015672 0.000374 0.000000 0.000000 0.015672 15755.0 0.015923 0.000170 0.000000 0.000000 0.015923 15760.0 0.016107 0.000242 0.000000 0.000000 0.016107 15765.0 0.016182 0.000426 0.000000 0.000000 0.016182 15770.0 0.016136 0.000492 0.000000 0.000000 0.016136 15775.0 0.015999 0.000458 0.000000 0.000000 0.015999 15780.0 0.015820 0.000349 0.000000 0.000000 0.015820 15785.0 0.015662 0.000188 0.000000 0.000000 0.015662 15790.0 0.015571 0.000100 0.000000 0.000000 0.015571 15795.0 0.015555 0.000222 0.000000 0.000000 0.015555 15800.0 0.015607 0.000435 0.000000 0.000000 0.015607 15805.0 0.015690 0.000635 0.000000 0.000000 0.015690 15810.0 0.015760 0.000798 0.000000 0.000000 0.015760 15815.0 0.015780 0.000885 0.000000 0.000000 0.015780 15820.0 0.015735 0.000872 0.000000 0.000000 0.015735 15825.0 0.015627 0.000745 0.000000 0.000000 0.015627 15830.0 0.015474 0.000522 0.000000 0.000000 0.015474 15835.0 0.015339 0.000292 0.000000 0.000000 0.015339 15840.0 0.015252 0.000198 0.000000 0.000000 0.015252 15845.0 0.015205 0.000282 0.000000 0.000000 0.015205 15850.0 0.015204 0.000407 0.000000 0.000000 0.015204 15855.0 0.015236 0.000475 0.000000 0.000000 0.015236 15860.0 0.015295 0.000481 0.000000 0.000000 0.015295 15865.0 0.015370 0.000414 0.000000 0.000000 0.015370 15870.0 0.015444 0.000272 0.000000 0.000000 0.015444 15875.0 0.015510 0.000178 0.000000 0.000000 0.015510 15880.0 0.015568 0.000280 0.000000 0.000000 0.015568 15885.0 0.015611 0.000468 0.000000 0.000000 0.015611 15890.0 0.015629 0.000605 0.000000 0.000000 0.015629 15895.0 0.015614 0.000668 0.000000 0.000000 0.015614 15900.0 0.015568 0.000655 0.000000 0.000000 0.015568 15905.0 0.015496 0.000592 0.000000 0.000000 0.015496 15910.0 0.015419 0.000521 0.000000 0.000000 0.015419 15915.0 0.015362 0.000461 0.000000 0.000000 0.015362 15920.0 0.015336 0.000423 0.000000 0.000000 0.015336 15925.0 0.015353 0.000449 0.000000 0.000000 0.015353 15930.0 0.015399 0.000495 0.000000 0.000000 0.015399 15935.0 0.015441 0.000453 0.000000 0.000000 0.015441 15940.0 0.015501 0.000404 0.000000 0.000000 0.015501 15945.0 0.015536 0.000342 0.000000 0.000000 0.015536 15950.0 0.015520 0.000276 0.000000 0.000000 0.015520 15955.0 0.015439 0.000229 0.000000 0.000000 0.015439 15960.0 0.015307 0.000238 0.000000 0.000000 0.015307 15965.0 0.015161 0.000324 0.000000 0.000000 0.015161 15970.0 0.015063 0.000476 0.000000 0.000000 0.015063 15975.0 0.015056 0.000662 0.000000 0.000000 0.015056 15980.0 0.015118 0.000848 0.000000 0.000000 0.015118 15985.0 0.015238 0.001006 0.000000 0.000000 0.015238 15990.0 0.015386 0.001109 0.000000 0.000000 0.015386 15995.0 0.015520 0.001134 0.000000 0.000000 0.015520 16000.0 0.015589 0.001068 0.000000 0.000000 0.015589 16005.0 0.015533 0.000938 0.000000 0.000000 0.015533 16010.0 0.015367 0.000745 0.000000 0.000000 0.015367 16015.0 0.015142 0.000504 0.000000 0.000000 0.015142 16020.0 0.014915 0.000287 0.000000 0.000000 0.014915 16025.0 0.014745 0.000215 0.000000 0.000000 0.014745 16030.0 0.014666 0.000249 0.000000 0.000000 0.014666 16035.0 0.014680 0.000248 0.000000 0.000000 0.014680 16040.0 0.014754 0.000174 0.000000 0.000000 0.014754 16045.0 0.014842 0.000158 0.000000 0.000000 0.014842 16050.0 0.014921 0.000286 0.000000 0.000000 0.014921 16055.0 0.014949 0.000437 0.000000 0.000000 0.014949 16060.0 0.014892 0.000527 0.000000 0.000000 0.014892 16065.0 0.014778 0.000550 0.000000 0.000000 0.014778 16070.0 0.014642 0.000502 0.000000 0.000000 0.014642 16075.0 0.014523 0.000422 0.000000 0.000000 0.014523 16080.0 0.014438 0.000399 0.000000 0.000000 0.014438 16085.0 0.014402 0.000422 0.000000 0.000000 0.014402 16090.0 0.014420 0.000416 0.000000 0.000000 0.014420 16095.0 0.014466 0.000354 0.000000 0.000000 0.014466 16100.0 0.014513 0.000241 0.000000 0.000000 0.014513 16105.0 0.014537 0.000128 0.000000 0.000000 0.014537 16110.0 0.014530 0.000139 0.000000 0.000000 0.014530 16115.0 0.014497 0.000302 0.000000 0.000000 0.014497 16120.0 0.014454 0.000510 0.000000 0.000000 0.014454 16125.0 0.014423 0.000759 0.000000 0.000000 0.014423 16130.0 0.014418 0.001004 0.000000 0.000000 0.014418 16135.0 0.014445 0.001173 0.000000 0.000000 0.014445 16140.0 0.014503 0.001218 0.000000 0.000000 0.014503 16145.0 0.014565 0.001112 0.000000 0.000000 0.014565 16150.0 0.014598 0.000861 0.000000 0.000000 0.014598 16155.0 0.014605 0.000541 0.000000 0.000000 0.014605 16160.0 0.014552 0.000242 0.000000 0.000000 0.014552 16165.0 0.014439 0.000421 0.000000 0.000000 0.014439 16170.0 0.014301 0.000737 0.000000 0.000000 0.014301 16175.0 0.014175 0.000949 0.000000 0.000000 0.014175 16180.0 0.014092 0.001017 0.000000 0.000000 0.014092 16185.0 0.014070 0.000948 0.000000 0.000000 0.014070 16190.0 0.014107 0.000770 0.000000 0.000000 0.014107 16195.0 0.014185 0.000533 0.000000 0.000000 0.014185 16200.0 0.014269 0.000256 0.000000 0.000000 0.014269 16205.0 0.014322 0.000084 0.000000 0.000000 0.014322 16210.0 0.014320 0.000169 0.000000 0.000000 0.014320 16215.0 0.014253 0.000332 0.000000 0.000000 0.014253 16220.0 0.014134 0.000393 0.000000 0.000000 0.014134 16225.0 0.013997 0.000400 0.000000 0.000000 0.013997 16230.0 0.013877 0.000353 0.000000 0.000000 0.013877 16235.0 0.013806 0.000274 0.000000 0.000000 0.013806 16240.0 0.013804 0.000184 0.000000 0.000000 0.013804 16245.0 0.013863 0.000102 0.000000 0.000000 0.013863 16250.0 0.013957 0.000092 0.000000 0.000000 0.013957 16255.0 0.014049 0.000186 0.000000 0.000000 0.014049 16260.0 0.014108 0.000288 0.000000 0.000000 0.014108 16265.0 0.014114 0.000354 0.000000 0.000000 0.014114 16270.0 0.014067 0.000351 0.000000 0.000000 0.014067 16275.0 0.013982 0.000270 0.000000 0.000000 0.013982 16280.0 0.013892 0.000132 0.000000 0.000000 0.013892 16285.0 0.013828 0.000204 0.000000 0.000000 0.013828 16290.0 0.013815 0.000421 0.000000 0.000000 0.013815 16295.0 0.013860 0.000611 0.000000 0.000000 0.013860 16300.0 0.013952 0.000720 0.000000 0.000000 0.013952 16305.0 0.014060 0.000723 0.000000 0.000000 0.014060 16310.0 0.014149 0.000623 0.000000 0.000000 0.014149 16315.0 0.014185 0.000451 0.000000 0.000000 0.014185 16320.0 0.014145 0.000231 0.000000 0.000000 0.014145 16325.0 0.014028 0.000066 0.000000 0.000000 0.014028 16330.0 0.013853 0.000116 0.000000 0.000000 0.013853 16335.0 0.013656 0.000208 0.000000 0.000000 0.013656 16340.0 0.013477 0.000223 0.000000 0.000000 0.013477 16345.0 0.013379 0.000156 0.000000 0.000000 0.013379 16350.0 0.013349 0.000100 0.000000 0.000000 0.013349 16355.0 0.013399 0.000234 0.000000 0.000000 0.013399 16360.0 0.013521 0.000436 0.000000 0.000000 0.013521 16365.0 0.013686 0.000631 0.000000 0.000000 0.013686 16370.0 0.013868 0.000808 0.000000 0.000000 0.013868 16375.0 0.014027 0.000941 0.000000 0.000000 0.014027 16380.0 0.014090 0.000919 0.000000 0.000000 0.014090 16385.0 0.014037 0.000750 0.000000 0.000000 0.014037 16390.0 0.013901 0.000530 0.000000 0.000000 0.013901 16395.0 0.013704 0.000348 0.000000 0.000000 0.013704 16400.0 0.013484 0.000352 0.000000 0.000000 0.013484 16405.0 0.013276 0.000522 0.000000 0.000000 0.013276 16410.0 0.013098 0.000686 0.000000 0.000000 0.013098 16415.0 0.012955 0.000787 0.000000 0.000000 0.012955 16420.0 0.012860 0.000824 0.000000 0.000000 0.012860 16425.0 0.012825 0.000798 0.000000 0.000000 0.012825 16430.0 0.012845 0.000697 0.000000 0.000000 0.012845 16435.0 0.012906 0.000536 0.000000 0.000000 0.012906 16440.0 0.013011 0.000323 0.000000 0.000000 0.013011 16445.0 0.013160 0.000089 0.000000 0.000000 0.013160 16450.0 0.013332 0.000128 0.000000 0.000000 0.013332 16455.0 0.013505 0.000324 0.000000 0.000000 0.013505 16460.0 0.013654 0.000376 0.000000 0.000000 0.013654 16465.0 0.013755 0.000344 0.000000 0.000000 0.013755 16470.0 0.013793 0.000230 0.000000 0.000000 0.013793 16475.0 0.013761 0.000110 0.000000 0.000000 0.013761 16480.0 0.013665 0.000124 0.000000 0.000000 0.013665 16485.0 0.013520 0.000212 0.000000 0.000000 0.013520 16490.0 0.013339 0.000228 0.000000 0.000000 0.013339 16495.0 0.013163 0.000179 0.000000 0.000000 0.013163 16500.0 0.013021 0.000139 0.000000 0.000000 0.013021 16505.0 0.012930 0.000216 0.000000 0.000000 0.012930 16510.0 0.012901 0.000354 0.000000 0.000000 0.012901 16515.0 0.012930 0.000453 0.000000 0.000000 0.012930 16520.0 0.013003 0.000485 0.000000 0.000000 0.013003 16525.0 0.013096 0.000440 0.000000 0.000000 0.013096 16530.0 0.013185 0.000331 0.000000 0.000000 0.013185 16535.0 0.013245 0.000174 0.000000 0.000000 0.013245 16540.0 0.013261 0.000051 0.000000 0.000000 0.013261 16545.0 0.013229 0.000171 0.000000 0.000000 0.013229 16550.0 0.013157 0.000294 0.000000 0.000000 0.013157 16555.0 0.013062 0.000369 0.000000 0.000000 0.013062 16560.0 0.012963 0.000403 0.000000 0.000000 0.012963 16565.0 0.012881 0.000402 0.000000 0.000000 0.012881 16570.0 0.012825 0.000381 0.000000 0.000000 0.012825 16575.0 0.012799 0.000345 0.000000 0.000000 0.012799 16580.0 0.012793 0.000300 0.000000 0.000000 0.012793 16585.0 0.012789 0.000258 0.000000 0.000000 0.012789 16590.0 0.012775 0.000246 0.000000 0.000000 0.012775 16595.0 0.012740 0.000304 0.000000 0.000000 0.012740 16600.0 0.012673 0.000427 0.000000 0.000000 0.012673 16605.0 0.012578 0.000568 0.000000 0.000000 0.012578 16610.0 0.012467 0.000681 0.000000 0.000000 0.012467 16615.0 0.012361 0.000739 0.000000 0.000000 0.012361 16620.0 0.012282 0.000725 0.000000 0.000000 0.012282 16625.0 0.012253 0.000634 0.000000 0.000000 0.012253 16630.0 0.012279 0.000483 0.000000 0.000000 0.012279 16635.0 0.012374 0.000327 0.000000 0.000000 0.012374 16640.0 0.012546 0.000320 0.000000 0.000000 0.012546 16645.0 0.012758 0.000551 0.000000 0.000000 0.012758 16650.0 0.012990 0.000817 0.000000 0.000000 0.012990 16655.0 0.013203 0.001029 0.000000 0.000000 0.013203 16660.0 0.013352 0.001130 0.000000 0.000000 0.013352 16665.0 0.013405 0.001095 0.000000 0.000000 0.013405 16670.0 0.013352 0.000932 0.000000 0.000000 0.013352 16675.0 0.013204 0.000685 0.000000 0.000000 0.013204 16680.0 0.012991 0.000393 0.000000 0.000000 0.012991 16685.0 0.012748 0.000208 0.000000 0.000000 0.012748 16690.0 0.012512 0.000271 0.000000 0.000000 0.012512 16695.0 0.012315 0.000443 0.000000 0.000000 0.012315 16700.0 0.012181 0.000554 0.000000 0.000000 0.012181 16705.0 0.012128 0.000598 0.000000 0.000000 0.012128 16710.0 0.012147 0.000571 0.000000 0.000000 0.012147 16715.0 0.012224 0.000502 0.000000 0.000000 0.012224 16720.0 0.012340 0.000458 0.000000 0.000000 0.012340 16725.0 0.012466 0.000461 0.000000 0.000000 0.012466 16730.0 0.012574 0.000476 0.000000 0.000000 0.012574 16735.0 0.012631 0.000444 0.000000 0.000000 0.012631 16740.0 0.012628 0.000355 0.000000 0.000000 0.012628 16745.0 0.012605 0.000265 0.000000 0.000000 0.012605 16750.0 0.012564 0.000182 0.000000 0.000000 0.012564 16755.0 0.012510 0.000181 0.000000 0.000000 0.012510 16760.0 0.012464 0.000220 0.000000 0.000000 0.012464 16765.0 0.012450 0.000231 0.000000 0.000000 0.012450 16770.0 0.012479 0.000243 0.000000 0.000000 0.012479 16775.0 0.012546 0.000330 0.000000 0.000000 0.012546 16780.0 0.012623 0.000494 0.000000 0.000000 0.012623 16785.0 0.012681 0.000658 0.000000 0.000000 0.012681 16790.0 0.012695 0.000754 0.000000 0.000000 0.012695 16795.0 0.012655 0.000770 0.000000 0.000000 0.012655 16800.0 0.012546 0.000692 0.000000 0.000000 0.012546 16805.0 0.012379 0.000539 0.000000 0.000000 0.012379 16810.0 0.012183 0.000352 0.000000 0.000000 0.012183 16815.0 0.011994 0.000214 0.000000 0.000000 0.011994 16820.0 0.011847 0.000191 0.000000 0.000000 0.011847 16825.0 0.011770 0.000229 0.000000 0.000000 0.011770 16830.0 0.011775 0.000225 0.000000 0.000000 0.011775 16835.0 0.011852 0.000200 0.000000 0.000000 0.011852 16840.0 0.011979 0.000227 0.000000 0.000000 0.011979 16845.0 0.012117 0.000311 0.000000 0.000000 0.012117 16850.0 0.012226 0.000403 0.000000 0.000000 0.012226 16855.0 0.012283 0.000453 0.000000 0.000000 0.012283 16860.0 0.012283 0.000441 0.000000 0.000000 0.012283 16865.0 0.012236 0.000395 0.000000 0.000000 0.012236 16870.0 0.012164 0.000371 0.000000 0.000000 0.012164 16875.0 0.012089 0.000388 0.000000 0.000000 0.012089 16880.0 0.012029 0.000421 0.000000 0.000000 0.012029 16885.0 0.012015 0.000442 0.000000 0.000000 0.012015 16890.0 0.012051 0.000449 0.000000 0.000000 0.012051 16895.0 0.012113 0.000480 0.000000 0.000000 0.012113 16900.0 0.012179 0.000564 0.000000 0.000000 0.012179 16905.0 0.012229 0.000679 0.000000 0.000000 0.012229 16910.0 0.012240 0.000766 0.000000 0.000000 0.012240 16915.0 0.012204 0.000787 0.000000 0.000000 0.012204 16920.0 0.012127 0.000733 0.000000 0.000000 0.012127 16925.0 0.012028 0.000624 0.000000 0.000000 0.012028 16930.0 0.011926 0.000505 0.000000 0.000000 0.011926 16935.0 0.011858 0.000427 0.000000 0.000000 0.011858 16940.0 0.011827 0.000377 0.000000 0.000000 0.011827 16945.0 0.011828 0.000317 0.000000 0.000000 0.011828 16950.0 0.011867 0.000221 0.000000 0.000000 0.011867 16955.0 0.011921 0.000114 0.000000 0.000000 0.011921 16960.0 0.011975 0.000131 0.000000 0.000000 0.011975 16965.0 0.012009 0.000250 0.000000 0.000000 0.012009 16970.0 0.012005 0.000360 0.000000 0.000000 0.012005 16975.0 0.011958 0.000411 0.000000 0.000000 0.011958 16980.0 0.011888 0.000385 0.000000 0.000000 0.011888 16985.0 0.011816 0.000283 0.000000 0.000000 0.011816 16990.0 0.011753 0.000163 0.000000 0.000000 0.011753 16995.0 0.011711 0.000123 0.000000 0.000000 0.011711 17000.0 0.011702 0.000196 0.000000 0.000000 0.011702 17005.0 0.011725 0.000259 0.000000 0.000000 0.011725 17010.0 0.011763 0.000255 0.000000 0.000000 0.011763 17015.0 0.011796 0.000192 0.000000 0.000000 0.011796 17020.0 0.011808 0.000081 0.000000 0.000000 0.011808 17025.0 0.011782 0.000029 0.000000 0.000000 0.011782 17030.0 0.011716 0.000158 0.000000 0.000000 0.011716 17035.0 0.011617 0.000241 0.000000 0.000000 0.011617 17040.0 0.011493 0.000286 0.000000 0.000000 0.011493 17045.0 0.011370 0.000287 0.000000 0.000000 0.011370 17050.0 0.011278 0.000236 0.000000 0.000000 0.011278 17055.0 0.011232 0.000175 0.000000 0.000000 0.011232 17060.0 0.011239 0.000169 0.000000 0.000000 0.011239 17065.0 0.011294 0.000225 0.000000 0.000000 0.011294 17070.0 0.011385 0.000275 0.000000 0.000000 0.011385 17075.0 0.011495 0.000284 0.000000 0.000000 0.011495 17080.0 0.011599 0.000248 0.000000 0.000000 0.011599 17085.0 0.011686 0.000184 0.000000 0.000000 0.011686 17090.0 0.011738 0.000158 0.000000 0.000000 0.011738 17095.0 0.011744 0.000217 0.000000 0.000000 0.011744 17100.0 0.011722 0.000320 0.000000 0.000000 0.011722 17105.0 0.011672 0.000400 0.000000 0.000000 0.011672 17110.0 0.011606 0.000428 0.000000 0.000000 0.011606 17115.0 0.011534 0.000389 0.000000 0.000000 0.011534 17120.0 0.011462 0.000292 0.000000 0.000000 0.011462 17125.0 0.011399 0.000136 0.000000 0.000000 0.011399 17130.0 0.011347 0.000052 0.000000 0.000000 0.011347 17135.0 0.011310 0.000198 0.000000 0.000000 0.011310 17140.0 0.011288 0.000316 0.000000 0.000000 0.011288 17145.0 0.011280 0.000370 0.000000 0.000000 0.011280 17150.0 0.011285 0.000355 0.000000 0.000000 0.011285 17155.0 0.011299 0.000272 0.000000 0.000000 0.011299 17160.0 0.011318 0.000131 0.000000 0.000000 0.011318 17165.0 0.011340 0.000054 0.000000 0.000000 0.011340 17170.0 0.011357 0.000214 0.000000 0.000000 0.011357 17175.0 0.011363 0.000357 0.000000 0.000000 0.011363 17180.0 0.011352 0.000440 0.000000 0.000000 0.011352 17185.0 0.011322 0.000468 0.000000 0.000000 0.011322 17190.0 0.011274 0.000436 0.000000 0.000000 0.011274 17195.0 0.011214 0.000364 0.000000 0.000000 0.011214 17200.0 0.011151 0.000282 0.000000 0.000000 0.011151 17205.0 0.011097 0.000221 0.000000 0.000000 0.011097 17210.0 0.011064 0.000203 0.000000 0.000000 0.011064 17215.0 0.011054 0.000217 0.000000 0.000000 0.011054 17220.0 0.011067 0.000234 0.000000 0.000000 0.011067 17225.0 0.011106 0.000237 0.000000 0.000000 0.011106 17230.0 0.011166 0.000236 0.000000 0.000000 0.011166 17235.0 0.011235 0.000239 0.000000 0.000000 0.011235 17240.0 0.011298 0.000248 0.000000 0.000000 0.011298 17245.0 0.011350 0.000260 0.000000 0.000000 0.011350 17250.0 0.011375 0.000262 0.000000 0.000000 0.011375 17255.0 0.011377 0.000260 0.000000 0.000000 0.011377 17260.0 0.011367 0.000262 0.000000 0.000000 0.011367 17265.0 0.011333 0.000250 0.000000 0.000000 0.011333 17270.0 0.011283 0.000232 0.000000 0.000000 0.011283 17275.0 0.011227 0.000215 0.000000 0.000000 0.011227 17280.0 0.011174 0.000205 0.000000 0.000000 0.011174 17285.0 0.011132 0.000203 0.000000 0.000000 0.011132 17290.0 0.011107 0.000206 0.000000 0.000000 0.011107 17295.0 0.011101 0.000212 0.000000 0.000000 0.011101 17300.0 0.011113 0.000226 0.000000 0.000000 0.011113 17305.0 0.011141 0.000253 0.000000 0.000000 0.011141 17310.0 0.011180 0.000292 0.000000 0.000000 0.011180 17315.0 0.011218 0.000334 0.000000 0.000000 0.011218 17320.0 0.011243 0.000365 0.000000 0.000000 0.011243 17325.0 0.011242 0.000370 0.000000 0.000000 0.011242 17330.0 0.011215 0.000343 0.000000 0.000000 0.011215 17335.0 0.011169 0.000290 0.000000 0.000000 0.011169 17340.0 0.011107 0.000217 0.000000 0.000000 0.011107 17345.0 0.011031 0.000122 0.000000 0.000000 0.011031 17350.0 0.010951 0.000073 0.000000 0.000000 0.010951 17355.0 0.010870 0.000154 0.000000 0.000000 0.010870 17360.0 0.010793 0.000275 0.000000 0.000000 0.010793 17365.0 0.010723 0.000393 0.000000 0.000000 0.010723 17370.0 0.010663 0.000489 0.000000 0.000000 0.010663 17375.0 0.010624 0.000552 0.000000 0.000000 0.010624 17380.0 0.010611 0.000574 0.000000 0.000000 0.010611 17385.0 0.010615 0.000541 0.000000 0.000000 0.010615 17390.0 0.010636 0.000463 0.000000 0.000000 0.010636 17395.0 0.010674 0.000358 0.000000 0.000000 0.010674 17400.0 0.010721 0.000253 0.000000 0.000000 0.010721 17405.0 0.010768 0.000192 0.000000 0.000000 0.010768 17410.0 0.010807 0.000195 0.000000 0.000000 0.010807 17415.0 0.010835 0.000216 0.000000 0.000000 0.010835 17420.0 0.010844 0.000221 0.000000 0.000000 0.010844 17425.0 0.010840 0.000165 0.000000 0.000000 0.010840 17430.0 0.010821 0.000083 0.000000 0.000000 0.010821 17435.0 0.010803 0.000071 0.000000 0.000000 0.010803 17440.0 0.010812 0.000144 0.000000 0.000000 0.010812 17445.0 0.010821 0.000179 0.000000 0.000000 0.010821 17450.0 0.010819 0.000184 0.000000 0.000000 0.010819 17455.0 0.010797 0.000168 0.000000 0.000000 0.010797 17460.0 0.010752 0.000136 0.000000 0.000000 0.010752 17465.0 0.010685 0.000104 0.000000 0.000000 0.010685 17470.0 0.010603 0.000089 0.000000 0.000000 0.010603 17475.0 0.010514 0.000097 0.000000 0.000000 0.010514 17480.0 0.010432 0.000116 0.000000 0.000000 0.010432 17485.0 0.010367 0.000133 0.000000 0.000000 0.010367 17490.0 0.010327 0.000146 0.000000 0.000000 0.010327 17495.0 0.010315 0.000154 0.000000 0.000000 0.010315 17500.0 0.010328 0.000158 0.000000 0.000000 0.010328 17505.0 0.010357 0.000155 0.000000 0.000000 0.010357 17510.0 0.010391 0.000142 0.000000 0.000000 0.010391 17515.0 0.010419 0.000121 0.000000 0.000000 0.010419 17520.0 0.010432 0.000094 0.000000 0.000000 0.010432 17525.0 0.010428 0.000068 0.000000 0.000000 0.010428 17530.0 0.010408 0.000048 0.000000 0.000000 0.010408 17535.0 0.010381 0.000039 0.000000 0.000000 0.010381 17540.0 0.010359 0.000054 0.000000 0.000000 0.010359 17545.0 0.010352 0.000103 0.000000 0.000000 0.010352 17550.0 0.010370 0.000182 0.000000 0.000000 0.010370 17555.0 0.010418 0.000282 0.000000 0.000000 0.010418 17560.0 0.010495 0.000388 0.000000 0.000000 0.010495 17565.0 0.010587 0.000481 0.000000 0.000000 0.010587 17570.0 0.010684 0.000548 0.000000 0.000000 0.010684 17575.0 0.010764 0.000576 0.000000 0.000000 0.010764 17580.0 0.010799 0.000539 0.000000 0.000000 0.010799 17585.0 0.010789 0.000461 0.000000 0.000000 0.010789 17590.0 0.010731 0.000355 0.000000 0.000000 0.010731 17595.0 0.010625 0.000240 0.000000 0.000000 0.010625 17600.0 0.010486 0.000170 0.000000 0.000000 0.010486 17605.0 0.010330 0.000188 0.000000 0.000000 0.010330 17610.0 0.010177 0.000246 0.000000 0.000000 0.010177 17615.0 0.010044 0.000291 0.000000 0.000000 0.010044 17620.0 0.009944 0.000303 0.000000 0.000000 0.009944 17625.0 0.009885 0.000282 0.000000 0.000000 0.009885 17630.0 0.009868 0.000234 0.000000 0.000000 0.009868 17635.0 0.009885 0.000170 0.000000 0.000000 0.009885 17640.0 0.009925 0.000111 0.000000 0.000000 0.009925 17645.0 0.009975 0.000094 0.000000 0.000000 0.009975 17650.0 0.010020 0.000117 0.000000 0.000000 0.010020 17655.0 0.010050 0.000137 0.000000 0.000000 0.010050 17660.0 0.010059 0.000130 0.000000 0.000000 0.010059 17665.0 0.010048 0.000091 0.000000 0.000000 0.010048 17670.0 0.010022 0.000042 0.000000 0.000000 0.010022 17675.0 0.009987 0.000038 0.000000 0.000000 0.009987 17680.0 0.009952 0.000103 0.000000 0.000000 0.009952 17685.0 0.009923 0.000142 0.000000 0.000000 0.009923 17690.0 0.009907 0.000147 0.000000 0.000000 0.009907 17695.0 0.009904 0.000101 0.000000 0.000000 0.009904 17700.0 0.009914 0.000044 0.000000 0.000000 0.009914 17705.0 0.009933 0.000069 0.000000 0.000000 0.009933 17710.0 0.009955 0.000170 0.000000 0.000000 0.009955 17715.0 0.009973 0.000267 0.000000 0.000000 0.009973 17720.0 0.009983 0.000323 0.000000 0.000000 0.009983 17725.0 0.009982 0.000332 0.000000 0.000000 0.009982 17730.0 0.009968 0.000284 0.000000 0.000000 0.009968 17735.0 0.009945 0.000180 0.000000 0.000000 0.009945 17740.0 0.009917 0.000066 0.000000 0.000000 0.009917 17745.0 0.009890 0.000097 0.000000 0.000000 0.009890 17750.0 0.009871 0.000279 0.000000 0.000000 0.009871 17755.0 0.009864 0.000411 0.000000 0.000000 0.009864 17760.0 0.009877 0.000506 0.000000 0.000000 0.009877 17765.0 0.009910 0.000566 0.000000 0.000000 0.009910 17770.0 0.009962 0.000590 0.000000 0.000000 0.009962 17775.0 0.010027 0.000593 0.000000 0.000000 0.010027 17780.0 0.010096 0.000583 0.000000 0.000000 0.010096 17785.0 0.010161 0.000566 0.000000 0.000000 0.010161 17790.0 0.010210 0.000540 0.000000 0.000000 0.010210 17795.0 0.010236 0.000505 0.000000 0.000000 0.010236 17800.0 0.010233 0.000465 0.000000 0.000000 0.010233 17805.0 0.010204 0.000427 0.000000 0.000000 0.010204 17810.0 0.010151 0.000406 0.000000 0.000000 0.010151 17815.0 0.010083 0.000407 0.000000 0.000000 0.010083 17820.0 0.010010 0.000427 0.000000 0.000000 0.010010 17825.0 0.009940 0.000456 0.000000 0.000000 0.009940 17830.0 0.009882 0.000482 0.000000 0.000000 0.009882 17835.0 0.009840 0.000505 0.000000 0.000000 0.009840 17840.0 0.009813 0.000526 0.000000 0.000000 0.009813 17845.0 0.009800 0.000545 0.000000 0.000000 0.009800 17850.0 0.009791 0.000560 0.000000 0.000000 0.009791 17855.0 0.009778 0.000559 0.000000 0.000000 0.009778 17860.0 0.009752 0.000527 0.000000 0.000000 0.009752 17865.0 0.009708 0.000456 0.000000 0.000000 0.009708 17870.0 0.009647 0.000342 0.000000 0.000000 0.009647 17875.0 0.009577 0.000189 0.000000 0.000000 0.009577 17880.0 0.009505 0.000075 0.000000 0.000000 0.009505 17885.0 0.009441 0.000129 0.000000 0.000000 0.009441 17890.0 0.009393 0.000303 0.000000 0.000000 0.009393 17895.0 0.009365 0.000410 0.000000 0.000000 0.009365 17900.0 0.009362 0.000461 0.000000 0.000000 0.009362 17905.0 0.009383 0.000445 0.000000 0.000000 0.009383 17910.0 0.009425 0.000355 0.000000 0.000000 0.009425 17915.0 0.009485 0.000208 0.000000 0.000000 0.009485 17920.0 0.009557 0.000097 0.000000 0.000000 0.009557 17925.0 0.009630 0.000245 0.000000 0.000000 0.009630 17930.0 0.009691 0.000484 0.000000 0.000000 0.009691 17935.0 0.009736 0.000640 0.000000 0.000000 0.009736 17940.0 0.009759 0.000734 0.000000 0.000000 0.009759 17945.0 0.009762 0.000747 0.000000 0.000000 0.009762 17950.0 0.009750 0.000683 0.000000 0.000000 0.009750 17955.0 0.009728 0.000561 0.000000 0.000000 0.009728 17960.0 0.009702 0.000406 0.000000 0.000000 0.009702 17965.0 0.009672 0.000246 0.000000 0.000000 0.009672 17970.0 0.009639 0.000109 0.000000 0.000000 0.009639 17975.0 0.009600 0.000069 0.000000 0.000000 0.009600 17980.0 0.009552 0.000108 0.000000 0.000000 0.009552 17985.0 0.009493 0.000122 0.000000 0.000000 0.009493 17990.0 0.009423 0.000105 0.000000 0.000000 0.009423 17995.0 0.009345 0.000085 0.000000 0.000000 0.009345 18000.0 0.009263 0.000090 0.000000 0.000000 0.009263 18005.0 0.009185 0.000122 0.000000 0.000000 0.009185 18010.0 0.009117 0.000146 0.000000 0.000000 0.009117 18015.0 0.009068 0.000149 0.000000 0.000000 0.009068 18020.0 0.009042 0.000131 0.000000 0.000000 0.009042 18025.0 0.009043 0.000110 0.000000 0.000000 0.009043 18030.0 0.009067 0.000116 0.000000 0.000000 0.009067 18035.0 0.009108 0.000159 0.000000 0.000000 0.009108 18040.0 0.009156 0.000218 0.000000 0.000000 0.009156 18045.0 0.009202 0.000275 0.000000 0.000000 0.009202 18050.0 0.009238 0.000323 0.000000 0.000000 0.009238 18055.0 0.009260 0.000358 0.000000 0.000000 0.009260 18060.0 0.009268 0.000379 0.000000 0.000000 0.009268 18065.0 0.009266 0.000384 0.000000 0.000000 0.009266 18070.0 0.009263 0.000371 0.000000 0.000000 0.009263 18075.0 0.009262 0.000342 0.000000 0.000000 0.009262 18080.0 0.009250 0.000327 0.000000 0.000000 0.009250 18085.0 0.009227 0.000323 0.000000 0.000000 0.009227 18090.0 0.009212 0.000313 0.000000 0.000000 0.009212 18095.0 0.009218 0.000299 0.000000 0.000000 0.009218 18100.0 0.009237 0.000296 0.000000 0.000000 0.009237 18105.0 0.009268 0.000314 0.000000 0.000000 0.009268 18110.0 0.009309 0.000352 0.000000 0.000000 0.009309 18115.0 0.009354 0.000411 0.000000 0.000000 0.009354 18120.0 0.009401 0.000493 0.000000 0.000000 0.009401 18125.0 0.009446 0.000601 0.000000 0.000000 0.009446 18130.0 0.009488 0.000734 0.000000 0.000000 0.009488 18135.0 0.009519 0.000874 0.000000 0.000000 0.009519 18140.0 0.009533 0.000998 0.000000 0.000000 0.009533 18145.0 0.009524 0.001082 0.000000 0.000000 0.009524 18150.0 0.009494 0.001113 0.000000 0.000000 0.009494 18155.0 0.009450 0.001089 0.000000 0.000000 0.009450 18160.0 0.009401 0.001021 0.000000 0.000000 0.009401 18165.0 0.009353 0.000923 0.000000 0.000000 0.009353 18170.0 0.009308 0.000814 0.000000 0.000000 0.009308 18175.0 0.009267 0.000711 0.000000 0.000000 0.009267 18180.0 0.009231 0.000629 0.000000 0.000000 0.009231 18185.0 0.009204 0.000583 0.000000 0.000000 0.009204 18190.0 0.009196 0.000587 0.000000 0.000000 0.009196 18195.0 0.009224 0.000661 0.000000 0.000000 0.009224 18200.0 0.009296 0.000812 0.000000 0.000000 0.009296 18205.0 0.009397 0.001006 0.000000 0.000000 0.009397 18210.0 0.009484 0.001156 0.000000 0.000000 0.009484 18215.0 0.009513 0.001188 0.000000 0.000000 0.009513 18220.0 0.009484 0.001096 0.000000 0.000000 0.009484 18225.0 0.009426 0.000934 0.000000 0.000000 0.009426 18230.0 0.009364 0.000756 0.000000 0.000000 0.009364 18235.0 0.009303 0.000598 0.000000 0.000000 0.009303 18240.0 0.009237 0.000478 0.000000 0.000000 0.009237 18245.0 0.009155 0.000398 0.000000 0.000000 0.009155 18250.0 0.009051 0.000346 0.000000 0.000000 0.009051 18255.0 0.008918 0.000314 0.000000 0.000000 0.008918 18260.0 0.008760 0.000309 0.000000 0.000000 0.008760 18265.0 0.008585 0.000353 0.000000 0.000000 0.008585 18270.0 0.008418 0.000423 0.000000 0.000000 0.008418 18275.0 0.008293 0.000470 0.000000 0.000000 0.008293 18280.0 0.008232 0.000458 0.000000 0.000000 0.008232 18285.0 0.008257 0.000368 0.000000 0.000000 0.008257 18290.0 0.008359 0.000226 0.000000 0.000000 0.008359 18295.0 0.008509 0.000123 0.000000 0.000000 0.008509 18300.0 0.008680 0.000166 0.000000 0.000000 0.008680 18305.0 0.008858 0.000281 0.000000 0.000000 0.008858 18310.0 0.009031 0.000411 0.000000 0.000000 0.009031 18315.0 0.009187 0.000541 0.000000 0.000000 0.009187 18320.0 0.009317 0.000658 0.000000 0.000000 0.009317 18325.0 0.009412 0.000758 0.000000 0.000000 0.009412 18330.0 0.009473 0.000853 0.000000 0.000000 0.009473 18335.0 0.009499 0.000963 0.000000 0.000000 0.009499 18340.0 0.009489 0.001094 0.000000 0.000000 0.009489 18345.0 0.009427 0.001199 0.000000 0.000000 0.009427 18350.0 0.009291 0.001206 0.000000 0.000000 0.009291 18355.0 0.009079 0.001071 0.000000 0.000000 0.009079 18360.0 0.008821 0.000819 0.000000 0.000000 0.008821 18365.0 0.008575 0.000499 0.000000 0.000000 0.008575 18370.0 0.008378 0.000249 0.000000 0.000000 0.008378 18375.0 0.008241 0.000221 0.000000 0.000000 0.008241 18380.0 0.008153 0.000415 0.000000 0.000000 0.008153 18385.0 0.008101 0.000632 0.000000 0.000000 0.008101 18390.0 0.008085 0.000749 0.000000 0.000000 0.008085 18395.0 0.008131 0.000730 0.000000 0.000000 0.008131 18400.0 0.008270 0.000485 0.000000 0.000000 0.008270 18405.0 0.008466 0.000239 0.000000 0.000000 0.008466 18410.0 0.008639 0.000229 0.000000 0.000000 0.008639 18415.0 0.008724 0.000440 0.000000 0.000000 0.008724 18420.0 0.008739 0.000566 0.000000 0.000000 0.008739 18425.0 0.008727 0.000589 0.000000 0.000000 0.008727 18430.0 0.008722 0.000594 0.000000 0.000000 0.008722 18435.0 0.008736 0.000584 0.000000 0.000000 0.008736 18440.0 0.008773 0.000581 0.000000 0.000000 0.008773 18445.0 0.008829 0.000598 0.000000 0.000000 0.008829 18450.0 0.008899 0.000650 0.000000 0.000000 0.008899 18455.0 0.008984 0.000767 0.000000 0.000000 0.008984 18460.0 0.009082 0.000952 0.000000 0.000000 0.009082 18465.0 0.009201 0.001228 0.000000 0.000000 0.009201 18470.0 0.009316 0.001539 0.000000 0.000000 0.009316 18475.0 0.009320 0.001669 0.000000 0.000000 0.009320 18480.0 0.009194 0.001587 0.000000 0.000000 0.009194 18485.0 0.008897 0.001157 0.000000 0.000000 0.008897 18490.0 0.008439 0.000426 0.000000 0.000000 0.008439 18495.0 0.008068 0.000258 0.000000 0.000000 0.008068 18500.0 0.007874 0.000470 0.000000 0.000000 0.007874 18505.0 0.007828 0.000610 0.000000 0.000000 0.007828 18510.0 0.007875 0.000646 0.000000 0.000000 0.007875 18515.0 0.007982 0.000623 0.000000 0.000000 0.007982 18520.0 0.008126 0.000558 0.000000 0.000000 0.008126 18525.0 0.008294 0.000449 0.000000 0.000000 0.008294 18530.0 0.008477 0.000341 0.000000 0.000000 0.008477 18535.0 0.008668 0.000403 0.000000 0.000000 0.008668 18540.0 0.008846 0.000649 0.000000 0.000000 0.008846 18545.0 0.008974 0.000921 0.000000 0.000000 0.008974 18550.0 0.009003 0.001073 0.000000 0.000000 0.009003 18555.0 0.008907 0.001035 0.000000 0.000000 0.008907 18560.0 0.008698 0.000801 0.000000 0.000000 0.008698 18565.0 0.008430 0.000444 0.000000 0.000000 0.008430 18570.0 0.008166 0.000176 0.000000 0.000000 0.008166 18575.0 0.007954 0.000197 0.000000 0.000000 0.007954 18580.0 0.007823 0.000455 0.000000 0.000000 0.007823 18585.0 0.007785 0.000583 0.000000 0.000000 0.007785 18590.0 0.007844 0.000564 0.000000 0.000000 0.007844 18595.0 0.007997 0.000405 0.000000 0.000000 0.007997 18600.0 0.008229 0.000191 0.000000 0.000000 0.008229 18605.0 0.008502 0.000373 0.000000 0.000000 0.008502 18610.0 0.008756 0.000769 0.000000 0.000000 0.008756 18615.0 0.008938 0.001054 0.000000 0.000000 0.008938 18620.0 0.009017 0.001196 0.000000 0.000000 0.009017 18625.0 0.008999 0.001199 0.000000 0.000000 0.008999 18630.0 0.008911 0.001097 0.000000 0.000000 0.008911 18635.0 0.008786 0.000939 0.000000 0.000000 0.008786 18640.0 0.008646 0.000756 0.000000 0.000000 0.008646 18645.0 0.008510 0.000573 0.000000 0.000000 0.008510 18650.0 0.008388 0.000411 0.000000 0.000000 0.008388 18655.0 0.008280 0.000274 0.000000 0.000000 0.008280 18660.0 0.008184 0.000168 0.000000 0.000000 0.008184 18665.0 0.008090 0.000088 0.000000 0.000000 0.008090 18670.0 0.007997 0.000055 0.000000 0.000000 0.007997 18675.0 0.007915 0.000122 0.000000 0.000000 0.007915 18680.0 0.007868 0.000199 0.000000 0.000000 0.007868 18685.0 0.007886 0.000262 0.000000 0.000000 0.007886 18690.0 0.007986 0.000397 0.000000 0.000000 0.007986 18695.0 0.008144 0.000619 0.000000 0.000000 0.008144 18700.0 0.008249 0.000752 0.000000 0.000000 0.008249 18705.0 0.008253 0.000701 0.000000 0.000000 0.008253 18710.0 0.008278 0.000668 0.000000 0.000000 0.008278 18715.0 0.008359 0.000707 0.000000 0.000000 0.008359 18720.0 0.008478 0.000808 0.000000 0.000000 0.008478 18725.0 0.008601 0.000965 0.000000 0.000000 0.008601 18730.0 0.008705 0.001169 0.000000 0.000000 0.008705 18735.0 0.008793 0.001397 0.000000 0.000000 0.008793 18740.0 0.008875 0.001619 0.000000 0.000000 0.008875 18745.0 0.008943 0.001797 0.000000 0.000000 0.008943 18750.0 0.008977 0.001895 0.000000 0.000000 0.008977 18755.0 0.008965 0.001895 0.000000 0.000000 0.008965 18760.0 0.008911 0.001801 0.000000 0.000000 0.008911 18765.0 0.008808 0.001619 0.000000 0.000000 0.008808 18770.0 0.008577 0.001148 0.000000 0.000000 0.008577 18775.0 0.008215 0.000457 0.000000 0.000000 0.008215 18780.0 0.007941 0.000262 0.000000 0.000000 0.007941 18785.0 0.007806 0.000392 0.000000 0.000000 0.007806 18790.0 0.007764 0.000481 0.000000 0.000000 0.007764 18795.0 0.007767 0.000448 0.000000 0.000000 0.007767 18800.0 0.007794 0.000347 0.000000 0.000000 0.007794 18805.0 0.007837 0.000223 0.000000 0.000000 0.007837 18810.0 0.007886 0.000125 0.000000 0.000000 0.007886 18815.0 0.007932 0.000153 0.000000 0.000000 0.007932 18820.0 0.007972 0.000254 0.000000 0.000000 0.007972 18825.0 0.007994 0.000328 0.000000 0.000000 0.007994 18830.0 0.007972 0.000324 0.000000 0.000000 0.007972 18835.0 0.007908 0.000212 0.000000 0.000000 0.007908 18840.0 0.007812 0.000096 0.000000 0.000000 0.007812 18845.0 0.007703 0.000131 0.000000 0.000000 0.007703 18850.0 0.007618 0.000243 0.000000 0.000000 0.007618 18855.0 0.007580 0.000318 0.000000 0.000000 0.007580 18860.0 0.007592 0.000289 0.000000 0.000000 0.007592 18865.0 0.007640 0.000179 0.000000 0.000000 0.007640 18870.0 0.007704 0.000092 0.000000 0.000000 0.007704 18875.0 0.007774 0.000121 0.000000 0.000000 0.007774 18880.0 0.007840 0.000271 0.000000 0.000000 0.007840 18885.0 0.007898 0.000436 0.000000 0.000000 0.007898 18890.0 0.007948 0.000564 0.000000 0.000000 0.007948 18895.0 0.007984 0.000663 0.000000 0.000000 0.007984 18900.0 0.008000 0.000710 0.000000 0.000000 0.008000 18905.0 0.007982 0.000692 0.000000 0.000000 0.007982 18910.0 0.007918 0.000580 0.000000 0.000000 0.007918 18915.0 0.007799 0.000333 0.000000 0.000000 0.007799 18920.0 0.007654 0.000149 0.000000 0.000000 0.007654 18925.0 0.007536 0.000152 0.000000 0.000000 0.007536 18930.0 0.007493 0.000252 0.000000 0.000000 0.007493 18935.0 0.007522 0.000276 0.000000 0.000000 0.007522 18940.0 0.007596 0.000207 0.000000 0.000000 0.007596 18945.0 0.007684 0.000161 0.000000 0.000000 0.007684 18950.0 0.007769 0.000184 0.000000 0.000000 0.007769 18955.0 0.007842 0.000248 0.000000 0.000000 0.007842 18960.0 0.007893 0.000301 0.000000 0.000000 0.007893 18965.0 0.007911 0.000326 0.000000 0.000000 0.007911 18970.0 0.007884 0.000300 0.000000 0.000000 0.007884 18975.0 0.007800 0.000245 0.000000 0.000000 0.007800 18980.0 0.007648 0.000260 0.000000 0.000000 0.007648 18985.0 0.007429 0.000450 0.000000 0.000000 0.007429 18990.0 0.007171 0.000777 0.000000 0.000000 0.007171 18995.0 0.006936 0.001057 0.000000 0.000000 0.006936 19000.0 0.006817 0.001130 0.000000 0.000000 0.006817 19005.0 0.006838 0.000959 0.000000 0.000000 0.006838 19010.0 0.006957 0.000633 0.000000 0.000000 0.006957 19015.0 0.007114 0.000337 0.000000 0.000000 0.007114 19020.0 0.007274 0.000276 0.000000 0.000000 0.007274 19025.0 0.007429 0.000477 0.000000 0.000000 0.007429 19030.0 0.007578 0.000675 0.000000 0.000000 0.007578 19035.0 0.007719 0.000808 0.000000 0.000000 0.007719 19040.0 0.007842 0.000891 0.000000 0.000000 0.007842 19045.0 0.007931 0.000908 0.000000 0.000000 0.007931 19050.0 0.007963 0.000842 0.000000 0.000000 0.007963 19055.0 0.007914 0.000647 0.000000 0.000000 0.007914 19060.0 0.007780 0.000342 0.000000 0.000000 0.007780 19065.0 0.007616 0.000283 0.000000 0.000000 0.007616 19070.0 0.007488 0.000448 0.000000 0.000000 0.007488 19075.0 0.007439 0.000533 0.000000 0.000000 0.007439 19080.0 0.007442 0.000499 0.000000 0.000000 0.007442 19085.0 0.007461 0.000384 0.000000 0.000000 0.007461 19090.0 0.007475 0.000246 0.000000 0.000000 0.007475 19095.0 0.007478 0.000135 0.000000 0.000000 0.007478 19100.0 0.007467 0.000118 0.000000 0.000000 0.007467 19105.0 0.007443 0.000197 0.000000 0.000000 0.007443 19110.0 0.007408 0.000259 0.000000 0.000000 0.007408 19115.0 0.007364 0.000272 0.000000 0.000000 0.007364 19120.0 0.007314 0.000237 0.000000 0.000000 0.007314 19125.0 0.007263 0.000157 0.000000 0.000000 0.007263 19130.0 0.007210 0.000108 0.000000 0.000000 0.007210 19135.0 0.007165 0.000135 0.000000 0.000000 0.007165 19140.0 0.007153 0.000197 0.000000 0.000000 0.007153 19145.0 0.007200 0.000176 0.000000 0.000000 0.007200 19150.0 0.007303 0.000110 0.000000 0.000000 0.007303 19155.0 0.007425 0.000144 0.000000 0.000000 0.007425 19160.0 0.007532 0.000243 0.000000 0.000000 0.007532 19165.0 0.007604 0.000342 0.000000 0.000000 0.007604 19170.0 0.007635 0.000403 0.000000 0.000000 0.007635 19175.0 0.007623 0.000419 0.000000 0.000000 0.007623 19180.0 0.007568 0.000402 0.000000 0.000000 0.007568 19185.0 0.007469 0.000333 0.000000 0.000000 0.007469 19190.0 0.007325 0.000128 0.000000 0.000000 0.007325 19195.0 0.007134 0.000062 0.000000 0.000000 0.007134 19200.0 0.006906 0.000356 0.000000 0.000000 0.006906 19205.0 0.006677 0.000706 0.000000 0.000000 0.006677 19210.0 0.006480 0.000996 0.000000 0.000000 0.006480 19215.0 0.006367 0.001180 0.000000 0.000000 0.006367 19220.0 0.006406 0.001140 0.000000 0.000000 0.006406 19225.0 0.006541 0.000965 0.000000 0.000000 0.006541 19230.0 0.006697 0.000775 0.000000 0.000000 0.006697 19235.0 0.006859 0.000598 0.000000 0.000000 0.006859 19240.0 0.007005 0.000465 0.000000 0.000000 0.007005 19245.0 0.007117 0.000395 0.000000 0.000000 0.007117 19250.0 0.007191 0.000372 0.000000 0.000000 0.007191 19255.0 0.007221 0.000375 0.000000 0.000000 0.007221 19260.0 0.007205 0.000386 0.000000 0.000000 0.007205 19265.0 0.007145 0.000405 0.000000 0.000000 0.007145 19270.0 0.007047 0.000444 0.000000 0.000000 0.007047 19275.0 0.006924 0.000504 0.000000 0.000000 0.006924 19280.0 0.006793 0.000575 0.000000 0.000000 0.006793 19285.0 0.006677 0.000628 0.000000 0.000000 0.006677 19290.0 0.006594 0.000642 0.000000 0.000000 0.006594 19295.0 0.006553 0.000610 0.000000 0.000000 0.006553 19300.0 0.006550 0.000547 0.000000 0.000000 0.006550 19305.0 0.006574 0.000475 0.000000 0.000000 0.006574 19310.0 0.006613 0.000411 0.000000 0.000000 0.006613 19315.0 0.006657 0.000359 0.000000 0.000000 0.006657 19320.0 0.006701 0.000322 0.000000 0.000000 0.006701 19325.0 0.006743 0.000307 0.000000 0.000000 0.006743 19330.0 0.006782 0.000321 0.000000 0.000000 0.006782 19335.0 0.006817 0.000358 0.000000 0.000000 0.006817 19340.0 0.006851 0.000400 0.000000 0.000000 0.006851 19345.0 0.006886 0.000426 0.000000 0.000000 0.006886 19350.0 0.006925 0.000424 0.000000 0.000000 0.006925 19355.0 0.006970 0.000387 0.000000 0.000000 0.006970 19360.0 0.007021 0.000313 0.000000 0.000000 0.007021 19365.0 0.007075 0.000222 0.000000 0.000000 0.007075 19370.0 0.007127 0.000157 0.000000 0.000000 0.007127 19375.0 0.007169 0.000175 0.000000 0.000000 0.007169 19380.0 0.007194 0.000253 0.000000 0.000000 0.007194 19385.0 0.007194 0.000307 0.000000 0.000000 0.007194 19390.0 0.007165 0.000318 0.000000 0.000000 0.007165 19395.0 0.007108 0.000265 0.000000 0.000000 0.007108 19400.0 0.007028 0.000146 0.000000 0.000000 0.007028 19405.0 0.006937 0.000079 0.000000 0.000000 0.006937 19410.0 0.006845 0.000132 0.000000 0.000000 0.006845 19415.0 0.006762 0.000279 0.000000 0.000000 0.006762 19420.0 0.006707 0.000405 0.000000 0.000000 0.006707 19425.0 0.006688 0.000461 0.000000 0.000000 0.006688 19430.0 0.006693 0.000474 0.000000 0.000000 0.006693 19435.0 0.006722 0.000439 0.000000 0.000000 0.006722 19440.0 0.006772 0.000357 0.000000 0.000000 0.006772 19445.0 0.006832 0.000244 0.000000 0.000000 0.006832 19450.0 0.006894 0.000129 0.000000 0.000000 0.006894 19455.0 0.006947 0.000073 0.000000 0.000000 0.006947 19460.0 0.006985 0.000138 0.000000 0.000000 0.006985 19465.0 0.006998 0.000220 0.000000 0.000000 0.006998 19470.0 0.006985 0.000244 0.000000 0.000000 0.006985 19475.0 0.006947 0.000227 0.000000 0.000000 0.006947 19480.0 0.006890 0.000166 0.000000 0.000000 0.006890 19485.0 0.006824 0.000091 0.000000 0.000000 0.006824 19490.0 0.006763 0.000067 0.000000 0.000000 0.006763 19495.0 0.006714 0.000100 0.000000 0.000000 0.006714 19500.0 0.006683 0.000160 0.000000 0.000000 0.006683 19505.0 0.006671 0.000200 0.000000 0.000000 0.006671 19510.0 0.006676 0.000214 0.000000 0.000000 0.006676 19515.0 0.006693 0.000214 0.000000 0.000000 0.006693 19520.0 0.006716 0.000200 0.000000 0.000000 0.006716 19525.0 0.006738 0.000179 0.000000 0.000000 0.006738 19530.0 0.006755 0.000155 0.000000 0.000000 0.006755 19535.0 0.006760 0.000130 0.000000 0.000000 0.006760 19540.0 0.006750 0.000110 0.000000 0.000000 0.006750 19545.0 0.006724 0.000099 0.000000 0.000000 0.006724 19550.0 0.006680 0.000111 0.000000 0.000000 0.006680 19555.0 0.006626 0.000144 0.000000 0.000000 0.006626 19560.0 0.006569 0.000184 0.000000 0.000000 0.006569 19565.0 0.006521 0.000214 0.000000 0.000000 0.006521 19570.0 0.006493 0.000222 0.000000 0.000000 0.006493 19575.0 0.006488 0.000207 0.000000 0.000000 0.006488 19580.0 0.006503 0.000177 0.000000 0.000000 0.006503 19585.0 0.006532 0.000147 0.000000 0.000000 0.006532 19590.0 0.006566 0.000121 0.000000 0.000000 0.006566 19595.0 0.006600 0.000094 0.000000 0.000000 0.006600 19600.0 0.006627 0.000062 0.000000 0.000000 0.006627 19605.0 0.006643 0.000036 0.000000 0.000000 0.006643 19610.0 0.006646 0.000063 0.000000 0.000000 0.006646 19615.0 0.006633 0.000148 0.000000 0.000000 0.006633 19620.0 0.006608 0.000244 0.000000 0.000000 0.006608 19625.0 0.006571 0.000334 0.000000 0.000000 0.006571 19630.0 0.006527 0.000413 0.000000 0.000000 0.006527 19635.0 0.006490 0.000465 0.000000 0.000000 0.006490 19640.0 0.006466 0.000477 0.000000 0.000000 0.006466 19645.0 0.006463 0.000441 0.000000 0.000000 0.006463 19650.0 0.006482 0.000367 0.000000 0.000000 0.006482 19655.0 0.006521 0.000229 0.000000 0.000000 0.006521 19660.0 0.006574 0.000061 0.000000 0.000000 0.006574 19665.0 0.006632 0.000063 0.000000 0.000000 0.006632 19670.0 0.006687 0.000200 0.000000 0.000000 0.006687 19675.0 0.006732 0.000310 0.000000 0.000000 0.006732 19680.0 0.006764 0.000379 0.000000 0.000000 0.006764 19685.0 0.006779 0.000415 0.000000 0.000000 0.006779 19690.0 0.006780 0.000416 0.000000 0.000000 0.006780 19695.0 0.006768 0.000392 0.000000 0.000000 0.006768 19700.0 0.006745 0.000352 0.000000 0.000000 0.006745 19705.0 0.006715 0.000307 0.000000 0.000000 0.006715 19710.0 0.006680 0.000263 0.000000 0.000000 0.006680 19715.0 0.006645 0.000228 0.000000 0.000000 0.006645 19720.0 0.006610 0.000204 0.000000 0.000000 0.006610 19725.0 0.006576 0.000190 0.000000 0.000000 0.006576 19730.0 0.006544 0.000185 0.000000 0.000000 0.006544 19735.0 0.006510 0.000180 0.000000 0.000000 0.006510 19740.0 0.006476 0.000170 0.000000 0.000000 0.006476 19745.0 0.006438 0.000152 0.000000 0.000000 0.006438 19750.0 0.006396 0.000129 0.000000 0.000000 0.006396 19755.0 0.006353 0.000123 0.000000 0.000000 0.006353 19760.0 0.006308 0.000162 0.000000 0.000000 0.006308 19765.0 0.006265 0.000236 0.000000 0.000000 0.006265 19770.0 0.006228 0.000324 0.000000 0.000000 0.006228 19775.0 0.006199 0.000408 0.000000 0.000000 0.006199 19780.0 0.006182 0.000475 0.000000 0.000000 0.006182 19785.0 0.006179 0.000516 0.000000 0.000000 0.006179 19790.0 0.006190 0.000524 0.000000 0.000000 0.006190 19795.0 0.006215 0.000497 0.000000 0.000000 0.006215 19800.0 0.006251 0.000436 0.000000 0.000000 0.006251 19805.0 0.006291 0.000345 0.000000 0.000000 0.006291 19810.0 0.006333 0.000235 0.000000 0.000000 0.006333 19815.0 0.006376 0.000132 0.000000 0.000000 0.006376 19820.0 0.006417 0.000109 0.000000 0.000000 0.006417 19825.0 0.006456 0.000169 0.000000 0.000000 0.006456 19830.0 0.006491 0.000236 0.000000 0.000000 0.006491 19835.0 0.006515 0.000268 0.000000 0.000000 0.006515 19840.0 0.006523 0.000257 0.000000 0.000000 0.006523 19845.0 0.006520 0.000221 0.000000 0.000000 0.006520 19850.0 0.006505 0.000159 0.000000 0.000000 0.006505 19855.0 0.006476 0.000084 0.000000 0.000000 0.006476 19860.0 0.006435 0.000070 0.000000 0.000000 0.006435 19865.0 0.006385 0.000123 0.000000 0.000000 0.006385 19870.0 0.006328 0.000191 0.000000 0.000000 0.006328 19875.0 0.006268 0.000247 0.000000 0.000000 0.006268 19880.0 0.006209 0.000280 0.000000 0.000000 0.006209 19885.0 0.006155 0.000289 0.000000 0.000000 0.006155 19890.0 0.006109 0.000274 0.000000 0.000000 0.006109 19895.0 0.006076 0.000238 0.000000 0.000000 0.006076 19900.0 0.006057 0.000188 0.000000 0.000000 0.006057 19905.0 0.006052 0.000131 0.000000 0.000000 0.006052 19910.0 0.006063 0.000075 0.000000 0.000000 0.006063 19915.0 0.006085 0.000046 0.000000 0.000000 0.006085 19920.0 0.006118 0.000048 0.000000 0.000000 0.006118 19925.0 0.006156 0.000060 0.000000 0.000000 0.006156 19930.0 0.006197 0.000066 0.000000 0.000000 0.006197 19935.0 0.006236 0.000054 0.000000 0.000000 0.006236 19940.0 0.006268 0.000034 0.000000 0.000000 0.006268 19945.0 0.006290 0.000030 0.000000 0.000000 0.006290 19950.0 0.006300 0.000062 0.000000 0.000000 0.006300 19955.0 0.006294 0.000106 0.000000 0.000000 0.006294 19960.0 0.006273 0.000147 0.000000 0.000000 0.006273 19965.0 0.006235 0.000184 0.000000 0.000000 0.006235 19970.0 0.006185 0.000214 0.000000 0.000000 0.006185 19975.0 0.006124 0.000234 0.000000 0.000000 0.006124 19980.0 0.006057 0.000245 0.000000 0.000000 0.006057 19985.0 0.005990 0.000246 0.000000 0.000000 0.005990 19990.0 0.005929 0.000237 0.000000 0.000000 0.005929 19995.0 0.005880 0.000219 0.000000 0.000000 0.005880 20000.0 0.005850 0.000195 0.000000 0.000000 0.005850 20005.0 0.005845 0.000164 0.000000 0.000000 0.005845 20010.0 0.005867 0.000109 0.000000 0.000000 0.005867 20015.0 0.005919 0.000050 0.000000 0.000000 0.005919 20020.0 0.006001 0.000056 0.000000 0.000000 0.006001 20025.0 0.006109 0.000135 0.000000 0.000000 0.006109 20030.0 0.006230 0.000262 0.000000 0.000000 0.006230 20035.0 0.006337 0.000389 0.000000 0.000000 0.006337 20040.0 0.006401 0.000477 0.000000 0.000000 0.006401 20045.0 0.006397 0.000492 0.000000 0.000000 0.006397 20050.0 0.006310 0.000420 0.000000 0.000000 0.006310 20055.0 0.006166 0.000306 0.000000 0.000000 0.006166 20060.0 0.006040 0.000250 0.000000 0.000000 0.006040 20065.0 0.005956 0.000246 0.000000 0.000000 0.005956 20070.0 0.005913 0.000245 0.000000 0.000000 0.005913 20075.0 0.005909 0.000237 0.000000 0.000000 0.005909 20080.0 0.005937 0.000234 0.000000 0.000000 0.005937 20085.0 0.005990 0.000257 0.000000 0.000000 0.005990 20090.0 0.006062 0.000313 0.000000 0.000000 0.006062 20095.0 0.006146 0.000399 0.000000 0.000000 0.006146 20100.0 0.006237 0.000508 0.000000 0.000000 0.006237 20105.0 0.006327 0.000629 0.000000 0.000000 0.006327 20110.0 0.006407 0.000752 0.000000 0.000000 0.006407 20115.0 0.006466 0.000859 0.000000 0.000000 0.006466 20120.0 0.006488 0.000923 0.000000 0.000000 0.006488 20125.0 0.006452 0.000913 0.000000 0.000000 0.006452 20130.0 0.006346 0.000786 0.000000 0.000000 0.006346 20135.0 0.006167 0.000539 0.000000 0.000000 0.006167 20140.0 0.005937 0.000256 0.000000 0.000000 0.005937 20145.0 0.005692 0.000162 0.000000 0.000000 0.005692 20150.0 0.005476 0.000451 0.000000 0.000000 0.005476 20155.0 0.005313 0.000805 0.000000 0.000000 0.005313 20160.0 0.005215 0.000995 0.000000 0.000000 0.005215 20165.0 0.005178 0.001109 0.000000 0.000000 0.005178 20170.0 0.005193 0.001170 0.000000 0.000000 0.005193 20175.0 0.005247 0.001170 0.000000 0.000000 0.005247 20180.0 0.005329 0.001119 0.000000 0.000000 0.005329 20185.0 0.005428 0.001029 0.000000 0.000000 0.005428 20190.0 0.005533 0.000908 0.000000 0.000000 0.005533 20195.0 0.005635 0.000768 0.000000 0.000000 0.005635 20200.0 0.005726 0.000622 0.000000 0.000000 0.005726 20205.0 0.005798 0.000487 0.000000 0.000000 0.005798 20210.0 0.005847 0.000377 0.000000 0.000000 0.005847 20215.0 0.005872 0.000304 0.000000 0.000000 0.005872 20220.0 0.005874 0.000262 0.000000 0.000000 0.005874 20225.0 0.005858 0.000238 0.000000 0.000000 0.005858 20230.0 0.005831 0.000215 0.000000 0.000000 0.005831 20235.0 0.005799 0.000185 0.000000 0.000000 0.005799 20240.0 0.005767 0.000152 0.000000 0.000000 0.005767 20245.0 0.005743 0.000125 0.000000 0.000000 0.005743 20250.0 0.005728 0.000115 0.000000 0.000000 0.005728 20255.0 0.005725 0.000124 0.000000 0.000000 0.005725 20260.0 0.005734 0.000145 0.000000 0.000000 0.005734 20265.0 0.005754 0.000164 0.000000 0.000000 0.005754 20270.0 0.005785 0.000168 0.000000 0.000000 0.005785 20275.0 0.005826 0.000156 0.000000 0.000000 0.005826 20280.0 0.005869 0.000133 0.000000 0.000000 0.005869 20285.0 0.005912 0.000107 0.000000 0.000000 0.005912 20290.0 0.005952 0.000088 0.000000 0.000000 0.005952 20295.0 0.005986 0.000092 0.000000 0.000000 0.005986 20300.0 0.006010 0.000116 0.000000 0.000000 0.006010 20305.0 0.006023 0.000142 0.000000 0.000000 0.006023 20310.0 0.006025 0.000160 0.000000 0.000000 0.006025 20315.0 0.006015 0.000167 0.000000 0.000000 0.006015 20320.0 0.005996 0.000162 0.000000 0.000000 0.005996 20325.0 0.005969 0.000150 0.000000 0.000000 0.005969 20330.0 0.005936 0.000137 0.000000 0.000000 0.005936 20335.0 0.005900 0.000136 0.000000 0.000000 0.005900 20340.0 0.005862 0.000151 0.000000 0.000000 0.005862 20345.0 0.005824 0.000178 0.000000 0.000000 0.005824 20350.0 0.005787 0.000208 0.000000 0.000000 0.005787 20355.0 0.005753 0.000234 0.000000 0.000000 0.005753 20360.0 0.005723 0.000250 0.000000 0.000000 0.005723 20365.0 0.005696 0.000255 0.000000 0.000000 0.005696 20370.0 0.005673 0.000247 0.000000 0.000000 0.005673 20375.0 0.005652 0.000230 0.000000 0.000000 0.005652 20380.0 0.005633 0.000208 0.000000 0.000000 0.005633 20385.0 0.005616 0.000185 0.000000 0.000000 0.005616 20390.0 0.005599 0.000166 0.000000 0.000000 0.005599 20395.0 0.005584 0.000155 0.000000 0.000000 0.005584 20400.0 0.005569 0.000154 0.000000 0.000000 0.005569 20405.0 0.005556 0.000165 0.000000 0.000000 0.005556 20410.0 0.005546 0.000187 0.000000 0.000000 0.005546 20415.0 0.005539 0.000217 0.000000 0.000000 0.005539 20420.0 0.005539 0.000249 0.000000 0.000000 0.005539 20425.0 0.005545 0.000279 0.000000 0.000000 0.005545 20430.0 0.005558 0.000301 0.000000 0.000000 0.005558 20435.0 0.005578 0.000310 0.000000 0.000000 0.005578 20440.0 0.005606 0.000305 0.000000 0.000000 0.005606 20445.0 0.005639 0.000284 0.000000 0.000000 0.005639 20450.0 0.005674 0.000251 0.000000 0.000000 0.005674 20455.0 0.005711 0.000211 0.000000 0.000000 0.005711 20460.0 0.005745 0.000172 0.000000 0.000000 0.005745 20465.0 0.005774 0.000147 0.000000 0.000000 0.005774 20470.0 0.005798 0.000141 0.000000 0.000000 0.005798 20475.0 0.005813 0.000150 0.000000 0.000000 0.005813 20480.0 0.005819 0.000161 0.000000 0.000000 0.005819 20485.0 0.005817 0.000168 0.000000 0.000000 0.005817 20490.0 0.005808 0.000166 0.000000 0.000000 0.005808 20495.0 0.005789 0.000149 0.000000 0.000000 0.005789 20500.0 0.005764 0.000123 0.000000 0.000000 0.005764 20505.0 0.005737 0.000098 0.000000 0.000000 0.005737 20510.0 0.005710 0.000079 0.000000 0.000000 0.005710 20515.0 0.005684 0.000068 0.000000 0.000000 0.005684 20520.0 0.005663 0.000059 0.000000 0.000000 0.005663 20525.0 0.005647 0.000056 0.000000 0.000000 0.005647 20530.0 0.005636 0.000069 0.000000 0.000000 0.005636 20535.0 0.005631 0.000103 0.000000 0.000000 0.005631 20540.0 0.005628 0.000156 0.000000 0.000000 0.005628 20545.0 0.005624 0.000214 0.000000 0.000000 0.005624 20550.0 0.005617 0.000263 0.000000 0.000000 0.005617 20555.0 0.005604 0.000295 0.000000 0.000000 0.005604 20560.0 0.005586 0.000303 0.000000 0.000000 0.005586 20565.0 0.005562 0.000284 0.000000 0.000000 0.005562 20570.0 0.005537 0.000244 0.000000 0.000000 0.005537 20575.0 0.005512 0.000182 0.000000 0.000000 0.005512 20580.0 0.005492 0.000099 0.000000 0.000000 0.005492 20585.0 0.005479 0.000046 0.000000 0.000000 0.005479 20590.0 0.005476 0.000068 0.000000 0.000000 0.005476 20595.0 0.005484 0.000119 0.000000 0.000000 0.005484 20600.0 0.005505 0.000157 0.000000 0.000000 0.005505 20605.0 0.005536 0.000174 0.000000 0.000000 0.005536 20610.0 0.005576 0.000167 0.000000 0.000000 0.005576 20615.0 0.005622 0.000144 0.000000 0.000000 0.005622 20620.0 0.005671 0.000131 0.000000 0.000000 0.005671 20625.0 0.005719 0.000152 0.000000 0.000000 0.005719 20630.0 0.005762 0.000209 0.000000 0.000000 0.005762 20635.0 0.005795 0.000288 0.000000 0.000000 0.005795 20640.0 0.005817 0.000365 0.000000 0.000000 0.005817 20645.0 0.005823 0.000426 0.000000 0.000000 0.005823 20650.0 0.005812 0.000463 0.000000 0.000000 0.005812 20655.0 0.005784 0.000471 0.000000 0.000000 0.005784 20660.0 0.005740 0.000448 0.000000 0.000000 0.005740 20665.0 0.005683 0.000395 0.000000 0.000000 0.005683 20670.0 0.005620 0.000321 0.000000 0.000000 0.005620 20675.0 0.005554 0.000237 0.000000 0.000000 0.005554 20680.0 0.005493 0.000143 0.000000 0.000000 0.005493 20685.0 0.005441 0.000060 0.000000 0.000000 0.005441 20690.0 0.005399 0.000029 0.000000 0.000000 0.005399 20695.0 0.005369 0.000043 0.000000 0.000000 0.005369 20700.0 0.005349 0.000064 0.000000 0.000000 0.005349 20705.0 0.005336 0.000075 0.000000 0.000000 0.005336 20710.0 0.005328 0.000069 0.000000 0.000000 0.005328 20715.0 0.005322 0.000058 0.000000 0.000000 0.005322 20720.0 0.005317 0.000050 0.000000 0.000000 0.005317 20725.0 0.005309 0.000052 0.000000 0.000000 0.005309 20730.0 0.005299 0.000060 0.000000 0.000000 0.005299 20735.0 0.005288 0.000067 0.000000 0.000000 0.005288 20740.0 0.005278 0.000070 0.000000 0.000000 0.005278 20745.0 0.005269 0.000068 0.000000 0.000000 0.005269 20750.0 0.005265 0.000061 0.000000 0.000000 0.005265 20755.0 0.005268 0.000052 0.000000 0.000000 0.005268 20760.0 0.005277 0.000044 0.000000 0.000000 0.005277 20765.0 0.005294 0.000041 0.000000 0.000000 0.005294 20770.0 0.005317 0.000047 0.000000 0.000000 0.005317 20775.0 0.005344 0.000062 0.000000 0.000000 0.005344 20780.0 0.005373 0.000082 0.000000 0.000000 0.005373 20785.0 0.005401 0.000104 0.000000 0.000000 0.005401 20790.0 0.005424 0.000124 0.000000 0.000000 0.005424 20795.0 0.005439 0.000141 0.000000 0.000000 0.005439 20800.0 0.005445 0.000152 0.000000 0.000000 0.005445 20805.0 0.005440 0.000154 0.000000 0.000000 0.005440 20810.0 0.005423 0.000147 0.000000 0.000000 0.005423 20815.0 0.005396 0.000130 0.000000 0.000000 0.005396 20820.0 0.005360 0.000105 0.000000 0.000000 0.005360 20825.0 0.005319 0.000072 0.000000 0.000000 0.005319 20830.0 0.005275 0.000038 0.000000 0.000000 0.005275 20835.0 0.005235 0.000026 0.000000 0.000000 0.005235 20840.0 0.005200 0.000042 0.000000 0.000000 0.005200 20845.0 0.005174 0.000061 0.000000 0.000000 0.005174 20850.0 0.005159 0.000071 0.000000 0.000000 0.005159 20855.0 0.005155 0.000069 0.000000 0.000000 0.005155 20860.0 0.005161 0.000057 0.000000 0.000000 0.005161 20865.0 0.005174 0.000038 0.000000 0.000000 0.005174 20870.0 0.005190 0.000022 0.000000 0.000000 0.005190 20875.0 0.005207 0.000019 0.000000 0.000000 0.005207 20880.0 0.005221 0.000028 0.000000 0.000000 0.005221 20885.0 0.005230 0.000040 0.000000 0.000000 0.005230 20890.0 0.005230 0.000043 0.000000 0.000000 0.005230 20895.0 0.005222 0.000035 0.000000 0.000000 0.005222 20900.0 0.005206 0.000022 0.000000 0.000000 0.005206 20905.0 0.005181 0.000027 0.000000 0.000000 0.005181 20910.0 0.005151 0.000056 0.000000 0.000000 0.005151 20915.0 0.005117 0.000094 0.000000 0.000000 0.005117 20920.0 0.005083 0.000132 0.000000 0.000000 0.005083 20925.0 0.005052 0.000167 0.000000 0.000000 0.005052 20930.0 0.005025 0.000195 0.000000 0.000000 0.005025 20935.0 0.005005 0.000215 0.000000 0.000000 0.005005 20940.0 0.004992 0.000225 0.000000 0.000000 0.004992 20945.0 0.004986 0.000226 0.000000 0.000000 0.004986 20950.0 0.004985 0.000220 0.000000 0.000000 0.004985 20955.0 0.004990 0.000208 0.000000 0.000000 0.004990 20960.0 0.004999 0.000192 0.000000 0.000000 0.004999 20965.0 0.005009 0.000174 0.000000 0.000000 0.005009 20970.0 0.005019 0.000156 0.000000 0.000000 0.005019 20975.0 0.005027 0.000140 0.000000 0.000000 0.005027 20980.0 0.005033 0.000125 0.000000 0.000000 0.005033 20985.0 0.005038 0.000111 0.000000 0.000000 0.005038 20990.0 0.005040 0.000096 0.000000 0.000000 0.005040 20995.0 0.005042 0.000080 0.000000 0.000000 0.005042 21000.0 0.005044 0.000065 0.000000 0.000000 0.005044 21005.0 0.005046 0.000054 0.000000 0.000000 0.005046 21010.0 0.005049 0.000055 0.000000 0.000000 0.005049 21015.0 0.005052 0.000071 0.000000 0.000000 0.005052 21020.0 0.005056 0.000095 0.000000 0.000000 0.005056 21025.0 0.005060 0.000121 0.000000 0.000000 0.005060 21030.0 0.005062 0.000146 0.000000 0.000000 0.005062 21035.0 0.005062 0.000168 0.000000 0.000000 0.005062 21040.0 0.005058 0.000186 0.000000 0.000000 0.005058 21045.0 0.005051 0.000199 0.000000 0.000000 0.005051 21050.0 0.005039 0.000209 0.000000 0.000000 0.005039 21055.0 0.005024 0.000214 0.000000 0.000000 0.005024 21060.0 0.005006 0.000217 0.000000 0.000000 0.005006 21065.0 0.004987 0.000215 0.000000 0.000000 0.004987 21070.0 0.004969 0.000209 0.000000 0.000000 0.004969 21075.0 0.004954 0.000197 0.000000 0.000000 0.004954 21080.0 0.004944 0.000177 0.000000 0.000000 0.004944 21085.0 0.004941 0.000150 0.000000 0.000000 0.004941 21090.0 0.004945 0.000120 0.000000 0.000000 0.004945 21095.0 0.004956 0.000097 0.000000 0.000000 0.004956 21100.0 0.004974 0.000097 0.000000 0.000000 0.004974 21105.0 0.004996 0.000121 0.000000 0.000000 0.004996 21110.0 0.005021 0.000155 0.000000 0.000000 0.005021 21115.0 0.005046 0.000185 0.000000 0.000000 0.005046 21120.0 0.005067 0.000203 0.000000 0.000000 0.005067 21125.0 0.005084 0.000205 0.000000 0.000000 0.005084 21130.0 0.005094 0.000189 0.000000 0.000000 0.005094 21135.0 0.005096 0.000151 0.000000 0.000000 0.005096 21140.0 0.005090 0.000100 0.000000 0.000000 0.005090 21145.0 0.005078 0.000054 0.000000 0.000000 0.005078 21150.0 0.005061 0.000044 0.000000 0.000000 0.005061 21155.0 0.005041 0.000093 0.000000 0.000000 0.005041 21160.0 0.005021 0.000165 0.000000 0.000000 0.005021 21165.0 0.005001 0.000215 0.000000 0.000000 0.005001 21170.0 0.004985 0.000243 0.000000 0.000000 0.004985 21175.0 0.004972 0.000255 0.000000 0.000000 0.004972 21180.0 0.004963 0.000247 0.000000 0.000000 0.004963 21185.0 0.004957 0.000221 0.000000 0.000000 0.004957 21190.0 0.004953 0.000183 0.000000 0.000000 0.004953 21195.0 0.004949 0.000141 0.000000 0.000000 0.004949 21200.0 0.004943 0.000105 0.000000 0.000000 0.004943 21205.0 0.004933 0.000087 0.000000 0.000000 0.004933 21210.0 0.004919 0.000091 0.000000 0.000000 0.004919 21215.0 0.004901 0.000101 0.000000 0.000000 0.004901 21220.0 0.004877 0.000102 0.000000 0.000000 0.004877 21225.0 0.004851 0.000089 0.000000 0.000000 0.004851 21230.0 0.004823 0.000065 0.000000 0.000000 0.004823 21235.0 0.004798 0.000041 0.000000 0.000000 0.004798 21240.0 0.004777 0.000031 0.000000 0.000000 0.004777 21245.0 0.004764 0.000052 0.000000 0.000000 0.004764 21250.0 0.004761 0.000082 0.000000 0.000000 0.004761 21255.0 0.004769 0.000097 0.000000 0.000000 0.004769 21260.0 0.004788 0.000093 0.000000 0.000000 0.004788 21265.0 0.004817 0.000072 0.000000 0.000000 0.004817 21270.0 0.004853 0.000046 0.000000 0.000000 0.004853 21275.0 0.004891 0.000034 0.000000 0.000000 0.004891 21280.0 0.004925 0.000059 0.000000 0.000000 0.004925 21285.0 0.004951 0.000111 0.000000 0.000000 0.004951 21290.0 0.004970 0.000159 0.000000 0.000000 0.004970 21295.0 0.004979 0.000196 0.000000 0.000000 0.004979 21300.0 0.004975 0.000222 0.000000 0.000000 0.004975 21305.0 0.004959 0.000235 0.000000 0.000000 0.004959 21310.0 0.004931 0.000231 0.000000 0.000000 0.004931 21315.0 0.004894 0.000212 0.000000 0.000000 0.004894 21320.0 0.004850 0.000180 0.000000 0.000000 0.004850 21325.0 0.004804 0.000136 0.000000 0.000000 0.004804 21330.0 0.004760 0.000090 0.000000 0.000000 0.004760 21335.0 0.004723 0.000056 0.000000 0.000000 0.004723 21340.0 0.004695 0.000046 0.000000 0.000000 0.004695 21345.0 0.004677 0.000066 0.000000 0.000000 0.004677 21350.0 0.004670 0.000095 0.000000 0.000000 0.004670 21355.0 0.004678 0.000111 0.000000 0.000000 0.004678 21360.0 0.004700 0.000110 0.000000 0.000000 0.004700 21365.0 0.004736 0.000100 0.000000 0.000000 0.004736 21370.0 0.004781 0.000099 0.000000 0.000000 0.004781 21375.0 0.004832 0.000118 0.000000 0.000000 0.004832 21380.0 0.004883 0.000160 0.000000 0.000000 0.004883 21385.0 0.004931 0.000215 0.000000 0.000000 0.004931 21390.0 0.004970 0.000270 0.000000 0.000000 0.004970 21395.0 0.004998 0.000318 0.000000 0.000000 0.004998 21400.0 0.005012 0.000353 0.000000 0.000000 0.005012 21405.0 0.005011 0.000372 0.000000 0.000000 0.005011 21410.0 0.004997 0.000376 0.000000 0.000000 0.004997 21415.0 0.004971 0.000365 0.000000 0.000000 0.004971 21420.0 0.004936 0.000342 0.000000 0.000000 0.004936 21425.0 0.004897 0.000310 0.000000 0.000000 0.004897 21430.0 0.004855 0.000273 0.000000 0.000000 0.004855 21435.0 0.004814 0.000235 0.000000 0.000000 0.004814 21440.0 0.004777 0.000198 0.000000 0.000000 0.004777 21445.0 0.004747 0.000164 0.000000 0.000000 0.004747 21450.0 0.004723 0.000133 0.000000 0.000000 0.004723 21455.0 0.004704 0.000106 0.000000 0.000000 0.004704 21460.0 0.004689 0.000082 0.000000 0.000000 0.004689 21465.0 0.004679 0.000063 0.000000 0.000000 0.004679 21470.0 0.004672 0.000056 0.000000 0.000000 0.004672 21475.0 0.004667 0.000065 0.000000 0.000000 0.004667 21480.0 0.004662 0.000086 0.000000 0.000000 0.004662 21485.0 0.004656 0.000114 0.000000 0.000000 0.004656 21490.0 0.004650 0.000142 0.000000 0.000000 0.004650 21495.0 0.004644 0.000165 0.000000 0.000000 0.004644 21500.0 0.004636 0.000181 0.000000 0.000000 0.004636 21505.0 0.004629 0.000188 0.000000 0.000000 0.004629 21510.0 0.004623 0.000184 0.000000 0.000000 0.004623 21515.0 0.004618 0.000168 0.000000 0.000000 0.004618 21520.0 0.004614 0.000141 0.000000 0.000000 0.004614 21525.0 0.004611 0.000106 0.000000 0.000000 0.004611 21530.0 0.004607 0.000069 0.000000 0.000000 0.004607 21535.0 0.004603 0.000050 0.000000 0.000000 0.004603 21540.0 0.004599 0.000058 0.000000 0.000000 0.004599 21545.0 0.004595 0.000085 0.000000 0.000000 0.004595 21550.0 0.004591 0.000118 0.000000 0.000000 0.004591 21555.0 0.004585 0.000141 0.000000 0.000000 0.004585 21560.0 0.004576 0.000148 0.000000 0.000000 0.004576 21565.0 0.004564 0.000143 0.000000 0.000000 0.004564 21570.0 0.004551 0.000129 0.000000 0.000000 0.004551 21575.0 0.004537 0.000114 0.000000 0.000000 0.004537 21580.0 0.004522 0.000105 0.000000 0.000000 0.004522 21585.0 0.004509 0.000107 0.000000 0.000000 0.004509 21590.0 0.004498 0.000115 0.000000 0.000000 0.004498 21595.0 0.004491 0.000123 0.000000 0.000000 0.004491 21600.0 0.004487 0.000126 0.000000 0.000000 0.004487 21605.0 0.004487 0.000121 0.000000 0.000000 0.004487 21610.0 0.004490 0.000110 0.000000 0.000000 0.004490 21615.0 0.004493 0.000093 0.000000 0.000000 0.004493 21620.0 0.004496 0.000068 0.000000 0.000000 0.004496 21625.0 0.004497 0.000040 0.000000 0.000000 0.004497 21630.0 0.004495 0.000019 0.000000 0.000000 0.004495 21635.0 0.004489 0.000013 0.000000 0.000000 0.004489 21640.0 0.004480 0.000024 0.000000 0.000000 0.004480 21645.0 0.004466 0.000038 0.000000 0.000000 0.004466 21650.0 0.004449 0.000043 0.000000 0.000000 0.004449 21655.0 0.004430 0.000045 0.000000 0.000000 0.004430 21660.0 0.004409 0.000054 0.000000 0.000000 0.004409 21665.0 0.004389 0.000071 0.000000 0.000000 0.004389 21670.0 0.004370 0.000094 0.000000 0.000000 0.004370 21675.0 0.004355 0.000120 0.000000 0.000000 0.004355 21680.0 0.004345 0.000144 0.000000 0.000000 0.004345 21685.0 0.004344 0.000159 0.000000 0.000000 0.004344 21690.0 0.004352 0.000162 0.000000 0.000000 0.004352 21695.0 0.004367 0.000160 0.000000 0.000000 0.004367 21700.0 0.004388 0.000154 0.000000 0.000000 0.004388 21705.0 0.004413 0.000144 0.000000 0.000000 0.004413 21710.0 0.004440 0.000135 0.000000 0.000000 0.004440 21715.0 0.004467 0.000129 0.000000 0.000000 0.004467 21720.0 0.004491 0.000125 0.000000 0.000000 0.004491 21725.0 0.004507 0.000122 0.000000 0.000000 0.004507 21730.0 0.004515 0.000115 0.000000 0.000000 0.004515 21735.0 0.004512 0.000103 0.000000 0.000000 0.004512 21740.0 0.004499 0.000083 0.000000 0.000000 0.004499 21745.0 0.004477 0.000057 0.000000 0.000000 0.004477 21750.0 0.004448 0.000037 0.000000 0.000000 0.004448 21755.0 0.004414 0.000033 0.000000 0.000000 0.004414 21760.0 0.004373 0.000054 0.000000 0.000000 0.004373 21765.0 0.004327 0.000095 0.000000 0.000000 0.004327 21770.0 0.004284 0.000133 0.000000 0.000000 0.004284 21775.0 0.004250 0.000157 0.000000 0.000000 0.004250 21780.0 0.004227 0.000168 0.000000 0.000000 0.004227 21785.0 0.004218 0.000164 0.000000 0.000000 0.004218 21790.0 0.004223 0.000145 0.000000 0.000000 0.004223 21795.0 0.004244 0.000117 0.000000 0.000000 0.004244 21800.0 0.004278 0.000092 0.000000 0.000000 0.004278 21805.0 0.004322 0.000089 0.000000 0.000000 0.004322 21810.0 0.004375 0.000120 0.000000 0.000000 0.004375 21815.0 0.004431 0.000170 0.000000 0.000000 0.004431 21820.0 0.004484 0.000215 0.000000 0.000000 0.004484 21825.0 0.004532 0.000249 0.000000 0.000000 0.004532 21830.0 0.004570 0.000269 0.000000 0.000000 0.004570 21835.0 0.004596 0.000272 0.000000 0.000000 0.004596 21840.0 0.004608 0.000257 0.000000 0.000000 0.004608 21845.0 0.004604 0.000227 0.000000 0.000000 0.004604 21850.0 0.004587 0.000184 0.000000 0.000000 0.004587 21855.0 0.004558 0.000130 0.000000 0.000000 0.004558 21860.0 0.004520 0.000074 0.000000 0.000000 0.004520 21865.0 0.004477 0.000045 0.000000 0.000000 0.004477 21870.0 0.004434 0.000048 0.000000 0.000000 0.004434 21875.0 0.004393 0.000069 0.000000 0.000000 0.004393 21880.0 0.004357 0.000091 0.000000 0.000000 0.004357 21885.0 0.004330 0.000102 0.000000 0.000000 0.004330 21890.0 0.004311 0.000103 0.000000 0.000000 0.004311 21895.0 0.004303 0.000101 0.000000 0.000000 0.004303 21900.0 0.004302 0.000104 0.000000 0.000000 0.004302 21905.0 0.004309 0.000118 0.000000 0.000000 0.004309 21910.0 0.004321 0.000139 0.000000 0.000000 0.004321 21915.0 0.004335 0.000160 0.000000 0.000000 0.004335 21920.0 0.004347 0.000177 0.000000 0.000000 0.004347 21925.0 0.004357 0.000184 0.000000 0.000000 0.004357 21930.0 0.004361 0.000182 0.000000 0.000000 0.004361 21935.0 0.004361 0.000172 0.000000 0.000000 0.004361 21940.0 0.004354 0.000158 0.000000 0.000000 0.004354 21945.0 0.004340 0.000145 0.000000 0.000000 0.004340 21950.0 0.004321 0.000141 0.000000 0.000000 0.004321 21955.0 0.004301 0.000149 0.000000 0.000000 0.004301 21960.0 0.004281 0.000163 0.000000 0.000000 0.004281 21965.0 0.004263 0.000175 0.000000 0.000000 0.004263 21970.0 0.004249 0.000179 0.000000 0.000000 0.004249 21975.0 0.004241 0.000172 0.000000 0.000000 0.004241 21980.0 0.004240 0.000151 0.000000 0.000000 0.004240 21985.0 0.004246 0.000118 0.000000 0.000000 0.004246 21990.0 0.004259 0.000081 0.000000 0.000000 0.004259 21995.0 0.004278 0.000058 0.000000 0.000000 0.004278 22000.0 0.004301 0.000074 0.000000 0.000000 0.004301 22005.0 0.004325 0.000123 0.000000 0.000000 0.004325 22010.0 0.004349 0.000173 0.000000 0.000000 0.004349 22015.0 0.004369 0.000210 0.000000 0.000000 0.004369 22020.0 0.004383 0.000233 0.000000 0.000000 0.004383 22025.0 0.004389 0.000242 0.000000 0.000000 0.004389 22030.0 0.004387 0.000236 0.000000 0.000000 0.004387 22035.0 0.004378 0.000217 0.000000 0.000000 0.004378 22040.0 0.004361 0.000189 0.000000 0.000000 0.004361 22045.0 0.004340 0.000160 0.000000 0.000000 0.004340 22050.0 0.004317 0.000135 0.000000 0.000000 0.004317 22055.0 0.004293 0.000116 0.000000 0.000000 0.004293 22060.0 0.004272 0.000106 0.000000 0.000000 0.004272 22065.0 0.004254 0.000097 0.000000 0.000000 0.004254 22070.0 0.004242 0.000082 0.000000 0.000000 0.004242 22075.0 0.004237 0.000058 0.000000 0.000000 0.004237 22080.0 0.004238 0.000032 0.000000 0.000000 0.004238 22085.0 0.004246 0.000030 0.000000 0.000000 0.004246 22090.0 0.004259 0.000075 0.000000 0.000000 0.004259 22095.0 0.004276 0.000141 0.000000 0.000000 0.004276 22100.0 0.004296 0.000201 0.000000 0.000000 0.004296 22105.0 0.004315 0.000251 0.000000 0.000000 0.004315 22110.0 0.004331 0.000293 0.000000 0.000000 0.004331 22115.0 0.004343 0.000323 0.000000 0.000000 0.004343 22120.0 0.004349 0.000336 0.000000 0.000000 0.004349 22125.0 0.004348 0.000331 0.000000 0.000000 0.004348 22130.0 0.004340 0.000309 0.000000 0.000000 0.004340 22135.0 0.004326 0.000274 0.000000 0.000000 0.004326 22140.0 0.004306 0.000228 0.000000 0.000000 0.004306 22145.0 0.004281 0.000171 0.000000 0.000000 0.004281 22150.0 0.004254 0.000113 0.000000 0.000000 0.004254 22155.0 0.004226 0.000073 0.000000 0.000000 0.004226 22160.0 0.004198 0.000063 0.000000 0.000000 0.004198 22165.0 0.004173 0.000080 0.000000 0.000000 0.004173 22170.0 0.004150 0.000112 0.000000 0.000000 0.004150 22175.0 0.004131 0.000139 0.000000 0.000000 0.004131 22180.0 0.004116 0.000152 0.000000 0.000000 0.004116 22185.0 0.004105 0.000154 0.000000 0.000000 0.004105 22190.0 0.004098 0.000147 0.000000 0.000000 0.004098 22195.0 0.004093 0.000133 0.000000 0.000000 0.004093 22200.0 0.004089 0.000117 0.000000 0.000000 0.004089 22205.0 0.004086 0.000105 0.000000 0.000000 0.004086 22210.0 0.004083 0.000103 0.000000 0.000000 0.004083 22215.0 0.004079 0.000113 0.000000 0.000000 0.004079 22220.0 0.004073 0.000133 0.000000 0.000000 0.004073 22225.0 0.004065 0.000156 0.000000 0.000000 0.004065 22230.0 0.004056 0.000178 0.000000 0.000000 0.004056 22235.0 0.004046 0.000197 0.000000 0.000000 0.004046 22240.0 0.004036 0.000210 0.000000 0.000000 0.004036 22245.0 0.004028 0.000217 0.000000 0.000000 0.004028 22250.0 0.004022 0.000216 0.000000 0.000000 0.004022 22255.0 0.004019 0.000208 0.000000 0.000000 0.004019 22260.0 0.004021 0.000192 0.000000 0.000000 0.004021 22265.0 0.004027 0.000170 0.000000 0.000000 0.004027 22270.0 0.004037 0.000144 0.000000 0.000000 0.004037 22275.0 0.004051 0.000117 0.000000 0.000000 0.004051 22280.0 0.004068 0.000097 0.000000 0.000000 0.004068 22285.0 0.004087 0.000090 0.000000 0.000000 0.004087 22290.0 0.004105 0.000095 0.000000 0.000000 0.004105 22295.0 0.004121 0.000105 0.000000 0.000000 0.004121 22300.0 0.004132 0.000113 0.000000 0.000000 0.004132 22305.0 0.004139 0.000113 0.000000 0.000000 0.004139 22310.0 0.004138 0.000103 0.000000 0.000000 0.004138 22315.0 0.004130 0.000079 0.000000 0.000000 0.004130 22320.0 0.004114 0.000056 0.000000 0.000000 0.004114 22325.0 0.004092 0.000059 0.000000 0.000000 0.004092 22330.0 0.004064 0.000088 0.000000 0.000000 0.004064 22335.0 0.004031 0.000133 0.000000 0.000000 0.004031 22340.0 0.003996 0.000184 0.000000 0.000000 0.003996 22345.0 0.003962 0.000230 0.000000 0.000000 0.003962 22350.0 0.003930 0.000266 0.000000 0.000000 0.003930 22355.0 0.003902 0.000289 0.000000 0.000000 0.003902 22360.0 0.003882 0.000296 0.000000 0.000000 0.003882 22365.0 0.003870 0.000285 0.000000 0.000000 0.003870 22370.0 0.003869 0.000257 0.000000 0.000000 0.003869 22375.0 0.003877 0.000210 0.000000 0.000000 0.003877 22380.0 0.003896 0.000151 0.000000 0.000000 0.003896 22385.0 0.003923 0.000088 0.000000 0.000000 0.003923 22390.0 0.003957 0.000056 0.000000 0.000000 0.003957 22395.0 0.003997 0.000093 0.000000 0.000000 0.003997 22400.0 0.004038 0.000177 0.000000 0.000000 0.004038 22405.0 0.004078 0.000255 0.000000 0.000000 0.004078 22410.0 0.004115 0.000311 0.000000 0.000000 0.004115 22415.0 0.004145 0.000351 0.000000 0.000000 0.004145 22420.0 0.004167 0.000376 0.000000 0.000000 0.004167 22425.0 0.004179 0.000382 0.000000 0.000000 0.004179 22430.0 0.004181 0.000368 0.000000 0.000000 0.004181 22435.0 0.004172 0.000339 0.000000 0.000000 0.004172 22440.0 0.004153 0.000297 0.000000 0.000000 0.004153 22445.0 0.004126 0.000248 0.000000 0.000000 0.004126 22450.0 0.004092 0.000203 0.000000 0.000000 0.004092 22455.0 0.004054 0.000176 0.000000 0.000000 0.004054 22460.0 0.004014 0.000171 0.000000 0.000000 0.004014 22465.0 0.003974 0.000188 0.000000 0.000000 0.003974 22470.0 0.003936 0.000215 0.000000 0.000000 0.003936 22475.0 0.003905 0.000235 0.000000 0.000000 0.003905 22480.0 0.003883 0.000240 0.000000 0.000000 0.003883 22485.0 0.003867 0.000232 0.000000 0.000000 0.003867 22490.0 0.003858 0.000214 0.000000 0.000000 0.003858 22495.0 0.003857 0.000184 0.000000 0.000000 0.003857 22500.0 0.003863 0.000147 0.000000 0.000000 0.003863 22505.0 0.003874 0.000108 0.000000 0.000000 0.003874 22510.0 0.003889 0.000081 0.000000 0.000000 0.003889 22515.0 0.003904 0.000079 0.000000 0.000000 0.003904 22520.0 0.003919 0.000099 0.000000 0.000000 0.003919 22525.0 0.003932 0.000123 0.000000 0.000000 0.003932 22530.0 0.003940 0.000140 0.000000 0.000000 0.003940 22535.0 0.003944 0.000146 0.000000 0.000000 0.003944 22540.0 0.003942 0.000140 0.000000 0.000000 0.003942 22545.0 0.003934 0.000121 0.000000 0.000000 0.003934 22550.0 0.003922 0.000093 0.000000 0.000000 0.003922 22555.0 0.003905 0.000062 0.000000 0.000000 0.003905 22560.0 0.003886 0.000042 0.000000 0.000000 0.003886 22565.0 0.003866 0.000050 0.000000 0.000000 0.003866 22570.0 0.003847 0.000086 0.000000 0.000000 0.003847 22575.0 0.003830 0.000126 0.000000 0.000000 0.003830 22580.0 0.003817 0.000155 0.000000 0.000000 0.003817 22585.0 0.003808 0.000173 0.000000 0.000000 0.003808 22590.0 0.003804 0.000184 0.000000 0.000000 0.003804 22595.0 0.003806 0.000186 0.000000 0.000000 0.003806 22600.0 0.003813 0.000181 0.000000 0.000000 0.003813 22605.0 0.003823 0.000172 0.000000 0.000000 0.003823 22610.0 0.003837 0.000164 0.000000 0.000000 0.003837 22615.0 0.003851 0.000160 0.000000 0.000000 0.003851 22620.0 0.003866 0.000161 0.000000 0.000000 0.003866 22625.0 0.003879 0.000167 0.000000 0.000000 0.003879 22630.0 0.003889 0.000175 0.000000 0.000000 0.003889 22635.0 0.003895 0.000181 0.000000 0.000000 0.003895 22640.0 0.003896 0.000182 0.000000 0.000000 0.003896 22645.0 0.003892 0.000178 0.000000 0.000000 0.003892 22650.0 0.003882 0.000169 0.000000 0.000000 0.003882 22655.0 0.003868 0.000156 0.000000 0.000000 0.003868 22660.0 0.003850 0.000142 0.000000 0.000000 0.003850 22665.0 0.003830 0.000130 0.000000 0.000000 0.003830 22670.0 0.003808 0.000123 0.000000 0.000000 0.003808 22675.0 0.003788 0.000120 0.000000 0.000000 0.003788 22680.0 0.003769 0.000119 0.000000 0.000000 0.003769 22685.0 0.003753 0.000118 0.000000 0.000000 0.003753 22690.0 0.003742 0.000113 0.000000 0.000000 0.003742 22695.0 0.003736 0.000100 0.000000 0.000000 0.003736 22700.0 0.003735 0.000078 0.000000 0.000000 0.003735 22705.0 0.003738 0.000055 0.000000 0.000000 0.003738 22710.0 0.003746 0.000042 0.000000 0.000000 0.003746 22715.0 0.003758 0.000048 0.000000 0.000000 0.003758 22720.0 0.003772 0.000074 0.000000 0.000000 0.003772 22725.0 0.003787 0.000112 0.000000 0.000000 0.003787 22730.0 0.003803 0.000149 0.000000 0.000000 0.003803 22735.0 0.003817 0.000178 0.000000 0.000000 0.003817 22740.0 0.003830 0.000201 0.000000 0.000000 0.003830 22745.0 0.003839 0.000216 0.000000 0.000000 0.003839 22750.0 0.003844 0.000218 0.000000 0.000000 0.003844 22755.0 0.003842 0.000206 0.000000 0.000000 0.003842 22760.0 0.003836 0.000184 0.000000 0.000000 0.003836 22765.0 0.003826 0.000157 0.000000 0.000000 0.003826 22770.0 0.003813 0.000126 0.000000 0.000000 0.003813 22775.0 0.003797 0.000095 0.000000 0.000000 0.003797 22780.0 0.003778 0.000080 0.000000 0.000000 0.003778 22785.0 0.003758 0.000088 0.000000 0.000000 0.003758 22790.0 0.003738 0.000109 0.000000 0.000000 0.003738 22795.0 0.003718 0.000135 0.000000 0.000000 0.003718 22800.0 0.003700 0.000159 0.000000 0.000000 0.003700 22805.0 0.003684 0.000174 0.000000 0.000000 0.003684 22810.0 0.003670 0.000181 0.000000 0.000000 0.003670 22815.0 0.003659 0.000177 0.000000 0.000000 0.003659 22820.0 0.003651 0.000165 0.000000 0.000000 0.003651 22825.0 0.003646 0.000145 0.000000 0.000000 0.003646 22830.0 0.003644 0.000116 0.000000 0.000000 0.003644 22835.0 0.003644 0.000075 0.000000 0.000000 0.003644 22840.0 0.003647 0.000039 0.000000 0.000000 0.003647 22845.0 0.003652 0.000029 0.000000 0.000000 0.003652 22850.0 0.003657 0.000043 0.000000 0.000000 0.003657 22855.0 0.003664 0.000070 0.000000 0.000000 0.003664 22860.0 0.003670 0.000098 0.000000 0.000000 0.003670 22865.0 0.003676 0.000119 0.000000 0.000000 0.003676 22870.0 0.003680 0.000129 0.000000 0.000000 0.003680 22875.0 0.003683 0.000129 0.000000 0.000000 0.003683 22880.0 0.003684 0.000122 0.000000 0.000000 0.003684 22885.0 0.003683 0.000106 0.000000 0.000000 0.003683 22890.0 0.003680 0.000088 0.000000 0.000000 0.003680 22895.0 0.003676 0.000080 0.000000 0.000000 0.003676 22900.0 0.003669 0.000089 0.000000 0.000000 0.003669 22905.0 0.003662 0.000114 0.000000 0.000000 0.003662 22910.0 0.003653 0.000150 0.000000 0.000000 0.003653 22915.0 0.003644 0.000191 0.000000 0.000000 0.003644 22920.0 0.003635 0.000230 0.000000 0.000000 0.003635 22925.0 0.003626 0.000265 0.000000 0.000000 0.003626 22930.0 0.003618 0.000294 0.000000 0.000000 0.003618 22935.0 0.003612 0.000315 0.000000 0.000000 0.003612 22940.0 0.003608 0.000328 0.000000 0.000000 0.003608 22945.0 0.003606 0.000331 0.000000 0.000000 0.003606 22950.0 0.003607 0.000324 0.000000 0.000000 0.003607 22955.0 0.003612 0.000308 0.000000 0.000000 0.003612 22960.0 0.003621 0.000284 0.000000 0.000000 0.003621 22965.0 0.003633 0.000254 0.000000 0.000000 0.003633 22970.0 0.003649 0.000220 0.000000 0.000000 0.003649 22975.0 0.003667 0.000186 0.000000 0.000000 0.003667 22980.0 0.003687 0.000158 0.000000 0.000000 0.003687 22985.0 0.003709 0.000141 0.000000 0.000000 0.003709 22990.0 0.003730 0.000139 0.000000 0.000000 0.003730 22995.0 0.003751 0.000150 0.000000 0.000000 0.003751 23000.0 0.003770 0.000168 0.000000 0.000000 0.003770 23005.0 0.003786 0.000188 0.000000 0.000000 0.003786 23010.0 0.003798 0.000206 0.000000 0.000000 0.003798 23015.0 0.003805 0.000219 0.000000 0.000000 0.003805 23020.0 0.003808 0.000228 0.000000 0.000000 0.003808 23025.0 0.003808 0.000233 0.000000 0.000000 0.003808 23030.0 0.003802 0.000233 0.000000 0.000000 0.003802 23035.0 0.003790 0.000227 0.000000 0.000000 0.003790 23040.0 0.003773 0.000219 0.000000 0.000000 0.003773 23045.0 0.003754 0.000210 0.000000 0.000000 0.003754 23050.0 0.003733 0.000201 0.000000 0.000000 0.003733 23055.0 0.003711 0.000193 0.000000 0.000000 0.003711 23060.0 0.003689 0.000186 0.000000 0.000000 0.003689 23065.0 0.003667 0.000180 0.000000 0.000000 0.003667 23070.0 0.003648 0.000176 0.000000 0.000000 0.003648 23075.0 0.003632 0.000173 0.000000 0.000000 0.003632 23080.0 0.003619 0.000170 0.000000 0.000000 0.003619 23085.0 0.003609 0.000167 0.000000 0.000000 0.003609 23090.0 0.003603 0.000164 0.000000 0.000000 0.003603 23095.0 0.003600 0.000161 0.000000 0.000000 0.003600 23100.0 0.003600 0.000158 0.000000 0.000000 0.003600 23105.0 0.003602 0.000155 0.000000 0.000000 0.003602 23110.0 0.003604 0.000152 0.000000 0.000000 0.003604 23115.0 0.003607 0.000150 0.000000 0.000000 0.003607 23120.0 0.003610 0.000149 0.000000 0.000000 0.003610 23125.0 0.003611 0.000148 0.000000 0.000000 0.003611 23130.0 0.003610 0.000148 0.000000 0.000000 0.003610 23135.0 0.003607 0.000149 0.000000 0.000000 0.003607 23140.0 0.003601 0.000151 0.000000 0.000000 0.003601 23145.0 0.003593 0.000154 0.000000 0.000000 0.003593 23150.0 0.003583 0.000157 0.000000 0.000000 0.003583 23155.0 0.003571 0.000160 0.000000 0.000000 0.003571 23160.0 0.003557 0.000163 0.000000 0.000000 0.003557 23165.0 0.003543 0.000166 0.000000 0.000000 0.003543 23170.0 0.003528 0.000168 0.000000 0.000000 0.003528 23175.0 0.003515 0.000170 0.000000 0.000000 0.003515 23180.0 0.003503 0.000171 0.000000 0.000000 0.003503 23185.0 0.003494 0.000171 0.000000 0.000000 0.003494 23190.0 0.003488 0.000170 0.000000 0.000000 0.003488 23195.0 0.003486 0.000168 0.000000 0.000000 0.003486 23200.0 0.003487 0.000166 0.000000 0.000000 0.003487 23205.0 0.003493 0.000164 0.000000 0.000000 0.003493 23210.0 0.003501 0.000161 0.000000 0.000000 0.003501 23215.0 0.003513 0.000158 0.000000 0.000000 0.003513 23220.0 0.003526 0.000154 0.000000 0.000000 0.003526 23225.0 0.003541 0.000150 0.000000 0.000000 0.003541 23230.0 0.003555 0.000145 0.000000 0.000000 0.003555 23235.0 0.003570 0.000140 0.000000 0.000000 0.003570 23240.0 0.003583 0.000135 0.000000 0.000000 0.003583 23245.0 0.003593 0.000128 0.000000 0.000000 0.003593 23250.0 0.003601 0.000121 0.000000 0.000000 0.003601 23255.0 0.003606 0.000113 0.000000 0.000000 0.003606 23260.0 0.003607 0.000104 0.000000 0.000000 0.003607 23265.0 0.003604 0.000095 0.000000 0.000000 0.003604 23270.0 0.003597 0.000083 0.000000 0.000000 0.003597 23275.0 0.003586 0.000071 0.000000 0.000000 0.003586 23280.0 0.003572 0.000057 0.000000 0.000000 0.003572 23285.0 0.003555 0.000042 0.000000 0.000000 0.003555 23290.0 0.003537 0.000025 0.000000 0.000000 0.003537 23295.0 0.003517 0.000011 0.000000 0.000000 0.003517 23300.0 0.003497 0.000009 0.000000 0.000000 0.003497 23305.0 0.003478 0.000024 0.000000 0.000000 0.003478 23310.0 0.003461 0.000045 0.000000 0.000000 0.003461 23315.0 0.003445 0.000062 0.000000 0.000000 0.003445 23320.0 0.003433 0.000073 0.000000 0.000000 0.003433 23325.0 0.003427 0.000078 0.000000 0.000000 0.003427 23330.0 0.003425 0.000078 0.000000 0.000000 0.003425 23335.0 0.003426 0.000075 0.000000 0.000000 0.003426 23340.0 0.003431 0.000065 0.000000 0.000000 0.003431 23345.0 0.003438 0.000044 0.000000 0.000000 0.003438 23350.0 0.003450 0.000019 0.000000 0.000000 0.003450 23355.0 0.003463 0.000012 0.000000 0.000000 0.003463 23360.0 0.003478 0.000032 0.000000 0.000000 0.003478 23365.0 0.003494 0.000065 0.000000 0.000000 0.003494 23370.0 0.003509 0.000099 0.000000 0.000000 0.003509 23375.0 0.003524 0.000133 0.000000 0.000000 0.003524 23380.0 0.003537 0.000164 0.000000 0.000000 0.003537 23385.0 0.003546 0.000193 0.000000 0.000000 0.003546 23390.0 0.003553 0.000217 0.000000 0.000000 0.003553 23395.0 0.003555 0.000235 0.000000 0.000000 0.003555 23400.0 0.003554 0.000248 0.000000 0.000000 0.003554 23405.0 0.003548 0.000257 0.000000 0.000000 0.003548 23410.0 0.003538 0.000263 0.000000 0.000000 0.003538 23415.0 0.003526 0.000268 0.000000 0.000000 0.003526 23420.0 0.003510 0.000274 0.000000 0.000000 0.003510 23425.0 0.003494 0.000282 0.000000 0.000000 0.003494 23430.0 0.003477 0.000293 0.000000 0.000000 0.003477 23435.0 0.003460 0.000306 0.000000 0.000000 0.003460 23440.0 0.003444 0.000319 0.000000 0.000000 0.003444 23445.0 0.003430 0.000330 0.000000 0.000000 0.003430 23450.0 0.003418 0.000338 0.000000 0.000000 0.003418 23455.0 0.003407 0.000341 0.000000 0.000000 0.003407 23460.0 0.003399 0.000337 0.000000 0.000000 0.003399 23465.0 0.003393 0.000327 0.000000 0.000000 0.003393 23470.0 0.003388 0.000310 0.000000 0.000000 0.003388 23475.0 0.003385 0.000288 0.000000 0.000000 0.003385 23480.0 0.003383 0.000260 0.000000 0.000000 0.003383 23485.0 0.003381 0.000230 0.000000 0.000000 0.003381 23490.0 0.003379 0.000197 0.000000 0.000000 0.003379 23495.0 0.003376 0.000165 0.000000 0.000000 0.003376 23500.0 0.003373 0.000135 0.000000 0.000000 0.003373 23505.0 0.003368 0.000108 0.000000 0.000000 0.003368 23510.0 0.003362 0.000087 0.000000 0.000000 0.003362 23515.0 0.003355 0.000074 0.000000 0.000000 0.003355 23520.0 0.003347 0.000071 0.000000 0.000000 0.003347 23525.0 0.003337 0.000078 0.000000 0.000000 0.003337 23530.0 0.003327 0.000091 0.000000 0.000000 0.003327 23535.0 0.003317 0.000108 0.000000 0.000000 0.003317 23540.0 0.003308 0.000125 0.000000 0.000000 0.003308 23545.0 0.003299 0.000141 0.000000 0.000000 0.003299 23550.0 0.003291 0.000156 0.000000 0.000000 0.003291 23555.0 0.003284 0.000168 0.000000 0.000000 0.003284 23560.0 0.003279 0.000177 0.000000 0.000000 0.003279 23565.0 0.003276 0.000183 0.000000 0.000000 0.003276 23570.0 0.003274 0.000185 0.000000 0.000000 0.003274 23575.0 0.003274 0.000185 0.000000 0.000000 0.003274 23580.0 0.003276 0.000185 0.000000 0.000000 0.003276 23585.0 0.003278 0.000184 0.000000 0.000000 0.003278 23590.0 0.003282 0.000186 0.000000 0.000000 0.003282 23595.0 0.003286 0.000190 0.000000 0.000000 0.003286 23600.0 0.003290 0.000197 0.000000 0.000000 0.003290 23605.0 0.003294 0.000205 0.000000 0.000000 0.003294 23610.0 0.003299 0.000213 0.000000 0.000000 0.003299 23615.0 0.003303 0.000220 0.000000 0.000000 0.003303 23620.0 0.003307 0.000223 0.000000 0.000000 0.003307 23625.0 0.003312 0.000221 0.000000 0.000000 0.003312 23630.0 0.003317 0.000214 0.000000 0.000000 0.003317 23635.0 0.003324 0.000205 0.000000 0.000000 0.003324 23640.0 0.003331 0.000193 0.000000 0.000000 0.003331 23645.0 0.003339 0.000180 0.000000 0.000000 0.003339 23650.0 0.003348 0.000167 0.000000 0.000000 0.003348 23655.0 0.003359 0.000154 0.000000 0.000000 0.003359 23660.0 0.003370 0.000144 0.000000 0.000000 0.003370 23665.0 0.003381 0.000135 0.000000 0.000000 0.003381 23670.0 0.003393 0.000130 0.000000 0.000000 0.003393 23675.0 0.003404 0.000126 0.000000 0.000000 0.003404 23680.0 0.003415 0.000124 0.000000 0.000000 0.003415 23685.0 0.003424 0.000126 0.000000 0.000000 0.003424 23690.0 0.003430 0.000131 0.000000 0.000000 0.003430 23695.0 0.003434 0.000141 0.000000 0.000000 0.003434 23700.0 0.003435 0.000155 0.000000 0.000000 0.003435 23705.0 0.003432 0.000173 0.000000 0.000000 0.003432 23710.0 0.003424 0.000193 0.000000 0.000000 0.003424 23715.0 0.003412 0.000212 0.000000 0.000000 0.003412 23720.0 0.003395 0.000229 0.000000 0.000000 0.003395 23725.0 0.003373 0.000243 0.000000 0.000000 0.003373 23730.0 0.003349 0.000252 0.000000 0.000000 0.003349 23735.0 0.003322 0.000257 0.000000 0.000000 0.003322 23740.0 0.003294 0.000258 0.000000 0.000000 0.003294 23745.0 0.003267 0.000257 0.000000 0.000000 0.003267 23750.0 0.003242 0.000253 0.000000 0.000000 0.003242 23755.0 0.003221 0.000249 0.000000 0.000000 0.003221 23760.0 0.003202 0.000244 0.000000 0.000000 0.003202 23765.0 0.003188 0.000240 0.000000 0.000000 0.003188 23770.0 0.003179 0.000235 0.000000 0.000000 0.003179 23775.0 0.003173 0.000231 0.000000 0.000000 0.003173 23780.0 0.003172 0.000227 0.000000 0.000000 0.003172 23785.0 0.003173 0.000223 0.000000 0.000000 0.003173 23790.0 0.003176 0.000218 0.000000 0.000000 0.003176 23795.0 0.003181 0.000213 0.000000 0.000000 0.003181 23800.0 0.003186 0.000207 0.000000 0.000000 0.003186 23805.0 0.003191 0.000201 0.000000 0.000000 0.003191 23810.0 0.003195 0.000194 0.000000 0.000000 0.003195 23815.0 0.003198 0.000188 0.000000 0.000000 0.003198 23820.0 0.003199 0.000182 0.000000 0.000000 0.003199 23825.0 0.003199 0.000176 0.000000 0.000000 0.003199 23830.0 0.003196 0.000171 0.000000 0.000000 0.003196 23835.0 0.003192 0.000167 0.000000 0.000000 0.003192 23840.0 0.003187 0.000165 0.000000 0.000000 0.003187 23845.0 0.003181 0.000163 0.000000 0.000000 0.003181 23850.0 0.003175 0.000163 0.000000 0.000000 0.003175 23855.0 0.003169 0.000163 0.000000 0.000000 0.003169 23860.0 0.003164 0.000166 0.000000 0.000000 0.003164 23865.0 0.003160 0.000169 0.000000 0.000000 0.003160 23870.0 0.003158 0.000172 0.000000 0.000000 0.003158 23875.0 0.003157 0.000177 0.000000 0.000000 0.003157 23880.0 0.003158 0.000180 0.000000 0.000000 0.003158 23885.0 0.003160 0.000184 0.000000 0.000000 0.003160 23890.0 0.003163 0.000186 0.000000 0.000000 0.003163 23895.0 0.003166 0.000187 0.000000 0.000000 0.003166 23900.0 0.003170 0.000186 0.000000 0.000000 0.003170 23905.0 0.003173 0.000185 0.000000 0.000000 0.003173 23910.0 0.003174 0.000182 0.000000 0.000000 0.003174 23915.0 0.003175 0.000178 0.000000 0.000000 0.003175 23920.0 0.003174 0.000174 0.000000 0.000000 0.003174 23925.0 0.003170 0.000169 0.000000 0.000000 0.003170 23930.0 0.003163 0.000164 0.000000 0.000000 0.003163 23935.0 0.003155 0.000159 0.000000 0.000000 0.003155 23940.0 0.003146 0.000154 0.000000 0.000000 0.003146 23945.0 0.003137 0.000151 0.000000 0.000000 0.003137 23950.0 0.003128 0.000149 0.000000 0.000000 0.003128 23955.0 0.003121 0.000148 0.000000 0.000000 0.003121 23960.0 0.003116 0.000150 0.000000 0.000000 0.003116 23965.0 0.003114 0.000153 0.000000 0.000000 0.003114 23970.0 0.003116 0.000157 0.000000 0.000000 0.003116 23975.0 0.003121 0.000163 0.000000 0.000000 0.003121 23980.0 0.003131 0.000170 0.000000 0.000000 0.003131 23985.0 0.003144 0.000177 0.000000 0.000000 0.003144 23990.0 0.003160 0.000184 0.000000 0.000000 0.003160 23995.0 0.003178 0.000191 0.000000 0.000000 0.003178 24000.0 0.003198 0.000196 0.000000 0.000000 0.003198 24005.0 0.003218 0.000201 0.000000 0.000000 0.003218 24010.0 0.003237 0.000205 0.000000 0.000000 0.003237 24015.0 0.003254 0.000207 0.000000 0.000000 0.003254 24020.0 0.003267 0.000208 0.000000 0.000000 0.003267 24025.0 0.003276 0.000207 0.000000 0.000000 0.003276 24030.0 0.003280 0.000205 0.000000 0.000000 0.003280 24035.0 0.003278 0.000202 0.000000 0.000000 0.003278 24040.0 0.003271 0.000197 0.000000 0.000000 0.003271 24045.0 0.003258 0.000192 0.000000 0.000000 0.003258 24050.0 0.003240 0.000187 0.000000 0.000000 0.003240 24055.0 0.003218 0.000184 0.000000 0.000000 0.003218 24060.0 0.003194 0.000183 0.000000 0.000000 0.003194 24065.0 0.003170 0.000186 0.000000 0.000000 0.003170 24070.0 0.003145 0.000192 0.000000 0.000000 0.003145 24075.0 0.003123 0.000201 0.000000 0.000000 0.003123 24080.0 0.003105 0.000212 0.000000 0.000000 0.003105 24085.0 0.003091 0.000224 0.000000 0.000000 0.003091 24090.0 0.003083 0.000236 0.000000 0.000000 0.003083 24095.0 0.003081 0.000247 0.000000 0.000000 0.003081 24100.0 0.003084 0.000257 0.000000 0.000000 0.003084 24105.0 0.003092 0.000264 0.000000 0.000000 0.003092 24110.0 0.003105 0.000270 0.000000 0.000000 0.003105 24115.0 0.003121 0.000273 0.000000 0.000000 0.003121 24120.0 0.003139 0.000273 0.000000 0.000000 0.003139 24125.0 0.003158 0.000270 0.000000 0.000000 0.003158 24130.0 0.003176 0.000264 0.000000 0.000000 0.003176 24135.0 0.003191 0.000255 0.000000 0.000000 0.003191 24140.0 0.003202 0.000243 0.000000 0.000000 0.003202 24145.0 0.003208 0.000228 0.000000 0.000000 0.003208 24150.0 0.003208 0.000212 0.000000 0.000000 0.003208 24155.0 0.003202 0.000195 0.000000 0.000000 0.003202 24160.0 0.003189 0.000180 0.000000 0.000000 0.003189 24165.0 0.003171 0.000169 0.000000 0.000000 0.003171 24170.0 0.003149 0.000163 0.000000 0.000000 0.003149 24175.0 0.003123 0.000164 0.000000 0.000000 0.003123 24180.0 0.003095 0.000171 0.000000 0.000000 0.003095 24185.0 0.003067 0.000181 0.000000 0.000000 0.003067 24190.0 0.003040 0.000193 0.000000 0.000000 0.003040 24195.0 0.003017 0.000204 0.000000 0.000000 0.003017 24200.0 0.002998 0.000213 0.000000 0.000000 0.002998 24205.0 0.002984 0.000220 0.000000 0.000000 0.002984 24210.0 0.002977 0.000225 0.000000 0.000000 0.002977 24215.0 0.002976 0.000230 0.000000 0.000000 0.002976 24220.0 0.002982 0.000236 0.000000 0.000000 0.002982 24225.0 0.002993 0.000246 0.000000 0.000000 0.002993 24230.0 0.003008 0.000259 0.000000 0.000000 0.003008 24235.0 0.003027 0.000275 0.000000 0.000000 0.003027 24240.0 0.003049 0.000291 0.000000 0.000000 0.003049 24245.0 0.003071 0.000305 0.000000 0.000000 0.003071 24250.0 0.003093 0.000317 0.000000 0.000000 0.003093 24255.0 0.003112 0.000326 0.000000 0.000000 0.003112 24260.0 0.003127 0.000329 0.000000 0.000000 0.003127 24265.0 0.003137 0.000326 0.000000 0.000000 0.003137 24270.0 0.003143 0.000316 0.000000 0.000000 0.003143 24275.0 0.003144 0.000300 0.000000 0.000000 0.003144 24280.0 0.003139 0.000278 0.000000 0.000000 0.003139 24285.0 0.003130 0.000252 0.000000 0.000000 0.003130 24290.0 0.003116 0.000223 0.000000 0.000000 0.003116 24295.0 0.003100 0.000192 0.000000 0.000000 0.003100 24300.0 0.003081 0.000161 0.000000 0.000000 0.003081 24305.0 0.003062 0.000133 0.000000 0.000000 0.003062 24310.0 0.003043 0.000109 0.000000 0.000000 0.003043 24315.0 0.003025 0.000090 0.000000 0.000000 0.003025 24320.0 0.003010 0.000079 0.000000 0.000000 0.003010 24325.0 0.002998 0.000075 0.000000 0.000000 0.002998 24330.0 0.002991 0.000076 0.000000 0.000000 0.002991 24335.0 0.002988 0.000082 0.000000 0.000000 0.002988 24340.0 0.002991 0.000091 0.000000 0.000000 0.002991 24345.0 0.002998 0.000104 0.000000 0.000000 0.002998 24350.0 0.003009 0.000119 0.000000 0.000000 0.003009 24355.0 0.003022 0.000137 0.000000 0.000000 0.003022 24360.0 0.003038 0.000156 0.000000 0.000000 0.003038 24365.0 0.003053 0.000175 0.000000 0.000000 0.003053 24370.0 0.003068 0.000193 0.000000 0.000000 0.003068 24375.0 0.003080 0.000207 0.000000 0.000000 0.003080 24380.0 0.003089 0.000219 0.000000 0.000000 0.003089 24385.0 0.003094 0.000227 0.000000 0.000000 0.003094 24390.0 0.003095 0.000231 0.000000 0.000000 0.003095 24395.0 0.003092 0.000232 0.000000 0.000000 0.003092 24400.0 0.003084 0.000231 0.000000 0.000000 0.003084 24405.0 0.003074 0.000228 0.000000 0.000000 0.003074 24410.0 0.003060 0.000226 0.000000 0.000000 0.003060 24415.0 0.003044 0.000224 0.000000 0.000000 0.003044 24420.0 0.003026 0.000224 0.000000 0.000000 0.003026 24425.0 0.003007 0.000225 0.000000 0.000000 0.003007 24430.0 0.002989 0.000228 0.000000 0.000000 0.002989 24435.0 0.002970 0.000232 0.000000 0.000000 0.002970 24440.0 0.002953 0.000238 0.000000 0.000000 0.002953 24445.0 0.002938 0.000245 0.000000 0.000000 0.002938 24450.0 0.002925 0.000252 0.000000 0.000000 0.002925 24455.0 0.002915 0.000260 0.000000 0.000000 0.002915 24460.0 0.002908 0.000268 0.000000 0.000000 0.002908 24465.0 0.002904 0.000276 0.000000 0.000000 0.002904 24470.0 0.002904 0.000283 0.000000 0.000000 0.002904 24475.0 0.002907 0.000289 0.000000 0.000000 0.002907 24480.0 0.002913 0.000294 0.000000 0.000000 0.002913 24485.0 0.002922 0.000296 0.000000 0.000000 0.002922 24490.0 0.002932 0.000295 0.000000 0.000000 0.002932 24495.0 0.002943 0.000291 0.000000 0.000000 0.002943 24500.0 0.002955 0.000284 0.000000 0.000000 0.002955 24505.0 0.002966 0.000273 0.000000 0.000000 0.002966 24510.0 0.002977 0.000259 0.000000 0.000000 0.002977 24515.0 0.002988 0.000241 0.000000 0.000000 0.002988 24520.0 0.002997 0.000222 0.000000 0.000000 0.002997 24525.0 0.003006 0.000201 0.000000 0.000000 0.003006 24530.0 0.003013 0.000181 0.000000 0.000000 0.003013 24535.0 0.003020 0.000161 0.000000 0.000000 0.003020 24540.0 0.003026 0.000143 0.000000 0.000000 0.003026 24545.0 0.003031 0.000128 0.000000 0.000000 0.003031 24550.0 0.003036 0.000115 0.000000 0.000000 0.003036 24555.0 0.003040 0.000107 0.000000 0.000000 0.003040 24560.0 0.003044 0.000106 0.000000 0.000000 0.003044 24565.0 0.003046 0.000111 0.000000 0.000000 0.003046 24570.0 0.003048 0.000121 0.000000 0.000000 0.003048 24575.0 0.003049 0.000133 0.000000 0.000000 0.003049 24580.0 0.003050 0.000148 0.000000 0.000000 0.003050 24585.0 0.003050 0.000166 0.000000 0.000000 0.003050 24590.0 0.003049 0.000185 0.000000 0.000000 0.003049 24595.0 0.003047 0.000205 0.000000 0.000000 0.003047 24600.0 0.003045 0.000225 0.000000 0.000000 0.003045 24605.0 0.003043 0.000244 0.000000 0.000000 0.003043 24610.0 0.003040 0.000262 0.000000 0.000000 0.003040 24615.0 0.003037 0.000278 0.000000 0.000000 0.003037 24620.0 0.003034 0.000291 0.000000 0.000000 0.003034 24625.0 0.003031 0.000302 0.000000 0.000000 0.003031 24630.0 0.003029 0.000309 0.000000 0.000000 0.003029 24635.0 0.003027 0.000314 0.000000 0.000000 0.003027 24640.0 0.003025 0.000315 0.000000 0.000000 0.003025 24645.0 0.003024 0.000314 0.000000 0.000000 0.003024 24650.0 0.003023 0.000310 0.000000 0.000000 0.003023 24655.0 0.003022 0.000304 0.000000 0.000000 0.003022 24660.0 0.003022 0.000297 0.000000 0.000000 0.003022 24665.0 0.003021 0.000289 0.000000 0.000000 0.003021 24670.0 0.003020 0.000281 0.000000 0.000000 0.003020 24675.0 0.003018 0.000273 0.000000 0.000000 0.003018 24680.0 0.003015 0.000265 0.000000 0.000000 0.003015 24685.0 0.003010 0.000258 0.000000 0.000000 0.003010 24690.0 0.003005 0.000252 0.000000 0.000000 0.003005 24695.0 0.002998 0.000247 0.000000 0.000000 0.002998 24700.0 0.002989 0.000244 0.000000 0.000000 0.002989 24705.0 0.002979 0.000242 0.000000 0.000000 0.002979 24710.0 0.002968 0.000242 0.000000 0.000000 0.002968 24715.0 0.002956 0.000244 0.000000 0.000000 0.002956 24720.0 0.002944 0.000248 0.000000 0.000000 0.002944 24725.0 0.002932 0.000255 0.000000 0.000000 0.002932 24730.0 0.002921 0.000265 0.000000 0.000000 0.002921 24735.0 0.002911 0.000277 0.000000 0.000000 0.002911 24740.0 0.002903 0.000290 0.000000 0.000000 0.002903 24745.0 0.002897 0.000304 0.000000 0.000000 0.002897 24750.0 0.002894 0.000318 0.000000 0.000000 0.002894 24755.0 0.002893 0.000331 0.000000 0.000000 0.002893 24760.0 0.002895 0.000343 0.000000 0.000000 0.002895 24765.0 0.002899 0.000354 0.000000 0.000000 0.002899 24770.0 0.002906 0.000363 0.000000 0.000000 0.002906 24775.0 0.002913 0.000370 0.000000 0.000000 0.002913 24780.0 0.002922 0.000375 0.000000 0.000000 0.002922 24785.0 0.002932 0.000379 0.000000 0.000000 0.002932 24790.0 0.002941 0.000380 0.000000 0.000000 0.002941 24795.0 0.002949 0.000378 0.000000 0.000000 0.002949 24800.0 0.002956 0.000374 0.000000 0.000000 0.002956 24805.0 0.002961 0.000367 0.000000 0.000000 0.002961 24810.0 0.002963 0.000357 0.000000 0.000000 0.002963 24815.0 0.002961 0.000343 0.000000 0.000000 0.002961 24820.0 0.002957 0.000327 0.000000 0.000000 0.002957 24825.0 0.002949 0.000308 0.000000 0.000000 0.002949 24830.0 0.002938 0.000287 0.000000 0.000000 0.002938 24835.0 0.002924 0.000265 0.000000 0.000000 0.002924 24840.0 0.002908 0.000246 0.000000 0.000000 0.002908 24845.0 0.002891 0.000229 0.000000 0.000000 0.002891 24850.0 0.002873 0.000217 0.000000 0.000000 0.002873 24855.0 0.002856 0.000211 0.000000 0.000000 0.002856 24860.0 0.002841 0.000210 0.000000 0.000000 0.002841 24865.0 0.002828 0.000213 0.000000 0.000000 0.002828 24870.0 0.002818 0.000217 0.000000 0.000000 0.002818 24875.0 0.002811 0.000222 0.000000 0.000000 0.002811 24880.0 0.002808 0.000226 0.000000 0.000000 0.002808 24885.0 0.002808 0.000228 0.000000 0.000000 0.002808 24890.0 0.002813 0.000227 0.000000 0.000000 0.002813 24895.0 0.002822 0.000223 0.000000 0.000000 0.002822 24900.0 0.002834 0.000219 0.000000 0.000000 0.002834 24905.0 0.002847 0.000218 0.000000 0.000000 0.002847 24910.0 0.002860 0.000218 0.000000 0.000000 0.002860 24915.0 0.002873 0.000222 0.000000 0.000000 0.002873 24920.0 0.002886 0.000229 0.000000 0.000000 0.002886 24925.0 0.002896 0.000237 0.000000 0.000000 0.002896 24930.0 0.002904 0.000246 0.000000 0.000000 0.002904 24935.0 0.002908 0.000255 0.000000 0.000000 0.002908 24940.0 0.002910 0.000263 0.000000 0.000000 0.002910 24945.0 0.002908 0.000268 0.000000 0.000000 0.002908 24950.0 0.002900 0.000271 0.000000 0.000000 0.002900 24955.0 0.002887 0.000271 0.000000 0.000000 0.002887 24960.0 0.002875 0.000271 0.000000 0.000000 0.002875 24965.0 0.002874 0.000272 0.000000 0.000000 0.002874 24970.0 0.002872 0.000274 0.000000 0.000000 0.002872 24975.0 0.002840 0.000271 0.000000 0.000000 0.002840 24980.0 0.002750 0.000277 0.000000 0.000000 0.002750 24985.0 0.002598 0.000364 0.000000 0.000000 0.002598 24990.0 0.000000 0.000620 0.000000 0.000000 0.000000 24995.0 0.000000 0.001047 0.000000 0.000000 0.000000 25000.0 0.000000 0.001561 0.000000 0.000000 0.000000