Filter shifts
On October 9, 2005 CONICA images have been taken with the pinhole array & different filters with and without neutral density. These data can be retrieved from here. They are meant to help estimating the astrometric shift existing between the different filters.
Table of data taken
All data have been taken with the S27 camera.
Detailled list of settings here
Some results
The following provides the centroid position for 5 selected holes for each filter measured, as well as the corresponding light intensity.
With the exception of the data taken with different lamp settings (see above table) for J, H, Ks, all data have been taken with a constant lamp setting aiming at getting an idea of the 'spectral effect' of the neutral density. For this purpose, frames with the same settings but with the lamp off have been taken (to remove the thermal effect related to the filter and not to the lamp).
- 'Pinhole_H_Full2_S27.fits'
DET DIT = 0.3500000 DET.NDIT = 10
| X | Y | FLUX |
| 254.397 | 799.133 | 5925.50 |
| 511.720 | 547.032 | 5974.40 |
| 767.955 | 294.894 | 5512.50 |
| 763.619 | 803.765 | 5743.50 |
| 259.169 | 290.161 | 6454.70 |
|
|
- 'Pinhole_H_Full_S27.fits'
Different lamp settings
DET DIT = 1.0000000 DET.NDIT = 5
| X | Y | FLUX |
| 254.330 | 799.152 | 1191.00 |
| 511.651 | 547.049 | 1176.80 |
| 767.885 | 294.914 | 1085.40 |
| 763.537 | 803.776 | 1124.80 |
| 259.107 | 290.182 | 1293.80 |
|
- 'Pinhole_H_NDS2_S27.fits'
DET DIT = 5.0000000 DET.NDIT = 2
| X | Y | FLUX |
| 254.934 | 799.116 | 1134.00 |
| 511.725 | 547.021 | 1136.50 |
| 767.955 | 294.900 | 1059.00 |
| 763.634 | 803.225 | 1093.50 |
| 259.717 | 290.166 | 1226.00 |
|
|
- 'Pinhole_H_NDS_S27.fits'
Different lamp settings
DET DIT = 60.0000000 DET.NDIT = 1
| X | Y | FLUX |
| 254.345 | 799.151 | 883.000 |
| 511.651 | 547.052 | 886.000 |
| 767.907 | 294.397 | 820.000 |
| 763.025 | 803.258 | 857.000 |
| 259.646 | 290.737 | 960.000 |
|
|
- 'Pinhole_J_Full2_S27.fits'
DET DIT = 0.3500000 DET.NDIT = 10
| X | Y | FLUX |
| 259.162 | 808.013 | 1806.50 |
| 516.177 | 555.150 | 1876.30 |
| 773.716 | 302.261 | 1739.10 |
| 768.847 | 812.102 | 1772.70 |
| 263.963 | 298.078 | 2066.80 |
|
|
- 'Pinhole_J_Full_S27.fits'
Different lamp settings
DET DIT = 10.0000000 DET.NDIT = 1
| X | Y | FLUX |
| 259.131 | 808.014 | 1545.00 |
| 516.136 | 555.161 | 1634.00 |
| 773.113 | 302.285 | 1482.00 |
| 768.239 | 812.101 | 1508.00 |
| 263.932 | 298.104 | 1766.00 |
|
- 'Pinhole_J_NDS2_S27.fits'
DET DIT = 10.0000000 DET.NDIT = 1
| X | Y | FLUX |
| 259.715 | 808.010 | 716.000 |
| 516.186 | 555.133 | 758.000 |
| 773.722 | 302.278 | 693.000 |
| 768.864 | 812.082 | 716.000 |
| 263.949 | 297.576 | 825.000 |
|
|
- 'Pinhole_J_NDS_S27.fits'
Different lamp settings
DET DIT = 120.0000000 DET.NDIT = 1
| X | Y | FLUX |
| 259.717 | 808.049 | 271.000 |
| 516.177 | 555.785 | 276.000 |
| 773.637 | 302.306 | 274.000 |
| 769.251 | 812.155 | 264.000 |
| 263.974 | 298.059 | 311.000 |
|
|
- 'Pinhole_K_Full2_S27.fits'
DET DIT = 0.3500000 DET.NDIT = 10
| X | Y | FLUX |
| 254.198 | 799.063 | 7131.00 |
| 510.340 | 547.061 | 7096.50 |
| 766.967 | 295.030 | 6377.10 |
| 762.126 | 803.700 | 6728.20 |
| 258.979 | 290.291 | 7447.90 |
|
|
- 'Pinhole_K_Full_S27.fits'
Different lamp settings
DET DIT = 1.0000000 DET.NDIT = 5
| X | Y | FLUX |
| 254.129 | 799.089 | 2198.60 |
| 510.257 | 547.085 | 2196.20 |
| 766.362 | 295.058 | 1959.80 |
| 762.050 | 803.721 | 2060.80 |
| 258.910 | 290.325 | 2285.80 |
|
- 'Pinhole_K_NDS2_S27.fits'
DET DIT = 5.0000000 DET.NDIT = 2
| X | Y | FLUX |
| 254.200 | 799.058 | 1230.00 |
| 510.346 | 547.049 | 1220.00 |
| 766.973 | 295.029 | 1095.50 |
| 762.136 | 803.699 | 1152.50 |
| 258.983 | 290.292 | 1290.50 |
|
|
- 'Pinhole_K_NDS_S27.fits'
Different lamp settings
DET DIT = 50.0000000 DET.NDIT = 1
| X | Y | FLUX |
| 254.128 | 799.094 | 1277.00 |
| 510.257 | 547.092 | 1266.00 |
| 766.884 | 295.037 | 1131.00 |
| 762.052 | 803.717 | 1199.00 |
| 258.377 | 290.849 | 1336.00 |
|
|
- 'Pinhole_NB104_Full_S27.fits'
DET DIT = 20.0000000 DET.NDIT = 1
| 253.748 | 799.528 | 1293.00 |
| 510.388 | 546.479 | 1337.00 |
| 768.079 | 294.439 | 1226.00 |
| 763.797 | 804.175 | 1299.00 |
| 257.974 | 289.169 | 1438.00 |
|
|
- 'Pinhole_NB104_NDS_S27.fits'
DET DIT = 120.0000000 DET.NDIT = 1
| 253.103 | 800.089 | 197.000 |
| 511.561 | 547.610 | 123.000 |
| 768.832 | 293.957 | 333.000 |
| 763.800 | 804.164 | 119.000 |
| 258.627 | 289.074 | 172.000 |
|
|
- 'Pinhole_NB109_Full_S27.fits'
DET DIT = 10.0000000 DET.NDIT = 1
| 253.894 | 799.444 | 1132.00 |
| 511.029 | 546.436 | 1125.00 |
| 768.675 | 293.922 | 1027.00 |
| 763.816 | 804.057 | 1121.00 |
| 258.164 | 289.208 | 1228.00 |
|
|
- 'Pinhole_NB109_NDS_S27.fits'
DET DIT = 120.0000000 DET.NDIT = 1
| 253.892 | 800.433 | 199.000 |
| 510.508 | 546.370 | 205.000 |
| 768.705 | 294.147 | 243.000 |
| 763.824 | 803.526 | 198.000 |
| 258.776 | 289.148 | 267.000 |
|
|
- 'Pinhole_NB124_Full_S27.fits'
DET DIT = 5.0000000 DET.NDIT = 1
| 254.114 | 799.333 | 1259.00 |
| 511.148 | 547.008 | 1259.00 |
| 768.153 | 294.667 | 1166.00 |
| 763.834 | 803.958 | 1245.00 |
| 258.922 | 289.392 | 1375.00 |
|
|
- 'Pinhole_NB124_NDS_S27.fits'
DET DIT = 120.0000000 DET.NDIT = 1
| 254.139 | 799.822 | 426.000 |
| 511.713 | 546.481 | 426.000 |
| 769.015 | 294.177 | 487.000 |
| 763.847 | 803.982 | 421.000 |
| 258.931 | 289.398 | 486.000 |
|
|
- 'Pinhole_NB128_Full_S27.fits'
DET DIT = 5.0000000 DET.NDIT = 1
| 254.248 | 799.200 | 1296.00 |
| 511.245 | 546.906 | 1329.00 |
| 768.197 | 294.025 | 1250.00 |
| 763.891 | 803.293 | 1304.00 |
| 258.496 | 289.271 | 1459.00 |
|
|
- 'Pinhole_NB128_NDS_S27.fits'
DET DIT = 120.0000000 DET.NDIT = 1
| 254.240 | 799.193 | 441.000 |
| 511.216 | 546.933 | 447.000 |
| 768.737 | 294.637 | 470.000 |
| 763.913 | 803.296 | 448.000 |
| 259.049 | 289.268 | 531.000 |
|
| |
- 'Pinhole_NB164_Full_S27.fits'
DET DIT = 2.0000000 DET.NDIT = 5
| 254.321 | 799.089 | 1101.60 |
| 511.674 | 546.936 | 1100.80 |
| 767.942 | 294.197 | 1002.20 |
| 763.601 | 803.179 | 1047.40 |
| 259.091 | 290.005 | 1189.20 |
|
|
- 'Pinhole_NB164_NDS_S27.fits'
DET DIT = 120.0000000 DET.NDIT = 1
| 254.332 | 799.078 | 833.000 |
| 511.159 | 546.930 | 829.000 |
| 767.949 | 294.220 | 763.000 |
| 763.087 | 803.214 | 807.000 |
| 259.114 | 289.495 | 918.000 |
|
|
- 'Pinhole_NB175_Full_S27.fits'
DET DIT = 1.0000000 DET.NDIT = 10
| 254.926 | 799.331 | 1228.60 |
| 511.720 | 547.237 | 1264.40 |
| 767.961 | 295.112 | 1140.80 |
| 763.631 | 803.958 | 1225.40 |
| 259.151 | 290.380 | 1307.20 |
|
|
- 'Pinhole_NB175_NDS_S27.fits'
DET DIT = 60.0000000 DET.NDIT = 1
| 254.944 | 799.859 | 920.000 |
| 511.717 | 547.773 | 945.000 |
| 767.978 | 295.120 | 857.000 |
| 763.633 | 803.960 | 908.000 |
| 259.685 | 290.916 | 980.000 |
|
|
- 'Pinhole_NB212_Full_S27.fits'
DET DIT = 1.0000000 DET.NDIT = 10
| 254.049 | 797.781 | 1163.30 |
| 510.184 | 545.809 | 1165.90 |
| 766.284 | 293.804 | 1034.80 |
| 761.975 | 801.883 | 1081.20 |
| 258.307 | 289.058 | 1220.70 |
|
|
- 'Pinhole_NB212_NDS_S27.fits'
DET DIT = 60.0000000 DET.NDIT = 1
| 254.061 | 797.798 | 799.000 |
| 510.189 | 545.292 | 794.000 |
| 766.294 | 293.287 | 722.000 |
| 761.983 | 801.379 | 750.000 |
| 258.856 | 289.065 | 855.000 |
|
|
- 'Pinhole_NB217_Full_S27.fits'
DET DIT = 1.0000000 DET.NDIT = 10
| 254.419 | 798.998 | 1059.20 |
| 511.074 | 546.996 | 1058.80 |
| 767.186 | 294.973 | 964.100 |
| 762.867 | 803.087 | 995.100 |
| 259.191 | 290.240 | 1133.60 |
|
|
- 'Pinhole_NB217_NDS_S27.fits'
DET DIT = 60.0000000 DET.NDIT = 1
| 254.433 | 798.995 | 720.000 |
| 511.073 | 547.009 | 726.000 |
| 767.183 | 294.971 | 656.000 |
| 762.872 | 803.098 | 683.000 |
| 259.729 | 290.775 | 785.000 |
|