# number of points on sci filter + aux + bad z = 13
# number of points on sci filter               = 13
# number of positions in lambda                = 301
# noof scans  1            1            1            1            1            1            1            1            1            1            1            1            1          
# x_pos       0.000000    17.670000   -17.670000   -17.670000    17.670000    35.340000   -35.340000   -35.340000    35.340000    53.010000   -53.010000   -53.010000    53.010000 
# y_pos       0.000000    17.670000    17.670000   -17.670000   -17.670000    35.340000    35.340000   -35.340000   -35.340000    53.010000    53.010000   -53.010000   -53.010000 
# angle       1.780000     2.230000     1.840000     1.320000     1.840000     2.690000     2.000000     0.870000     2.000000     3.140000     2.230000     0.410000     2.230000 
# z_pos      44.000000    47.000000    45.000000    43.000000    45.000000    48.000000    46.000000    42.000000    46.000000    49.000000    47.000000    41.000000    47.000000 
# r_pos       0.000000    24.990000    24.990000    24.990000    24.990000    49.980000    49.980000    49.980000    49.980000    74.970000    74.970000    74.970000    74.970000 
# phi         0.000000     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602 
# gnupl col      2            3            4            5            6            7            8            9           10           11           12           13           14      
# pos_id       102          103          104          105          106          107          108          109          110          111          112          113          114      
#
# lambda for peak transmission
#          482.9050000  482.9050000  482.9050000  482.9050000  482.9050000  479.9160000  479.9160000  482.9050000  482.9050000  479.9160000  479.9160000  482.9050000  482.9050000 
# peak transmission
#            0.7132102    0.7036874    0.6990799    0.7208663    0.7249353    0.6917503    0.6778341    0.7241739    0.7311290    0.6784305    0.6594788    0.7286594    0.7392190 
# lambda blue with 1/2 of peak transmission
#          386.6455966  386.5362380  386.5789450  386.9684424  386.7584004  386.4205708  386.3651176  386.6027705  386.6566656  386.5505627  386.9688076  386.5185922  386.6218885 
# lambda red  with 1/2 of peak transmission
#          491.3751745  491.0907404  491.0741293  492.0095774  491.7061342  490.4588608  490.2921085  491.3274860  491.3809116  490.2708184  490.2518865  491.0708064  491.1494443 
# half width                              
#          104.7295779  104.5545024  104.4951843  105.0411350  104.9477338  104.0382900  103.9269909  104.7247155  104.7242460  103.7202558  103.2830789  104.5522142  104.5275558 
# central wavelength                      
#          439.0103856  438.8134892  438.8265371  439.4890099  439.2322673  438.4397158  438.3286131  438.9651283  439.0187886  438.4106906  438.6103471  438.7946993  438.8856664 
# central wavelength calculated as SAGEM (mean frequency)
#          432.7643577  432.5855335  432.6058311  433.2126072  432.9633592  432.2678491  432.1683836  432.7190364  432.7735162  432.2760936  432.5301244  432.5667494  432.6619441 
# lambda blue with 80% of peak transmission
#          402.1642720  403.6801805  404.3425977  400.1571455  398.8942925  406.1792353  409.0943286  398.6773282  397.5818392  410.8283777  412.7484216  398.1326564  396.6630475 
# lambda red  with 80% of peak transmission
#          489.0636211  488.7994100  488.7710421  489.5443001  489.3173471  487.8438549  487.6325483  489.0623356  489.0991074  487.5502582  487.5546512  488.8453570  488.9149377 
# lambda blue with 0.0001 of peak transmission
#          374.7747568  374.7345537  374.7374470  374.9168115  374.8155059  373.4990741  372.6475393  374.7951519  374.8049919  372.4577863  372.3600073  374.7835079  374.7978326 
# lambda red  with 0.0001 of peak transmission
#          516.9625644  516.6497878  516.7414145  517.7995585  517.1524474  515.7237515  515.7502312  516.8489384  516.7616711  515.7678392  515.7723226  516.4829241  516.1817647 
# ATB calculated from points above 80%
#            0.6624340    0.6530045    0.6470780    0.6699752    0.6745601    0.6407254    0.6299644    0.6712951    0.6811255    0.6311668    0.6086705    0.6788525    0.6896732 
# ATB calculated from points above 50%
#            0.6352361    0.6226577    0.6166035    0.6452326    0.6501893    0.6057909    0.5911321    0.6505383    0.6601206    0.5877681    0.5712047    0.6553272    0.6690180 
# ABR calculated from points below and above 0.0001
#            0.0000052    0.0000096    0.0000327    0.0000088    0.0000226    0.0000510    0.0000547   -0.0000028    0.0000159    0.0000481    0.0000306    0.0000061    0.0000014 
# minCWL      = 438.328613 at column =  8, at id = 108 
# maxCWL      = 439.489010 at column =  5, at id = 105 
# difference =    1.1603968 
# minBW       = 103.283079 at column = 12, at id = 112 
# maxBW       = 105.041135 at column =  5, at id = 105 
# difference =    1.7580561 
# minATB80    = 0.608670 at column = 12, at id = 112 
# maxATB80    = 0.689673 at column = 14, at id = 114 
# difference =    0.0810028 
# minBlueEdge = 386.365118 at column =  8, at id = 108 
# maxBlueEdge = 386.968808 at column = 12, at id = 112 
# difference =    0.6036900 
# minRedEdge  = 490.251886 at column = 12, at id = 112 
# maxRedEdge  = 492.009577 at column =  5, at id = 105 
# difference =    1.7576909 
# minABR      = -0.000003 at column =  9, at id = 109 
# maxABR      = 0.000055 at column =  8, at id = 108 
# difference =    0.0000575 
  299.645    -0.000062    -0.000108     0.000027    -0.000173     0.000228     0.000291     0.000420    -0.000237    -0.000047     0.000173     0.000168    -0.000197    -0.000153 
  302.654    -0.000045    -0.000088     0.000081    -0.000020    -0.000064     0.000090     0.000171    -0.000078    -0.000013     0.000077     0.000015    -0.000068    -0.000041 
  305.662    -0.000057    -0.000015     0.000063    -0.000039    -0.000024     0.000026     0.000048    -0.000003     0.000009     0.000055    -0.000016    -0.000005     0.000002 
  308.671    -0.000040    -0.000010     0.000013     0.000001    -0.000006     0.000030     0.000018    -0.000033     0.000022     0.000066     0.000010    -0.000009    -0.000020 
  311.679    -0.000012    -0.000016     0.000002    -0.000042    -0.000005     0.000009     0.000015    -0.000018     0.000009     0.000026    -0.000009    -0.000019    -0.000020 
  314.687    -0.000031    -0.000003    -0.000012    -0.000008    -0.000021     0.000008    -0.000002    -0.000005     0.000004     0.000035    -0.000007     0.000001    -0.000006 
  317.694    -0.000019    -0.000005     0.000015     0.000001     0.000005     0.000033     0.000009    -0.000006    -0.000010     0.000028     0.000014     0.000001     0.000003 
  320.702    -0.000017    -0.000014     0.000013     0.000012    -0.000014     0.000023     0.000008    -0.000001     0.000022     0.000017     0.000009    -0.000010     0.000001 
  323.709    -0.000014    -0.000004     0.000003    -0.000009    -0.000006     0.000011    -0.000007    -0.000009     0.000016     0.000011    -0.000012     0.000001    -0.000012 
  326.716    -0.000000     0.000004    -0.000001    -0.000002    -0.000004     0.000007     0.000006    -0.000006     0.000013     0.000018    -0.000007    -0.000006    -0.000014 
  329.665    -0.000011    -0.000006    -0.000001    -0.000002     0.000003     0.000010     0.000008    -0.000011     0.000008     0.000010    -0.000008    -0.000004    -0.000005 
  332.672    -0.000013    -0.000008     0.000007    -0.000010    -0.000004     0.000001    -0.000002    -0.000007    -0.000005     0.000010    -0.000005    -0.000006    -0.000001 
  335.678    -0.000004     0.000002     0.000001     0.000000    -0.000001     0.000010     0.000002    -0.000009    -0.000001     0.000006     0.000001     0.000001    -0.000003 
  338.683    -0.000000     0.000006    -0.000001     0.000004    -0.000001     0.000005    -0.000002    -0.000008     0.000002     0.000006     0.000004     0.000001    -0.000001 
  341.689    -0.000006    -0.000004    -0.000001     0.000000    -0.000002     0.000002     0.000003    -0.000006    -0.000003     0.000010     0.000004     0.000006     0.000000 
  344.694    -0.000002    -0.000003    -0.000003     0.000004    -0.000002     0.000004     0.000002     0.000002    -0.000002     0.000006    -0.000001     0.000006    -0.000001 
  347.699     0.000002    -0.000004    -0.000001     0.000003    -0.000003     0.000005    -0.000004    -0.000002    -0.000001     0.000005    -0.000001     0.000006    -0.000001 
  350.703    -0.000004    -0.000003    -0.000002     0.000005    -0.000003     0.000008    -0.000001    -0.000007    -0.000003    -0.000001    -0.000001     0.000007    -0.000004 
  353.707     0.000001    -0.000001     0.000000     0.000002    -0.000001     0.000009    -0.000004    -0.000001    -0.000005     0.000001     0.000001     0.000002    -0.000001 
  356.711    -0.000001     0.000003    -0.000001    -0.000004     0.000004     0.000001    -0.000001     0.000001    -0.000002     0.000003    -0.000002     0.000003    -0.000001 
  359.715    -0.000001     0.000003    -0.000003    -0.000001     0.000005     0.000005     0.000001    -0.000003     0.000000     0.000001     0.000002     0.000004    -0.000001 
  362.718    -0.000000     0.000003    -0.000002     0.000003     0.000001     0.000002     0.000001    -0.000000     0.000001     0.000001    -0.000001     0.000005     0.000001 
  365.721    -0.000001     0.000001    -0.000001     0.000001     0.000003     0.000001    -0.000000    -0.000001    -0.000001     0.000001    -0.000001     0.000003     0.000001 
  368.724     0.000001     0.000001    -0.000000     0.000003     0.000003     0.000001    -0.000001     0.000003    -0.000001    -0.000002     0.000001     0.000001     0.000003 
  371.726    -0.000001     0.000001     0.000002     0.000004     0.000005     0.000004    -0.000000    -0.000001     0.000001    -0.000003     0.000001     0.000006     0.000001 
  374.728     0.000001     0.000055     0.000048     0.000006     0.000004     0.000115     0.000221    -0.000001    -0.000001     0.000287     0.000307     0.000004     0.000000 
  377.730     0.004489     0.007165     0.007097     0.001051     0.002345     0.010436     0.013011     0.003269     0.002905     0.013345     0.013508     0.003752     0.003178 
  380.788     0.043060     0.054090     0.054435     0.028728     0.034789     0.071510     0.082861     0.039108     0.036432     0.085947     0.085119     0.042008     0.036898 
  383.789     0.199517     0.221906     0.221433     0.157176     0.176144     0.246350     0.251421     0.191033     0.183345     0.250366     0.238634     0.200429     0.186940 
  386.789     0.364491     0.363799     0.359185     0.354279     0.364388     0.359809     0.353314     0.373408     0.373973     0.346887     0.325283     0.380567     0.380385 
  389.790     0.465212     0.459083     0.452311     0.457209     0.471749     0.448756     0.436371     0.478898     0.485375     0.427290     0.399664     0.488293     0.500039 
  392.790     0.523118     0.506379     0.498618     0.535766     0.543030     0.484007     0.467756     0.544222     0.556136     0.458192     0.429590     0.551565     0.568558 
  395.790     0.541167     0.524782     0.517565     0.552907     0.560262     0.505250     0.488860     0.561584     0.573261     0.480980     0.451949     0.568131     0.586200 
  398.789     0.559425     0.542567     0.534582     0.573470     0.579675     0.519512     0.501325     0.580026     0.592747     0.491962     0.462909     0.587073     0.603977 
  401.788     0.568421     0.551455     0.544762     0.580535     0.587461     0.534044     0.517730     0.588305     0.600610     0.511326     0.482025     0.594410     0.613372 
  404.787     0.585537     0.569674     0.561787     0.598841     0.606027     0.550579     0.532403     0.606003     0.618989     0.527722     0.499300     0.612050     0.629677 
  407.785     0.593578     0.576688     0.569505     0.607722     0.613568     0.556654     0.538254     0.613807     0.626593     0.531914     0.504353     0.619470     0.636770 
  410.783     0.597751     0.581475     0.575323     0.609985     0.616479     0.563206     0.547443     0.617830     0.629050     0.542456     0.515439     0.623365     0.639621 
  413.781     0.607062     0.593244     0.586481     0.616563     0.623979     0.578522     0.563264     0.626004     0.637059     0.561480     0.533963     0.632312     0.647301 
  416.834     0.628345     0.614720     0.607339     0.636013     0.644789     0.597311     0.580236     0.646263     0.658228     0.576599     0.548737     0.652469     0.668956 
  419.831     0.640439     0.626388     0.619466     0.649191     0.657861     0.609692     0.593605     0.658854     0.670884     0.591637     0.563964     0.665025     0.682012 
  422.828     0.644016     0.630901     0.624182     0.654459     0.661384     0.614608     0.598143     0.661771     0.673852     0.596765     0.569611     0.667399     0.683335 
  425.824     0.646766     0.633947     0.627023     0.658454     0.663582     0.616456     0.600048     0.664216     0.676557     0.597056     0.570520     0.670970     0.686701 
  428.820     0.649383     0.637114     0.630791     0.661057     0.666234     0.622787     0.607188     0.666549     0.678424     0.606869     0.581271     0.672229     0.687536 
  431.815     0.653926     0.641252     0.635572     0.663122     0.669714     0.626316     0.610839     0.670704     0.681199     0.609753     0.584650     0.676264     0.689988 
  434.810     0.652895     0.638140     0.632084     0.667100     0.671614     0.618585     0.604080     0.671063     0.682096     0.602836     0.578248     0.675129     0.690563 
  437.862     0.650423     0.642625     0.636331     0.655319     0.662691     0.633544     0.620653     0.664071     0.672947     0.620441     0.596399     0.669043     0.683361 
  440.856     0.671648     0.660896     0.654259     0.678035     0.685132     0.644546     0.630743     0.685779     0.695245     0.629795     0.605827     0.690460     0.704809 
  443.850     0.670052     0.656095     0.650205     0.680466     0.686426     0.636470     0.621815     0.685868     0.695773     0.620733     0.598338     0.689548     0.704490 
  446.844     0.656376     0.645791     0.640182     0.664374     0.670582     0.633718     0.623884     0.671935     0.679021     0.622009     0.599403     0.676042     0.688398 
  449.837     0.682287     0.672575     0.667447     0.683935     0.692643     0.659757     0.646876     0.694885     0.703115     0.644707     0.621457     0.699712     0.713349 
  452.830     0.690005     0.678694     0.673249     0.696880     0.702386     0.662497     0.648513     0.703110     0.712035     0.642667     0.619743     0.706890     0.721005 
  455.878     0.690418     0.676949     0.670643     0.699108     0.704332     0.657328     0.643936     0.704272     0.713562     0.635585     0.613135     0.709281     0.722754 
  458.870     0.691539     0.680713     0.675022     0.698758     0.703064     0.669131     0.656681     0.704526     0.713444     0.656069     0.634298     0.709218     0.721948 
  461.862     0.699209     0.688927     0.683490     0.706958     0.709922     0.676901     0.663559     0.710772     0.719423     0.664069     0.642734     0.715243     0.727551 
  464.853     0.699624     0.688049     0.682858     0.710199     0.711432     0.674331     0.660915     0.711845     0.720895     0.659853     0.640426     0.716407     0.728078 
  467.901     0.696618     0.685607     0.680046     0.706819     0.708749     0.671351     0.658343     0.709270     0.717967     0.656462     0.637864     0.714863     0.725771 
  470.891     0.696999     0.687165     0.682313     0.705916     0.707787     0.676992     0.666323     0.708579     0.717092     0.665034     0.646199     0.714813     0.725644 
  473.881     0.708801     0.698503     0.693305     0.716700     0.718875     0.683169     0.670068     0.719818     0.727764     0.668142     0.649636     0.724254     0.735590 
  476.871     0.699361     0.690001     0.685045     0.708206     0.711428     0.679762     0.668284     0.711545     0.717817     0.668821     0.650546     0.715080     0.725007 
  479.916     0.706136     0.700215     0.694788     0.712089     0.716538     0.691750     0.677834     0.716431     0.723183     0.678430     0.659479     0.721013     0.730813 
  482.905     0.713210     0.703687     0.699080     0.720866     0.724935     0.689491     0.676815     0.724174     0.731129     0.672865     0.654965     0.728659     0.739219 
  485.894     0.700545     0.684107     0.680430     0.716728     0.717379     0.654735     0.639213     0.714749     0.721937     0.630950     0.615872     0.716737     0.727009 
  488.882     0.587379     0.559506     0.554591     0.634812     0.619583     0.499448     0.472595     0.596635     0.605773     0.471822     0.457014     0.581266     0.594644 
  491.925     0.305712     0.273408     0.269950     0.367780     0.342542     0.203086     0.184120     0.304779     0.313264     0.181272     0.174292     0.279669     0.292639 
  494.913     0.081014     0.067782     0.067440     0.108211     0.097282     0.045914     0.041306     0.081440     0.083764     0.041427     0.039690     0.071874     0.074769 
  497.899     0.018704     0.016624     0.016609     0.023477     0.021419     0.013058     0.012060     0.018466     0.018652     0.012438     0.011958     0.016640     0.016821 
  500.942     0.006456     0.005817     0.005793     0.007836     0.007162     0.004489     0.004136     0.006350     0.006347     0.004175     0.004037     0.005788     0.005802 
  503.928     0.002299     0.002005     0.001991     0.002878     0.002608     0.001445     0.001328     0.002331     0.002323     0.001316     0.001277     0.002108     0.002128 
  506.913     0.000772     0.000733     0.000726     0.000898     0.000840     0.000650     0.000616     0.000761     0.000763     0.000637     0.000617     0.000709     0.000708 
  509.954     0.000403     0.000380     0.000380     0.000460     0.000430     0.000319     0.000299     0.000392     0.000392     0.000308     0.000296     0.000372     0.000364 
  512.939     0.000201     0.000186     0.000185     0.000226     0.000212     0.000151     0.000141     0.000193     0.000193     0.000136     0.000131     0.000187     0.000182 
  515.923     0.000085     0.000079     0.000080     0.000105     0.000091     0.000063     0.000063     0.000086     0.000085     0.000064     0.000062     0.000080     0.000077 
  518.963     0.000045     0.000044     0.000044     0.000052     0.000045     0.000040     0.000040     0.000041     0.000041     0.000040     0.000040     0.000040     0.000040 
  521.946     0.000031     0.000026     0.000031     0.000033     0.000029     0.000032     0.000029     0.000032     0.000030     0.000028     0.000028     0.000029     0.000028 
  524.929     0.000020     0.000019     0.000016     0.000019     0.000020     0.000017     0.000016     0.000021     0.000021     0.000013     0.000015     0.000018     0.000018 
  527.967     0.000014     0.000014     0.000016     0.000010     0.000014     0.000017     0.000013     0.000013     0.000015     0.000014     0.000014     0.000014     0.000013 
  530.949     0.000014     0.000013     0.000007     0.000005     0.000006     0.000007     0.000007     0.000007     0.000012     0.000006     0.000011     0.000012     0.000007 
  533.987     0.000010     0.000010     0.000013     0.000006     0.000008     0.000005     0.000007     0.000010     0.000011     0.000008     0.000013     0.000010     0.000007 
  536.968     0.000006     0.000000     0.000002     0.000006     0.000002     0.000004     0.000002     0.000011     0.000004     0.000002     0.000000     0.000010     0.000002 
  539.948     0.000001     0.000003     0.000003     0.000004     0.000002     0.000003     0.000002     0.000005     0.000003     0.000003     0.000002     0.000006     0.000002 
  542.984     0.000002     0.000002     0.000003     0.000003     0.000002     0.000002     0.000002     0.000001    -0.000001     0.000002     0.000002     0.000005     0.000002 
  545.964     0.000002     0.000002     0.000002     0.000003     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000002     0.000003     0.000001 
  548.999     0.000006     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000002     0.000001     0.000002     0.000002     0.000001 
  551.977     0.000001     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001 
  555.012     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000000 
  557.989     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001     0.000001     0.000002     0.000001     0.000001     0.000003     0.000001 
  561.023     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000001 
  563.999     0.000002     0.000001     0.000002     0.000002     0.000001     0.000001     0.000000     0.000002     0.000002     0.000001     0.000000     0.000002     0.000001 
  567.032     0.000002     0.000001     0.000002     0.000002     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000002     0.000000 
  570.007     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001 
  573.038     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000002     0.000000 
  576.013    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000000    -0.000001     0.000001    -0.000000 
  579.043     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000001    -0.000001 
  582.017    -0.000000    -0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000000    -0.000000    -0.000000     0.000001    -0.000001 
  585.046    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000001    -0.000001    -0.000001    -0.000000    -0.000000    -0.000001     0.000001    -0.000001 
  588.019    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000001     0.000000    -0.000001 
  591.047     0.000000     0.000000     0.000000    -0.000000    -0.000001     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000001    -0.000000    -0.000001 
  594.019     0.000000     0.000000     0.000000    -0.000001    -0.000001     0.000000    -0.000001    -0.000001     0.000000    -0.000000    -0.000001    -0.000000    -0.000001 
  597.046     0.000000     0.000001     0.000000    -0.000000    -0.000001     0.000000    -0.000001    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000001 
  600.073     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000001    -0.000000     0.000000    -0.000001    -0.000001     0.000000    -0.000001 
  603.043    -0.000000    -0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000001     0.000000    -0.000000 
  606.068    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000001     0.000001    -0.000001 
  609.038    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000001 
  612.062     0.000001     0.000000     0.000000     0.000001    -0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000001 
  615.086    -0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000000    -0.000001 
  618.053    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000001 
  621.076    -0.000000    -0.000000     0.000000     0.000001    -0.000001     0.000001     0.000001    -0.000000     0.000000    -0.000000    -0.000000     0.000001    -0.000000 
  624.099    -0.000000     0.000000    -0.000000     0.000000    -0.000001     0.000001     0.000000    -0.000000    -0.000000     0.000000    -0.000001     0.000001    -0.000000 
  627.064     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000    -0.000000     0.000001    -0.000000 
  630.086     0.000001     0.000001     0.000001     0.000002     0.000000    -0.000000    -0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000001    -0.000000 
  633.106     0.000000     0.000000     0.000000     0.000001    -0.000001     0.000000    -0.000000     0.000000    -0.000001    -0.000001    -0.000001    -0.000000    -0.000001 
  636.071    -0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000001    -0.000001 
  639.090     0.000001    -0.000000     0.000001     0.000001    -0.000000    -0.000000    -0.000000    -0.000001     0.000000    -0.000000    -0.000001     0.000000    -0.000001 
  642.109     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000001    -0.000000    -0.000001 
  645.128    -0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000001     0.000001    -0.000000 
  648.090     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000000    -0.000000    -0.000000     0.000001    -0.000000 
  651.107     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000    -0.000001    -0.000000     0.000000    -0.000000 
  654.123    -0.000000    -0.000000     0.000001     0.000001     0.000000    -0.000000    -0.000001     0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000000 
  657.139     0.000000     0.000000     0.000001     0.000001     0.000000    -0.000000    -0.000000    -0.000001     0.000000    -0.000001    -0.000001    -0.000000    -0.000001 
  660.099    -0.000000    -0.000000     0.000001     0.000001    -0.000000    -0.000000     0.000000    -0.000001     0.000000    -0.000001    -0.000001    -0.000000     0.000000 
  663.114    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000001    -0.000000    -0.000000     0.000000    -0.000001    -0.000001    -0.000000    -0.000000 
  666.129    -0.000000    -0.000000     0.000000    -0.000000     0.000001    -0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000001     0.000000    -0.000000 
  669.142     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000000    -0.000000 
  672.155     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000000    -0.000000 
  675.168    -0.000000     0.000000     0.000000     0.000001     0.000001     0.000001    -0.000001    -0.000000    -0.000000    -0.000001     0.000000     0.000000    -0.000000 
  678.124    -0.000000    -0.000000    -0.000000     0.000001     0.000000    -0.000000    -0.000000    -0.000001    -0.000001    -0.000000    -0.000000     0.000000    -0.000000 
  681.136    -0.000000    -0.000001     0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000    -0.000001    -0.000001     0.000000     0.000000    -0.000001 
  684.146    -0.000000    -0.000000     0.000001    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000001    -0.000001    -0.000000    -0.000000    -0.000000 
  687.157     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000001    -0.000001    -0.000000    -0.000001    -0.000001    -0.000000     0.000001    -0.000000 
  690.166    -0.000001    -0.000001     0.000000     0.000000    -0.000000    -0.000001    -0.000001    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000001 
  693.175    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000010     0.000016    -0.000000     0.000000     0.000013     0.000012    -0.000000    -0.000001 
  696.183     0.000097     0.000111     0.000110     0.000048     0.000071     0.000121     0.000112     0.000078     0.000080     0.000110     0.000101     0.000082     0.000078 
  699.191     0.000068     0.000037     0.000044     0.000107     0.000088    -0.000001     0.000000     0.000044     0.000050     0.000001     0.000001     0.000021     0.000031 
  702.198     0.000001     0.000001     0.000001     0.000000     0.000000    -0.000000     0.000001    -0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001 
  705.205    -0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000001    -0.000001    -0.000001    -0.000000     0.000001    -0.000001 
  708.211    -0.000000     0.000000     0.000001     0.000001     0.000000    -0.000001    -0.000000    -0.000001    -0.000001    -0.000001    -0.000001     0.000000    -0.000000 
  711.216    -0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000005    -0.000001    -0.000001     0.000006     0.000011     0.000000     0.000000 
  714.220     0.000001     0.000001     0.000001     0.000001     0.000001     0.000004     0.000003    -0.000001    -0.000000    -0.000001     0.000000     0.000001    -0.000000 
  717.224     0.000001     0.000001     0.000003     0.000002     0.000001     0.000001     0.000001     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000000 
  720.228     0.000001     0.000001     0.000001     0.000003     0.000001     0.000001    -0.000000     0.000001     0.000001    -0.000000    -0.000000     0.000001     0.000001 
  723.230     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000    -0.000000    -0.000001     0.000001    -0.000001 
  726.232    -0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000001    -0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000001 
  729.234    -0.000000     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000001     0.000000    -0.000001 
  732.234    -0.000001    -0.000000     0.000001     0.000001     0.000001     0.000000    -0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000001    -0.000001 
  735.235    -0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000001     0.000000     0.000001    -0.000001 
  738.234     0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  741.233    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000    -0.000000    -0.000000     0.000001     0.000001    -0.000000 
  744.231    -0.000000     0.000000     0.000001     0.000002     0.000001    -0.000000    -0.000001    -0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000000 
  747.228     0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000000    -0.000001    -0.000000    -0.000000    -0.000001    -0.000000    -0.000000    -0.000000 
  750.225    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000000    -0.000001    -0.000001    -0.000000    -0.000001     0.000000     0.000001     0.000000 
  753.221    -0.000001     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001    -0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000 
  756.272     0.000000    -0.000001     0.000001     0.000001    -0.000000     0.000001    -0.000000    -0.000001    -0.000001     0.000001     0.000001     0.000000    -0.000001 
  759.267     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000002    -0.000000    -0.000001     0.000002     0.000002     0.000001    -0.000000 
  762.261     0.000001     0.000001     0.000002     0.000002     0.000001     0.000010     0.000020     0.000001     0.000000     0.000026     0.000023     0.000001     0.000001 
  765.254     0.000018     0.000023     0.000026     0.000003     0.000002     0.000027     0.000019     0.000016     0.000014     0.000022     0.000018     0.000018     0.000013 
  768.247     0.000015     0.000005     0.000008     0.000023     0.000019     0.000002     0.000001     0.000015     0.000012     0.000001     0.000001     0.000013     0.000014 
  771.294     0.000001     0.000002     0.000002     0.000002     0.000002     0.000013     0.000017     0.000001     0.000001     0.000020     0.000023     0.000001    -0.000000 
  774.286     0.000015     0.000027     0.000029     0.000002     0.000002     0.000033     0.000032     0.000001     0.000001     0.000026     0.000026     0.000013     0.000001 
  777.277     0.000025     0.000011     0.000009     0.000036     0.000027     0.000005     0.000003     0.000029     0.000030     0.000001     0.000002     0.000027     0.000024 
  780.266     0.000001     0.000002    -0.000002     0.000003     0.000002     0.000001     0.000001     0.000001    -0.000000    -0.000001    -0.000001     0.000001    -0.000000 
  783.311    -0.000000    -0.000001    -0.000000     0.000001    -0.000000     0.000001     0.000001    -0.000000    -0.000001    -0.000001    -0.000000     0.000000     0.000000 
  786.300    -0.000000    -0.000002     0.000001     0.000001     0.000000    -0.000000     0.000000    -0.000001    -0.000002    -0.000000    -0.000000     0.000001    -0.000001 
  789.288     0.000001    -0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000001    -0.000001     0.000000    -0.000001    -0.000000 
  792.275     0.000007     0.000007     0.000009     0.000001     0.000001     0.000019     0.000016     0.000017     0.000015     0.000014     0.000015     0.000025     0.000017 
  795.316     0.000016     0.000012     0.000008     0.000029     0.000023     0.000003     0.000002     0.000017     0.000017    -0.000000    -0.000001     0.000017     0.000016 
  798.302    -0.000001    -0.000000     0.000001     0.000004     0.000001     0.000001     0.000001    -0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000000 
  801.287     0.000000     0.000000     0.000000     0.000002     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000001     0.000000 
  804.327    -0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000000    -0.000001     0.000000 
  807.310     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000000    -0.000000 
  810.348     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000000    -0.000000    -0.000000 
  813.331    -0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
  816.312    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000000 
  819.348    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000 
  822.328     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000000     0.000000 
  825.362     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000000     0.000000 
  828.341     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
  831.374     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000000    -0.000001    -0.000000     0.000000    -0.000000 
  834.351     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000001    -0.000000 
  837.382    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000001    -0.000001    -0.000000     0.000000    -0.000000 
  840.357     0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000 
  843.387    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000006     0.000011     0.000000    -0.000000     0.000022     0.000022    -0.000000     0.000000 
  846.361    -0.000000     0.000013     0.000011     0.000001     0.000000     0.000025     0.000019     0.000000    -0.000000     0.000012     0.000013    -0.000000     0.000000 
  849.389     0.000015     0.000015     0.000016     0.000001     0.000005     0.000003    -0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000000    -0.000000 
  852.362     0.000001     0.000001     0.000001     0.000007     0.000010     0.000001     0.000000     0.000011     0.000007    -0.000000    -0.000000     0.000007     0.000002 
  855.389     0.000001     0.000000     0.000001    -0.000001     0.000002     0.000001    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000001     0.000001 
  858.359    -0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000001    -0.000000    -0.000000    -0.000000    -0.000000 
  861.385     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000001     0.000000    -0.000000 
  864.409     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000 
  867.378     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000000    -0.000000 
  870.400     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000002     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000000    -0.000000 
  873.422     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000001 
  876.389     0.000001     0.000001     0.000002     0.000002     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000001 
  879.409     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000000 
  882.428     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000 
  885.447    -0.000000    -0.000000     0.000000    -0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  888.410    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000001     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000 
  891.427     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000001    -0.000000 
  894.444     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000 
  897.459     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000 
  900.419     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000     0.000003     0.000004    -0.000000     0.000000 
  903.433     0.000000     0.000001     0.000001     0.000000     0.000000     0.000002     0.000006     0.000000    -0.000000     0.000006     0.000006    -0.000000    -0.000000 
  906.446     0.000000     0.000003     0.000001     0.000000     0.000000     0.000002     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000 
  909.458     0.000002     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  912.469     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000 
  915.480    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  918.489     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  921.443     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  924.451     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  927.458     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  930.465     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000 
  933.470     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000 
  936.475     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000 
  939.478     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
  942.481     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000 
  945.483    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000 
  948.484     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
  951.484    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
  954.538    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
  957.537    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000 
  960.534     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000 
  963.531     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000 
  966.526     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000 
  969.521    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
  972.515     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000 
  975.563    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000 
  978.555     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000 
  981.546     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  984.537    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  987.580     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  990.569     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  993.556     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  996.543     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  999.583     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
 1002.568     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
 1005.552     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
 1008.589     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1011.571     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1014.606     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1017.587     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1020.620     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1023.598     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
 1026.629     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1029.606     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1032.635     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
 1035.610     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
 1038.637     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
 1041.610     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
 1044.635     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1047.660     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1050.629     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1053.652     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1056.620     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1059.640     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1062.660     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1065.678     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1068.642     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1071.658     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1074.674     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1077.688     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1080.702     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1083.660     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1086.672     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1089.682     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1092.691     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1095.699     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1098.707     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1101.713     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1104.718     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1107.722     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1110.725     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1113.727     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1116.728     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1119.728     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1122.726     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1125.724     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1128.720     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1131.770     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1134.764     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1137.757     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1140.749     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1143.741     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1146.784     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1149.773     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1152.761     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1155.801     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1158.786     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1161.771     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1164.807     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1167.790     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1170.771     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1173.804     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1176.783     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1179.814     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1182.790     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1185.819     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1188.793     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1191.820     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1194.845     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1197.815     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1200.838     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 