# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 71
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       2.110000     2.110000     1.490000     1.490000     2.500000     2.500000     1.320000     1.320000 
# z_pos      57.000000    57.000000    56.000000    56.000000    58.000000    58.000000    55.000000    55.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       121          122          123          124          125          126          127          128      
#
# lambda for peak transmission
#          482.9050000  482.9050000  482.9050000  482.9050000  482.9050000  479.9160000  482.9050000  482.9050000 
# peak transmission
#            0.7144029    0.6967811    0.7088625    0.7280614    0.7136490    0.6778737    0.7024584    0.7368608 
# lambda blue with 1/2 of peak transmission
#          386.6024710  386.4957273  386.6299489  386.6536827  386.5804406  386.2899189  386.6381727  386.5770807 
# lambda red  with 1/2 of peak transmission
#          491.3167388  490.8764165  491.3109987  491.4179421  491.2104790  490.0411733  491.1628050  491.0868202 
# half width                              
#          104.7142678  104.3806891  104.6810498  104.7642594  104.6300384  103.7512544  104.5246323  104.5097395 
# central wavelength                      
#          438.9596049  438.6860719  438.9704738  439.0358124  438.8954598  438.1655461  438.9004888  438.8319505 
# central wavelength calculated as SAGEM (mean frequency)
#          432.7146807  432.4770029  432.7296656  432.7860090  432.6596668  432.0238476  432.6773249  432.6095881 
# lambda blue with 80% of peak transmission
#          401.9703892  404.4795497  402.7109489  398.3268925  402.1042748  410.2632022  403.9466459  396.3971742 
# lambda red  with 80% of peak transmission
#          489.0180434  488.4399094  489.0250164  489.1321065  488.9392423  487.3061276  488.9148889  488.8813265 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.6643096    0.6451380    0.6571721    0.6761319    0.6626105    0.6275504    0.6478709    0.6911371 
# ATB calculated from points above 50%
#            0.6373150    0.6143807    0.6299963    0.6551263    0.6357336    0.5879104    0.6204905    0.6674084 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 438.165546 at column =  7, at id = 126 
# maxCWL      = 439.035812 at column =  5, at id = 124 
# difference =    0.8702662 
# minBW       = 103.751254 at column =  7, at id = 126 
# maxBW       = 104.764259 at column =  5, at id = 124 
# difference =    1.0130050 
# minATB80    = 0.627550 at column =  7, at id = 126 
# maxATB80    = 0.691137 at column =  9, at id = 128 
# difference =    0.0635867 
# minBlueEdge = 386.289919 at column =  7, at id = 126 
# maxBlueEdge = 386.653683 at column =  5, at id = 124 
# difference =    0.3637637 
# minRedEdge  = 490.041173 at column =  7, at id = 126 
# maxRedEdge  = 491.417942 at column =  5, at id = 124 
# difference =    1.3767687 
# minABR      = 9.999900 at column =  2, at id = 121 
# maxABR      = 9.999900 at column =  2, at id = 121 
# difference =    0.0000000 
  359.715     0.000007     0.000005     0.000005     0.000004     0.000002     0.000004    -0.000005     0.000002 
  362.718     0.000008     0.000001     0.000005     0.000001     0.000003     0.000003    -0.000000     0.000001 
  365.721     0.000007     0.000002     0.000003     0.000002    -0.000001     0.000004    -0.000001     0.000001 
  368.724     0.000006     0.000001     0.000001    -0.000001    -0.000000     0.000002    -0.000001     0.000005 
  371.726     0.000008     0.000004     0.000003     0.000002    -0.000001     0.000004    -0.000000     0.000003 
  374.728     0.000007     0.000075     0.000001     0.000003     0.000003     0.000347     0.000004     0.000002 
  377.730     0.005058     0.008398     0.004956     0.002959     0.005587     0.014995     0.005928     0.002779 
  380.788     0.044782     0.060184     0.044774     0.036930     0.046860     0.093357     0.049384     0.037112 
  383.789     0.202944     0.230520     0.203063     0.184510     0.209542     0.259700     0.212515     0.187522 
  386.789     0.367428     0.361162     0.362906     0.372511     0.367829     0.354749     0.358572     0.382181 
  389.790     0.469242     0.454159     0.461808     0.480852     0.470307     0.434588     0.453946     0.497976 
  392.790     0.526329     0.496346     0.516780     0.548991     0.524251     0.462465     0.504189     0.568593 
  395.790     0.543844     0.515532     0.534851     0.566393     0.542115     0.485366     0.521929     0.585896 
  398.789     0.562947     0.531046     0.552901     0.585374     0.560589     0.495335     0.540120     0.603642 
  401.788     0.570419     0.542552     0.561788     0.593630     0.569045     0.514985     0.549304     0.612387 
  404.787     0.588565     0.559124     0.579017     0.611565     0.586815     0.528715     0.566896     0.629422 
  407.785     0.596077     0.566510     0.587112     0.619261     0.594144     0.533793     0.574695     0.636225 
  410.783     0.599541     0.572536     0.591527     0.622343     0.598127     0.544083     0.580140     0.639543 
  413.781     0.609718     0.584962     0.601260     0.630527     0.608001     0.561957     0.590409     0.646425 
  416.834     0.631131     0.605627     0.622447     0.651334     0.629877     0.577453     0.611804     0.666861 
  419.831     0.643032     0.617765     0.634744     0.663999     0.641658     0.591677     0.623809     0.679985 
  422.828     0.647133     0.621984     0.638850     0.666613     0.645668     0.595612     0.628011     0.681458 
  425.824     0.650381     0.624598     0.642144     0.669822     0.648457     0.597538     0.631948     0.684609 
  428.820     0.652609     0.629064     0.644287     0.671288     0.650675     0.605803     0.634440     0.686090 
  431.815     0.656774     0.633396     0.648755     0.674847     0.654858     0.608191     0.638541     0.688894 
  434.810     0.655453     0.628848     0.647227     0.675796     0.652774     0.601044     0.636631     0.688955 
  437.862     0.652903     0.636793     0.645518     0.667730     0.652597     0.620745     0.637618     0.680851 
  440.856     0.674330     0.653280     0.666441     0.690537     0.672670     0.628680     0.657328     0.703086 
  443.850     0.672170     0.647667     0.664615     0.691216     0.669969     0.618160     0.654602     0.703037 
  446.844     0.658214     0.639446     0.651310     0.675676     0.656459     0.624028     0.642620     0.686399 
  449.837     0.683893     0.666433     0.677116     0.699294     0.683633     0.644878     0.669624     0.710936 
  452.830     0.692139     0.670911     0.684354     0.708461     0.690504     0.644351     0.676140     0.718060 
  455.878     0.692264     0.667684     0.684708     0.710406     0.690036     0.639642     0.675690     0.719857 
  458.870     0.693058     0.674229     0.686222     0.709304     0.691593     0.656049     0.677834     0.719541 
  461.862     0.700909     0.682276     0.694395     0.715263     0.699966     0.662060     0.686300     0.725100 
  464.853     0.700961     0.680825     0.694363     0.716225     0.699673     0.658031     0.686406     0.726278 
  467.901     0.698091     0.678289     0.691666     0.713682     0.696665     0.655859     0.683926     0.723738 
  470.891     0.698175     0.681529     0.692180     0.713026     0.697179     0.667097     0.685271     0.723578 
  473.881     0.709922     0.691518     0.704178     0.723720     0.709043     0.667227     0.697174     0.733240 
  476.871     0.700265     0.684134     0.694948     0.714874     0.699177     0.669039     0.688282     0.723787 
  479.916     0.707890     0.694174     0.702969     0.720242     0.707873     0.677874     0.696785     0.728881 
  482.905     0.714403     0.696781     0.708862     0.728061     0.713649     0.673050     0.702458     0.736861 
  485.894     0.700461     0.673487     0.696096     0.719154     0.697273     0.626353     0.687478     0.726296 
  488.882     0.584206     0.537271     0.580394     0.606348     0.576315     0.448499     0.565050     0.589458 
  491.925     0.300490     0.249085     0.297312     0.315580     0.289471     0.160883     0.279775     0.284405 
  494.913     0.078376     0.059936     0.077510     0.085179     0.073928     0.035856     0.070829     0.072883 
  497.899     0.018213     0.015307     0.018104     0.019032     0.017593     0.011078     0.017123     0.016478 
  500.942     0.006304     0.005364     0.006317     0.006499     0.006122     0.003745     0.006029     0.005692 
  503.928     0.002231     0.001816     0.002252     0.002391     0.002144     0.001190     0.002119     0.002109 
  506.913     0.000761     0.000698     0.000759     0.000779     0.000748     0.000589     0.000738     0.000700 
  509.954     0.000401     0.000358     0.000396     0.000403     0.000390     0.000282     0.000386     0.000359 
  512.939     0.000197     0.000171     0.000196     0.000196     0.000192     0.000127     0.000189     0.000180 
  515.923     0.000084     0.000073     0.000084     0.000086     0.000081     0.000061     0.000082     0.000080 
  518.963     0.000042     0.000039     0.000041     0.000043     0.000045     0.000038     0.000043     0.000036 
  521.946     0.000031     0.000028     0.000032     0.000028     0.000032     0.000025     0.000028     0.000028 
  524.929     0.000020     0.000018     0.000022     0.000022     0.000019     0.000015     0.000019     0.000019 
  527.967     0.000013     0.000015     0.000015     0.000013     0.000014     0.000014     0.000014     0.000014 
  530.949     0.000011     0.000012     0.000002     0.000012     0.000002     0.000013     0.000011     0.000006 
  533.987     0.000012     0.000014     0.000009     0.000006     0.000014     0.000002     0.000011     0.000012 
  536.968     0.000002     0.000010     0.000008     0.000001     0.000002     0.000005     0.000001     0.000006 
  539.948     0.000002     0.000002     0.000006     0.000002     0.000002     0.000004     0.000002     0.000002 
  542.984     0.000002     0.000002     0.000006     0.000002     0.000002     0.000003     0.000002     0.000002 
  545.964     0.000002     0.000002     0.000001     0.000002     0.000002     0.000003     0.000002     0.000002 
  548.999     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002 
  551.977     0.000002     0.000002     0.000002     0.000001     0.000001     0.000002     0.000002     0.000002 
  555.012     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001 
  557.989     0.000001     0.000002     0.000001     0.000001     0.000002     0.000002     0.000001     0.000002 
  561.023     0.000002     0.000001     0.000002     0.000001     0.000002     0.000002     0.000001     0.000002 
  563.999     0.000002     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002 
  567.032     0.000002     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000002 
  570.007     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000002 