# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 41
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       2.110000     2.110000     1.490000     1.490000     2.500000     2.500000     1.320000     1.320000 
# z_pos      57.000000    57.000000    56.000000    56.000000    58.000000    58.000000    55.000000    55.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       121          122          123          124          125          126          127          128      
#
# lambda for peak transmission
#          347.6990000  347.6990000  347.6990000  347.6990000  347.6990000  347.6990000  347.6990000  347.6990000 
# peak transmission
#            0.7684740    0.7663820    0.7673100    0.7695160    0.7662770    0.7658960    0.7655070    0.7634460 
# lambda blue with 1/2 of peak transmission
#          319.9606003  319.9134100  319.9442749  319.9835796  319.7936023  320.0144571  320.0468675  319.8400227 
# lambda red  with 1/2 of peak transmission
#          380.9557576  380.9553843  380.9954766  380.9815038  380.9703752  380.9540469  380.9626641  380.9827200 
# half width                              
#           60.9951573   61.0419743   61.0512018   60.9979242   61.1767728   60.9395897   60.9157967   61.1426972 
# central wavelength                      
#          350.4581789  350.4343972  350.4698757  350.4825417  350.3819887  350.4842520  350.5047658  350.4113713 
# central wavelength calculated as SAGEM (mean frequency)
#          347.8042180  347.7761802  347.8111242  347.8285245  347.7116192  347.8353216  347.8580584  347.7441995 
# lambda blue with 80% of peak transmission
#          323.3594455  323.3266651  323.3470813  323.3984936  323.3126453  323.4412331  323.4691156  323.3725622 
# lambda red  with 80% of peak transmission
#          372.1256042  372.1400411  372.1749174  372.1159690  372.1318262  372.0438437  372.1242967  372.2212842 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.7197278    0.7187457    0.7202222    0.7206242    0.7176698    0.7161379    0.7163593    0.7153359 
# ATB calculated from points above 50%
#            0.6739208    0.6732249    0.6744875    0.6746219    0.6728313    0.6700893    0.6701600    0.6704698 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 350.381989 at column =  6, at id = 125 
# maxCWL      = 350.504766 at column =  8, at id = 127 
# difference =    0.1227770 
# minBW       = 60.915797 at column =  8, at id = 127 
# maxBW       = 61.176773 at column =  6, at id = 125 
# difference =    0.2609761 
# minATB80    = 0.715336 at column =  9, at id = 128 
# maxATB80    = 0.720624 at column =  5, at id = 124 
# difference =    0.0052883 
# minBlueEdge = 319.793602 at column =  6, at id = 125 
# maxBlueEdge = 320.046867 at column =  8, at id = 127 
# difference =    0.2532651 
# minRedEdge  = 380.954047 at column =  7, at id = 126 
# maxRedEdge  = 380.995477 at column =  4, at id = 123 
# difference =    0.0414297 
# minABR      = 9.999900 at column =  2, at id = 121 
# maxABR      = 9.999900 at column =  2, at id = 121 
# difference =    0.0000000 
  299.645    -0.000247    -0.000183    -0.000163     0.000003     0.000479    -0.000174    -0.000007     0.000561 
  302.654    -0.000042    -0.000050    -0.000020     0.000001     0.000063    -0.000047    -0.000025     0.000061 
  305.662    -0.000034    -0.000001    -0.000097    -0.000048     0.000009     0.000034     0.000035    -0.000004 
  308.671     0.000012    -0.000053    -0.000051    -0.000026     0.000040    -0.000034     0.000016     0.000014 
  311.679     0.000023     0.000013    -0.000027    -0.000007     0.000057    -0.000014     0.000013    -0.000029 
  314.687     0.000634     0.000807     0.000682     0.000293     0.000928     0.000691     0.000704     0.000927 
  317.694     0.083226     0.089342     0.084248     0.080011     0.109139     0.078523     0.077537     0.104824 
  320.702     0.482697     0.487600     0.484473     0.480381     0.501685     0.473148     0.467738     0.492943 
  323.709     0.632153     0.631388     0.631550     0.631185     0.629925     0.626360     0.624947     0.625599 
  326.716     0.659335     0.658162     0.660105     0.660568     0.653657     0.653516     0.653856     0.652300 
  329.665     0.694918     0.694970     0.695467     0.695915     0.692817     0.689588     0.688709     0.689662 
  332.672     0.721009     0.720166     0.722104     0.722217     0.718031     0.715957     0.715482     0.714656 
  335.678     0.739608     0.738777     0.741043     0.741235     0.736819     0.735240     0.735421     0.733409 
  338.683     0.750811     0.750194     0.751512     0.752816     0.748062     0.745787     0.746033     0.744539 
  341.689     0.750457     0.749032     0.750562     0.751037     0.748071     0.745856     0.745816     0.744958 
  344.694     0.757781     0.756702     0.758227     0.758400     0.754964     0.754644     0.754454     0.752818 
  347.699     0.768474     0.766382     0.767310     0.769516     0.766277     0.765896     0.765507     0.763446 
  350.703     0.765835     0.764455     0.766833     0.767120     0.764370     0.762816     0.763219     0.761419 
  353.707     0.766811     0.765759     0.767129     0.767021     0.765629     0.763578     0.764135     0.762823 
  356.711     0.756320     0.755202     0.756541     0.756695     0.754560     0.754554     0.755031     0.752524 
  359.715     0.735769     0.734953     0.737580     0.737216     0.735814     0.733554     0.734616     0.734283 
  362.718     0.727766     0.727179     0.728665     0.728562     0.727011     0.726166     0.726649     0.725952 
  365.721     0.709707     0.708671     0.709580     0.710260     0.708265     0.707967     0.709293     0.707062 
  368.724     0.674733     0.674223     0.675521     0.676255     0.673617     0.672734     0.673301     0.673058 
  371.726     0.623425     0.622021     0.623589     0.624136     0.622044     0.619647     0.621140     0.621740 
  374.728     0.558474     0.557380     0.558449     0.558524     0.555303     0.554192     0.555308     0.555169 
  377.730     0.486610     0.485935     0.486807     0.486609     0.483039     0.482239     0.483989     0.482964 
  380.788     0.394922     0.393865     0.396449     0.396660     0.394723     0.393657     0.393927     0.393746 
  383.789     0.203779     0.202493     0.211393     0.212075     0.204099     0.200111     0.201949     0.208449 
  386.789     0.027151     0.026644     0.029718     0.029914     0.025836     0.025067     0.026355     0.028631 
  389.790     0.001484     0.001447     0.001604     0.001626     0.001386     0.001354     0.001459     0.001561 
  392.790     0.000134     0.000126     0.000121     0.000128     0.000128     0.000113     0.000128     0.000143 
  395.790     0.000001     0.000004    -0.000003     0.000002    -0.000002     0.000003     0.000005     0.000007 
  398.789     0.000004     0.000002     0.000004     0.000006     0.000001     0.000005     0.000005     0.000005 
  401.788     0.000002     0.000001     0.000000     0.000002     0.000000     0.000003     0.000002     0.000001 
  404.787     0.000001    -0.000001    -0.000001     0.000002    -0.000001     0.000001     0.000003     0.000002 
  407.785     0.000002    -0.000001    -0.000001    -0.000001    -0.000001    -0.000000     0.000002     0.000001 
  410.783     0.000001    -0.000000     0.000001     0.000001    -0.000001    -0.000000     0.000002    -0.000000 
  413.781     0.000001    -0.000001     0.000000     0.000001    -0.000001    -0.000000     0.000001     0.000001 
  416.834     0.000000    -0.000001     0.000000     0.000001    -0.000001    -0.000000    -0.000001    -0.000000 
  419.831     0.000000    -0.000000     0.000001     0.000000    -0.000000    -0.000001     0.000002     0.000001 
