# number of points on sci filter + aux + bad z = 13
# number of points on sci filter               = 13
# number of positions in lambda                = 301
# noof scans  1            1            1            1            1            1            1            1            1            1            1            1            1          
# x_pos       0.000000    17.670000   -17.670000   -17.670000    17.670000    35.340000   -35.340000   -35.340000    35.340000    53.010000   -53.010000   -53.010000    53.010000 
# y_pos       0.000000    17.670000    17.670000   -17.670000   -17.670000    35.340000    35.340000   -35.340000   -35.340000    53.010000    53.010000   -53.010000   -53.010000 
# angle       1.780000     1.840000     1.320000     1.840000     2.230000     2.000000     0.870000     2.000000     2.690000     2.230000     0.410000     2.230000     3.140000 
# z_pos      44.000000    45.000000    43.000000    45.000000    47.000000    46.000000    42.000000    46.000000    48.000000    47.000000    41.000000    47.000000    49.000000 
# r_pos       0.000000    24.990000    24.990000    24.990000    24.990000    49.980000    49.980000    49.980000    49.980000    74.970000    74.970000    74.970000    74.970000 
# phi         0.000000     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602 
# gnupl col      2            3            4            5            6            7            8            9           10           11           12           13           14      
# pos_id       402          403          404          405          406          407          408          409          410          411          412          413          414      
#
# lambda for peak transmission
#          536.9680000  536.9680000  536.9680000  536.9680000  536.9680000  536.9680000  536.9680000  536.9680000  536.9680000  536.9680000  536.9680000  536.9680000  536.9680000 
# peak transmission
#            0.9247400    0.9255230    0.9254710    0.9255620    0.9254170    0.9242160    0.9223150    0.9230680    0.9208310    0.9174940    0.9210570    0.9165410    0.9155080 
# lambda blue with 1/2 of peak transmission
#          411.1679809  411.5790606  411.5647089  411.6110685  411.5896111  409.8402140  409.8699020  409.8797069  409.8097885  409.5349813  409.5976056  409.6107857  409.4938225 
# lambda red  with 1/2 of peak transmission
#          544.5354922  545.1072560  545.1122522  545.0822086  545.0763120  542.8562649  543.0872671  542.8595384  542.6936910  542.5296769  542.8212877  542.5583040  542.3720452 
# half width                              
#          133.3675113  133.5281954  133.5475433  133.4711401  133.4867009  133.0160509  133.2173651  132.9798315  132.8839024  132.9946955  133.2236821  132.9475183  132.8782227 
# central wavelength                      
#          477.8517365  478.3431583  478.3384805  478.3466385  478.3329615  476.3482394  476.4785845  476.3696227  476.2517398  476.0323291  476.2094467  476.0845449  475.9329338 
# central wavelength calculated as SAGEM (mean frequency)
#          468.5460818  469.0246499  469.0171803  469.0361596  469.0200452  467.0623492  467.1671134  467.0892054  466.9824132  466.7432599  466.8918294  466.8030828  466.6581911 
# lambda blue with 80% of peak transmission
#          413.4865916  413.7050911  413.6984512  413.7210861  413.7108851  412.7724034  412.8127834  412.8266663  412.7606047  412.4815598  412.5628426  412.5679602  412.4239963 
# lambda red  with 80% of peak transmission
#          542.3173094  543.2125078  543.2236652  543.1957612  543.1857551  540.7670450  540.8964024  540.7679041  540.6550350  540.5262545  540.7185264  540.5564682  540.4164811 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.8771599    0.8750432    0.8748494    0.8742915    0.8743807    0.8755980    0.8735620    0.8728902    0.8715944    0.8704878    0.8740145    0.8685518    0.8674581 
# ATB calculated from points above 50%
#            0.8728667    0.8750432    0.8748494    0.8742915    0.8743807    0.8692315    0.8582644    0.8664306    0.8653789    0.8651859    0.8684823    0.8630440    0.8623291 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 475.932934 at column = 14, at id = 414 
# maxCWL      = 478.346639 at column =  5, at id = 405 
# difference =    2.4137047 
# minBW       = 132.878223 at column = 14, at id = 414 
# maxBW       = 133.547543 at column =  4, at id = 404 
# difference =    0.6693207 
# minATB80    = 0.867458 at column = 14, at id = 414 
# maxATB80    = 0.877160 at column =  2, at id = 402 
# difference =    0.0097018 
# minBlueEdge = 409.493823 at column = 14, at id = 414 
# maxBlueEdge = 411.611068 at column =  5, at id = 405 
# difference =    2.1172460 
# minRedEdge  = 542.372045 at column = 14, at id = 414 
# maxRedEdge  = 545.112252 at column =  4, at id = 404 
# difference =    2.7402070 
# minABR      = 9.999900 at column =  2, at id = 402 
# maxABR      = 9.999900 at column =  2, at id = 402 
# difference =    0.0000000 
  299.645    -0.000548     0.000165    -0.000114     0.000200    -0.000006    -0.000316    -0.000671    -0.000038    -0.000036     0.000086    -0.000079    -0.000070     0.000624 
  302.654    -0.000193     0.000019    -0.000105     0.000104    -0.000177    -0.000085    -0.000105    -0.000135     0.000116    -0.000002     0.000077    -0.000043     0.000141 
  305.662    -0.000108     0.000022    -0.000079     0.000091    -0.000077    -0.000259    -0.000118    -0.000043     0.000008    -0.000050    -0.000011    -0.000022     0.000046 
  308.671    -0.000059    -0.000057    -0.000020     0.000019    -0.000010     0.000015    -0.000056     0.000005    -0.000003     0.000017     0.000018     0.000011     0.000041 
  311.679     0.000020     0.000012    -0.000044     0.000036    -0.000050     0.000004    -0.000065    -0.000017    -0.000010     0.000013    -0.000026     0.000002     0.000025 
  314.687    -0.000005    -0.000030    -0.000030    -0.000005    -0.000040    -0.000025    -0.000081    -0.000008     0.000009     0.000027     0.000006    -0.000004    -0.000001 
  317.694    -0.000031    -0.000006    -0.000010     0.000029    -0.000014     0.000012    -0.000062    -0.000002     0.000027     0.000004     0.000028     0.000001     0.000003 
  320.702    -0.000030    -0.000021    -0.000009    -0.000007     0.000004     0.000010    -0.000037    -0.000002     0.000022    -0.000000    -0.000018     0.000005    -0.000005 
  323.709     0.000000    -0.000025    -0.000007    -0.000013    -0.000004     0.000026    -0.000041    -0.000005     0.000016     0.000013     0.000010     0.000007     0.000015 
  326.716     0.000003    -0.000024    -0.000024    -0.000011     0.000003     0.000010    -0.000050    -0.000007     0.000002     0.000005    -0.000008    -0.000010    -0.000004 
  329.665     0.000005    -0.000026    -0.000011     0.000008    -0.000005    -0.000013    -0.000043    -0.000001    -0.000006     0.000005     0.000003    -0.000002     0.000011 
  332.672    -0.000008    -0.000012    -0.000005    -0.000006     0.000006     0.000001    -0.000020     0.000010     0.000001     0.000010     0.000013    -0.000010     0.000010 
  335.678    -0.000002    -0.000014     0.000005    -0.000007    -0.000010    -0.000001    -0.000008     0.000015     0.000011     0.000009     0.000008    -0.000018     0.000009 
  338.683     0.000005    -0.000014    -0.000002     0.000000    -0.000009     0.000008    -0.000016     0.000006    -0.000002    -0.000000    -0.000001    -0.000001     0.000006 
  341.689    -0.000003    -0.000000    -0.000002     0.000006    -0.000008     0.000016    -0.000015     0.000013     0.000002     0.000010    -0.000008     0.000000     0.000007 
  344.694    -0.000006    -0.000010    -0.000003    -0.000004    -0.000007     0.000013    -0.000012     0.000006    -0.000001     0.000014    -0.000011     0.000000    -0.000003 
  347.699    -0.000003     0.000003    -0.000005    -0.000005    -0.000005     0.000009    -0.000016     0.000003     0.000008     0.000012    -0.000003    -0.000002     0.000002 
  350.703     0.000001     0.000001    -0.000000     0.000003    -0.000001     0.000009    -0.000011    -0.000003     0.000001     0.000003     0.000003     0.000002     0.000003 
  353.707     0.000002    -0.000004    -0.000001     0.000004    -0.000006     0.000009    -0.000012     0.000002    -0.000000     0.000004    -0.000001     0.000001     0.000005 
  356.711    -0.000001    -0.000004     0.000001     0.000006    -0.000001     0.000001    -0.000008     0.000004     0.000004     0.000007     0.000001     0.000001     0.000006 
  359.715    -0.000002    -0.000001     0.000002     0.000003    -0.000005     0.000003    -0.000002     0.000003     0.000006     0.000011     0.000001    -0.000002     0.000008 
  362.718    -0.000001    -0.000001    -0.000000     0.000005    -0.000003     0.000006    -0.000002     0.000008     0.000003     0.000006     0.000002     0.000001     0.000009 
  365.721     0.000000    -0.000004     0.000004     0.000001    -0.000006     0.000007    -0.000005     0.000006     0.000000     0.000003    -0.000001     0.000001     0.000008 
  368.724     0.000000    -0.000003    -0.000001     0.000003     0.000001     0.000007    -0.000003     0.000004     0.000002     0.000006    -0.000002     0.000002     0.000007 
  371.726    -0.000001    -0.000000    -0.000000     0.000002    -0.000002     0.000007    -0.000001     0.000003     0.000004     0.000001     0.000001     0.000000     0.000007 
  374.728     0.000003    -0.000000     0.000003     0.000001    -0.000001     0.000006    -0.000003     0.000002     0.000003     0.000003     0.000002     0.000002     0.000007 
  377.730    -0.000001    -0.000000     0.000002    -0.000000    -0.000002     0.000006    -0.000002     0.000001     0.000005     0.000005     0.000001     0.000003     0.000005 
  380.788    -0.000002    -0.000002     0.000003     0.000002     0.000001     0.000006    -0.000000    -0.000001    -0.000001     0.000002     0.000004     0.000003     0.000007 
  383.789    -0.000001    -0.000001     0.000001     0.000001    -0.000000     0.000006     0.000000     0.000001     0.000000     0.000003     0.000005     0.000004     0.000004 
  386.789     0.000001    -0.000000     0.000002     0.000002     0.000001     0.000005    -0.000000     0.000003     0.000002     0.000002     0.000002     0.000001     0.000003 
  389.790     0.000001     0.000004     0.000003     0.000003     0.000001     0.000007     0.000000     0.000005     0.000005     0.000008     0.000007     0.000025     0.000010 
  392.790     0.000046     0.000051     0.000049     0.000050     0.000037     0.000049     0.000061     0.000061     0.000058     0.000077     0.000057     0.000069     0.000062 
  395.790     0.000093     0.000090     0.000099     0.000088     0.000088     0.000144     0.000169     0.000151     0.000153     0.000187     0.000178     0.000184     0.000177 
  398.789     0.000422     0.000323     0.000341     0.000324     0.000329     0.000830     0.000826     0.000813     0.000848     0.001000     0.000995     0.000939     0.001017 
  401.788     0.002236     0.001851     0.001890     0.001825     0.001826     0.004133     0.004039     0.003969     0.004139     0.005006     0.004880     0.004677     0.005117 
  404.787     0.010646     0.008910     0.009063     0.008773     0.008767     0.022615     0.021715     0.021787     0.023119     0.029662     0.027680     0.027241     0.031006 
  407.785     0.081427     0.064286     0.064963     0.062673     0.063627     0.172547     0.169016     0.167969     0.175025     0.209133     0.201182     0.197417     0.214391 
  410.783     0.416307     0.358797     0.361020     0.353811     0.357142     0.594938     0.589103     0.588127     0.597588     0.636762     0.630134     0.625747     0.641353 
  413.781     0.775018     0.750332     0.751118     0.748334     0.749510     0.812599     0.808806     0.808653     0.808425     0.808381     0.809881     0.806279     0.807702 
  416.834     0.832337     0.831847     0.831110     0.830386     0.831577     0.825259     0.822990     0.822202     0.819629     0.812453     0.815792     0.811016     0.810784 
  419.831     0.828371     0.829097     0.827354     0.826142     0.827818     0.824169     0.822449     0.821991     0.818587     0.817510     0.821146     0.816299     0.815659 
  422.828     0.826822     0.826882     0.825524     0.824107     0.825667     0.822793     0.820764     0.819497     0.817225     0.812894     0.816525     0.810401     0.810041 
  425.824     0.829950     0.830675     0.829773     0.828514     0.830347     0.824295     0.822027     0.820529     0.818398     0.815626     0.819232     0.811993     0.811835 
  428.820     0.832590     0.830599     0.830093     0.828191     0.829796     0.830815     0.828601     0.827864     0.826297     0.825654     0.829008     0.822276     0.822651 
  431.815     0.839345     0.838501     0.837618     0.837101     0.837298     0.836901     0.834918     0.833942     0.832609     0.828119     0.830359     0.825538     0.825546 
  434.810     0.838643     0.839541     0.839659     0.837751     0.837706     0.830545     0.830382     0.829589     0.826198     0.829807     0.832403     0.827297     0.826315 
  437.862     0.833444     0.831990     0.832720     0.830763     0.830987     0.832287     0.829913     0.829518     0.828035     0.825134     0.828892     0.821808     0.821403 
  440.856     0.854419     0.850988     0.851777     0.849919     0.851708     0.855353     0.853002     0.853129     0.852229     0.848290     0.850325     0.845436     0.845053 
  443.850     0.858189     0.858784     0.858847     0.857198     0.857544     0.852821     0.851032     0.850948     0.849454     0.850133     0.853771     0.847911     0.846600 
  446.844     0.851354     0.855326     0.855132     0.853752     0.854105     0.843603     0.841800     0.840556     0.840173     0.840728     0.843498     0.837305     0.836963 
  449.837     0.845693     0.844612     0.844861     0.843807     0.844081     0.856298     0.854535     0.852993     0.852871     0.854327     0.856498     0.852027     0.851037 
  452.830     0.857474     0.857774     0.858310     0.856834     0.856671     0.855373     0.853631     0.852265     0.851588     0.854945     0.857765     0.853066     0.851118 
  455.878     0.853928     0.857079     0.857305     0.856506     0.856525     0.853216     0.850417     0.847605     0.848938     0.849200     0.852586     0.846628     0.845198 
  458.870     0.855118     0.855149     0.855328     0.854425     0.854196     0.865293     0.862537     0.861604     0.861558     0.861650     0.864164     0.859440     0.858246 
  461.862     0.873079     0.870940     0.871262     0.871071     0.870377     0.872905     0.870546     0.869751     0.868491     0.866624     0.869397     0.864557     0.863088 
  464.853     0.881029     0.879617     0.879168     0.879816     0.879179     0.879244     0.876176     0.876621     0.875169     0.872600     0.875234     0.871016     0.869618 
  467.901     0.879178     0.880818     0.880502     0.880140     0.879519     0.877881     0.874286     0.874261     0.873415     0.872120     0.874811     0.870769     0.869542 
  470.891     0.882763     0.882617     0.881903     0.882058     0.881348     0.882321     0.879064     0.879479     0.878948     0.876048     0.879389     0.874972     0.874139 
  473.881     0.893031     0.892372     0.891639     0.892029     0.891486     0.892749     0.889701     0.890711     0.889503     0.884544     0.886271     0.882962     0.883057 
  476.871     0.900893     0.900880     0.900379     0.901524     0.900444     0.895785     0.893386     0.894227     0.892377     0.887401     0.890525     0.886552     0.884917 
  479.916     0.892268     0.894891     0.894941     0.895531     0.894291     0.887835     0.885046     0.884315     0.884130     0.879928     0.881972     0.877247     0.876525 
  482.905     0.901666     0.898809     0.898798     0.899140     0.898272     0.904631     0.901301     0.901860     0.902161     0.897484     0.898632     0.895667     0.895311 
  485.894     0.908732     0.910425     0.910003     0.911445     0.910094     0.904760     0.901741     0.902239     0.901973     0.896676     0.898500     0.894434     0.893370 
  488.882     0.905930     0.908190     0.907350     0.908150     0.907250     0.905043     0.902573     0.902270     0.903065     0.901044     0.902316     0.899512     0.898261 
  491.925     0.905824     0.909568     0.907705     0.908416     0.907493     0.907590     0.904773     0.904611     0.904520     0.902398     0.904849     0.900583     0.898981 
  494.913     0.913143     0.914589     0.913295     0.914005     0.913664     0.913563     0.910943     0.911482     0.910793     0.907394     0.909232     0.905700     0.904705 
  497.899     0.914244     0.916839     0.915772     0.916978     0.915988     0.914803     0.912165     0.912973     0.912056     0.911716     0.913369     0.910603     0.910050 
  500.942     0.912547     0.914253     0.913301     0.914297     0.913406     0.913397     0.911004     0.911917     0.910393     0.912369     0.914629     0.911998     0.910920 
  503.928     0.911491     0.914315     0.913631     0.913210     0.913854     0.905689     0.902773     0.903233     0.901664     0.901211     0.905892     0.900562     0.898779 
  506.913     0.899034     0.904451     0.903622     0.903027     0.903680     0.898462     0.894678     0.895125     0.894744     0.893760     0.898923     0.892417     0.891643 
  509.954     0.902690     0.902025     0.902421     0.900947     0.901921     0.912308     0.908413     0.909829     0.908987     0.913522     0.916397     0.912202     0.911877 
  512.939     0.903577     0.906864     0.906248     0.905107     0.906493     0.900963     0.899558     0.898764     0.896770     0.907907     0.913453     0.907556     0.904811 
  515.923     0.879990     0.885639     0.886032     0.884885     0.885301     0.874472     0.875303     0.872506     0.869794     0.883421     0.889593     0.881837     0.880131 
  518.963     0.875017     0.874698     0.874750     0.873323     0.873949     0.880212     0.880015     0.876674     0.876946     0.882005     0.886900     0.879117     0.878718 
  521.946     0.892401     0.891037     0.890962     0.890958     0.891343     0.894022     0.892430     0.890736     0.891023     0.889879     0.893643     0.886628     0.886968 
  524.929     0.902423     0.903242     0.903187     0.903098     0.903941     0.900734     0.898588     0.897562     0.897734     0.897882     0.901446     0.894873     0.894800 
  527.967     0.902499     0.903407     0.903819     0.903945     0.904550     0.903783     0.901086     0.900410     0.900455     0.902739     0.906061     0.899135     0.899721 
  530.949     0.911155     0.909763     0.910209     0.910284     0.910128     0.914135     0.912465     0.912401     0.911355     0.911060     0.914105     0.908450     0.909173 
  533.987     0.920877     0.921393     0.922023     0.922592     0.922119     0.919927     0.917521     0.917878     0.916933     0.913736     0.916548     0.910675     0.911919 
  536.968     0.924740     0.925523     0.925471     0.925562     0.925417     0.924216     0.922315     0.923068     0.920831     0.917494     0.921057     0.916541     0.915508 
  539.948     0.915977     0.923732     0.924882     0.924027     0.923868     0.848070     0.858072     0.847005     0.832472     0.813441     0.838098     0.816809     0.798203 
  542.984     0.690216     0.773904     0.775610     0.771619     0.769961     0.445156     0.473227     0.445056     0.421077     0.396328     0.439147     0.399799     0.371807 
  545.964     0.252585     0.337214     0.337520     0.332989     0.332353     0.113135     0.124935     0.112620     0.105200     0.097549     0.115271     0.098494     0.088871 
  548.999     0.053634     0.074270     0.074923     0.073330     0.073093     0.023545     0.026219     0.023428     0.021841     0.020203     0.024211     0.020393     0.018303 
  551.977     0.011109     0.015791     0.015958     0.015657     0.015547     0.004542     0.005040     0.004501     0.004217     0.003951     0.004729     0.003963     0.003610 
  555.012     0.002310     0.003063     0.003087     0.003030     0.003017     0.001286     0.001414     0.001271     0.001201     0.001182     0.001372     0.001172     0.001100 
  557.989     0.000825     0.001028     0.001047     0.001017     0.001010     0.000472     0.000523     0.000465     0.000435     0.000424     0.000502     0.000426     0.000396 
  561.023     0.000299     0.000374     0.000379     0.000371     0.000366     0.000183     0.000200     0.000180     0.000168     0.000170     0.000195     0.000168     0.000155 
  563.999     0.000127     0.000154     0.000156     0.000151     0.000148     0.000069     0.000084     0.000070     0.000066     0.000068     0.000084     0.000064     0.000065 
  567.032     0.000045     0.000059     0.000063     0.000056     0.000056     0.000031     0.000035     0.000030     0.000030     0.000031     0.000033     0.000032     0.000028 
  570.007     0.000026     0.000027     0.000030     0.000026     0.000031     0.000023     0.000022     0.000018     0.000019     0.000021     0.000025     0.000018     0.000019 
  573.038     0.000016     0.000020     0.000020     0.000019     0.000018     0.000002     0.000002     0.000002     0.000005     0.000006     0.000010     0.000001     0.000001 
  576.013     0.000002     0.000006     0.000000     0.000006     0.000001     0.000003     0.000001     0.000003     0.000004     0.000002     0.000010     0.000003     0.000003 
  579.043     0.000003     0.000001     0.000001     0.000005     0.000002     0.000002     0.000002     0.000002     0.000002     0.000003    -0.000002     0.000002     0.000002 
  582.017     0.000003     0.000002     0.000002     0.000000     0.000002     0.000002     0.000002     0.000002     0.000002     0.000003    -0.000001     0.000002     0.000001 
  585.046     0.000002     0.000001     0.000002     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002     0.000002     0.000001     0.000002 
  588.019     0.000002     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  591.047     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001 
  594.019     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  597.046     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001 
  600.073     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001 
  603.043     0.000001     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001 
  606.068     0.000002     0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001 
  609.038     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  612.062     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001 
  615.086     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001 
  618.053     0.000002     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000000 
  621.076     0.000001    -0.000000     0.000000     0.000000    -0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000001 
  624.099     0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000 
  627.064     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000000    -0.000000     0.000000 
  630.086     0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000    -0.000000 
  633.106     0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001 
  636.071    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000001     0.000001     0.000000    -0.000000     0.000000 
  639.090    -0.000000    -0.000001    -0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000 
  642.109    -0.000000    -0.000001     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000 
  645.128     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000 
  648.090     0.000000    -0.000001     0.000000    -0.000000    -0.000001    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000 
  651.107     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001 
  654.123     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000000     0.000000     0.000001 
  657.139     0.000000    -0.000000     0.000001    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000001     0.000000    -0.000000     0.000001 
  660.099    -0.000000    -0.000000     0.000001    -0.000001    -0.000001    -0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  663.114    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000 
  666.129     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000001    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000 
  669.142     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000001     0.000000     0.000001     0.000000 
  672.155     0.000001    -0.000000    -0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000 
  675.168     0.000001    -0.000001     0.000001    -0.000001    -0.000000    -0.000000    -0.000000     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000 
  678.124     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000001    -0.000001     0.000000 
  681.136    -0.000000    -0.000000     0.000000    -0.000001    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000001    -0.000001     0.000000 
  684.146     0.000000    -0.000001     0.000001     0.000000    -0.000001    -0.000000    -0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000 
  687.157     0.000000     0.000000     0.000001    -0.000001    -0.000000     0.000000    -0.000001     0.000000    -0.000000    -0.000001     0.000001     0.000001     0.000001 
  690.166    -0.000001    -0.000001     0.000000     0.000000    -0.000001     0.000001    -0.000000     0.000000    -0.000000    -0.000000     0.000006     0.000001     0.000000 
  693.175     0.000001     0.000001     0.000001     0.000001    -0.000001     0.000002     0.000007     0.000009     0.000008     0.000012     0.000011     0.000009     0.000012 
  696.183     0.000003     0.000002     0.000002     0.000002     0.000001     0.000001     0.000001     0.000002     0.000001    -0.000001     0.000000    -0.000001    -0.000001 
  699.191     0.000002     0.000002     0.000003     0.000002     0.000003     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000001     0.000007 
  702.198     0.000001     0.000001     0.000002     0.000002     0.000001     0.000002     0.000008     0.000003     0.000002     0.000002     0.000004     0.000002     0.000001 
  705.205     0.000003     0.000002     0.000003     0.000004     0.000002     0.000002    -0.000000     0.000003     0.000003     0.000003     0.000004     0.000002     0.000001 
  708.211     0.000002     0.000001     0.000003     0.000004     0.000002    -0.000000    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000 
  711.216     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000001     0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000000 
  714.220     0.000000    -0.000001     0.000000     0.000001    -0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000002 
  717.224     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001 
  720.228     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000001     0.000002     0.000002     0.000002     0.000002 
  723.230     0.000004     0.000001     0.000002     0.000002     0.000003     0.000001     0.000002     0.000001     0.000001     0.000002     0.000002     0.000003     0.000001 
  726.232     0.000002     0.000001     0.000002     0.000001     0.000002    -0.000001    -0.000000     0.000000    -0.000000     0.000001     0.000000     0.000002     0.000001 
  729.234     0.000001     0.000000    -0.000000     0.000001     0.000000    -0.000001    -0.000001    -0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000000 
  732.234     0.000000    -0.000000     0.000000     0.000001    -0.000001    -0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000000 
  735.235     0.000000    -0.000000    -0.000001     0.000001    -0.000000    -0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000002     0.000001     0.000001 
  738.234     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000003     0.000002     0.000001 
  741.233     0.000002     0.000001     0.000002     0.000003     0.000003     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000001     0.000000 
  744.231     0.000000     0.000001     0.000000     0.000002     0.000002    -0.000000    -0.000000     0.000002    -0.000000     0.000001     0.000001     0.000001    -0.000000 
  747.228    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000001    -0.000000     0.000002     0.000001     0.000001     0.000001     0.000001    -0.000001 
  750.225     0.000000     0.000000     0.000000     0.000001    -0.000001    -0.000000    -0.000001     0.000001    -0.000001     0.000001     0.000001     0.000002    -0.000000 
  753.221    -0.000001    -0.000000     0.000001     0.000001     0.000000    -0.000000    -0.000000     0.000001    -0.000001     0.000001     0.000001     0.000000    -0.000001 
  756.272    -0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000     0.000002     0.000000     0.000001     0.000002     0.000002     0.000001 
  759.267     0.000009     0.000001     0.000001     0.000001     0.000001     0.000003     0.000004     0.000003     0.000002     0.000003     0.000004     0.000003     0.000004 
  762.261     0.000000     0.000002     0.000003     0.000003     0.000003     0.000004     0.000003     0.000003     0.000002     0.000003     0.000004     0.000003     0.000002 
  765.254     0.000003     0.000001     0.000002     0.000004     0.000003     0.000000    -0.000001     0.000002    -0.000000    -0.000000     0.000001     0.000001     0.000001 
  768.247     0.000002    -0.000001     0.000001     0.000001    -0.000000     0.000001    -0.000001     0.000001    -0.000000     0.000001     0.000002     0.000001     0.000001 
  771.294     0.000002     0.000000     0.000001     0.000001    -0.000001     0.000020     0.000020     0.000025     0.000022     0.000029     0.000030     0.000027     0.000031 
  774.286     0.000027     0.000013     0.000013     0.000022     0.000019     0.000155     0.000151     0.000146     0.000159     0.000242     0.000236     0.000225     0.000254 
  777.277     0.000219     0.000121     0.000121     0.000116     0.000128     0.000307     0.000342     0.000298     0.000286     0.000336     0.000393     0.000327     0.000295 
  780.266     0.000183     0.000288     0.000296     0.000285     0.000287     0.000046     0.000046     0.000049     0.000048     0.000053     0.000061     0.000057     0.000054 
  783.311     0.000041     0.000051     0.000052     0.000055     0.000053     0.000036     0.000031     0.000032     0.000035     0.000028     0.000043     0.000033     0.000032 
  786.300     0.000030     0.000040     0.000042     0.000038     0.000038     0.000006     0.000005     0.000003     0.000002     0.000003     0.000005     0.000004     0.000001 
  789.288     0.000001    -0.000001     0.000013     0.000004     0.000001     0.000004     0.000002     0.000004     0.000002     0.000003     0.000003     0.000003     0.000002 
  792.275     0.000002     0.000003     0.000002     0.000004     0.000003     0.000003    -0.000001     0.000003     0.000001     0.000001     0.000001     0.000002     0.000001 
  795.316     0.000001    -0.000001     0.000002     0.000000     0.000000     0.000001    -0.000001     0.000002     0.000000     0.000001     0.000000     0.000000     0.000000 
  798.302     0.000000    -0.000001     0.000002     0.000000     0.000000     0.000001    -0.000001    -0.000000    -0.000001     0.000001     0.000001     0.000001    -0.000000 
  801.287     0.000001    -0.000002     0.000001     0.000001     0.000000     0.000002    -0.000000     0.000002    -0.000000     0.000002     0.000002     0.000002     0.000001 
  804.327     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000002     0.000000     0.000003     0.000000     0.000003     0.000004     0.000014     0.000003 
  807.310     0.000021     0.000001     0.000003     0.000003     0.000001     0.000003     0.000013     0.000005     0.000012     0.000007     0.000016     0.000007     0.000005 
  810.348     0.000021     0.000003     0.000005     0.000017     0.000003     0.000028     0.000029     0.000023     0.000029     0.000034     0.000035     0.000031     0.000026 
  813.331     0.000025     0.000028     0.000026     0.000027     0.000027     0.000040     0.000045     0.000039     0.000029     0.000040     0.000042     0.000033     0.000034 
  816.312     0.000029     0.000034     0.000033     0.000034     0.000025     0.000036     0.000041     0.000034     0.000028     0.000042     0.000045     0.000032     0.000031 
  819.348     0.000031     0.000034     0.000040     0.000034     0.000034     0.000034     0.000028     0.000028     0.000025     0.000033     0.000029     0.000027     0.000029 
  822.328     0.000027     0.000028     0.000028     0.000020     0.000026     0.000002     0.000002     0.000006     0.000001     0.000005     0.000001     0.000002     0.000002 
  825.362     0.000004     0.000003     0.000003     0.000002    -0.000000     0.000003     0.000002     0.000004     0.000002     0.000003     0.000003     0.000002     0.000002 
  828.341     0.000003     0.000004     0.000003     0.000004     0.000002    -0.000001    -0.000000     0.000002     0.000000     0.000001     0.000001     0.000002     0.000001 
  831.374     0.000002     0.000001    -0.000000     0.000002     0.000000    -0.000001    -0.000001     0.000003    -0.000000     0.000002     0.000001     0.000001     0.000000 
  834.351     0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000001    -0.000001     0.000001    -0.000000     0.000003     0.000001     0.000002    -0.000000 
  837.382     0.000002     0.000001    -0.000000     0.000001    -0.000000     0.000002    -0.000001     0.000001    -0.000001     0.000002     0.000001     0.000003     0.000000 
  840.357     0.000001     0.000000     0.000001     0.000000     0.000002     0.000002     0.000002     0.000005     0.000002     0.000004     0.000003     0.000003     0.000002 
  843.387     0.000005     0.000013     0.000015     0.000003     0.000004     0.000004     0.000005     0.000006     0.000004     0.000007     0.000003     0.000004     0.000004 
  846.361     0.000006     0.000008     0.000004     0.000006     0.000007     0.000005     0.000004     0.000006     0.000004     0.000005     0.000005     0.000004     0.000005 
  849.389     0.000005     0.000005     0.000006     0.000006     0.000006     0.000005     0.000015     0.000007     0.000017     0.000019     0.000029     0.000017     0.000028 
  852.362     0.000006     0.000005     0.000005     0.000005     0.000005     0.000006     0.000022     0.000009     0.000017     0.000013     0.000027     0.000027     0.000026 
  855.389     0.000008     0.000005     0.000006     0.000006     0.000007    -0.000001    -0.000000     0.000009    -0.000001     0.000000     0.000003     0.000001     0.000003 
  858.359     0.000006     0.000004     0.000007     0.000007     0.000007     0.000002     0.000001     0.000004     0.000003     0.000004     0.000003     0.000003     0.000002 
  861.385     0.000003     0.000001     0.000003     0.000003     0.000004     0.000001     0.000000     0.000002     0.000002     0.000002     0.000000     0.000002     0.000001 
  864.409     0.000002    -0.000001     0.000001    -0.000001     0.000001     0.000001    -0.000002     0.000001    -0.000001    -0.000000     0.000000     0.000000     0.000000 
  867.378     0.000000    -0.000002     0.000001     0.000000    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000 
  870.400     0.000001    -0.000001    -0.000001    -0.000001     0.000000     0.000001    -0.000001     0.000001    -0.000001     0.000002     0.000000     0.000001     0.000000 
  873.422     0.000001    -0.000001     0.000001    -0.000001     0.000000     0.000001    -0.000002     0.000002    -0.000001    -0.000000     0.000000    -0.000000     0.000000 
  876.389     0.000001    -0.000002    -0.000000     0.000001     0.000000     0.000001    -0.000002     0.000003    -0.000000     0.000000    -0.000001     0.000001     0.000000 
  879.409     0.000002    -0.000000    -0.000000     0.000000     0.000002    -0.000000    -0.000000     0.000001    -0.000001     0.000001    -0.000001     0.000000     0.000001 
  882.428     0.000001    -0.000001     0.000001     0.000000     0.000001    -0.000001    -0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001 
  885.447     0.000001    -0.000001    -0.000000     0.000000     0.000001    -0.000001    -0.000001     0.000001    -0.000002     0.000001    -0.000000    -0.000000     0.000001 
  888.410     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001    -0.000002     0.000001    -0.000001     0.000001     0.000000     0.000001    -0.000000 
  891.427     0.000001    -0.000001     0.000001     0.000001     0.000000     0.000000    -0.000001     0.000001    -0.000001     0.000002    -0.000001     0.000002     0.000000 
  894.444     0.000000    -0.000001    -0.000000     0.000001     0.000001    -0.000000    -0.000001     0.000001    -0.000000     0.000001    -0.000001     0.000001     0.000002 
  897.459     0.000001    -0.000001     0.000001     0.000001    -0.000000    -0.000000    -0.000001     0.000002    -0.000000     0.000001     0.000000     0.000001     0.000000 
  900.419     0.000001    -0.000001     0.000000     0.000000    -0.000000    -0.000001    -0.000001     0.000000    -0.000000     0.000001    -0.000000    -0.000000     0.000000 
  903.433     0.000002    -0.000001    -0.000000     0.000001    -0.000001     0.000001    -0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000 
  906.446     0.000001    -0.000001    -0.000001     0.000001     0.000001     0.000001    -0.000000     0.000002    -0.000001     0.000001     0.000000     0.000001    -0.000000 
  909.458     0.000001    -0.000001     0.000000     0.000001     0.000001     0.000001    -0.000001     0.000001    -0.000001     0.000000     0.000000     0.000000    -0.000000 
  912.469     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000000 
  915.480     0.000001    -0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  918.489     0.000001    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000 
  921.443     0.000001    -0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000001     0.000000    -0.000001     0.000000    -0.000000     0.000000    -0.000000 
  924.451     0.000001    -0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000000 
  927.458     0.000001    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000000 
  930.465     0.000001    -0.000001    -0.000000    -0.000000     0.000001     0.000000    -0.000001     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000000 
  933.470     0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000    -0.000001     0.000000    -0.000000     0.000001     0.000000 
  936.475     0.000001    -0.000000     0.000000     0.000001     0.000000     0.000000    -0.000001     0.000001    -0.000000    -0.000000    -0.000001     0.000001     0.000000 
  939.478     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000001    -0.000001 
  942.481     0.000001    -0.000001     0.000000    -0.000001     0.000001     0.000001    -0.000001     0.000001    -0.000000     0.000001    -0.000000     0.000001     0.000000 
  945.483     0.000001    -0.000001    -0.000001    -0.000001     0.000000    -0.000000    -0.000001     0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000000 
  948.484     0.000001    -0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000 
  951.484     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000    -0.000001     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000000 
  954.538     0.000000    -0.000001     0.000001     0.000001     0.000000     0.000001    -0.000000     0.000001    -0.000001     0.000001     0.000000    -0.000000    -0.000000 
  957.537     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000001     0.000001    -0.000000     0.000001     0.000001 
  960.534     0.000001    -0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001    -0.000001     0.000000    -0.000000     0.000000     0.000000 
  963.531     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000001     0.000000    -0.000001     0.000000    -0.000000     0.000000     0.000000 
  966.526     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000001     0.000000    -0.000001     0.000000     0.000000     0.000000    -0.000000 
  969.521     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
  972.515     0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000001    -0.000001    -0.000000    -0.000000     0.000001     0.000000     0.000000     0.000001 
  975.563     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000001     0.000000    -0.000001     0.000001     0.000000     0.000000     0.000000 
  978.555     0.000001    -0.000000    -0.000001     0.000001     0.000000     0.000000    -0.000001     0.000001    -0.000001     0.000001    -0.000000     0.000001    -0.000000 
  981.546     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000000 
  984.537     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000 
  987.580     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000 
  990.569     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001    -0.000000 
  993.556     0.000001    -0.000000    -0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000 
  996.543     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000001    -0.000000    -0.000000     0.000000 
  999.583     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000000 
 1002.568     0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000001    -0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000 
 1005.552     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000001     0.000000     0.000000    -0.000001     0.000001     0.000000     0.000001     0.000001 
 1008.589     0.000001    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000    -0.000000     0.000002     0.000001     0.000001     0.000002 
 1011.571     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000002     0.000001     0.000002     0.000009 
 1014.606     0.000001     0.000001     0.000000     0.000000     0.000002     0.000000     0.000000     0.000000     0.000001     0.000003     0.000001     0.000002     0.000008 
 1017.587     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000002     0.000002     0.000002     0.000004 
 1020.620     0.000000    -0.000000     0.000001     0.000000     0.000002     0.000000     0.000001     0.000001     0.000000     0.000002    -0.000001     0.000001     0.000002 
 1023.598     0.000001     0.000001    -0.000000    -0.000000     0.000001    -0.000001     0.000000     0.000000     0.000000     0.000002    -0.000000     0.000001     0.000001 
 1026.629     0.000001    -0.000001    -0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000002    -0.000000     0.000001     0.000000 
 1029.606     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000002    -0.000000     0.000000     0.000001 
 1032.635     0.000001    -0.000000    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000002     0.000001     0.000001    -0.000001 
 1035.610     0.000002    -0.000001     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000002     0.000001     0.000000    -0.000000 
 1038.637     0.000002    -0.000000    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000002     0.000000     0.000001     0.000001 
 1041.610     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000003     0.000002     0.000002     0.000011 
 1044.635     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001    -0.000001     0.000001     0.000001     0.000003     0.000002     0.000011     0.000021 
 1047.660     0.000002     0.000000     0.000000     0.000001     0.000001     0.000001    -0.000001     0.000001     0.000003     0.000004     0.000002     0.000002     0.000041 
 1050.629     0.000001     0.000001    -0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000004     0.000005     0.000003     0.000006     0.000033 
 1053.652     0.000001     0.000001    -0.000000     0.000002     0.000002     0.000002     0.000001     0.000002     0.000004     0.000005     0.000004     0.000007     0.000031 
 1056.620     0.000002     0.000000     0.000000     0.000001     0.000002     0.000002    -0.000000     0.000001     0.000004     0.000003     0.000005     0.000007     0.000028 
 1059.640     0.000002     0.000000     0.000000     0.000001     0.000002     0.000002    -0.000000     0.000002     0.000003     0.000005     0.000004     0.000007     0.000014 
 1062.660     0.000003    -0.000002     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000005     0.000005     0.000004     0.000006     0.000006 
 1065.678     0.000002    -0.000000     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000005     0.000005     0.000004     0.000006     0.000009 
 1068.642     0.000003     0.000002     0.000001     0.000000     0.000003     0.000001     0.000001     0.000000     0.000005     0.000006     0.000002     0.000006     0.000004 
 1071.658     0.000003     0.000001     0.000001     0.000001     0.000002    -0.000000    -0.000001    -0.000000     0.000006     0.000006     0.000006     0.000008     0.000011 
 1074.674     0.000002    -0.000001     0.000003     0.000000     0.000003     0.000003     0.000002     0.000002     0.000003     0.000007     0.000004     0.000009     0.000009 
 1077.688     0.000003    -0.000000     0.000002     0.000000     0.000003     0.000001     0.000002     0.000003     0.000006     0.000008     0.000006     0.000009     0.000009 
 1080.702     0.000002    -0.000001     0.000003     0.000001     0.000003     0.000004     0.000001     0.000004     0.000008     0.000007     0.000006     0.000009     0.000006 
 1083.660     0.000005     0.000001     0.000001     0.000002     0.000004     0.000001     0.000002     0.000004     0.000009     0.000011     0.000008     0.000009     0.000008 
 1086.672     0.000006     0.000004     0.000001     0.000002     0.000002     0.000004     0.000005     0.000002     0.000005     0.000009     0.000009     0.000013     0.000008 
 1089.682     0.000006     0.000002     0.000003     0.000005     0.000003     0.000004     0.000003     0.000006     0.000008     0.000013     0.000008     0.000013     0.000009 
 1092.691     0.000006    -0.000001     0.000004     0.000005     0.000007     0.000006     0.000005     0.000006     0.000007     0.000012     0.000010     0.000039     0.000012 
 1095.699     0.000010     0.000004     0.000005     0.000008     0.000007     0.000011     0.000009     0.000012     0.000011     0.000018     0.000014     0.000011     0.000014 
 1098.707     0.000015     0.000010     0.000009     0.000011     0.000014     0.000051     0.000049     0.000047     0.000020     0.000025     0.000049     0.000021     0.000046 
 1101.713     0.000086     0.000018     0.000054     0.000020     0.000016     0.000108     0.000076     0.000088     0.000077     0.000030     0.000076     0.000022     0.000041 
 1104.718     0.000092     0.000051     0.000066     0.000104     0.000101     0.000109     0.000110     0.000092     0.000102     0.000089     0.000101     0.000091     0.000089 
 1107.722     0.000132     0.000104     0.000109     0.000111     0.000118     0.000161     0.000155     0.000153     0.000123     0.000129     0.000136     0.000109     0.000114 
 1110.725     0.000155     0.000178     0.000153     0.000118     0.000163     0.000239     0.000217     0.000194     0.000204     0.000170     0.000139     0.000159     0.000145 
 1113.727     0.000261     0.000194     0.000205     0.000270     0.000271     0.000289     0.000342     0.000283     0.000301     0.000192     0.000210     0.000199     0.000198 
 1116.728     0.000375     0.000357     0.000369     0.000338     0.000359     0.000427     0.000432     0.000402     0.000399     0.000331     0.000352     0.000284     0.000269 
 1119.728     0.000519     0.000454     0.000427     0.000465     0.000407     0.000633     0.000684     0.000579     0.000615     0.000401     0.000437     0.000409     0.000402 
 1122.726     0.000802     0.000704     0.000735     0.000722     0.000704     0.000979     0.001008     0.000893     0.000925     0.000704     0.000739     0.000590     0.000629 
 1125.724     0.001252     0.001049     0.001082     0.000998     0.000988     0.001489     0.001594     0.001395     0.001435     0.001074     0.001161     0.000900     0.000928 
 1128.720     0.001965     0.001727     0.001741     0.001701     0.001729     0.002326     0.002505     0.002188     0.002239     0.001550     0.001749     0.001437     0.001425 
 1131.770     0.003092     0.002753     0.002805     0.002710     0.002765     0.003650     0.003918     0.003380     0.003436     0.002346     0.002616     0.002189     0.002183 
 1134.764     0.004963     0.004389     0.004519     0.004343     0.004396     0.005599     0.005926     0.005146     0.005312     0.003471     0.003857     0.003261     0.003258 
 1137.757     0.007671     0.006881     0.007123     0.006818     0.006874     0.008536     0.008945     0.007836     0.008111     0.005234     0.005739     0.004885     0.004878 
 1140.749     0.011820     0.010669     0.011021     0.010637     0.010565     0.013425     0.014120     0.012318     0.012748     0.008342     0.009006     0.007805     0.007773 
 1143.741     0.018328     0.016478     0.016955     0.016402     0.016300     0.021908     0.022902     0.020114     0.020923     0.013944     0.014910     0.012922     0.013169 
 1146.784     0.029470     0.025997     0.026658     0.025874     0.025686     0.036709     0.038356     0.033787     0.035131     0.024031     0.025746     0.022245     0.022746 
 1149.773     0.047729     0.042056     0.042830     0.041699     0.041484     0.060632     0.063362     0.055882     0.058003     0.040496     0.043896     0.037611     0.038433 
 1152.761     0.077052     0.067908     0.068773     0.067323     0.067201     0.096381     0.101410     0.088912     0.091947     0.065295     0.071809     0.060707     0.062084 
 1155.801     0.121470     0.108111     0.109215     0.106724     0.106776     0.147291     0.155811     0.136394     0.140225     0.101226     0.111923     0.094144     0.095690 
 1158.786     0.185138     0.166274     0.169006     0.164367     0.164736     0.218303     0.229858     0.202909     0.208480     0.150944     0.166104     0.140263     0.142851 
 1161.771     0.273248     0.247931     0.252064     0.244999     0.246603     0.313572     0.326608     0.292526     0.301031     0.216730     0.235631     0.202194     0.205532 
 1164.807     0.392329     0.360673     0.365582     0.357352     0.360123     0.434248     0.447289     0.408178     0.419643     0.302531     0.325333     0.284566     0.288492 
 1167.790     0.533675     0.500843     0.504921     0.498425     0.500737     0.561324     0.574202     0.534342     0.546209     0.407697     0.432835     0.387570     0.392069 
 1170.771     0.658621     0.637871     0.641689     0.636659     0.637747     0.653913     0.669583     0.633822     0.639322     0.518819     0.546370     0.499638     0.504146 
 1173.804     0.716468     0.719418     0.725414     0.717779     0.715368     0.684431     0.705727     0.675269     0.670777     0.613444     0.644177     0.599160     0.600783 
 1176.783     0.698758     0.715648     0.722587     0.714935     0.709813     0.666349     0.693932     0.666296     0.654556     0.672091     0.708357     0.664406     0.663235 
 1179.814     0.644345     0.662927     0.670145     0.659107     0.651181     0.632845     0.662244     0.640352     0.623055     0.700294     0.737849     0.698118     0.690935 
 1182.790     0.590832     0.601823     0.610635     0.597789     0.589319     0.611624     0.640517     0.617130     0.604835     0.705522     0.742362     0.703127     0.698608 
 1185.819     0.566309     0.564551     0.579048     0.561815     0.555336     0.600784     0.632363     0.604175     0.590346     0.695796     0.732027     0.689656     0.682008 
 1188.793     0.568477     0.556307     0.570344     0.553789     0.547728     0.601797     0.630559     0.601173     0.588511     0.664427     0.707713     0.657463     0.645251 
 1191.820     0.583804     0.566067     0.583804     0.567610     0.559293     0.599018     0.628689     0.591938     0.585371     0.617698     0.668435     0.610427     0.597117 
 1194.845     0.599162     0.591352     0.602474     0.588720     0.581873     0.590614     0.622972     0.584388     0.574799     0.577823     0.626973     0.575191     0.557315 
 1197.815     0.614423     0.609526     0.621287     0.609269     0.603286     0.584606     0.609296     0.575819     0.568526     0.549242     0.595597     0.537795     0.528275 
 1200.838     0.622467     0.620048     0.639104     0.619778     0.618419     0.588952     0.617006     0.580924     0.577787     0.540694     0.579101     0.532734     0.519204 