# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 78
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       2.110000     1.490000     1.490000     2.110000     2.500000     1.320000     1.320000     2.500000 
# z_pos      57.000000    56.000000    56.000000    57.000000    58.000000    55.000000    55.000000    58.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       421          422          423          424          425          426          427          428      
#
# lambda for peak transmission
#          536.9680000  536.9680000  536.9680000  536.9680000  536.9680000  536.9680000  536.9680000  536.9680000 
# peak transmission
#            0.9232120    0.9239220    0.9240030    0.9239130    0.9209010    0.9199990    0.9222790    0.9210280 
# lambda blue with 1/2 of peak transmission
#          411.5907667  411.4860857  411.5700086  411.6483193  409.7516993  409.8252580  409.8452694  409.8072998 
# lambda red  with 1/2 of peak transmission
#          545.0774018  544.9957827  545.0710880  545.1458548  542.6862323  542.8932761  542.8871000  542.6756269 
# half width                              
#          133.4866351  133.5096971  133.5010794  133.4975355  132.9345330  133.0680181  133.0418306  132.8683271 
# central wavelength                      
#          478.3340842  478.2409342  478.3205483  478.3970870  476.2189658  476.3592670  476.3661847  476.2414634 
# central wavelength calculated as SAGEM (mean frequency)
#          469.0211990  468.9230162  469.0053839  469.0839074  466.9419360  467.0663348  467.0770447  466.9741097 
# lambda blue with 80% of peak transmission
#          413.7044222  413.6483555  413.6984458  413.7425597  412.6907687  412.7618761  412.7934556  412.7557390 
# lambda red  with 80% of peak transmission
#          543.1897190  543.1243893  543.1896025  543.2498525  540.6489515  540.7849291  540.7822401  540.6475871 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.8725408    0.8734705    0.8729670    0.8729183    0.8716633    0.8722639    0.8732143    0.8708547 
# ATB calculated from points above 50%
#            0.8725408    0.8734705    0.8729670    0.8729183    0.8656469    0.8659630    0.8668502    0.8646583 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 476.218966 at column =  6, at id = 425 
# maxCWL      = 478.397087 at column =  5, at id = 424 
# difference =    2.1781213 
# minBW       = 132.868327 at column =  9, at id = 428 
# maxBW       = 133.509697 at column =  3, at id = 422 
# difference =    0.6413699 
# minATB80    = 0.870855 at column =  9, at id = 428 
# maxATB80    = 0.873471 at column =  3, at id = 422 
# difference =    0.0026158 
# minBlueEdge = 409.751699 at column =  6, at id = 425 
# maxBlueEdge = 411.648319 at column =  5, at id = 424 
# difference =    1.8966200 
# minRedEdge  = 542.675627 at column =  9, at id = 428 
# maxRedEdge  = 545.145855 at column =  5, at id = 424 
# difference =    2.4702278 
# minABR      = 9.999900 at column =  2, at id = 421 
# maxABR      = 9.999900 at column =  2, at id = 421 
# difference =    0.0000000 
  380.788     0.000007     0.000003     0.000006     0.000004     0.000004    -0.000000     0.000003     0.000004 
  383.789     0.000003     0.000004     0.000003    -0.000001     0.000005     0.000000     0.000005     0.000002 
  386.789     0.000004     0.000005     0.000003     0.000002     0.000004     0.000003     0.000004     0.000005 
  389.790     0.000006     0.000004     0.000006     0.000002     0.000006     0.000020     0.000004     0.000006 
  392.790     0.000051     0.000035     0.000044     0.000048     0.000062     0.000061     0.000060     0.000054 
  395.790     0.000102     0.000088     0.000088     0.000078     0.000156     0.000166     0.000153     0.000169 
  398.789     0.000335     0.000340     0.000337     0.000317     0.000851     0.000840     0.000836     0.000851 
  401.788     0.001840     0.001937     0.001855     0.001768     0.004252     0.004144     0.004078     0.004159 
  404.787     0.008779     0.009321     0.008912     0.008473     0.024194     0.022724     0.022521     0.023481 
  407.785     0.062948     0.067727     0.064120     0.060645     0.182053     0.173478     0.172174     0.176192 
  410.783     0.355760     0.371834     0.359504     0.347431     0.606437     0.594499     0.592662     0.597691 
  413.781     0.748604     0.756141     0.749954     0.744218     0.811174     0.808872     0.809127     0.809131 
  416.834     0.828519     0.830609     0.829113     0.829601     0.821246     0.821091     0.821006     0.819880 
  419.831     0.824912     0.826563     0.825581     0.825476     0.820060     0.819867     0.819316     0.818775 
  422.828     0.823503     0.824756     0.824149     0.824041     0.818822     0.818916     0.818496     0.817785 
  425.824     0.827779     0.828456     0.827620     0.828438     0.819941     0.820114     0.819706     0.818996 
  428.820     0.827734     0.828811     0.827647     0.828220     0.827491     0.827053     0.827133     0.826339 
  431.815     0.835716     0.836169     0.836323     0.836385     0.833942     0.833838     0.833626     0.832825 
  434.810     0.836628     0.837333     0.836669     0.836850     0.827353     0.828454     0.828457     0.826915 
  437.862     0.829082     0.830244     0.829810     0.829496     0.829765     0.828936     0.830311     0.827507 
  440.856     0.848677     0.850380     0.849123     0.848717     0.852759     0.851916     0.853334     0.851577 
  443.850     0.855355     0.856317     0.856084     0.855929     0.848930     0.849183     0.851218     0.848030 
  446.844     0.852525     0.853147     0.852935     0.853433     0.839691     0.839656     0.841414     0.838301 
  449.837     0.842093     0.842757     0.842626     0.843016     0.852119     0.852874     0.853860     0.851179 
  452.830     0.855663     0.856262     0.855273     0.855412     0.850579     0.851727     0.853216     0.849296 
  455.878     0.855274     0.854637     0.855543     0.855761     0.848415     0.848802     0.849957     0.846840 
  458.870     0.853128     0.853991     0.853462     0.852985     0.860974     0.861364     0.862427     0.859645 
  461.862     0.869330     0.871029     0.870167     0.869465     0.868385     0.869681     0.870191     0.867341 
  464.853     0.878014     0.879134     0.878403     0.878349     0.875142     0.875502     0.876718     0.873866 
  467.901     0.878702     0.879248     0.878790     0.878519     0.872805     0.873620     0.874762     0.871473 
  470.891     0.880275     0.881226     0.880153     0.879632     0.878834     0.879232     0.880602     0.877301 
  473.881     0.890382     0.891095     0.890681     0.889662     0.890061     0.890108     0.890992     0.889859 
  476.871     0.899782     0.900206     0.899595     0.899074     0.891798     0.892916     0.894038     0.891531 
  479.916     0.893406     0.893528     0.893342     0.892850     0.882899     0.884529     0.885174     0.882813 
  482.905     0.897015     0.898708     0.896574     0.895996     0.901091     0.900724     0.901873     0.900802 
  485.894     0.908571     0.908774     0.907626     0.908302     0.900519     0.901517     0.901773     0.900371 
  488.882     0.905285     0.906532     0.904711     0.905538     0.901609     0.901926     0.902261     0.901687 
  491.925     0.904788     0.908190     0.905962     0.906869     0.904106     0.904730     0.905379     0.904452 
  494.913     0.911408     0.914335     0.911952     0.912690     0.910650     0.910746     0.911113     0.910244 
  497.899     0.914293     0.915473     0.914625     0.915188     0.912066     0.911218     0.912362     0.910873 
  500.942     0.911773     0.913364     0.912039     0.912356     0.910644     0.910374     0.911533     0.910046 
  503.928     0.912292     0.913099     0.911738     0.912135     0.901307     0.902398     0.903898     0.901146 
  506.913     0.901946     0.902003     0.901515     0.901976     0.894840     0.895226     0.896447     0.894071 
  509.954     0.899509     0.900510     0.901208     0.899555     0.908323     0.909305     0.910072     0.909101 
  512.939     0.903321     0.905211     0.904896     0.903886     0.896102     0.898218     0.899424     0.896969 
  515.923     0.883149     0.883879     0.884658     0.883544     0.870203     0.873077     0.873431     0.870360 
  518.963     0.871636     0.873882     0.873294     0.871599     0.877091     0.878092     0.879303     0.876056 
  521.946     0.888897     0.890473     0.889807     0.888890     0.890831     0.891582     0.892794     0.889520 
  524.929     0.901219     0.902047     0.902093     0.901083     0.897148     0.897382     0.899017     0.896012 
  527.967     0.901681     0.902100     0.902349     0.901671     0.900522     0.900705     0.902140     0.898743 
  530.949     0.908165     0.909076     0.908682     0.908037     0.911829     0.910982     0.913326     0.910531 
  533.987     0.919748     0.920110     0.919875     0.920352     0.917104     0.915781     0.917686     0.915773 
  536.968     0.923212     0.923922     0.924003     0.923913     0.920901     0.919999     0.922279     0.921028 
  539.948     0.922193     0.921274     0.922496     0.923307     0.831775     0.845560     0.847484     0.832137 
  542.984     0.768753     0.759931     0.769494     0.777995     0.420071     0.448123     0.448402     0.418500 
  545.964     0.331523     0.318556     0.330448     0.342353     0.103313     0.114517     0.114610     0.103138 
  548.999     0.073305     0.069128     0.072375     0.075853     0.021242     0.023889     0.023790     0.021213 
  551.977     0.015650     0.014634     0.015421     0.016199     0.004080     0.004593     0.004592     0.004093 
  555.012     0.003020     0.002882     0.002998     0.003114     0.001192     0.001311     0.001307     0.001184 
  557.989     0.001003     0.000985     0.001014     0.001031     0.000436     0.000480     0.000483     0.000434 
  561.023     0.000365     0.000354     0.000368     0.000375     0.000173     0.000188     0.000185     0.000169 
  563.999     0.000153     0.000147     0.000154     0.000155     0.000068     0.000078     0.000076     0.000069 
  567.032     0.000054     0.000060     0.000054     0.000066     0.000034     0.000032     0.000031     0.000029 
  570.007     0.000027     0.000031     0.000028     0.000028     0.000016     0.000023     0.000021     0.000018 
  573.038     0.000017     0.000018     0.000017     0.000017     0.000002     0.000004     0.000006     0.000003 
  576.013     0.000005     0.000001     0.000002     0.000002     0.000003     0.000004     0.000002     0.000002 
  579.043     0.000000     0.000003     0.000003     0.000003     0.000002    -0.000000     0.000003     0.000003 
  582.017     0.000002     0.000002     0.000002     0.000003     0.000001     0.000003     0.000002     0.000002 
  585.046     0.000001     0.000002     0.000001     0.000002     0.000001     0.000001     0.000001     0.000002 
  588.019     0.000001     0.000002     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001 
  591.047     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001 
  594.019     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001 
  597.046     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000 
  600.073     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001 
  603.043     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000 
  606.068     0.000001     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000 
  609.038     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000001 
  612.062     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000 