# number of points on sci filter + aux + bad z = 13
# number of points on sci filter               = 13
# number of positions in lambda                = 371
# noof scans  1            1            1            1            1            1            1            1            1            1            1            1            1          
# x_pos       0.000000    17.670000   -17.670000   -17.670000    17.670000    35.340000   -35.340000   -35.340000    35.340000    53.010000   -53.010000   -53.010000    53.010000 
# y_pos       0.000000    17.670000    17.670000   -17.670000   -17.670000    35.340000    35.340000   -35.340000   -35.340000    53.010000    53.010000   -53.010000   -53.010000 
# angle       1.780000     2.230000     1.840000     1.320000     1.840000     2.690000     2.000000     0.870000     2.000000     3.140000     2.230000     0.410000     2.230000 
# z_pos      44.000000    47.000000    45.000000    43.000000    45.000000    48.000000    46.000000    42.000000    46.000000    49.000000    47.000000    41.000000    47.000000 
# r_pos       0.000000    24.990000    24.990000    24.990000    24.990000    49.980000    49.980000    49.980000    49.980000    74.970000    74.970000    74.970000    74.970000 
# phi         0.000000     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602 
# gnupl col      2            3            4            5            6            7            8            9           10           11           12           13           14      
# pos_id       102          103          104          105          106          107          108          109          110          111          112          113          114      
#
# lambda for peak transmission
#          675.6700000  675.6700000  675.6700000  675.6700000  675.6700000  675.6700000  675.1680000  676.1720000  676.1720000  675.1680000  675.1680000  676.1720000  676.1720000 
# peak transmission
#            0.8142160    0.8274390    0.8078580    0.8231510    0.8155950    0.8463650    0.8099190    0.8387430    0.8142720    0.8356550    0.8270700    0.8502120    0.8250190 
# lambda blue with 1/2 of peak transmission
#          673.1234742  672.9561112  672.9460398  673.3893414  673.3803750  672.8462430  672.7845791  673.6183929  673.7273905  672.4560054  672.3188316  673.7768911  674.0879598 
# lambda red  with 1/2 of peak transmission
#          684.7381461  684.4610444  684.5589000  684.9945629  684.9328109  684.1611069  684.4344713  685.2615472  685.2469246  683.5933029  683.8808264  685.5687036  685.6512588 
# half width                              
#           11.6146719   11.5049333   11.6128601   11.6052215   11.5524359   11.3148638   11.6498922   11.6431543   11.5195341   11.1372974   11.5619948   11.7918124   11.5632990 
# central wavelength                      
#          678.9308102  678.7085778  678.7524699  679.1919521  679.1565930  678.5036749  678.6095252  679.4399701  679.4871575  678.0246541  678.0998290  679.6727973  679.8696093 
# central wavelength calculated as SAGEM (mean frequency)
#          678.8811362  678.6598222  678.7027984  679.1423781  679.1074663  678.4565027  678.5595259  679.3900896  679.4383341  677.9789186  678.0505443  679.6216526  679.8204419 
# lambda blue with 80% of peak transmission
#          674.0853593  673.9503906  673.9444482  674.3527112  674.3438962  673.8715063  673.7705777  674.5519830  674.6371271  673.5312577  673.3250163  674.7141663  675.0169619 
# lambda red  with 80% of peak transmission
#          683.6136148  683.2315518  683.4779382  683.8600501  683.7820420  682.5436482  683.3211813  684.0124426  684.0346961  679.3712199  682.6997463  684.2290159  684.2644614 
# lambda blue with 0.0001 of peak transmission
#          658.9240380  657.7222550  657.3362690  658.1791818  659.0447473  657.1933020  658.9400771  658.9443722  659.7891030  659.2156111  658.2847819  658.2905959  658.8775505 
# lambda red  with 0.0001 of peak transmission
#          704.3966005  696.1454917  704.2296949  697.1748551  704.4320833  703.0432637  704.0487292  698.1695500  704.5319245  698.6385874  703.5128560  704.6559949  704.6853661 
# ATB calculated from points above 80%
#            0.7745568    0.7635462    0.7714158    0.7965513    0.7727112    0.7653978    0.7636159    0.8054886    0.7653078    0.7625767    0.7563896    0.8084196    0.7607807 
# ATB calculated from points above 50%
#            0.7201147    0.7235104    0.7309922    0.7531757    0.7315001    0.7124810    0.7259135    0.7476536    0.7244180    0.6878622    0.7195829    0.7688093    0.7203171 
# ABR calculated from points below and above 0.0001
#            0.0008244    0.0013430    0.0007812    0.0008824    0.0021100    0.0015721    0.0007153    0.0013915   -0.0002041    0.0006666    0.0020787    0.0021784   -0.0000969 
# minCWL      = 678.024654 at column = 11, at id = 111 
# maxCWL      = 679.869609 at column = 14, at id = 114 
# difference =    1.8449552 
# minBW       = 11.137297 at column = 11, at id = 111 
# maxBW       = 11.791812 at column = 13, at id = 113 
# difference =    0.6545150 
# minATB80    = 0.756390 at column = 12, at id = 112 
# maxATB80    = 0.808420 at column = 13, at id = 113 
# difference =    0.0520300 
# minBlueEdge = 672.318832 at column = 12, at id = 112 
# maxBlueEdge = 674.087960 at column = 14, at id = 114 
# difference =    1.7691283 
# minRedEdge  = 683.593303 at column = 11, at id = 111 
# maxRedEdge  = 685.651259 at column = 14, at id = 114 
# difference =    2.0579560 
# minABR      = -0.000204 at column = 10, at id = 110 
# maxABR      = 0.002178 at column = 13, at id = 113 
# difference =    0.0023825 
  299.645    -0.000185    -0.000041    -0.000466    -0.000748    -0.000295     0.000348     0.000042    -0.000077    -0.000663     0.000670     0.000199     0.000687     0.000078 
  302.654    -0.000143    -0.000105    -0.000067     0.000110    -0.000208    -0.000025    -0.000302    -0.000021    -0.000278    -0.000038     0.000183     0.000062    -0.000200 
  305.662    -0.000043     0.000043    -0.000003     0.000041    -0.000026     0.000035    -0.000125     0.000038    -0.000079    -0.000020     0.000062     0.000033    -0.000170 
  308.671    -0.000019    -0.000004    -0.000036     0.000017     0.000028    -0.000090     0.000004    -0.000008    -0.000021    -0.000038     0.000044    -0.000012    -0.000085 
  311.679    -0.000015    -0.000012     0.000034     0.000059    -0.000041    -0.000061     0.000040     0.000021    -0.000016     0.000017     0.000025     0.000018    -0.000039 
  314.687    -0.000005    -0.000010    -0.000037     0.000011    -0.000019    -0.000027    -0.000026    -0.000012     0.000002    -0.000001     0.000042     0.000014    -0.000010 
  317.694     0.000002     0.000010    -0.000025     0.000003     0.000009     0.000007    -0.000045     0.000020     0.000007    -0.000013     0.000016     0.000006    -0.000038 
  320.702    -0.000037    -0.000016     0.000004     0.000002     0.000002     0.000020    -0.000008    -0.000003    -0.000014    -0.000006    -0.000011     0.000010    -0.000007 
  323.709    -0.000023    -0.000014    -0.000013    -0.000006    -0.000002     0.000001    -0.000011     0.000005    -0.000024    -0.000001     0.000016     0.000008    -0.000014 
  326.716     0.000018     0.000006     0.000017     0.000002    -0.000002     0.000008    -0.000016    -0.000006    -0.000028     0.000006     0.000028    -0.000000    -0.000012 
  329.665     0.000001     0.000008    -0.000004    -0.000011    -0.000017    -0.000005     0.000001     0.000004    -0.000009    -0.000013     0.000030    -0.000009    -0.000016 
  332.672    -0.000012    -0.000001    -0.000000     0.000001    -0.000012    -0.000007     0.000001     0.000001    -0.000016    -0.000003     0.000026    -0.000011    -0.000001 
  335.678    -0.000022     0.000004    -0.000003    -0.000010     0.000013    -0.000011    -0.000013    -0.000009    -0.000009     0.000009     0.000002    -0.000009     0.000006 
  338.683     0.000001     0.000005     0.000014    -0.000007     0.000005     0.000004    -0.000011     0.000009    -0.000008     0.000010     0.000008    -0.000002    -0.000009 
  341.689    -0.000005     0.000010     0.000001     0.000004     0.000010     0.000004     0.000002     0.000004    -0.000003     0.000009     0.000005    -0.000004    -0.000013 
  344.694    -0.000006     0.000004    -0.000003     0.000002     0.000007     0.000008     0.000002    -0.000003    -0.000003     0.000011     0.000011    -0.000008    -0.000002 
  347.699    -0.000005     0.000002    -0.000002    -0.000002     0.000006    -0.000003     0.000003     0.000000    -0.000001     0.000010     0.000005    -0.000001    -0.000012 
  350.703     0.000002    -0.000000     0.000005     0.000001     0.000005     0.000001    -0.000003    -0.000003     0.000000     0.000005     0.000006    -0.000003    -0.000000 
  353.707     0.000000     0.000004    -0.000001     0.000003     0.000000     0.000003    -0.000005    -0.000001    -0.000005     0.000010     0.000010    -0.000005    -0.000000 
  356.711    -0.000002    -0.000003     0.000005    -0.000001    -0.000004     0.000000     0.000001    -0.000008    -0.000012     0.000008     0.000002     0.000003     0.000003 
  359.715    -0.000002    -0.000006     0.000002    -0.000001     0.000001    -0.000001    -0.000002    -0.000004    -0.000003     0.000010     0.000004    -0.000008    -0.000001 
  362.718     0.000001    -0.000002     0.000005     0.000003    -0.000001    -0.000001    -0.000003     0.000000    -0.000001     0.000003     0.000006    -0.000006    -0.000010 
  365.721    -0.000002     0.000000     0.000002    -0.000001     0.000001    -0.000003     0.000003     0.000000    -0.000007     0.000006     0.000005    -0.000002    -0.000002 
  368.724    -0.000003    -0.000003     0.000001    -0.000001    -0.000000    -0.000003     0.000004    -0.000006     0.000002     0.000002     0.000003    -0.000007     0.000002 
  371.726    -0.000002     0.000002     0.000002     0.000004    -0.000004     0.000002     0.000002    -0.000001     0.000000     0.000002    -0.000002    -0.000007    -0.000000 
  374.728    -0.000001     0.000001    -0.000001     0.000004    -0.000000    -0.000001     0.000001    -0.000006     0.000000     0.000000     0.000004    -0.000002    -0.000002 
  377.730    -0.000001     0.000000    -0.000000    -0.000001     0.000002    -0.000001     0.000000    -0.000001    -0.000002     0.000002     0.000004    -0.000000    -0.000002 
  380.788    -0.000002     0.000003     0.000001     0.000001     0.000001     0.000001     0.000002     0.000000    -0.000001     0.000002     0.000004    -0.000001    -0.000004 
  383.789    -0.000002     0.000003     0.000002    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000002     0.000003    -0.000000     0.000001    -0.000002 
  386.789    -0.000003     0.000002     0.000002    -0.000001     0.000001    -0.000002     0.000001     0.000002    -0.000002     0.000002     0.000000     0.000001    -0.000001 
  389.790    -0.000001    -0.000001     0.000002    -0.000000     0.000001     0.000000    -0.000000     0.000002    -0.000003     0.000001     0.000003    -0.000001    -0.000001 
  392.790     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000    -0.000001     0.000002    -0.000003    -0.000002     0.000001    -0.000000     0.000001 
  395.790    -0.000000    -0.000000    -0.000001     0.000000    -0.000000     0.000001     0.000001     0.000001    -0.000001     0.000002     0.000002    -0.000002     0.000001 
  398.789     0.000000     0.000001     0.000001     0.000001     0.000001    -0.000001     0.000002     0.000002    -0.000002     0.000002     0.000001    -0.000002    -0.000000 
  401.788    -0.000000    -0.000000     0.000001     0.000002     0.000003    -0.000001     0.000000     0.000003    -0.000002    -0.000000     0.000001    -0.000001    -0.000001 
  404.787    -0.000001    -0.000001    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000002    -0.000002     0.000002     0.000002    -0.000002    -0.000001 
  407.785    -0.000001    -0.000000    -0.000001     0.000002     0.000000    -0.000001     0.000001     0.000002    -0.000000     0.000001     0.000001    -0.000000    -0.000001 
  410.783    -0.000001    -0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000001     0.000002    -0.000000     0.000003     0.000001     0.000000    -0.000001 
  413.781     0.000000     0.000001     0.000001     0.000001     0.000001    -0.000001     0.000001     0.000002    -0.000000     0.000002     0.000002     0.000002     0.000001 
  416.834     0.000000     0.000000     0.000001    -0.000001    -0.000001     0.000000    -0.000000     0.000001    -0.000000     0.000002     0.000002     0.000001     0.000000 
  419.831     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000001     0.000000     0.000000     0.000001     0.000001 
  422.828     0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000001    -0.000001     0.000000     0.000001    -0.000000    -0.000000 
  425.824    -0.000000     0.000001     0.000002    -0.000000     0.000001    -0.000001    -0.000001    -0.000000    -0.000001    -0.000000     0.000001    -0.000000     0.000001 
  428.820    -0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000000 
  431.815     0.000000     0.000000    -0.000000    -0.000001     0.000000    -0.000000     0.000001     0.000000    -0.000001     0.000000    -0.000000     0.000000    -0.000000 
  434.810     0.000000     0.000000     0.000000     0.000000     0.000002     0.000000     0.000001     0.000001    -0.000001     0.000001     0.000001     0.000002     0.000001 
  437.862     0.000001    -0.000001    -0.000000    -0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000 
  440.856     0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000002    -0.000000     0.000000     0.000001     0.000001     0.000002     0.000001     0.000000 
  443.850     0.000001     0.000001     0.000000    -0.000000     0.000001     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000000 
  446.844     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  449.837     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000 
  452.830    -0.000001     0.000001     0.000001    -0.000000    -0.000000     0.000000    -0.000001     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001 
  455.878    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000 
  458.870     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000001     0.000000    -0.000000     0.000001     0.000001     0.000000 
  461.862     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000 
  464.853    -0.000000    -0.000001    -0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
  467.901     0.000000     0.000001     0.000001    -0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001 
  470.891     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001 
  473.881     0.000001     0.000001     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000 
  476.871     0.000001     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000001     0.000000     0.000001    -0.000000     0.000000 
  479.916    -0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001 
  482.905     0.000000     0.000001     0.000000    -0.000001     0.000000    -0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000    -0.000000 
  485.894     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000 
  488.882     0.000000     0.000001     0.000000    -0.000000    -0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000 
  491.925    -0.000000     0.000001     0.000001    -0.000001    -0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001    -0.000000    -0.000000 
  494.913    -0.000000    -0.000000    -0.000000    -0.000000    -0.000001    -0.000000     0.000000     0.000000    -0.000001    -0.000001     0.000001     0.000000    -0.000000 
  497.899     0.000000    -0.000000     0.000001    -0.000001    -0.000001     0.000001     0.000000     0.000001    -0.000001     0.000000     0.000002     0.000000    -0.000000 
  500.942     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000001    -0.000001 
  503.928     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000001    -0.000001 
  506.913     0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000 
  509.954    -0.000001     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000 
  512.939    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000002     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000 
  515.923     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000    -0.000001    -0.000000     0.000001    -0.000000     0.000000 
  518.963     0.000000    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000001 
  521.946    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000 
  524.929     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001 
  527.967     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000001     0.000000    -0.000000 
  530.949     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000001 
  533.987    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000 
  536.968     0.000000    -0.000000     0.000001    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001 
  539.948     0.000000     0.000000     0.000001     0.000000    -0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000 
  542.984    -0.000000     0.000000     0.000000     0.000000    -0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000 
  545.964     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000 
  548.999     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000 
  551.977    -0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000000 
  555.012    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000 
  557.989     0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000001     0.000001     0.000001     0.000001     0.000000    -0.000000 
  561.023     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000001    -0.000000     0.000001 
  563.999     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001 
  567.032     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  570.007     0.000001     0.000001    -0.000000     0.000000     0.000000    -0.000001    -0.000001     0.000001    -0.000001     0.000000     0.000001     0.000000     0.000001 
  573.038     0.000000     0.000000    -0.000000     0.000000    -0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000 
  576.013     0.000001     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000 
  579.043     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  582.017     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000 
  585.046    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000000 
  588.019    -0.000000     0.000000     0.000005     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001 
  591.047     0.000005     0.000006     0.000002     0.000001     0.000001     0.000007     0.000005     0.000009     0.000001     0.000002     0.000001     0.000001     0.000002 
  594.019     0.000014     0.000014     0.000011     0.000015     0.000013     0.000012     0.000012     0.000017     0.000017     0.000013     0.000014     0.000019     0.000014 
  597.046     0.000006     0.000002     0.000002     0.000005     0.000006     0.000002     0.000002     0.000012     0.000004     0.000001     0.000001     0.000016     0.000008 
  600.073     0.000001     0.000002     0.000002     0.000001     0.000001     0.000002     0.000002     0.000001     0.000001     0.000002     0.000002     0.000006     0.000002 
  603.043     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000000     0.000001     0.000001     0.000001     0.000001 
  606.068     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000000 
  609.038     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000 
  612.062     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001    -0.000000 
  615.086     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000002     0.000001    -0.000000 
  618.053     0.000001     0.000002     0.000002     0.000001     0.000001     0.000002     0.000013     0.000006     0.000001     0.000002     0.000014     0.000001     0.000001 
  621.076     0.000014     0.000014     0.000013     0.000011     0.000011     0.000017     0.000012     0.000014     0.000013     0.000015     0.000017     0.000013     0.000014 
  624.099     0.000017     0.000014     0.000015     0.000015     0.000014     0.000013     0.000015     0.000013     0.000012     0.000012     0.000016     0.000017     0.000015 
  627.064     0.000015     0.000013     0.000012     0.000014     0.000013     0.000012     0.000011     0.000013     0.000012     0.000011     0.000012     0.000016     0.000014 
  630.086     0.000013     0.000012     0.000011     0.000013     0.000011     0.000013     0.000015     0.000012     0.000011     0.000010     0.000012     0.000014     0.000010 
  633.106     0.000015     0.000013     0.000014     0.000013     0.000011     0.000007     0.000014     0.000013     0.000012     0.000012     0.000014     0.000014     0.000013 
  636.071     0.000016     0.000013     0.000013     0.000015     0.000012     0.000014     0.000007     0.000016     0.000012     0.000012     0.000015     0.000015     0.000014 
  639.090     0.000019     0.000013     0.000014     0.000016     0.000013     0.000016     0.000015     0.000016     0.000016     0.000015     0.000015     0.000017     0.000014 
  642.109     0.000018     0.000019     0.000020     0.000017     0.000019     0.000015     0.000016     0.000017     0.000018     0.000019     0.000020     0.000019     0.000018 
  645.128     0.000029     0.000025     0.000024     0.000027     0.000025     0.000020     0.000023     0.000024     0.000026     0.000024     0.000028     0.000021     0.000022 
  648.090     0.000040     0.000034     0.000038     0.000039     0.000033     0.000032     0.000036     0.000036     0.000032     0.000042     0.000040     0.000034     0.000033 
  651.107     0.000063     0.000059     0.000062     0.000062     0.000056     0.000060     0.000063     0.000060     0.000053     0.000065     0.000071     0.000063     0.000052 
  654.123     0.000108     0.000105     0.000106     0.000102     0.000098     0.000108     0.000113     0.000104     0.000089     0.000117     0.000126     0.000106     0.000088 
  657.139     0.000060     0.000040     0.000060     0.000015    -0.000005     0.000076     0.000017     0.000038     0.000030     0.000006     0.000044     0.000063     0.000046 
  657.642     0.000071     0.000077     0.000113     0.000115     0.000119     0.000156     0.000076     0.000030     0.000059     0.000136     0.000128     0.000055     0.000046 
  658.145     0.000065     0.000113     0.000081     0.000080     0.000028     0.000113     0.000101     0.000087     0.000028     0.000133     0.000066     0.000074     0.000103 
  658.647     0.000066     0.000115     0.000116     0.000114     0.000061     0.000114     0.000074     0.000062     0.000046     0.000118     0.000126     0.000112     0.000033 
  659.150     0.000094     0.000100     0.000134     0.000107     0.000087     0.000151     0.000086     0.000099     0.000029     0.000076     0.000180     0.000121     0.000141 
  659.653     0.000144     0.000105     0.000121     0.000154     0.000132     0.000203     0.000082     0.000658     0.000068     0.000134     0.000230     0.000148     0.000173 
  660.099     0.000147     0.000095     0.000138     0.000160     0.000108     0.000173     0.000129     0.000109     0.000112     0.000172     0.000221     0.000102     0.000150 
  660.602     0.000199     0.000182     0.000170     0.000175     0.000093     0.000242     0.000145     0.000144     0.000092     0.000175     0.000217     0.000162     0.000098 
  661.104     0.000225     0.000239     0.000211     0.000199     0.000158     0.000267     0.000227     0.000202     0.000134     0.000225     0.000258     0.000221     0.000148 
  661.607     0.000209     0.000232     0.000699     0.000240     0.000174     0.000315     0.000263     0.000188     0.000583     0.000300     0.000325     0.000281     0.000098 
  662.109     0.000261     0.000316     0.000603     0.000290     0.000692     0.000334     0.000379     0.000282     0.000128     0.001187     0.000838     0.000736     0.000174 
  662.612     0.000307     0.000304     0.001085     0.000318     0.000921     0.001265     0.000854     0.000374     0.000140     0.001271     0.001355     0.001019     0.000142 
  663.114     0.001221     0.000938     0.001419     0.001228     0.000928     0.001330     0.001124     0.001262     0.001118     0.001647     0.001683     0.001246     0.000275 
  663.617     0.001348     0.001609     0.001515     0.001399     0.001333     0.001732     0.001663     0.001529     0.001217     0.002065     0.002128     0.001288     0.000359 
  664.119     0.001580     0.001842     0.001936     0.001733     0.001638     0.002093     0.001835     0.001772     0.001436     0.002564     0.002718     0.001614     0.001420 
  664.621     0.001928     0.002122     0.002518     0.001973     0.001892     0.002517     0.002196     0.002066     0.001579     0.003097     0.003179     0.001894     0.001459 
  665.124     0.002636     0.002652     0.002805     0.002421     0.002442     0.003130     0.002857     0.002412     0.002143     0.003925     0.004105     0.002322     0.001766 
  665.626     0.003207     0.003570     0.003603     0.003014     0.003042     0.004126     0.003520     0.003161     0.002592     0.004966     0.005375     0.002886     0.002223 
  666.129     0.004170     0.004537     0.004642     0.003979     0.003659     0.004975     0.004682     0.003681     0.003304     0.006283     0.006837     0.003608     0.002831 
  666.631     0.005271     0.005897     0.005950     0.004859     0.004840     0.006390     0.005849     0.004475     0.004268     0.008254     0.009053     0.004646     0.003496 
  667.133     0.006845     0.007769     0.007538     0.006404     0.006036     0.008561     0.008430     0.006114     0.005130     0.011165     0.011781     0.005736     0.004406 
  667.635     0.008859     0.009814     0.009854     0.008047     0.007659     0.011304     0.011003     0.007650     0.006691     0.014594     0.015254     0.007298     0.005673 
  668.138     0.011851     0.013030     0.013277     0.010578     0.010458     0.015043     0.014770     0.010054     0.008871     0.019780     0.020995     0.009456     0.007142 
  668.640     0.015903     0.017709     0.017613     0.013904     0.013759     0.019884     0.019917     0.013197     0.011481     0.027175     0.029042     0.012565     0.009596 
  669.142     0.022480     0.024973     0.024974     0.019623     0.019339     0.028766     0.027548     0.017837     0.015869     0.039614     0.041725     0.016843     0.012682 
  669.645     0.031087     0.035098     0.034935     0.026747     0.026322     0.040143     0.039029     0.024165     0.021384     0.056397     0.059365     0.022599     0.017027 
  670.147     0.043499     0.050071     0.049278     0.037296     0.036857     0.057066     0.056268     0.033193     0.029410     0.080090     0.085513     0.031124     0.023404 
  670.649     0.062613     0.072679     0.071196     0.052859     0.052502     0.083060     0.081473     0.046642     0.041274     0.117882     0.125108     0.043307     0.032591 
  671.151     0.092246     0.106822     0.105212     0.077064     0.075867     0.122617     0.120061     0.066787     0.059471     0.171955     0.183228     0.061717     0.045752 
  671.653     0.134679     0.156848     0.154661     0.112304     0.111589     0.179602     0.176988     0.097424     0.086602     0.245970     0.263587     0.089245     0.065580 
  672.155     0.200331     0.231403     0.227164     0.166196     0.165549     0.262000     0.259941     0.143780     0.128291     0.345737     0.371642     0.130559     0.097109 
  672.658     0.294135     0.335612     0.329718     0.245687     0.244219     0.372601     0.371059     0.213096     0.190682     0.466205     0.500263     0.192328     0.144231 
  673.160     0.415973     0.467140     0.459054     0.355756     0.355314     0.507490     0.505505     0.313459     0.283025     0.594092     0.630296     0.283650     0.215925 
  673.662     0.542572     0.591550     0.579156     0.477938     0.474868     0.628719     0.625109     0.429447     0.389262     0.694736     0.725697     0.393134     0.306101 
  674.164     0.671583     0.714097     0.698468     0.615998     0.611603     0.744626     0.730644     0.569863     0.526480     0.776518     0.792988     0.532831     0.431505 
  674.666     0.759727     0.792764     0.771892     0.729115     0.725659     0.817709     0.790600     0.700714     0.659042     0.821269     0.821245     0.669912     0.570694 
  675.168     0.808017     0.825595     0.805450     0.796424     0.792124     0.846238     0.809919     0.789446     0.756215     0.835655     0.827070     0.776819     0.698455 
  675.670     0.814216     0.827439     0.807858     0.823151     0.815595     0.846365     0.806332     0.834296     0.809753     0.828292     0.814295     0.834737     0.792190 
  676.172     0.804493     0.811341     0.794938     0.820782     0.808892     0.831178     0.792968     0.838743     0.814272     0.809686     0.798664     0.850212     0.825019 
  676.674     0.790656     0.794634     0.781645     0.810202     0.792710     0.811065     0.780477     0.832597     0.802139     0.787823     0.784154     0.846048     0.821121 
  677.120     0.778539     0.781542     0.775344     0.801643     0.782271     0.796723     0.772110     0.824688     0.788853     0.766522     0.771344     0.837990     0.806623 
  677.622     0.773621     0.770712     0.768748     0.796871     0.772929     0.778856     0.765621     0.819313     0.773726     0.742294     0.757998     0.830056     0.788074 
  678.124     0.770757     0.763918     0.767622     0.796999     0.768528     0.764686     0.760340     0.815720     0.767411     0.718143     0.746811     0.824437     0.774578 
  678.626     0.770649     0.757663     0.767502     0.800962     0.769252     0.750094     0.755171     0.818461     0.765028     0.695334     0.736026     0.822609     0.764974 
  679.128     0.774554     0.753613     0.767937     0.806330     0.770693     0.738578     0.754871     0.821220     0.762941     0.675089     0.729012     0.822919     0.760156 
  679.630     0.778161     0.751423     0.773434     0.811591     0.775759     0.727575     0.753801     0.824542     0.767256     0.661539     0.726709     0.824385     0.758619 
  680.132     0.779557     0.750738     0.776965     0.815630     0.779978     0.720232     0.755383     0.825883     0.769028     0.651674     0.728942     0.824358     0.757393 
  680.634     0.784985     0.751437     0.779965     0.818397     0.782234     0.716288     0.760146     0.823991     0.769918     0.646786     0.734689     0.820126     0.756389 
  681.136     0.788062     0.754485     0.786380     0.819448     0.784353     0.714150     0.767709     0.820763     0.772104     0.644062     0.742324     0.816234     0.754922 
  681.638     0.790359     0.755557     0.788747     0.818008     0.788645     0.711130     0.770167     0.816596     0.774356     0.637082     0.741915     0.810463     0.755449 
  682.139     0.786394     0.748764     0.781834     0.812364     0.785133     0.699633     0.764029     0.809117     0.773022     0.615198     0.721222     0.805686     0.755209 
  682.641     0.766763     0.727060     0.758444     0.797210     0.771868     0.671669     0.738137     0.796701     0.766064     0.572599     0.671896     0.795308     0.750739 
  683.143     0.725954     0.676573     0.704186     0.762049     0.739364     0.616195     0.681226     0.770282     0.747073     0.501443     0.584393     0.778376     0.742548 
  683.645     0.646399     0.593682     0.617407     0.697899     0.676617     0.530312     0.587434     0.723359     0.705289     0.408228     0.468668     0.748953     0.720420 
  684.146     0.538972     0.485062     0.504443     0.606160     0.588362     0.426355     0.473037     0.651961     0.636031     0.310585     0.351541     0.693321     0.676891 
  684.648     0.428079     0.371383     0.382239     0.493102     0.472550     0.320933     0.354568     0.553598     0.536326     0.223623     0.249335     0.613794     0.605377 
  685.150     0.311297     0.269538     0.277870     0.375010     0.358419     0.229560     0.252720     0.440911     0.426396     0.154859     0.171783     0.510680     0.509559 
  685.652     0.228264     0.194176     0.200959     0.283005     0.270153     0.165304     0.180686     0.343976     0.326643     0.109891     0.121967     0.408082     0.412366 
  686.153     0.161612     0.133960     0.136515     0.199380     0.185191     0.113439     0.123792     0.248626     0.231135     0.074883     0.083149     0.305620     0.307479 
  686.655     0.110913     0.094845     0.099003     0.142286     0.134123     0.080715     0.087809     0.181263     0.169310     0.053382     0.059351     0.225450     0.226711 
  687.157     0.079180     0.065472     0.068091     0.099773     0.093431     0.056245     0.061220     0.127640     0.116237     0.037643     0.042160     0.158907     0.159614 
  687.658     0.057723     0.048028     0.049127     0.071845     0.065066     0.040913     0.043652     0.092415     0.082538     0.027724     0.030687     0.115926     0.114213 
  688.160     0.039430     0.034056     0.035487     0.050073     0.046655     0.029253     0.030946     0.064727     0.058811     0.019712     0.022265     0.080907     0.079194 
  688.662     0.029379     0.024316     0.025571     0.036448     0.033741     0.021128     0.022584     0.046338     0.041050     0.014713     0.016592     0.057395     0.055454 
  689.163     0.021891     0.018516     0.019327     0.027293     0.024657     0.015909     0.017465     0.034645     0.030229     0.011180     0.012749     0.042670     0.040520 
  689.665     0.015798     0.013984     0.014679     0.019995     0.018626     0.012236     0.012722     0.025411     0.022670     0.008374     0.009666     0.031181     0.029640 
  690.166     0.012801     0.010887     0.011214     0.015470     0.013987     0.009685     0.010074     0.019433     0.016698     0.006699     0.007677     0.023583     0.022023 
  690.668     0.009823     0.008375     0.008861     0.011765     0.010905     0.007324     0.007680     0.014735     0.012716     0.005261     0.005987     0.017972     0.016604 
  691.169     0.007328     0.006553     0.006839     0.009236     0.008595     0.005715     0.006188     0.011298     0.010068     0.004068     0.004931     0.013759     0.012695 
  691.671     0.005890     0.005243     0.005490     0.007341     0.006947     0.004290     0.004826     0.008921     0.007502     0.003367     0.003870     0.010677     0.009448 
  692.172     0.004514     0.003935     0.004509     0.005825     0.005502     0.003668     0.004044     0.006894     0.006023     0.002361     0.003115     0.008326     0.007365 
  692.674     0.003752     0.003064     0.003521     0.004619     0.004364     0.002987     0.002880     0.005744     0.004838     0.002182     0.002593     0.006408     0.005790 
  693.175     0.003350     0.002582     0.002812     0.003876     0.003180     0.002335     0.002786     0.004394     0.003794     0.001625     0.001985     0.005018     0.004676 
  693.677     0.002274     0.002333     0.002405     0.003120     0.002483     0.001776     0.001798     0.003520     0.003082     0.001268     0.001678     0.004291     0.003593 
  694.178     0.001796     0.001958     0.001912     0.002556     0.002327     0.001826     0.001528     0.002833     0.002465     0.000681     0.001475     0.003484     0.002936 
  694.679     0.001542     0.001294     0.001591     0.002000     0.001837     0.001232     0.001424     0.002544     0.002073     0.000349     0.001318     0.002731     0.002384 
  695.181     0.001419     0.001204     0.001243     0.001657     0.001541     0.001252     0.001155     0.002064     0.001481     0.000155     0.000601     0.002345     0.002065 
  695.682     0.001184     0.001167     0.000739     0.001525     0.001395     0.000538     0.000610     0.001617     0.001509     0.000266     0.000555     0.001889     0.001401 
  696.183     0.000103    -0.000005     0.000093     0.001365     0.000647     0.000254     0.000081     0.001299     0.000748     0.000263     0.000622     0.001525     0.000851 
  696.685     0.000275     0.000138     0.000853     0.001195     0.001144     0.000322     0.000419     0.001400     0.000135     0.000187     0.000731     0.001353     0.000716 
  697.186     0.000255     0.000183     0.000226     0.000057     0.000133     0.000285     0.000277     0.000654     0.000735     0.000135     0.000537     0.001223     0.000134 
  697.687     0.000171     0.000140     0.000278     0.000309     0.000333     0.000243     0.000274     0.000701     0.000207     0.000100     0.000310     0.000609     0.000226 
  698.189     0.000168     0.000138     0.000226     0.000283     0.000259     0.000233     0.000253     0.000059     0.000221     0.000106     0.000208     0.000105     0.000215 
  698.690     0.000166     0.000154     0.000165     0.000286     0.000200     0.000282     0.000155     0.000043     0.000248     0.000081     0.000136     0.000196     0.000218 
  699.191     0.000094     0.000141     0.000133     0.000201     0.000167     0.000151     0.000197     0.000202     0.000210     0.000048     0.000132     0.000216     0.000177 
  702.198     0.000156     0.000135     0.000147     0.000173     0.000167     0.000106     0.000137     0.000189     0.000180     0.000046     0.000119     0.000206     0.000195 
  705.205     0.000054     0.000042     0.000049     0.000052     0.000052     0.000030     0.000046     0.000055     0.000053     0.000008     0.000036     0.000058     0.000059 
  708.211     0.000015     0.000018     0.000018     0.000019     0.000015     0.000003     0.000010     0.000017     0.000015    -0.000002     0.000015     0.000018     0.000018 
  711.216     0.000000     0.000001     0.000001    -0.000001     0.000001     0.000004     0.000001     0.000001     0.000000     0.000001    -0.000001     0.000007     0.000001 
  714.220     0.000002     0.000002     0.000001     0.000002     0.000002     0.000001     0.000002     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002 
  717.224     0.000002     0.000001     0.000001     0.000002     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000002     0.000001     0.000001 
  720.228     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000001     0.000000     0.000000     0.000000     0.000001 
  723.230     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001    -0.000001     0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000001 
  726.232     0.000001     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000 
  729.234     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000000    -0.000000 
  732.234    -0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000000     0.000000    -0.000000 
  735.235     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000    -0.000001     0.000000    -0.000001    -0.000000    -0.000000     0.000001    -0.000000 
  738.234     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000 
  741.233     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000001    -0.000001     0.000000     0.000000    -0.000000    -0.000000 
  744.231     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000001    -0.000000     0.000000    -0.000000    -0.000001 
  747.228     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000001    -0.000001     0.000000    -0.000000    -0.000000    -0.000001 
  750.225    -0.000000    -0.000000     0.000000     0.000001     0.000000     0.000001    -0.000001    -0.000001    -0.000000    -0.000000     0.000000     0.000000    -0.000001 
  753.221    -0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000    -0.000001    -0.000000    -0.000001    -0.000001    -0.000000     0.000001    -0.000001 
  756.272     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000    -0.000001    -0.000000    -0.000001    -0.000000     0.000001     0.000000    -0.000001 
  759.267    -0.000000     0.000001    -0.000001     0.000001    -0.000001    -0.000000    -0.000000    -0.000001    -0.000001    -0.000000     0.000001    -0.000000    -0.000001 
  762.261     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001    -0.000001    -0.000000    -0.000001    -0.000001     0.000000     0.000000    -0.000000 
  765.254    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000001     0.000001     0.000001    -0.000000 
  768.247    -0.000000    -0.000000     0.000001     0.000001    -0.000001     0.000001     0.000000    -0.000001    -0.000001     0.000001     0.000001     0.000000    -0.000000 
  771.294     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000000    -0.000000    -0.000001    -0.000001     0.000000     0.000001     0.000000     0.000000 
  774.286     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000000     0.000001     0.000001    -0.000000 
  777.277     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000001    -0.000000    -0.000000    -0.000001     0.000001     0.000001     0.000001 
  780.266    -0.000000     0.000001     0.000001     0.000001     0.000001    -0.000000    -0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001 
  783.311     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000001    -0.000000     0.000000     0.000000     0.000001 
  786.300    -0.000000     0.000002     0.000001     0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000002     0.000001     0.000001     0.000001 
  789.288     0.000000     0.000001     0.000001     0.000000     0.000001     0.000002     0.000001     0.000002    -0.000001     0.000003     0.000001     0.000001     0.000001 
  792.275     0.000001     0.000002     0.000003     0.000001     0.000002     0.000002     0.000001     0.000001    -0.000000     0.000004     0.000002     0.000003     0.000001 
  795.316     0.000001     0.000003     0.000002     0.000003     0.000003     0.000004     0.000002     0.000003     0.000015     0.000014     0.000002     0.000003     0.000003 
  798.302     0.000001     0.000004     0.000005     0.000004     0.000003     0.000004     0.000003     0.000002     0.000001     0.000001     0.000003     0.000002     0.000005 
  801.287     0.000000     0.000001     0.000002     0.000002     0.000002     0.000001     0.000001     0.000001     0.000000     0.000002     0.000002     0.000000     0.000002 
  804.327     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000000     0.000001    -0.000001     0.000001     0.000001     0.000000     0.000000 
  807.310    -0.000000     0.000002     0.000001     0.000001     0.000001     0.000002    -0.000001     0.000001    -0.000001     0.000001     0.000000     0.000000     0.000000 
  810.348    -0.000001     0.000000     0.000001     0.000002     0.000000     0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001 
  813.331     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001    -0.000001     0.000000     0.000001    -0.000001     0.000000 
  816.312     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000    -0.000001     0.000002    -0.000002    -0.000000     0.000000    -0.000000    -0.000000 
  819.348     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000002    -0.000002     0.000001     0.000000     0.000001 
  822.328     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001    -0.000001     0.000002    -0.000002    -0.000000     0.000001    -0.000000    -0.000001 
  825.362     0.000000    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000001    -0.000001    -0.000001    -0.000000     0.000000 
  828.341    -0.000001    -0.000001    -0.000000     0.000001    -0.000001     0.000001     0.000000     0.000001    -0.000002     0.000000     0.000000    -0.000001     0.000001 
  831.374    -0.000000     0.000001    -0.000001     0.000001     0.000002     0.000001    -0.000000    -0.000001    -0.000002     0.000001     0.000001    -0.000000     0.000000 
  834.351    -0.000001     0.000000    -0.000000     0.000001     0.000002    -0.000000    -0.000000    -0.000001    -0.000001     0.000002    -0.000000     0.000000     0.000001 
  837.382    -0.000001     0.000001     0.000000     0.000001     0.000001     0.000000    -0.000000    -0.000000    -0.000001     0.000001     0.000001    -0.000001     0.000001 
  840.357    -0.000002     0.000001     0.000001    -0.000001     0.000000     0.000000    -0.000001     0.000001    -0.000001     0.000001     0.000001    -0.000001     0.000001 
  843.387    -0.000001     0.000001     0.000001     0.000001     0.000001     0.000000    -0.000000     0.000000    -0.000001     0.000001     0.000001    -0.000000     0.000000 
  846.361    -0.000001     0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000001     0.000000    -0.000001     0.000001     0.000001    -0.000001     0.000000 
  849.389    -0.000001    -0.000001    -0.000002    -0.000000     0.000001     0.000001    -0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001 
  852.362    -0.000001     0.000001    -0.000000    -0.000000     0.000001     0.000000    -0.000001     0.000001    -0.000001     0.000001     0.000001    -0.000000     0.000002 
  855.389     0.000001     0.000002    -0.000000     0.000001     0.000002     0.000001     0.000001     0.000000    -0.000001     0.000001     0.000001     0.000001     0.000001 
  858.359     0.000000    -0.000000    -0.000000     0.000001     0.000002     0.000000     0.000001     0.000002    -0.000001     0.000001     0.000001     0.000001     0.000001 
  861.385    -0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000001     0.000001    -0.000002     0.000001    -0.000000    -0.000000     0.000000 
  864.409     0.000000     0.000001    -0.000000     0.000001     0.000000     0.000001    -0.000000     0.000001    -0.000001     0.000001     0.000001    -0.000000     0.000000 
  867.378    -0.000001     0.000001    -0.000002     0.000000     0.000001    -0.000000     0.000000     0.000001    -0.000002     0.000001     0.000000    -0.000000    -0.000002 
  870.400    -0.000000     0.000001    -0.000001     0.000000     0.000001     0.000001     0.000000     0.000000    -0.000003     0.000001     0.000001    -0.000000    -0.000001 
  873.422    -0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000000    -0.000001     0.000002    -0.000001     0.000001     0.000001    -0.000001    -0.000001 
  876.389    -0.000001     0.000000    -0.000001     0.000001     0.000001     0.000000    -0.000001     0.000002    -0.000001     0.000002     0.000001    -0.000001    -0.000001 
  879.409     0.000000     0.000000    -0.000001    -0.000000     0.000001     0.000001     0.000000     0.000000    -0.000001    -0.000000     0.000001    -0.000000    -0.000000 
  882.428     0.000001     0.000001    -0.000001    -0.000000     0.000001     0.000000    -0.000000    -0.000001    -0.000001    -0.000000     0.000003     0.000000    -0.000001 
  885.447     0.000001     0.000001     0.000000     0.000001     0.000002     0.000000     0.000000     0.000000    -0.000002     0.000002     0.000002     0.000001    -0.000001 
  888.410     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000002    -0.000002     0.000002     0.000002     0.000013    -0.000000 
  891.427     0.000002     0.000001     0.000001     0.000004     0.000001     0.000000     0.000001     0.000015    -0.000001     0.000002     0.000001     0.000021     0.000001 
  894.444     0.000005     0.000004     0.000013     0.000007     0.000005     0.000002     0.000013     0.000003     0.000003     0.000003     0.000003     0.000000     0.000001 
  897.459     0.000003     0.000006    -0.000001     0.000004     0.000003     0.000005     0.000003     0.000003     0.000005     0.000005     0.000007     0.000003     0.000004 
  900.419     0.000003     0.000003     0.000002     0.000003     0.000003     0.000003     0.000003     0.000002     0.000003     0.000004     0.000006     0.000001     0.000004 
  903.433     0.000002     0.000003     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002     0.000003     0.000001     0.000002 
  906.446     0.000001     0.000002     0.000001     0.000002     0.000003     0.000001     0.000001     0.000002    -0.000000     0.000002     0.000002     0.000002     0.000002 
  909.458     0.000001     0.000001     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000000     0.000001     0.000002     0.000003     0.000001 
  912.469     0.000002     0.000001     0.000001     0.000002     0.000002     0.000002     0.000001     0.000016     0.000001     0.000002     0.000001     0.000020     0.000001 
  915.480     0.000002     0.000002     0.000007     0.000019     0.000008     0.000002     0.000001     0.000028     0.000002     0.000007     0.000002     0.000034     0.000007 
  918.489     0.000019     0.000015     0.000016     0.000033     0.000020     0.000008     0.000015     0.000031     0.000016     0.000007     0.000012     0.000030     0.000013 
  921.443     0.000030     0.000025     0.000031     0.000032     0.000034     0.000018     0.000026     0.000021     0.000027     0.000018     0.000020     0.000015     0.000020 
  924.451     0.000026     0.000034     0.000034     0.000013     0.000033     0.000025     0.000034     0.000002     0.000034     0.000020     0.000034     0.000001     0.000033 
  927.458     0.000013     0.000024     0.000011     0.000005     0.000017     0.000025     0.000019     0.000002     0.000020     0.000022     0.000025     0.000001     0.000025 
  930.465     0.000001     0.000011     0.000001    -0.000000     0.000001     0.000016     0.000002     0.000001     0.000002     0.000015     0.000004     0.000000     0.000013 
  933.470     0.000001     0.000001     0.000001     0.000000     0.000002     0.000002     0.000002     0.000001     0.000002     0.000002     0.000003    -0.000000     0.000002 
  936.475     0.000001     0.000001     0.000001     0.000000     0.000001     0.000002     0.000001     0.000000     0.000001     0.000003     0.000002    -0.000000     0.000001 
  939.478     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000001    -0.000001     0.000001 
  942.481     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000    -0.000001     0.000000     0.000001    -0.000001    -0.000000 
  945.483     0.000001     0.000000    -0.000001     0.000000    -0.000001    -0.000001     0.000000    -0.000000    -0.000001     0.000001     0.000001    -0.000001    -0.000001 
  948.484     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000 
  951.484     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000001     0.000001     0.000001    -0.000000    -0.000000 
  954.538     0.000001    -0.000000    -0.000000    -0.000000     0.000001    -0.000000     0.000001    -0.000000    -0.000001     0.000002     0.000001    -0.000000     0.000000 
  957.537     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000    -0.000001    -0.000000 
  960.534     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000 
  963.531     0.000000    -0.000001     0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  966.526     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000 
  969.521     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
  972.515     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000001 
  975.563     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000001 
  978.555     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
  981.546     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000001    -0.000000 
  984.537    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  987.580     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  990.569     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000001     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000 
  993.556     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000 
  996.543     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000001 
  999.583     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000 
 1002.568    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000 
 1005.552     0.000000     0.000000     0.000002     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000000 
 1008.589     0.000001     0.000000     0.000003     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000002     0.000001 
 1011.571     0.000001     0.000001     0.000016     0.000001     0.000001     0.000002     0.000001     0.000002     0.000001     0.000001     0.000001     0.000002     0.000001 
 1014.606     0.000001     0.000002     0.000015     0.000002     0.000002     0.000001     0.000001     0.000002     0.000002     0.000001     0.000002     0.000002     0.000001 
 1017.587     0.000002     0.000002     0.000019     0.000003     0.000002     0.000001     0.000001     0.000003     0.000002     0.000001     0.000002     0.000003     0.000002 
 1020.620     0.000003     0.000003     0.000021     0.000002     0.000002     0.000002     0.000002     0.000003     0.000002     0.000001     0.000002     0.000003     0.000001 
 1023.598     0.000003     0.000002     0.000031     0.000002     0.000003     0.000002     0.000002     0.000003     0.000002     0.000002     0.000002     0.000002     0.000002 
 1026.629     0.000003     0.000002     0.000018     0.000003     0.000003     0.000002     0.000002     0.000003     0.000002     0.000002     0.000001     0.000003     0.000002 
 1029.606     0.000002     0.000002     0.000022     0.000003     0.000003     0.000003     0.000002     0.000003     0.000002     0.000002     0.000002     0.000003     0.000002 
 1032.635     0.000002     0.000002     0.000021     0.000003     0.000002     0.000002     0.000003     0.000004     0.000001     0.000001     0.000003     0.000004     0.000002 
 1035.610     0.000003     0.000003     0.000025     0.000004     0.000003     0.000002     0.000003     0.000003     0.000003     0.000002     0.000002     0.000004     0.000002 
 1038.637     0.000003     0.000003     0.000020     0.000003     0.000003     0.000003     0.000003     0.000003     0.000002     0.000002     0.000002     0.000003     0.000002 
 1041.610     0.000003     0.000004     0.000025     0.000002     0.000003     0.000002     0.000003     0.000004     0.000002     0.000001     0.000003     0.000004     0.000003 
 1044.635     0.000003     0.000003     0.000029     0.000003     0.000004     0.000003     0.000003     0.000005     0.000003     0.000001     0.000003     0.000004     0.000002 
 1047.660     0.000003     0.000002     0.000027     0.000003     0.000004     0.000004     0.000003     0.000009     0.000003     0.000002     0.000003     0.000004     0.000002 
 1050.629     0.000004     0.000004     0.000026     0.000004     0.000005     0.000004     0.000004     0.000005     0.000004     0.000003     0.000004     0.000004     0.000002 
 1053.652     0.000004     0.000003     0.000016     0.000004     0.000005     0.000003     0.000004     0.000006     0.000005     0.000003     0.000003     0.000006     0.000001 
 1056.620     0.000004     0.000004     0.000022     0.000004     0.000005     0.000004     0.000004     0.000012     0.000003     0.000004     0.000004     0.000007     0.000003 
 1059.640     0.000004     0.000004     0.000028     0.000004     0.000005     0.000004     0.000003     0.000007     0.000004     0.000003     0.000005     0.000006     0.000004 
 1062.660     0.000005     0.000004     0.000032     0.000005     0.000004     0.000003     0.000004     0.000005     0.000005     0.000003     0.000004     0.000006     0.000003 
 1065.678     0.000004     0.000004     0.000033     0.000005     0.000005     0.000004     0.000004     0.000004     0.000004     0.000003     0.000004     0.000008     0.000003 
 1068.642     0.000007     0.000005     0.000018     0.000008     0.000005     0.000004     0.000005     0.000007     0.000006     0.000003     0.000005     0.000008     0.000004 
 1071.658     0.000007     0.000005     0.000034     0.000005     0.000006     0.000005     0.000002     0.000008     0.000005     0.000004     0.000004     0.000008     0.000004 
 1074.674     0.000007     0.000003     0.000020     0.000006     0.000005     0.000005     0.000005     0.000006     0.000004     0.000004     0.000004     0.000009     0.000002 
 1077.688     0.000006     0.000004     0.000014     0.000007     0.000006     0.000006     0.000005     0.000006     0.000004     0.000005     0.000005     0.000009     0.000004 
 1080.702     0.000007     0.000005     0.000011     0.000008     0.000008     0.000005     0.000005     0.000009     0.000004     0.000005     0.000005     0.000009     0.000001 
 1083.660     0.000007     0.000006     0.000012     0.000009     0.000009     0.000005     0.000007     0.000010     0.000006     0.000002     0.000007     0.000010     0.000005 
 1086.672     0.000008     0.000006     0.000011     0.000011     0.000009     0.000008     0.000007     0.000008     0.000006     0.000006     0.000006     0.000011     0.000006 
 1089.682     0.000008     0.000005     0.000011     0.000010     0.000006     0.000007     0.000010     0.000012     0.000005     0.000004     0.000006     0.000013     0.000006 
 1092.691     0.000005     0.000008     0.000010     0.000011     0.000007     0.000005     0.000006     0.000011     0.000006     0.000004     0.000008     0.000015     0.000003 
 1095.699     0.000006     0.000008     0.000009     0.000011     0.000009     0.000006     0.000006     0.000015     0.000006     0.000000     0.000006     0.000019     0.000004 
 1098.707     0.000008     0.000007     0.000007     0.000013     0.000009     0.000002     0.000006     0.000019     0.000007    -0.000002     0.000010     0.000047     0.000004 
 1101.713     0.000008     0.000004     0.000009     0.000009     0.000010     0.000003     0.000001     0.000016     0.000006     0.000001     0.000006     0.000036     0.000004 
 1104.718     0.000012     0.000001     0.000011     0.000014     0.000013     0.000004     0.000005     0.000018     0.000006    -0.000002     0.000007     0.000042     0.000003 
 1107.722     0.000005     0.000003     0.000005     0.000009     0.000013     0.000005     0.000003     0.000017     0.000003    -0.000001     0.000007     0.000050     0.000006 
 1110.725     0.000004    -0.000001     0.000003     0.000010     0.000008     0.000003     0.000007     0.000019     0.000002    -0.000003     0.000008     0.000066     0.000001 
 1113.727     0.000005     0.000001     0.000003     0.000012     0.000009    -0.000002     0.000006     0.000018     0.000006     0.000005     0.000004     0.000057     0.000001 
 1116.728     0.000007     0.000005     0.000009     0.000011     0.000008     0.000009     0.000005     0.000017     0.000005    -0.000008     0.000005     0.000013     0.000008 
 1119.728     0.000012     0.000005     0.000011     0.000018     0.000009     0.000004     0.000005     0.000019     0.000003    -0.000003     0.000005     0.000021    -0.000005 
 1122.726     0.000012     0.000010     0.000013     0.000018     0.000003     0.000008    -0.000003     0.000022     0.000007    -0.000005     0.000007     0.000034     0.000005 
 1125.724     0.000009     0.000002     0.000010     0.000019     0.000011     0.000007     0.000002     0.000027    -0.000002    -0.000002     0.000007     0.000037     0.000001 
 1128.720     0.000005     0.000002     0.000001     0.000025     0.000005     0.000004     0.000003     0.000030    -0.000003     0.000004     0.000012     0.000045    -0.000005 
 1131.770     0.000008     0.000006     0.000003     0.000015     0.000004     0.000007     0.000005     0.000024     0.000007    -0.000003     0.000001     0.000049     0.000001 
 1134.764     0.000015     0.000008     0.000007     0.000024     0.000003     0.000007     0.000008     0.000036     0.000002    -0.000006     0.000008     0.000048     0.000007 
 1137.757     0.000011    -0.000009     0.000014     0.000033     0.000019    -0.000007     0.000003     0.000044    -0.000004    -0.000010     0.000011     0.000058     0.000013 
 1140.749     0.000016    -0.000007     0.000015     0.000028     0.000021     0.000011    -0.000006     0.000047     0.000000    -0.000000     0.000010     0.000186    -0.000001 
 1143.741     0.000018    -0.000001     0.000007     0.000028     0.000033     0.000008     0.000013     0.000063     0.000013    -0.000005     0.000024     0.000291     0.000014 
 1146.784     0.000020     0.000002     0.000014     0.000035     0.000029     0.000011     0.000001     0.000076    -0.000005     0.000002     0.000027     0.000358    -0.000006 
 1149.773     0.000007    -0.000004     0.000034     0.000052     0.000020     0.000025     0.000017     0.000092    -0.000002    -0.000001     0.000040     0.000218     0.000012 
 1152.761     0.000034     0.000031     0.000010     0.000088     0.000030     0.000043     0.000030     0.000113     0.000019     0.000003     0.000035     0.000430     0.000006 
 1155.801     0.000039    -0.000010     0.000020     0.000085     0.000031     0.000030     0.000006     0.000135    -0.000003     0.000016     0.000024     0.000420     0.000003 
 1158.786     0.000046     0.000038     0.000034     0.000100     0.000056    -0.000009     0.000031     0.000168     0.000040    -0.000001     0.000038     0.000256     0.000013 
 1161.771     0.000096     0.000080     0.000058     0.000120     0.000055     0.000042     0.000073     0.000160     0.000042    -0.000024     0.000039     0.000370     0.000010 
 1164.807     0.000116     0.000054     0.000070     0.000095     0.000066     0.000022     0.000038     0.000158     0.000016    -0.000023     0.000054     0.000085     0.000040 
 1167.790     0.000073     0.000032     0.000060     0.000169     0.000108     0.000062     0.000056     0.000177     0.000089    -0.000054     0.000067     0.000174    -0.000003 
 1170.771     0.000060     0.000052     0.000110     0.000072     0.000127     0.000046     0.000060     0.000170     0.000080    -0.000013     0.000108     0.000134     0.000008 
 1173.804     0.000130     0.000010     0.000139     0.000209     0.000177    -0.000044     0.000084     0.000270     0.000034     0.000028     0.000119     0.000235     0.000088 
 1176.783     0.000201     0.000040     0.000117     0.000226     0.000223     0.000076     0.000227     0.000296     0.000077     0.000091     0.000112     0.000192     0.000064 
 1179.814     0.000091     0.000182     0.000348     0.000328     0.000171     0.000320     0.000054     0.000169     0.000202     0.000070     0.000220     0.000116     0.000142 
 1182.790     0.000350     0.000091     0.000214     0.000081     0.000408     0.000340     0.000243     0.000294    -0.000044     0.000044     0.000423    -0.000113     0.000038 
 1185.819     0.000447     0.000256    -0.000153     0.000172     0.000378     0.000429    -0.000324    -0.000047     0.000014     0.000404     0.000536    -0.000003     0.000117 
 1188.793     0.000366     0.000309    -0.000014     0.000124     0.000538     0.000350    -0.000137     0.000530    -0.000066    -0.000100     0.000896    -0.000257    -0.000110 
 1191.820     0.000334     0.000366    -0.000017    -0.000252     0.000838     0.000910     0.000438    -0.000068     0.000318    -0.000218     0.000467     0.000297    -0.000131 
 1194.845     0.000865     0.000311    -0.000375    -0.000531     0.000752     0.000254     0.000869     0.000272    -0.000326     0.000094     0.000783     0.000702    -0.000154 
 1197.815    -0.000651     0.000647     0.000537     0.000065     0.001299     0.000299    -0.000225    -0.000510    -0.000662     0.000250     0.000374     0.000414    -0.000455 
 1200.838    -0.000441     0.000771     0.000468     0.000731     0.001053     0.000677     0.000390     0.000706     0.000034    -0.000032     0.000443     0.000656    -0.000214 