# number of points on sci filter + aux + bad z = 2
# number of points on sci filter               = 2
# number of positions in lambda                = 301
# noof scans  1            1          
# x_pos     162.640000  -162.640000 
# y_pos       0.000000     0.000000 
# angle       2.960000     2.960000 
# z_pos      10.000000    10.000000 
# r_pos     162.640000   162.640000 
# phi         0.000000     3.141593 
# gnupl col      2            3      
# pos_id        49           50      
#
# lambda for peak transmission
#          582.0170000  582.0170000 
# peak transmission
#            0.8990060    0.8963700 
# lambda blue with 1/2 of peak transmission
#          502.9437651  502.4643631 
# lambda red  with 1/2 of peak transmission
#          600.6638365  599.6514584 
# half width                              
#           97.7200714   97.1870953 
# central wavelength                      
#          551.8038008  551.0579108 
# central wavelength calculated as SAGEM (mean frequency)
#          547.4774387  546.7728205 
# lambda blue with 80% of peak transmission
#          506.6028930  506.7444895 
# lambda red  with 80% of peak transmission
#          597.9087043  597.1531738 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.8334278    0.8282027 
# ATB calculated from points above 50%
#            0.8154394    0.8219104 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000 
# minCWL      = 551.057911 at column =  3, at id = 50 
# maxCWL      = 551.803801 at column =  2, at id = 49 
# difference =    0.7458901 
# minBW       = 97.187095 at column =  3, at id = 50 
# maxBW       = 97.720071 at column =  2, at id = 49 
# difference =    0.5329761 
# minATB80    = 0.828203 at column =  3, at id = 50 
# maxATB80    = 0.833428 at column =  2, at id = 49 
# difference =    0.0052252 
# minBlueEdge = 502.464363 at column =  3, at id = 50 
# maxBlueEdge = 502.943765 at column =  2, at id = 49 
# difference =    0.4794020 
# minRedEdge  = 599.651458 at column =  3, at id = 50 
# maxRedEdge  = 600.663837 at column =  2, at id = 49 
# difference =    1.0123781 
# minABR      = 9.999900 at column =  2, at id = 49 
# maxABR      = 9.999900 at column =  2, at id = 49 
# difference =    0.0000000 
  299.645    -0.000330     0.000024 
  302.654    -0.000088    -0.000173 
  305.662    -0.000045     0.000003 
  308.671     0.000032     0.000030 
  311.679    -0.000025    -0.000005 
  314.687     0.000003    -0.000010 
  317.694     0.000022    -0.000013 
  320.702     0.000054     0.000001 
  323.709     0.000032    -0.000023 
  326.716     0.000019    -0.000017 
  329.665     0.000024    -0.000009 
  332.672     0.000026     0.000009 
  335.678     0.000007    -0.000001 
  338.683     0.000016    -0.000001 
  341.689     0.000013    -0.000006 
  344.694     0.000007     0.000003 
  347.699     0.000004     0.000004 
  350.703     0.000005    -0.000002 
  353.707     0.000010    -0.000001 
  356.711     0.000007    -0.000004 
  359.715     0.000004    -0.000001 
  362.718     0.000004    -0.000002 
  365.721     0.000006    -0.000004 
  368.724     0.000010     0.000003 
  371.726     0.000010    -0.000000 
  374.728     0.000006    -0.000001 
  377.730     0.000005    -0.000000 
  380.788     0.000005     0.000001 
  383.789     0.000006    -0.000001 
  386.789     0.000002     0.000000 
  389.790     0.000002     0.000001 
  392.790     0.000003     0.000000 
  395.790     0.000001     0.000000 
  398.789     0.000001     0.000001 
  401.788     0.000004    -0.000001 
  404.787     0.000003     0.000000 
  407.785     0.000002    -0.000001 
  410.783     0.000002     0.000001 
  413.781     0.000003     0.000000 
  416.834     0.000002    -0.000000 
  419.831     0.000001    -0.000000 
  422.828     0.000003     0.000000 
  425.824     0.000002     0.000001 
  428.820     0.000001     0.000000 
  431.815     0.000002     0.000000 
  434.810     0.000002     0.000001 
  437.862     0.000001    -0.000000 
  440.856     0.000001     0.000000 
  443.850     0.000001     0.000000 
  446.844     0.000001    -0.000000 
  449.837     0.000002     0.000000 
  452.830     0.000002    -0.000000 
  455.878     0.000002     0.000001 
  458.870     0.000001     0.000000 
  461.862     0.000002     0.000001 
  464.853     0.000002     0.000001 
  467.901     0.000002     0.000001 
  470.891     0.000021     0.000020 
  473.881     0.000041     0.000040 
  476.871     0.000053     0.000061 
  479.916     0.000137     0.000142 
  482.905     0.000397     0.000448 
  485.894     0.000653     0.000656 
  488.882     0.001632     0.001860 
  491.925     0.004095     0.005124 
  494.913     0.015459     0.018299 
  497.899     0.055087     0.069853 
  500.942     0.217915     0.263561 
  503.928     0.563371     0.625687 
  506.913     0.737271     0.722565 
  509.954     0.737024     0.735179 
  512.939     0.755360     0.750895 
  515.923     0.775550     0.773299 
  518.963     0.748095     0.744201 
  521.946     0.812488     0.824239 
  524.929     0.823778     0.822059 
  527.967     0.831356     0.835056 
  530.949     0.835816     0.833808 
  533.987     0.857215     0.854678 
  536.968     0.854371     0.854841 
  539.948     0.845725     0.839123 
  542.984     0.797511     0.797404 
  545.964     0.783385     0.776793 
  548.999     0.787312     0.785770 
  551.977     0.815178     0.805592 
  555.012     0.835958     0.833622 
  557.989     0.850600     0.839120 
  561.023     0.844156     0.839681 
  563.999     0.872093     0.878052 
  567.032     0.895884     0.894094 
  570.007     0.867864     0.859935 
  573.038     0.869054     0.873352 
  576.013     0.882288     0.875084 
  579.043     0.889087     0.890812 
  582.017     0.899006     0.896370 
  585.046     0.894273     0.891716 
  588.019     0.893421     0.887784 
  591.047     0.879368     0.869716 
  594.019     0.865066     0.862616 
  597.046     0.802306     0.728632 
  600.073     0.510726     0.402811 
  603.043     0.202972     0.131030 
  606.068     0.047755     0.032154 
  609.038     0.015573     0.010193 
  612.062     0.004504     0.003208 
  615.086     0.001822     0.001255 
  618.053     0.000624     0.000458 
  621.076     0.000318     0.000245 
  624.099     0.000152     0.000107 
  627.064     0.000079     0.000066 
  630.086     0.000056     0.000046 
  633.106     0.000032     0.000023 
  636.071     0.000014     0.000008 
  639.090     0.000014     0.000013 
  642.109     0.000014     0.000008 
  645.128     0.000002     0.000002 
  648.090     0.000003     0.000002 
  651.107     0.000002     0.000002 
  654.123     0.000003     0.000002 
  657.139     0.000002     0.000001 
  660.099     0.000002     0.000001 
  663.114     0.000002     0.000001 
  666.129     0.000002     0.000000 
  669.142     0.000002     0.000000 
  672.155     0.000001     0.000001 
  675.168     0.000001    -0.000000 
  678.124     0.000001    -0.000000 
  681.136     0.000002     0.000001 
  684.146     0.000002     0.000001 
  687.157     0.000001     0.000001 
  690.166     0.000001     0.000000 
  693.175     0.000001     0.000001 
  696.183     0.000002     0.000001 
  699.191     0.000001     0.000000 
  702.198     0.000001     0.000001 
  705.205     0.000002     0.000001 
  708.211     0.000001     0.000001 
  711.216     0.000002     0.000000 
  714.220     0.000002     0.000002 
  717.224     0.000004     0.000002 
  720.228     0.000003     0.000002 
  723.230     0.000011     0.000022 
  726.232     0.000021     0.000018 
  729.234     0.000001     0.000007 
  732.234     0.000027     0.000045 
  735.235     0.000099     0.000089 
  738.234     0.000089     0.000099 
  741.233     0.000090     0.000047 
  744.231     0.000003     0.000000 
  747.228     0.000004     0.000002 
  750.225     0.000003     0.000001 
  753.221     0.000025     0.000024 
  756.272     0.000126     0.000221 
  759.267     0.000451     0.000286 
  762.261     0.000039     0.000001 
  765.254     0.000003     0.000003 
  768.247     0.000002     0.000001 
  771.294     0.000002     0.000001 
  774.286     0.000002     0.000001 
  777.277     0.000029     0.000028 
  780.266     0.000038     0.000028 
  783.311     0.000027     0.000000 
  786.300     0.000004     0.000007 
  789.288     0.000002     0.000000 
  792.275     0.000003    -0.000000 
  795.316     0.000002    -0.000001 
  798.302     0.000001    -0.000001 
  801.287     0.000001    -0.000000 
  804.327     0.000001     0.000000 
  807.310     0.000001     0.000001 
  810.348     0.000002     0.000000 
  813.331     0.000002     0.000001 
  816.312     0.000002     0.000000 
  819.348     0.000001     0.000000 
  822.328     0.000002    -0.000000 
  825.362     0.000002    -0.000000 
  828.341     0.000002     0.000002 
  831.374     0.000001     0.000001 
  834.351     0.000002    -0.000000 
  837.382     0.000001     0.000000 
  840.357     0.000001     0.000001 
  843.387     0.000002    -0.000001 
  846.361     0.000002    -0.000000 
  849.389     0.000001    -0.000001 
  852.362     0.000002    -0.000000 
  855.389     0.000001    -0.000001 
  858.359     0.000002    -0.000000 
  861.385     0.000002    -0.000002 
  864.409     0.000002    -0.000002 
  867.378     0.000001    -0.000001 
  870.400     0.000001     0.000000 
  873.422     0.000001     0.000000 
  876.389     0.000001    -0.000001 
  879.409     0.000002    -0.000000 
  882.428     0.000001    -0.000001 
  885.447     0.000001    -0.000000 
  888.410     0.000002     0.000001 
  891.427     0.000002    -0.000001 
  894.444     0.000002    -0.000001 
  897.459     0.000002     0.000000 
  900.419     0.000001    -0.000000 
  903.433     0.000001    -0.000000 
  906.446     0.000002     0.000001 
  909.458     0.000002     0.000001 
  912.469     0.000001     0.000001 
  915.480     0.000001     0.000001 
  918.489     0.000000     0.000000 
  921.443     0.000000     0.000000 
  924.451     0.000000     0.000000 
  927.458     0.000001     0.000001 
  930.465     0.000002     0.000001 
  933.470     0.000002     0.000002 
  936.475     0.000001     0.000001 
  939.478     0.000001     0.000001 
  942.481     0.000001     0.000001 
  945.483     0.000001     0.000001 
  948.484     0.000001     0.000001 
  951.484     0.000001     0.000000 
  954.538    -0.000000     0.000000 
  957.537     0.000001     0.000001 
  960.534     0.000018     0.000008 
  963.531     0.000020     0.000015 
  966.526     0.000002     0.000001 
  969.521     0.000002     0.000002 
  972.515     0.000000    -0.000000 
  975.563    -0.000000    -0.000000 
  978.555    -0.000000    -0.000000 
  981.546    -0.000000    -0.000000 
  984.537    -0.000000    -0.000000 
  987.580     0.000000    -0.000001 
  990.569     0.000000    -0.000000 
  993.556     0.000000    -0.000000 
  996.543     0.000001     0.000000 
  999.583     0.000000     0.000000 
 1002.568     0.000001     0.000000 
 1005.552     0.000001     0.000001 
 1008.589     0.000001     0.000000 
 1011.571     0.000001     0.000000 
 1014.606     0.000000    -0.000000 
 1017.587    -0.000000    -0.000000 
 1020.620     0.000001    -0.000000 
 1023.598     0.000001    -0.000000 
 1026.629     0.000001    -0.000000 
 1029.606     0.000001    -0.000000 
 1032.635     0.000001     0.000000 
 1035.610     0.000001     0.000000 
 1038.637     0.000001     0.000000 
 1041.610    -0.000000    -0.000000 
 1044.635     0.000000     0.000000 
 1047.660    -0.000000     0.000000 
 1050.629    -0.000001     0.000000 
 1053.652     0.000001    -0.000000 
 1056.620     0.000001    -0.000000 
 1059.640    -0.000000    -0.000002 
 1062.660     0.000001    -0.000002 
 1065.678     0.000002    -0.000002 
 1068.642     0.000001    -0.000003 
 1071.658     0.000002    -0.000003 
 1074.674     0.000003    -0.000004 
 1077.688     0.000003    -0.000003 
 1080.702     0.000003    -0.000001 
 1083.660     0.000003     0.000003 
 1086.672     0.000004     0.000003 
 1089.682     0.000002     0.000003 
 1092.691     0.000003     0.000003 
 1095.699     0.000005     0.000005 
 1098.707     0.000006     0.000005 
 1101.713     0.000005     0.000007 
 1104.718     0.000007     0.000007 
 1107.722     0.000011     0.000011 
 1110.725     0.000013     0.000002 
 1113.727     0.000010     0.000010 
 1116.728     0.000011     0.000007 
 1119.728     0.000015     0.000009 
 1122.726     0.000011     0.000012 
 1125.724     0.000010     0.000010 
 1128.720     0.000009     0.000018 
 1131.770     0.000006     0.000010 
 1134.764     0.000014     0.000013 
 1137.757     0.000021     0.000025 
 1140.749     0.000024     0.000032 
 1143.741     0.000017     0.000028 
 1146.784     0.000032     0.000048 
 1149.773     0.000034     0.000055 
 1152.761     0.000074     0.000055 
 1155.801     0.000094     0.000059 
 1158.786     0.000105     0.000079 
 1161.771     0.000125     0.000071 
 1164.807     0.000143     0.000106 
 1167.790     0.000168     0.000113 
 1170.771     0.000223     0.000143 
 1173.804     0.000214     0.000195 
 1176.783     0.000324     0.000316 
 1179.814     0.000453     0.000369 
 1182.790     0.000453     0.000384 
 1185.819     0.000793     0.001046 
 1188.793     0.001214     0.000770 
 1191.820     0.001830     0.000914 
 1194.845     0.001325     0.000831 
 1197.815     0.001582     0.000309 
 1200.838     0.002355     0.001812 
