# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 71
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       2.110000     2.110000     1.490000     1.490000     2.500000     2.500000     1.320000     1.320000 
# z_pos      57.000000    57.000000    56.000000    56.000000    58.000000    58.000000    55.000000    55.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       121          122          123          124          125          126          127          128      
#
# lambda for peak transmission
#          567.0320000  582.0170000  582.0170000  567.0320000  567.0320000  582.0170000  582.0170000  567.0320000 
# peak transmission
#            0.7099938    0.7149320    0.7222444    0.7146204    0.7032869    0.7146746    0.7276870    0.7167757 
# lambda blue with 1/2 of peak transmission
#          502.1532108  502.4264244  502.6451386  502.4192053  501.7708270  502.3570735  502.5942569  502.3565188 
# lambda red  with 1/2 of peak transmission
#          599.2508679  599.0337715  598.8551829  599.1988112  599.1574895  598.9966976  598.2519262  599.3069427 
# half width                              
#           97.0976570   96.6073471   96.2100443   96.7796059   97.3866625   96.6396241   95.6576693   96.9504239 
# central wavelength                      
#          550.7020394  550.7300980  550.7501607  550.8090083  550.4641582  550.6768855  550.4230916  550.8317308 
# central wavelength calculated as SAGEM (mean frequency)
#          546.4220684  546.4934585  546.5484495  546.5578559  546.1568106  546.4370050  546.2670206  546.5657344 
# lambda blue with 80% of peak transmission
#          505.2379368  506.0194925  506.4200999  505.8113380  503.8867245  505.9720794  506.7441404  505.6486411 
# lambda red  with 80% of peak transmission
#          596.7171252  596.4424624  596.2665007  596.7519137  596.4138750  596.3263396  595.5928628  596.9075864 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.6799330    0.6812300    0.6897739    0.6864598    0.6697790    0.6779413    0.6947331    0.6894052 
# ATB calculated from points above 50%
#            0.6716308    0.6717527    0.6790135    0.6771928    0.6654412    0.6686678    0.6822620    0.6804684 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 550.423092 at column =  8, at id = 127 
# maxCWL      = 550.831731 at column =  9, at id = 128 
# difference =    0.4086392 
# minBW       = 95.657669 at column =  8, at id = 127 
# maxBW       = 97.386663 at column =  6, at id = 125 
# difference =    1.7289932 
# minATB80    = 0.669779 at column =  6, at id = 125 
# maxATB80    = 0.694733 at column =  8, at id = 127 
# difference =    0.0249542 
# minBlueEdge = 501.770827 at column =  6, at id = 125 
# maxBlueEdge = 502.645139 at column =  4, at id = 123 
# difference =    0.8743116 
# minRedEdge  = 598.251926 at column =  8, at id = 127 
# maxRedEdge  = 599.306943 at column =  9, at id = 128 
# difference =    1.0550165 
# minABR      = 9.999900 at column =  2, at id = 121 
# maxABR      = 9.999900 at column =  2, at id = 121 
# difference =    0.0000000 
  449.837     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000002     0.000001     0.000002 
  452.830     0.000000     0.000001    -0.000002     0.000001     0.000001     0.000001     0.000001     0.000002 
  455.878    -0.000001     0.000001    -0.000001     0.000001     0.000000     0.000002     0.000001     0.000000 
  458.870     0.000001     0.000001     0.000000     0.000001     0.000001     0.000002     0.000002     0.000001 
  461.862     0.000002     0.000002     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001 
  464.853     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000002     0.000001     0.000002 
  467.901     0.000007     0.000002     0.000001     0.000002     0.000007     0.000002     0.000002     0.000002 
  470.891     0.000017     0.000017     0.000017     0.000019     0.000022     0.000021     0.000017     0.000017 
  473.881     0.000029     0.000027     0.000026     0.000031     0.000036     0.000030     0.000022     0.000032 
  476.871     0.000056     0.000051     0.000048     0.000052     0.000069     0.000054     0.000051     0.000052 
  479.916     0.000126     0.000113     0.000102     0.000117     0.000143     0.000114     0.000104     0.000120 
  482.905     0.000396     0.000353     0.000322     0.000361     0.000446     0.000357     0.000318     0.000376 
  485.894     0.000552     0.000483     0.000432     0.000493     0.000644     0.000496     0.000418     0.000515 
  488.882     0.001634     0.001439     0.001303     0.001463     0.001883     0.001472     0.001276     0.001520 
  491.925     0.004623     0.003975     0.003532     0.003974     0.005732     0.004153     0.003684     0.004105 
  494.913     0.016052     0.013745     0.012137     0.013849     0.019649     0.014336     0.012051     0.014423 
  497.899     0.061891     0.053164     0.046868     0.053165     0.076720     0.055641     0.048297     0.055425 
  500.942     0.228164     0.200037     0.178036     0.200422     0.268997     0.208033     0.179954     0.208313 
  503.928     0.540845     0.516714     0.499029     0.517553     0.566745     0.523086     0.512284     0.525116 
  506.913     0.602713     0.595541     0.593374     0.603368     0.599913     0.594136     0.586339     0.608916 
  509.954     0.615389     0.611969     0.614288     0.616637     0.614602     0.613038     0.620471     0.621184 
  512.939     0.625898     0.625737     0.626952     0.627662     0.622914     0.626670     0.632292     0.631662 
  515.923     0.645920     0.648768     0.654626     0.651353     0.636491     0.646219     0.655831     0.653731 
  518.963     0.616725     0.615316     0.618569     0.618054     0.619112     0.615401     0.626026     0.621433 
  521.946     0.681832     0.683934     0.687335     0.682696     0.679084     0.683890     0.695242     0.685574 
  524.929     0.683844     0.686688     0.693692     0.687857     0.677687     0.682895     0.701801     0.689638 
  527.967     0.699351     0.702345     0.715349     0.708617     0.689833     0.697056     0.721917     0.710646 
  530.949     0.689373     0.692842     0.703166     0.697571     0.681974     0.691293     0.710122     0.700454 
  533.987     0.695731     0.699615     0.705873     0.699520     0.688898     0.701261     0.709561     0.702415 
  536.968     0.700753     0.705421     0.711305     0.703590     0.693670     0.704931     0.720203     0.705221 
  539.948     0.696921     0.698967     0.708438     0.703388     0.685580     0.689518     0.709550     0.705232 
  542.984     0.684705     0.677784     0.694382     0.693406     0.676682     0.658849     0.700488     0.696210 
  545.964     0.675612     0.663972     0.686080     0.690963     0.664100     0.642388     0.688319     0.696604 
  548.999     0.677547     0.668095     0.688206     0.695239     0.666499     0.653093     0.692051     0.702832 
  551.977     0.674042     0.671812     0.685916     0.689608     0.663226     0.664526     0.688314     0.696914 
  555.012     0.685577     0.688552     0.698982     0.697178     0.677056     0.684857     0.703685     0.701710 
  557.989     0.676543     0.678288     0.686124     0.684633     0.670450     0.676026     0.687675     0.689118 
  561.023     0.675739     0.677854     0.687097     0.681422     0.673339     0.675807     0.696217     0.684627 
  563.999     0.704925     0.707246     0.714298     0.709113     0.701417     0.707740     0.723574     0.711373 
  567.032     0.709994     0.713296     0.719284     0.714620     0.703287     0.712140     0.722362     0.716776 
  570.007     0.689573     0.694598     0.704071     0.696859     0.681406     0.691065     0.711134     0.698015 
  573.038     0.701534     0.703961     0.714810     0.708112     0.695371     0.701614     0.721202     0.709840 
  576.013     0.692824     0.695866     0.704295     0.700341     0.686660     0.696396     0.709383     0.702726 
  579.043     0.703234     0.708505     0.715062     0.708003     0.698449     0.711206     0.723663     0.710144 
  582.017     0.708884     0.714932     0.722244     0.714083     0.701182     0.714675     0.727687     0.715007 
  585.046     0.706759     0.709836     0.719064     0.712787     0.699707     0.709783     0.725348     0.713822 
  588.019     0.700796     0.707018     0.715906     0.709345     0.691233     0.708304     0.722759     0.710862 
  591.047     0.689136     0.698976     0.707376     0.697138     0.677758     0.698567     0.714760     0.697775 
  594.019     0.686504     0.689682     0.697419     0.690986     0.678446     0.685445     0.694123     0.692005 
  597.046     0.553550     0.542625     0.536306     0.558860     0.532060     0.536275     0.478766     0.567738 
  600.073     0.280962     0.260663     0.243200     0.275467     0.273418     0.258608     0.190299     0.287455 
  603.043     0.080186     0.071274     0.062816     0.077210     0.076510     0.070730     0.043201     0.082562 
  606.068     0.020585     0.018016     0.016131     0.019322     0.020995     0.017966     0.012343     0.020546 
  609.038     0.006362     0.005595     0.004944     0.006065     0.006238     0.005580     0.003533     0.006483 
  612.062     0.002051     0.001776     0.001581     0.001900     0.002149     0.001789     0.001251     0.002029 
  615.086     0.000801     0.000710     0.000639     0.000765     0.000793     0.000709     0.000483     0.000819 
  618.053     0.000297     0.000259     0.000231     0.000277     0.000312     0.000261     0.000184     0.000294 
  621.076     0.000160     0.000141     0.000125     0.000150     0.000168     0.000142     0.000102     0.000159 
  624.099     0.000075     0.000066     0.000057     0.000070     0.000073     0.000060     0.000047     0.000073 
  627.064     0.000048     0.000040     0.000036     0.000043     0.000049     0.000040     0.000030     0.000044 
  630.086     0.000029     0.000028     0.000023     0.000031     0.000035     0.000026     0.000019     0.000031 
  633.106     0.000015     0.000014     0.000014     0.000013     0.000014     0.000014     0.000008     0.000014 
  636.071     0.000008     0.000008     0.000008     0.000008     0.000010     0.000005     0.000001     0.000008 
  639.090     0.000010     0.000010     0.000007     0.000008     0.000011     0.000004     0.000002     0.000010 
  642.109     0.000005     0.000004    -0.000000     0.000003     0.000001     0.000004     0.000001     0.000008 
  645.128     0.000001     0.000002     0.000001    -0.000001     0.000002     0.000001     0.000001    -0.000001 
  648.090     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  651.107     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  654.123     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  657.139     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000001 
  660.099     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001 