# number of points on sci filter + aux + bad z = 13
# number of points on sci filter               = 13
# number of positions in lambda                = 301
# noof scans  1            1            1            1            1            1            1            1            1            1            1            1            1          
# x_pos       0.000000    17.670000   -17.670000   -17.670000    17.670000    35.340000   -35.340000   -35.340000    35.340000    53.010000   -53.010000   -53.010000    53.010000 
# y_pos       0.000000    17.670000    17.670000   -17.670000   -17.670000    35.340000    35.340000   -35.340000   -35.340000    53.010000    53.010000   -53.010000   -53.010000 
# angle       1.780000     1.840000     2.230000     1.840000     1.320000     2.000000     2.690000     2.000000     0.870000     2.230000     3.140000     2.230000     0.410000 
# z_pos      44.000000    45.000000    47.000000    45.000000    43.000000    46.000000    48.000000    46.000000    42.000000    47.000000    49.000000    47.000000    41.000000 
# r_pos       0.000000    24.990000    24.990000    24.990000    24.990000    49.980000    49.980000    49.980000    49.980000    74.970000    74.970000    74.970000    74.970000 
# phi         0.000000     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602 
# gnupl col      2            3            4            5            6            7            8            9           10           11           12           13           14      
# pos_id       202          203          204          205          206          207          208          209          210          211          212          213          214      
#
# lambda for peak transmission
#          594.0190000  594.0190000  594.0190000  594.0190000  594.0190000  567.0320000  591.0470000  594.0190000  594.0190000  563.9990000  563.9990000  582.0170000  548.9990000 
# peak transmission
#            0.9253390    0.9226380    0.9213460    0.9280420    0.9270820    0.9165700    0.9169100    0.9181430    0.9225040    0.9114190    0.9075210    0.9143250    0.9133820 
# lambda blue with 1/2 of peak transmission
#          501.8522650  501.7397810  501.7354389  502.0038460  502.0066458  501.2819376  501.2475197  501.8293787  501.8201276  501.7589318  501.6962080  501.6833171  501.6739426 
# lambda red  with 1/2 of peak transmission
#          600.7632178  601.1913579  601.0793249  600.3739914  600.5135549  601.0814734  600.8391391  599.5252236  599.8446614  602.1347992  601.8671672  598.9939524  599.4402006 
# half width                              
#           98.9109528   99.4515768   99.3438860   98.3701454   98.5069091   99.7995358   99.5916194   97.6958450   98.0245338  100.3758674  100.1709593   97.3106353   97.7662580 
# central wavelength                      
#          551.3077414  551.4655695  551.4073819  551.1889187  551.2601003  551.1817055  551.0433294  550.6773012  550.8323945  551.9468655  551.7816876  550.3386348  550.5570716 
# central wavelength calculated as SAGEM (mean frequency)
#          546.8713006  546.9817827  546.9328282  546.7999129  546.8594503  546.6641629  546.5434606  546.3442380  546.4713541  547.3833308  547.2354054  546.0370289  546.2168126 
# lambda blue with 80% of peak transmission
#          504.4666335  504.2479709  504.1607126  504.7124248  504.7592260  503.5821315  503.5237988  504.1061465  504.2164940  504.1757790  503.8890398  503.7693731  503.8774711 
# lambda red  with 80% of peak transmission
#          598.1344976  598.5962272  598.4726798  597.8095368  597.9098633  598.5109725  598.2924791  597.2320757  597.4545187  600.1429613  599.6038306  596.5578253  597.1519264 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.8927738    0.8907381    0.8895078    0.8943696    0.8944414    0.8841656    0.8827350    0.8872241    0.8925622    0.8785356    0.8736962    0.8846610    0.8827917 
# ATB calculated from points above 50%
#            0.8768913    0.8771490    0.8755445    0.8764690    0.8768974    0.8750785    0.8726240    0.8822370    0.8873521    0.8737147    0.8682564    0.8787771    0.8827917 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 550.338635 at column = 13, at id = 213 
# maxCWL      = 551.946866 at column = 11, at id = 211 
# difference =    1.6082308 
# minBW       = 97.310635 at column = 13, at id = 213 
# maxBW       = 100.375867 at column = 11, at id = 211 
# difference =    3.0652321 
# minATB80    = 0.873696 at column = 12, at id = 212 
# maxATB80    = 0.894441 at column =  6, at id = 206 
# difference =    0.0207452 
# minBlueEdge = 501.247520 at column =  8, at id = 208 
# maxBlueEdge = 502.006646 at column =  6, at id = 206 
# difference =    0.7591261 
# minRedEdge  = 598.993952 at column = 13, at id = 213 
# maxRedEdge  = 602.134799 at column = 11, at id = 211 
# difference =    3.1408468 
# minABR      = 9.999900 at column =  2, at id = 202 
# maxABR      = 9.999900 at column =  2, at id = 202 
# difference =    0.0000000 
  299.645    -0.000766    -0.000989    -0.001046     0.000012     0.000321     0.001326    -0.000258    -0.000584     0.000419    -0.000562     0.000779     0.000345     0.000553 
  302.654    -0.000131    -0.000238    -0.000181    -0.000097     0.000010     0.000253    -0.000169    -0.000082     0.000213    -0.000151    -0.000113     0.000116     0.000014 
  305.662    -0.000077     0.000008    -0.000079    -0.000062     0.000018     0.000115    -0.000010    -0.000016     0.000082    -0.000040    -0.000044     0.000022    -0.000034 
  308.671    -0.000012    -0.000012    -0.000047     0.000010     0.000013     0.000072    -0.000033    -0.000029     0.000049    -0.000002    -0.000048     0.000067    -0.000024 
  311.679    -0.000003    -0.000017    -0.000058     0.000022    -0.000004     0.000049    -0.000068     0.000005     0.000010     0.000018    -0.000024     0.000059    -0.000004 
  314.687    -0.000002    -0.000025    -0.000052     0.000029    -0.000015     0.000006    -0.000016    -0.000013     0.000048     0.000026     0.000008    -0.000001    -0.000003 
  317.694    -0.000002    -0.000016    -0.000015     0.000024    -0.000031     0.000033    -0.000031    -0.000001     0.000040    -0.000006     0.000033     0.000013    -0.000007 
  320.702    -0.000016    -0.000017    -0.000013    -0.000003     0.000005     0.000031    -0.000019    -0.000001     0.000022    -0.000009     0.000021     0.000018     0.000002 
  323.709    -0.000017    -0.000038    -0.000024     0.000014     0.000005     0.000027    -0.000006    -0.000011     0.000015    -0.000001     0.000021    -0.000007    -0.000002 
  326.716    -0.000007    -0.000018    -0.000024    -0.000011     0.000010     0.000029    -0.000005    -0.000001     0.000016     0.000007     0.000007    -0.000001    -0.000014 
  329.665    -0.000013    -0.000021    -0.000015     0.000003     0.000013     0.000022     0.000001    -0.000003     0.000018     0.000002     0.000018     0.000011    -0.000014 
  332.672    -0.000007    -0.000016    -0.000016    -0.000002    -0.000006     0.000018    -0.000015    -0.000005     0.000012     0.000004     0.000009    -0.000019    -0.000006 
  335.678    -0.000010     0.000003    -0.000006     0.000010     0.000005     0.000006    -0.000021    -0.000001     0.000007    -0.000004     0.000006    -0.000010    -0.000005 
  338.683    -0.000009    -0.000009    -0.000004    -0.000001     0.000004     0.000009    -0.000013     0.000003     0.000006     0.000001     0.000004    -0.000004    -0.000013 
  341.689    -0.000002    -0.000002    -0.000011    -0.000004    -0.000004     0.000013    -0.000007    -0.000003     0.000001    -0.000000     0.000009    -0.000005    -0.000001 
  344.694    -0.000006    -0.000006    -0.000007    -0.000005    -0.000005     0.000017    -0.000006     0.000004     0.000003    -0.000003     0.000006    -0.000000    -0.000005 
  347.699    -0.000004    -0.000006    -0.000006     0.000000    -0.000001     0.000017    -0.000006    -0.000000    -0.000001     0.000002     0.000003     0.000002    -0.000004 
  350.703    -0.000004    -0.000005    -0.000011     0.000001    -0.000002     0.000007     0.000057    -0.000001     0.000003    -0.000002     0.000005     0.000006    -0.000007 
  353.707     0.000001    -0.000003    -0.000004    -0.000003     0.000002     0.000006     0.000001    -0.000002     0.000003     0.000004     0.000000     0.000004    -0.000006 
  356.711    -0.000000    -0.000009     0.000001     0.000001     0.000002     0.000007    -0.000002    -0.000006     0.000000     0.000005     0.000000    -0.000005     0.000001 
  359.715    -0.000000    -0.000004     0.000001    -0.000001     0.000001     0.000006     0.000003    -0.000003     0.000005     0.000004     0.000004    -0.000002     0.000000 
  362.718     0.000000    -0.000000    -0.000002     0.000005    -0.000003     0.000008    -0.000005     0.000001     0.000003    -0.000000    -0.000002    -0.000003    -0.000004 
  365.721    -0.000002    -0.000002    -0.000004     0.000000     0.000000     0.000011    -0.000004     0.000003     0.000003    -0.000004     0.000000     0.000003    -0.000003 
  368.724    -0.000002     0.000000    -0.000003     0.000000     0.000000     0.000006     0.000000     0.000001     0.000003    -0.000003     0.000001     0.000002    -0.000003 
  371.726    -0.000002     0.000001    -0.000001    -0.000002    -0.000000     0.000007     0.000001    -0.000001     0.000001    -0.000001     0.000001     0.000004     0.000003 
  374.728    -0.000001     0.000001     0.000000    -0.000000     0.000001     0.000006    -0.000001    -0.000001     0.000003    -0.000001     0.000003     0.000001     0.000002 
  377.730    -0.000001     0.000001    -0.000000    -0.000001     0.000001     0.000007    -0.000001    -0.000004     0.000002     0.000002     0.000002     0.000000    -0.000000 
  380.788    -0.000000     0.000001    -0.000002     0.000000     0.000001     0.000005     0.000001     0.000001     0.000004     0.000003     0.000003     0.000002    -0.000000 
  383.789    -0.000001    -0.000001    -0.000001     0.000001    -0.000001     0.000005     0.000001    -0.000002     0.000001     0.000002     0.000000     0.000002    -0.000000 
  386.789     0.000001     0.000001     0.000002     0.000000    -0.000002     0.000005    -0.000002    -0.000001     0.000001     0.000000    -0.000001     0.000001    -0.000000 
  389.790    -0.000002    -0.000001     0.000002     0.000001     0.000001     0.000008    -0.000002    -0.000001     0.000001     0.000002    -0.000002     0.000002    -0.000000 
  392.790    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000006    -0.000002     0.000001     0.000002     0.000004     0.000001     0.000002    -0.000001 
  395.790     0.000000     0.000001     0.000001    -0.000000     0.000004     0.000005    -0.000001    -0.000000     0.000001     0.000002     0.000001     0.000002    -0.000000 
  398.789     0.000001    -0.000000     0.000001     0.000001     0.000002     0.000004    -0.000002    -0.000002     0.000001     0.000001    -0.000001     0.000002     0.000000 
  401.788     0.000001     0.000001     0.000000    -0.000001     0.000001     0.000005     0.000000    -0.000001     0.000002    -0.000000    -0.000000    -0.000000    -0.000002 
  404.787    -0.000000     0.000001    -0.000000    -0.000000     0.000001     0.000004     0.000001    -0.000001     0.000002     0.000000     0.000002     0.000001    -0.000000 
  407.785    -0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000003    -0.000001    -0.000000     0.000002     0.000002     0.000001     0.000001     0.000000 
  410.783     0.000001    -0.000001     0.000001     0.000000     0.000001     0.000004    -0.000001     0.000001     0.000001     0.000000    -0.000000     0.000001    -0.000001 
  413.781     0.000002    -0.000001     0.000000     0.000001    -0.000000     0.000003    -0.000003    -0.000001     0.000000     0.000001     0.000001    -0.000000     0.000000 
  416.834     0.000001    -0.000000    -0.000000     0.000002     0.000001     0.000003    -0.000002    -0.000001    -0.000000    -0.000000     0.000001     0.000000     0.000000 
  419.831     0.000000     0.000001    -0.000001     0.000001     0.000001     0.000003    -0.000001    -0.000001     0.000000    -0.000000     0.000001     0.000001     0.000001 
  422.828    -0.000000     0.000001     0.000001     0.000001    -0.000000     0.000003    -0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000001     0.000002 
  425.824     0.000002     0.000001     0.000000    -0.000001    -0.000001     0.000002    -0.000001     0.000000     0.000001     0.000002     0.000001     0.000000     0.000000 
  428.820     0.000000     0.000000     0.000001     0.000001     0.000001     0.000002     0.000001     0.000000     0.000000     0.000002     0.000000     0.000000    -0.000000 
  431.815     0.000001    -0.000000     0.000001     0.000001     0.000002     0.000002     0.000001     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000000 
  434.810     0.000000     0.000000     0.000000     0.000002     0.000000     0.000002     0.000000    -0.000001     0.000001     0.000000     0.000001     0.000001     0.000000 
  437.862     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000002    -0.000000    -0.000001     0.000001     0.000000     0.000001     0.000001     0.000000 
  440.856     0.000002    -0.000001     0.000000     0.000001    -0.000001     0.000002    -0.000000    -0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000 
  443.850     0.000001     0.000000     0.000000     0.000001     0.000001     0.000002     0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000001     0.000000 
  446.844     0.000001    -0.000001     0.000001     0.000001     0.000001     0.000002     0.000001    -0.000000     0.000000    -0.000000     0.000001     0.000001     0.000001 
  449.837     0.000001     0.000000     0.000002     0.000001     0.000001     0.000002     0.000000     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001 
  452.830     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000002     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000 
  455.878     0.000001     0.000001     0.000001     0.000002     0.000001     0.000002     0.000000     0.000001     0.000001     0.000001     0.000003     0.000002     0.000001 
  458.870     0.000003     0.000001     0.000002     0.000003     0.000002     0.000004     0.000002     0.000002     0.000002     0.000003     0.000004     0.000002     0.000002 
  461.862     0.000003     0.000002     0.000002     0.000002     0.000002     0.000004     0.000002     0.000002     0.000002     0.000003     0.000003     0.000002     0.000002 
  464.853     0.000010     0.000016     0.000009     0.000009     0.000010     0.000005     0.000010     0.000010     0.000003     0.000003     0.000017     0.000010     0.000003 
  467.901     0.000021     0.000024     0.000021     0.000015     0.000022     0.000026     0.000024     0.000020     0.000025     0.000027     0.000028     0.000018     0.000021 
  470.891     0.000018     0.000020     0.000018     0.000018     0.000015     0.000027     0.000023     0.000017     0.000017     0.000027     0.000028     0.000017     0.000018 
  473.881     0.000039     0.000043     0.000031     0.000033     0.000038     0.000043     0.000038     0.000035     0.000038     0.000043     0.000041     0.000031     0.000040 
  476.871     0.000086     0.000095     0.000092     0.000079     0.000082     0.000117     0.000112     0.000085     0.000091     0.000093     0.000098     0.000087     0.000091 
  479.916     0.000137     0.000150     0.000147     0.000125     0.000131     0.000172     0.000167     0.000121     0.000131     0.000165     0.000162     0.000115     0.000130 
  482.905     0.000268     0.000288     0.000282     0.000247     0.000254     0.000320     0.000305     0.000240     0.000259     0.000311     0.000301     0.000239     0.000262 
  485.894     0.000592     0.000642     0.000657     0.000536     0.000530     0.000894     0.000927     0.000613     0.000603     0.000644     0.000687     0.000696     0.000676 
  488.882     0.002285     0.002424     0.002410     0.002143     0.002192     0.002984     0.003007     0.002181     0.002298     0.002390     0.002449     0.002238     0.002372 
  491.925     0.005754     0.006063     0.005934     0.005398     0.005543     0.006706     0.006618     0.005377     0.005743     0.005957     0.005778     0.005415     0.005890 
  494.913     0.026688     0.028021     0.028464     0.024249     0.024081     0.038068     0.039373     0.028261     0.028095     0.025585     0.027351     0.031940     0.031158 
  497.899     0.144540     0.152962     0.154203     0.131733     0.131467     0.192557     0.193558     0.140540     0.142522     0.148877     0.154281     0.146841     0.150047 
  500.942     0.352525     0.365651     0.364339     0.333351     0.334849     0.417648     0.421535     0.345901     0.351429     0.356739     0.360120     0.359686     0.365672 
  503.928     0.713839     0.723725     0.726879     0.700806     0.695790     0.774602     0.782373     0.726716     0.724873     0.718490     0.730854     0.752318     0.736989 
  506.913     0.860321     0.857926     0.857686     0.859213     0.860533     0.858775     0.856830     0.857385     0.860729     0.846733     0.844101     0.858100     0.861582 
  509.954     0.861002     0.858103     0.857694     0.861186     0.863833     0.851787     0.847299     0.853020     0.858822     0.850512     0.845697     0.847986     0.854138 
  512.939     0.839978     0.835609     0.834442     0.841551     0.844988     0.832657     0.828729     0.837547     0.845393     0.825885     0.821396     0.834246     0.844841 
  515.923     0.867209     0.863948     0.865642     0.868028     0.867817     0.869047     0.866987     0.867657     0.871285     0.858830     0.857220     0.868753     0.868442 
  518.963     0.891252     0.885215     0.886065     0.895102     0.894485     0.883096     0.882189     0.891890     0.894760     0.872459     0.871349     0.891897     0.891016 
  521.946     0.895245     0.891963     0.892574     0.897876     0.896855     0.890428     0.889550     0.891640     0.894834     0.884794     0.883269     0.889626     0.887732 
  524.929     0.896603     0.892600     0.892904     0.900628     0.899240     0.887647     0.886833     0.894587     0.898427     0.882942     0.879838     0.893272     0.894437 
  527.967     0.888567     0.886093     0.885368     0.891747     0.890636     0.884775     0.883870     0.885022     0.889465     0.878168     0.875250     0.883545     0.886507 
  530.949     0.896874     0.893876     0.892850     0.900602     0.900375     0.889092     0.887146     0.896765     0.900804     0.883641     0.878900     0.895208     0.898303 
  533.987     0.893870     0.890026     0.888717     0.897759     0.897873     0.886590     0.884468     0.894216     0.898343     0.878617     0.873756     0.893375     0.899199 
  536.968     0.889328     0.882583     0.880406     0.895215     0.895786     0.870918     0.867211     0.891165     0.896989     0.866766     0.858433     0.889676     0.897057 
  539.948     0.880835     0.875542     0.874406     0.885811     0.885783     0.873693     0.872955     0.884498     0.889567     0.867270     0.863331     0.883334     0.886128 
  542.984     0.897408     0.894917     0.894918     0.899304     0.897735     0.894969     0.895561     0.896835     0.900455     0.890335     0.886991     0.895170     0.894222 
  545.964     0.913237     0.908714     0.908589     0.915183     0.913503     0.903741     0.903760     0.911407     0.914305     0.899600     0.894942     0.909625     0.912019 
  548.999     0.913322     0.908832     0.909068     0.915136     0.915275     0.903717     0.904412     0.910504     0.914508     0.898855     0.893738     0.908245     0.913382 
  551.977     0.906686     0.902183     0.902021     0.909630     0.909375     0.894587     0.892825     0.901820     0.907536     0.891460     0.884198     0.897900     0.907107 
  555.012     0.896619     0.893091     0.893619     0.899335     0.899508     0.889793     0.889397     0.893588     0.899152     0.882874     0.877550     0.891798     0.898705 
  557.989     0.888328     0.884231     0.882492     0.892258     0.893808     0.877408     0.876085     0.882415     0.890962     0.876532     0.869760     0.876670     0.886404 
  561.023     0.888226     0.890275     0.890189     0.886843     0.887315     0.899292     0.901160     0.881251     0.886796     0.889868     0.889390     0.879782     0.880585 
  563.999     0.915662     0.916667     0.915630     0.913978     0.913958     0.916371     0.915536     0.905553     0.909631     0.911419     0.907521     0.901569     0.904790 
  567.032     0.918401     0.918021     0.915706     0.918126     0.917987     0.916570     0.915568     0.910147     0.914023     0.910918     0.906713     0.906969     0.910593 
  570.007     0.917026     0.915851     0.912864     0.918830     0.918422     0.907754     0.903027     0.910497     0.914990     0.903264     0.895535     0.907137     0.911177 
  573.038     0.881102     0.877955     0.872854     0.884595     0.887078     0.867643     0.861694     0.874618     0.883516     0.866108     0.855493     0.870763     0.883667 
  576.013     0.876742     0.876809     0.874436     0.878670     0.878723     0.881234     0.880406     0.877831     0.883265     0.871841     0.867986     0.877953     0.880440 
  579.043     0.903426     0.902933     0.900471     0.905000     0.902299     0.904152     0.903201     0.901011     0.903495     0.901198     0.896776     0.897638     0.895046 
  582.017     0.915273     0.911370     0.908769     0.920598     0.918622     0.901893     0.898976     0.917731     0.920506     0.900927     0.893330     0.914325     0.913361 
  585.046     0.903118     0.895637     0.892575     0.910689     0.909831     0.886858     0.885504     0.907081     0.911097     0.881427     0.875843     0.902521     0.900933 
  588.019     0.892993     0.892580     0.890658     0.896294     0.895479     0.892486     0.892504     0.890827     0.895889     0.886104     0.881453     0.887583     0.888296 
  591.047     0.914800     0.914743     0.914128     0.914367     0.912233     0.916137     0.916910     0.911584     0.913090     0.908307     0.904305     0.910537     0.910137 
  594.019     0.925339     0.922638     0.921346     0.928042     0.927082     0.914044     0.912995     0.918143     0.922504     0.906258     0.900007     0.906233     0.909069 
  597.046     0.847588     0.872108     0.865831     0.824522     0.831845     0.870825     0.860883     0.756865     0.785305     0.901259     0.892122     0.697854     0.743390 
  600.073     0.549151     0.610462     0.592652     0.499087     0.515854     0.586573     0.551609     0.393275     0.434813     0.738739     0.695549     0.323834     0.380915 
  603.043     0.177022     0.214386     0.203138     0.153077     0.163186     0.208759     0.190490     0.108501     0.126523     0.331038     0.295301     0.084493     0.108911 
  606.068     0.055173     0.069637     0.065658     0.046209     0.049130     0.070137     0.062603     0.033521     0.039195     0.118230     0.102964     0.026719     0.033427 
  609.038     0.016184     0.019863     0.018606     0.013835     0.014903     0.019335     0.017241     0.010044     0.011874     0.032700     0.028178     0.008019     0.010412 
  612.062     0.005388     0.006594     0.006184     0.004614     0.004930     0.006485     0.005763     0.003424     0.004025     0.010832     0.009285     0.002744     0.003490 
  615.086     0.001763     0.002142     0.002015     0.001506     0.001609     0.002174     0.001986     0.001120     0.001309     0.003460     0.003024     0.000924     0.001181 
  618.053     0.000781     0.000948     0.000891     0.000673     0.000710     0.000941     0.000847     0.000512     0.000598     0.001505     0.001300     0.000426     0.000533 
  621.076     0.000253     0.000294     0.000274     0.000229     0.000247     0.000269     0.000240     0.000167     0.000199     0.000427     0.000362     0.000134     0.000182 
  624.099     0.000084     0.000106     0.000099     0.000077     0.000082     0.000110     0.000098     0.000054     0.000067     0.000158     0.000139     0.000047     0.000057 
  627.064     0.000047     0.000053     0.000052     0.000042     0.000044     0.000054     0.000050     0.000031     0.000040     0.000074     0.000066     0.000029     0.000039 
  630.086     0.000023     0.000023     0.000023     0.000021     0.000023     0.000026     0.000023     0.000019     0.000020     0.000030     0.000030     0.000016     0.000022 
  633.106     0.000017     0.000020     0.000019     0.000018     0.000017     0.000021     0.000021     0.000016     0.000014     0.000025     0.000025     0.000013     0.000017 
  636.071     0.000034     0.000039     0.000038     0.000027     0.000030     0.000048     0.000051     0.000032     0.000030     0.000049     0.000049     0.000031     0.000033 
  639.090     0.000042     0.000049     0.000047     0.000036     0.000038     0.000048     0.000046     0.000022     0.000035     0.000069     0.000061     0.000018     0.000026 
  642.109     0.000003     0.000009     0.000012     0.000010     0.000003     0.000011     0.000007     0.000002     0.000006     0.000018     0.000016     0.000001    -0.000000 
  645.128     0.000003     0.000000     0.000000    -0.000000     0.000003    -0.000001     0.000003     0.000002     0.000000     0.000001     0.000001     0.000001     0.000002 
  648.090     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000001 
  651.107    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000001     0.000001 
  654.123    -0.000000     0.000001     0.000000     0.000001     0.000001    -0.000000    -0.000000     0.000001     0.000000     0.000000     0.000001    -0.000001     0.000001 
  657.139     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001     0.000000    -0.000001     0.000000     0.000001    -0.000001     0.000001 
  660.099     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000001    -0.000000     0.000001    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  663.114     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000001     0.000001    -0.000000    -0.000000     0.000000    -0.000000    -0.000000 
  666.129     0.000001    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000001    -0.000000     0.000000    -0.000000     0.000000 
  669.142     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000001     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000 
  672.155     0.000000     0.000000    -0.000001    -0.000000     0.000001    -0.000000    -0.000001     0.000000    -0.000000    -0.000001     0.000000    -0.000001     0.000000 
  675.168     0.000000     0.000000    -0.000001    -0.000000     0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000000     0.000001    -0.000001     0.000000 
  678.124     0.000001    -0.000000    -0.000001    -0.000000     0.000000     0.000000    -0.000001     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001 
  681.136     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000000    -0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001 
  684.146     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000 
  687.157     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000000     0.000000 
  690.166     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000 
  693.175     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  696.183     0.000001    -0.000000    -0.000000    -0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  699.191     0.000000     0.000000    -0.000000    -0.000001     0.000001    -0.000000    -0.000001     0.000001     0.000001    -0.000000     0.000000    -0.000000     0.000000 
  702.198     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000001     0.000000     0.000001    -0.000001    -0.000000    -0.000001     0.000000 
  705.205     0.000001    -0.000000    -0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000 
  708.211     0.000001    -0.000001    -0.000001    -0.000001    -0.000000     0.000001    -0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000    -0.000000 
  711.216     0.000000     0.000000     0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000000 
  714.220     0.000001    -0.000001    -0.000001    -0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000001    -0.000000 
  717.224     0.000001     0.000000    -0.000001    -0.000000     0.000001    -0.000001     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001 
  720.228     0.000000    -0.000000    -0.000001    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001 
  723.230     0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000001 
  726.232     0.000000    -0.000000    -0.000001    -0.000001     0.000001     0.000002    -0.000001     0.000001    -0.000000    -0.000000     0.000001     0.000000     0.000002 
  729.234    -0.000000    -0.000001    -0.000001    -0.000001     0.000002     0.000001     0.000001     0.000000     0.000001    -0.000000    -0.000001     0.000000     0.000001 
  732.234    -0.000000    -0.000000    -0.000001    -0.000001     0.000000     0.000001    -0.000000     0.000000     0.000001    -0.000001     0.000000     0.000001     0.000000 
  735.235    -0.000000    -0.000000    -0.000000    -0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000 
  738.234     0.000001     0.000000    -0.000001    -0.000001     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001    -0.000000 
  741.233    -0.000001    -0.000001    -0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000001     0.000000 
  744.231    -0.000000    -0.000001    -0.000001    -0.000001     0.000001     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000001    -0.000000    -0.000000 
  747.228    -0.000000    -0.000001    -0.000001    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000001    -0.000000 
  750.225    -0.000000    -0.000001    -0.000000    -0.000001     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000 
  753.221    -0.000001    -0.000001    -0.000001    -0.000000     0.000000     0.000001    -0.000000     0.000001    -0.000002     0.000000     0.000001     0.000001     0.000001 
  756.272    -0.000000     0.000001    -0.000001    -0.000002     0.000001     0.000001    -0.000001    -0.000000    -0.000000    -0.000000    -0.000001     0.000001     0.000001 
  759.267    -0.000001    -0.000000    -0.000001    -0.000001     0.000001     0.000001     0.000001    -0.000001     0.000001    -0.000000    -0.000000     0.000001     0.000001 
  762.261    -0.000000    -0.000000    -0.000002     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000 
  765.254    -0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000001 
  768.247    -0.000000    -0.000001    -0.000001    -0.000000     0.000001     0.000001    -0.000001    -0.000001     0.000001    -0.000001     0.000000    -0.000000     0.000000 
  771.294    -0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000001    -0.000001     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001 
  774.286    -0.000001     0.000000    -0.000001    -0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000002    -0.000000    -0.000000     0.000001 
  777.277    -0.000000    -0.000001     0.000001    -0.000001     0.000001     0.000001    -0.000001     0.000001    -0.000001     0.000000     0.000000     0.000001     0.000001 
  780.266    -0.000001    -0.000002    -0.000001    -0.000001     0.000002     0.000003    -0.000000     0.000001     0.000000     0.000000    -0.000002     0.000001    -0.000000 
  783.311     0.000001     0.000000    -0.000002    -0.000001     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000001    -0.000001    -0.000000     0.000001 
  786.300     0.000000    -0.000000    -0.000000    -0.000002    -0.000000     0.000001    -0.000001    -0.000000     0.000001     0.000001    -0.000001    -0.000000     0.000001 
  789.288     0.000000    -0.000001    -0.000001    -0.000002     0.000001     0.000000    -0.000001     0.000001     0.000001     0.000001    -0.000002    -0.000001     0.000003 
  792.275     0.000001    -0.000000    -0.000000    -0.000001     0.000000     0.000001    -0.000001     0.000001     0.000000    -0.000000    -0.000002     0.000000     0.000002 
  795.316    -0.000001    -0.000000    -0.000001    -0.000001    -0.000000     0.000001    -0.000002     0.000000     0.000001    -0.000000    -0.000002     0.000000     0.000002 
  798.302    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000001    -0.000002     0.000001     0.000001     0.000001    -0.000001     0.000000     0.000001 
  801.287     0.000001    -0.000000    -0.000001    -0.000001     0.000000     0.000000    -0.000002     0.000001     0.000000    -0.000000    -0.000001     0.000000    -0.000000 
  804.327     0.000001     0.000001    -0.000000    -0.000000     0.000000     0.000001    -0.000001     0.000001     0.000001     0.000001    -0.000000    -0.000000     0.000001 
  807.310    -0.000000     0.000000    -0.000001    -0.000000     0.000001     0.000002    -0.000001     0.000002    -0.000000    -0.000000    -0.000001     0.000000     0.000000 
  810.348     0.000000    -0.000000     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000003     0.000011    -0.000000    -0.000002    -0.000000     0.000001 
  813.331     0.000001     0.000001    -0.000001     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000001    -0.000000    -0.000002     0.000000     0.000001 
  816.312     0.000000     0.000001     0.000002     0.000001     0.000002     0.000025     0.000026     0.000002     0.000000     0.000023     0.000025     0.000001     0.000013 
  819.348     0.000003     0.000015     0.000015     0.000004     0.000004     0.000071     0.000102     0.000003     0.000002     0.000053     0.000100     0.000003     0.000024 
  822.328     0.000143     0.000253     0.000262     0.000050     0.000049     0.000380     0.000312     0.000063     0.000048     0.000442     0.000335     0.000075     0.000059 
  825.362     0.000200     0.000144     0.000124     0.000242     0.000278     0.000004    -0.000001     0.000204     0.000256     0.000029     0.000002     0.000154     0.000229 
  828.341     0.000000     0.000003     0.000002     0.000000     0.000002     0.000004     0.000001     0.000003     0.000003     0.000000     0.000001     0.000003     0.000003 
  831.374    -0.000001     0.000001    -0.000001     0.000001     0.000001     0.000002    -0.000000     0.000001     0.000001    -0.000001    -0.000001     0.000000     0.000001 
  834.351     0.000000     0.000001    -0.000000    -0.000000    -0.000001     0.000002    -0.000001     0.000001     0.000001    -0.000000    -0.000001    -0.000000     0.000000 
  837.382    -0.000001     0.000001    -0.000001    -0.000000    -0.000000     0.000002    -0.000002     0.000001     0.000000    -0.000001    -0.000001    -0.000000     0.000001 
  840.357    -0.000002     0.000001    -0.000000    -0.000002    -0.000001     0.000002    -0.000002     0.000002     0.000001     0.000000    -0.000000    -0.000001    -0.000000 
  843.387    -0.000001    -0.000000    -0.000000    -0.000002    -0.000000     0.000002    -0.000002     0.000002     0.000000    -0.000000    -0.000001    -0.000001    -0.000000 
  846.361    -0.000001     0.000000    -0.000000    -0.000002     0.000001     0.000001    -0.000002     0.000000    -0.000000    -0.000001    -0.000001     0.000002     0.000001 
  849.389    -0.000002     0.000000    -0.000001    -0.000000     0.000002     0.000001    -0.000000     0.000001    -0.000001    -0.000000    -0.000002    -0.000000     0.000001 
  852.362     0.000000     0.000001     0.000000    -0.000001     0.000000     0.000002    -0.000001     0.000001     0.000001    -0.000001    -0.000001     0.000000     0.000001 
  855.389    -0.000001     0.000001    -0.000001    -0.000001    -0.000000     0.000002    -0.000000     0.000001     0.000000    -0.000002    -0.000002    -0.000001     0.000001 
  858.359    -0.000001     0.000001    -0.000001    -0.000001     0.000001     0.000003    -0.000002    -0.000001     0.000000    -0.000001    -0.000002    -0.000001     0.000001 
  861.385    -0.000000     0.000002    -0.000001    -0.000001     0.000001     0.000001    -0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001 
  864.409     0.000001     0.000002     0.000000    -0.000000     0.000004     0.000003    -0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000002 
  867.378     0.000001     0.000001    -0.000000    -0.000000     0.000003     0.000001    -0.000001     0.000001     0.000002    -0.000001    -0.000000     0.000001     0.000003 
  870.400    -0.000000     0.000001    -0.000001    -0.000002     0.000001     0.000002    -0.000001     0.000000     0.000002    -0.000002     0.000001    -0.000000     0.000002 
  873.422    -0.000001     0.000001    -0.000002    -0.000001     0.000001     0.000001    -0.000001    -0.000001     0.000002    -0.000000     0.000000    -0.000002     0.000002 
  876.389     0.000000     0.000000    -0.000002    -0.000001     0.000001     0.000001    -0.000001     0.000001     0.000002    -0.000000    -0.000000    -0.000001     0.000001 
  879.409    -0.000001    -0.000000    -0.000001    -0.000001     0.000001     0.000002    -0.000001     0.000000     0.000000     0.000001     0.000002    -0.000001     0.000001 
  882.428    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000002     0.000000    -0.000001     0.000001    -0.000000    -0.000000    -0.000001     0.000002 
  885.447    -0.000000     0.000000    -0.000002    -0.000001     0.000001     0.000001    -0.000002     0.000001     0.000002    -0.000001    -0.000001     0.000000     0.000001 
  888.410    -0.000000    -0.000000    -0.000002    -0.000001     0.000000     0.000001    -0.000001     0.000001     0.000002    -0.000001    -0.000000    -0.000001     0.000001 
  891.427     0.000000    -0.000000    -0.000001    -0.000001     0.000002     0.000002    -0.000001     0.000001     0.000002     0.000001    -0.000000     0.000000     0.000001 
  894.444    -0.000001     0.000000    -0.000001    -0.000001     0.000001     0.000003    -0.000001     0.000000     0.000002     0.000001     0.000000     0.000001     0.000001 
  897.459     0.000001     0.000001     0.000001     0.000000     0.000000     0.000002     0.000000     0.000002     0.000002     0.000001     0.000001     0.000001     0.000002 
  900.419     0.000002     0.000003     0.000000     0.000001     0.000002     0.000004     0.000002     0.000001     0.000002     0.000003     0.000003     0.000001     0.000004 
  903.433     0.000002     0.000004     0.000002     0.000001     0.000003     0.000004     0.000002     0.000001     0.000003     0.000003     0.000002     0.000001     0.000002 
  906.446     0.000002     0.000002     0.000001     0.000001     0.000003     0.000002    -0.000000     0.000002     0.000002     0.000001     0.000001     0.000001     0.000002 
  909.458     0.000000     0.000001     0.000000    -0.000001     0.000002     0.000001    -0.000001     0.000001     0.000002     0.000001     0.000000    -0.000000     0.000001 
  912.469     0.000000     0.000001    -0.000001    -0.000000     0.000001     0.000001    -0.000001     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000 
  915.480    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000001     0.000000     0.000001    -0.000001    -0.000000     0.000000     0.000001 
  918.489     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000001    -0.000000     0.000000     0.000000    -0.000001     0.000000    -0.000000 
  921.443     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000001     0.000000 
  924.451    -0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001    -0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001 
  927.458     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000 
  930.465     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001 
  933.470     0.000000     0.000001     0.000001     0.000001     0.000001     0.000007     0.000006     0.000001     0.000001     0.000007     0.000006     0.000001     0.000001 
  936.475     0.000002     0.000003     0.000002     0.000002     0.000002     0.000015     0.000016     0.000001     0.000002     0.000015     0.000013     0.000002     0.000002 
  939.478     0.000011     0.000021     0.000021     0.000002     0.000004     0.000022     0.000020     0.000003     0.000002     0.000017     0.000013     0.000004     0.000004 
  942.481     0.000013     0.000013     0.000003     0.000004     0.000006     0.000014     0.000009     0.000013     0.000013     0.000010     0.000009     0.000014     0.000018 
  945.483     0.000003     0.000004     0.000004     0.000005     0.000006     0.000004     0.000010     0.000005     0.000004     0.000003     0.000002     0.000004     0.000020 
  948.484     0.000004     0.000005     0.000003     0.000005     0.000005     0.000016     0.000011     0.000004     0.000004     0.000012     0.000010     0.000004     0.000008 
  951.484     0.000018     0.000020     0.000021     0.000011     0.000005     0.000027     0.000028     0.000011     0.000012     0.000026     0.000025     0.000010     0.000012 
  954.538     0.000033     0.000047     0.000047     0.000022     0.000025     0.000080     0.000077     0.000027     0.000030     0.000080     0.000078     0.000028     0.000029 
  957.537     0.000094     0.000115     0.000113     0.000071     0.000069     0.000170     0.000166     0.000076     0.000087     0.000175     0.000172     0.000068     0.000072 
  960.534     0.000170     0.000201     0.000195     0.000138     0.000146     0.000238     0.000222     0.000126     0.000137     0.000247     0.000233     0.000108     0.000126 
  963.531     0.000181     0.000205     0.000198     0.000157     0.000166     0.000211     0.000191     0.000121     0.000145     0.000222     0.000192     0.000121     0.000151 
  966.526     0.000127     0.000146     0.000142     0.000118     0.000124     0.000148     0.000133     0.000095     0.000109     0.000150     0.000128     0.000104     0.000129 
  969.521     0.000092     0.000105     0.000101     0.000081     0.000085     0.000116     0.000105     0.000069     0.000076     0.000113     0.000099     0.000078     0.000100 
  972.515     0.000082     0.000100     0.000094     0.000072     0.000075     0.000128     0.000117     0.000060     0.000068     0.000124     0.000113     0.000070     0.000088 
  975.563     0.000113     0.000139     0.000135     0.000091     0.000095     0.000182     0.000168     0.000083     0.000093     0.000193     0.000172     0.000088     0.000107 
  978.555     0.000186     0.000215     0.000205     0.000153     0.000160     0.000249     0.000228     0.000146     0.000165     0.000301     0.000271     0.000126     0.000161 
  981.546     0.000278     0.000302     0.000288     0.000244     0.000256     0.000323     0.000301     0.000236     0.000266     0.000380     0.000338     0.000165     0.000206 
  984.537     0.000292     0.000295     0.000276     0.000284     0.000303     0.000256     0.000222     0.000255     0.000302     0.000221     0.000181     0.000219     0.000264 
  987.580     0.000138     0.000128     0.000118     0.000158     0.000171     0.000094     0.000078     0.000129     0.000162     0.000066     0.000048     0.000209     0.000274 
  990.569     0.000040     0.000038     0.000033     0.000050     0.000051     0.000035     0.000029     0.000038     0.000052     0.000023     0.000019     0.000097     0.000140 
  993.556     0.000015     0.000017     0.000015     0.000017     0.000019     0.000017     0.000017     0.000015     0.000025     0.000014     0.000007     0.000032     0.000047 
  996.543     0.000011     0.000008     0.000002     0.000007     0.000013     0.000009     0.000003     0.000012     0.000015     0.000011     0.000002     0.000017     0.000027 
  999.583     0.000000     0.000001     0.000007     0.000002     0.000001     0.000008     0.000003     0.000006     0.000002     0.000001     0.000002     0.000008     0.000016 
 1002.568     0.000003     0.000002     0.000001     0.000002     0.000003     0.000005     0.000003     0.000001     0.000005     0.000003     0.000006     0.000010     0.000013 
 1005.552     0.000003     0.000003     0.000002     0.000002     0.000003     0.000013     0.000004     0.000002     0.000003     0.000003     0.000004     0.000010     0.000015 
 1008.589     0.000003     0.000004     0.000004     0.000002     0.000002     0.000018     0.000011     0.000002     0.000003     0.000017     0.000015     0.000013     0.000019 
 1011.571     0.000010     0.000012     0.000016     0.000009     0.000010     0.000021     0.000018     0.000016     0.000018     0.000018     0.000015     0.000022     0.000034 
 1014.606     0.000014     0.000018     0.000018     0.000017     0.000019     0.000023     0.000019     0.000018     0.000021     0.000026     0.000023     0.000027     0.000049 
 1017.587     0.000017     0.000018     0.000016     0.000017     0.000023     0.000027     0.000020     0.000019     0.000022     0.000028     0.000021     0.000030     0.000059 
 1020.620     0.000018     0.000019     0.000019     0.000017     0.000019     0.000020     0.000020     0.000017     0.000022     0.000022     0.000020     0.000033     0.000053 
 1023.598     0.000016     0.000020     0.000016     0.000018     0.000021     0.000020     0.000017     0.000015     0.000020     0.000018     0.000017     0.000031     0.000047 
 1026.629     0.000013     0.000016     0.000014     0.000010     0.000018     0.000004     0.000001     0.000015     0.000016     0.000004     0.000020     0.000023     0.000030 
 1029.606     0.000005     0.000012     0.000000     0.000003     0.000007     0.000007     0.000002     0.000008     0.000001     0.000010     0.000023     0.000022     0.000022 
 1032.635     0.000004     0.000003     0.000005     0.000005     0.000004     0.000005     0.000004     0.000000     0.000009     0.000015     0.000020     0.000026     0.000021 
 1035.610     0.000003     0.000003     0.000004     0.000004     0.000002     0.000004     0.000004     0.000003     0.000003     0.000014     0.000024     0.000023     0.000019 
 1038.637     0.000003     0.000003     0.000004     0.000003     0.000003     0.000004     0.000003     0.000003     0.000004     0.000009     0.000024     0.000022     0.000009 
 1041.610     0.000003     0.000003     0.000002     0.000004     0.000003     0.000003     0.000003     0.000004     0.000004     0.000011     0.000030     0.000021     0.000006 
 1044.635     0.000003     0.000003     0.000004     0.000004     0.000003     0.000004     0.000003     0.000003     0.000004     0.000004     0.000028     0.000025     0.000005 
 1047.660     0.000003     0.000004     0.000003     0.000004     0.000004     0.000004     0.000004     0.000004     0.000005     0.000006     0.000026     0.000024     0.000018 
 1050.629     0.000005     0.000003     0.000002     0.000005     0.000004     0.000004     0.000005     0.000005     0.000005     0.000005     0.000029     0.000020     0.000006 
 1053.652     0.000003     0.000003     0.000004     0.000005     0.000004     0.000004     0.000004     0.000005     0.000005     0.000004     0.000027     0.000001     0.000007 
 1056.620     0.000003     0.000001     0.000003     0.000003     0.000003     0.000004     0.000002     0.000004     0.000005     0.000004     0.000024     0.000006     0.000008 
 1059.640     0.000003     0.000003     0.000002     0.000004     0.000003     0.000004     0.000002     0.000003     0.000003     0.000004     0.000002     0.000006     0.000006 
 1062.660     0.000000     0.000003     0.000003     0.000005     0.000003     0.000004     0.000001     0.000004     0.000002     0.000004     0.000006     0.000006     0.000005 
 1065.678     0.000002     0.000001     0.000004     0.000004     0.000003     0.000002     0.000001     0.000003     0.000002     0.000004     0.000003     0.000006     0.000005 
 1068.642     0.000001     0.000003     0.000004     0.000002     0.000002     0.000004     0.000003     0.000003     0.000002     0.000004     0.000005     0.000007     0.000006 
 1071.658     0.000001     0.000001     0.000002     0.000002     0.000003     0.000003     0.000000    -0.000000     0.000004     0.000004     0.000006     0.000007     0.000007 
 1074.674     0.000001     0.000001     0.000003     0.000003     0.000003     0.000004     0.000000     0.000002     0.000001     0.000005     0.000006     0.000006     0.000004 
 1077.688     0.000000     0.000002     0.000003     0.000001     0.000003     0.000004     0.000001     0.000002     0.000003     0.000004     0.000006     0.000007     0.000008 
 1080.702     0.000001     0.000003     0.000004     0.000002     0.000001     0.000006     0.000002     0.000002     0.000001     0.000005     0.000006     0.000005     0.000007 
 1083.660     0.000000     0.000004     0.000003     0.000003     0.000000     0.000004     0.000000     0.000001     0.000004     0.000003     0.000005     0.000006     0.000005 
 1086.672     0.000002     0.000004     0.000003     0.000005     0.000001     0.000003     0.000004     0.000002     0.000002     0.000006     0.000005     0.000008     0.000010 
 1089.682     0.000000     0.000002     0.000002     0.000003     0.000003     0.000003     0.000003     0.000002     0.000003     0.000005     0.000002     0.000008     0.000008 
 1092.691    -0.000003     0.000003    -0.000000     0.000003     0.000003     0.000004     0.000001     0.000001     0.000003     0.000002     0.000003     0.000005     0.000006 
 1095.699    -0.000001     0.000003     0.000001     0.000003     0.000002     0.000005     0.000003     0.000001     0.000004     0.000004     0.000004     0.000008     0.000008 
 1098.707    -0.000001     0.000000     0.000002     0.000001     0.000003     0.000004     0.000005    -0.000000     0.000001     0.000006     0.000008     0.000011     0.000005 
 1101.713    -0.000002     0.000004     0.000000     0.000000     0.000003     0.000007     0.000004     0.000001     0.000001     0.000008     0.000003     0.000010     0.000008 
 1104.718    -0.000000     0.000002     0.000001     0.000001     0.000008     0.000007     0.000005    -0.000002     0.000004     0.000010     0.000005     0.000010    -0.000000 
 1107.722    -0.000000     0.000003     0.000006     0.000006     0.000007     0.000004     0.000002     0.000003     0.000007     0.000010     0.000003     0.000012     0.000007 
 1110.725     0.000003     0.000004     0.000008     0.000009     0.000004     0.000008     0.000001    -0.000000     0.000004     0.000010     0.000009     0.000013     0.000006 
 1113.727    -0.000001     0.000006     0.000006     0.000004     0.000006     0.000006     0.000002     0.000009     0.000010     0.000012     0.000009     0.000011     0.000006 
 1116.728    -0.000000     0.000010     0.000008     0.000003     0.000002     0.000006     0.000005     0.000007     0.000010     0.000007     0.000011     0.000014     0.000006 
 1119.728     0.000012     0.000007     0.000008     0.000014     0.000007     0.000015     0.000007     0.000004     0.000011     0.000011     0.000013     0.000020     0.000013 
 1122.726     0.000011     0.000009     0.000008     0.000014     0.000003     0.000007     0.000009     0.000003     0.000008     0.000017     0.000012     0.000017     0.000013 
 1125.724     0.000008     0.000011     0.000007     0.000011     0.000009     0.000012     0.000013     0.000005     0.000008     0.000014     0.000015     0.000020     0.000013 
 1128.720    -0.000001     0.000019     0.000021     0.000007     0.000017     0.000015     0.000002     0.000005     0.000015     0.000014     0.000018     0.000016     0.000010 
 1131.770     0.000002     0.000015     0.000004     0.000014     0.000011     0.000024     0.000009     0.000007     0.000017     0.000014     0.000007     0.000015     0.000020 
 1134.764     0.000004     0.000017     0.000016     0.000014     0.000025     0.000023     0.000016     0.000010     0.000021     0.000012     0.000013     0.000025     0.000027 
 1137.757     0.000008     0.000009     0.000007     0.000016     0.000029     0.000028    -0.000003     0.000013     0.000025     0.000022     0.000009     0.000028     0.000026 
 1140.749     0.000019     0.000016     0.000017     0.000022     0.000011     0.000025     0.000009     0.000016     0.000028     0.000021     0.000011     0.000011     0.000033 
 1143.741     0.000024     0.000016     0.000021     0.000036     0.000020     0.000026     0.000010     0.000023     0.000029     0.000024     0.000027     0.000011     0.000032 
 1146.784     0.000014     0.000031     0.000040     0.000033     0.000017     0.000016     0.000017     0.000020     0.000038     0.000036     0.000018     0.000014     0.000044 
 1149.773     0.000021     0.000020     0.000036     0.000037     0.000025     0.000018     0.000022     0.000038     0.000016     0.000041     0.000031     0.000024     0.000028 
 1152.761     0.000037     0.000020     0.000055     0.000046     0.000018     0.000027     0.000028     0.000043     0.000028     0.000037     0.000017     0.000021     0.000050 
 1155.801     0.000024     0.000026     0.000031     0.000040     0.000044     0.000035     0.000017     0.000042     0.000036     0.000056     0.000051     0.000035     0.000053 
 1158.786    -0.000002     0.000022    -0.000006     0.000033     0.000053     0.000041     0.000010     0.000044     0.000052     0.000037     0.000031     0.000046     0.000087 
 1161.771     0.000023     0.000047    -0.000001     0.000056     0.000046     0.000017    -0.000010     0.000064     0.000056     0.000064     0.000041     0.000049     0.000039 
 1164.807     0.000058     0.000044     0.000012     0.000041     0.000035     0.000052     0.000028     0.000070     0.000067     0.000058     0.000014     0.000077     0.000089 
 1167.790     0.000072     0.000046     0.000031     0.000042     0.000043     0.000033     0.000059     0.000062     0.000091     0.000108     0.000025     0.000094     0.000083 
 1170.771     0.000071    -0.000014     0.000102     0.000063     0.000075     0.000082     0.000044     0.000120     0.000135     0.000091     0.000040     0.000082     0.000127 
 1173.804     0.000033     0.000065     0.000067     0.000058     0.000088     0.000111     0.000074     0.000052     0.000047     0.000047    -0.000007     0.000124     0.000218 
 1176.783     0.000012     0.000013     0.000038     0.000153     0.000071     0.000209     0.000134     0.000185     0.000092     0.000149     0.000174     0.000092     0.000240 
 1179.814     0.000113     0.000191     0.000168     0.000109     0.000115     0.000204    -0.000026     0.000128     0.000350     0.000366     0.000252     0.000336     0.000019 
 1182.790    -0.000065     0.000233    -0.000013     0.000212     0.000219     0.000300    -0.000142     0.000391     0.000415     0.000492     0.000285     0.000450     0.000137 
 1185.819     0.000036     0.000431     0.000654     0.000207     0.000025     0.000068     0.000347     0.000370     0.000660     0.000576     0.000604     0.000342     0.000455 
 1188.793     0.000334     0.000523     0.000385    -0.000070     0.000341     0.000319     0.000179     0.000532     0.000422     0.000340     0.000171     0.000274     0.000212 
 1191.820     0.000312     0.000434     0.000647    -0.000462    -0.000056     0.000754    -0.000166     0.000724     0.000689     0.000234    -0.000048     0.000498     0.000454 
 1194.845     0.000161     0.000069     0.000526    -0.000424    -0.000281     0.000544     0.000027     0.000948     0.000263     0.000470     0.000430     0.000280    -0.000057 
 1197.815     0.000073    -0.000177     0.000498     0.000017     0.000181    -0.000251     0.000560     0.001261    -0.000066     0.001038     0.000279     0.000689     0.000637 
 1200.838    -0.000765     0.001318     0.000274     0.000330     0.000669    -0.000144    -0.000118     0.001638     0.001558     0.000933    -0.000215     0.000530     0.000582 
