# number of points on sci filter + aux + bad z = 0
# number of points on sci filter               = 2
# number of positions in lambda                = 301
# noof scans  1            1          
# x_pos     162.640000  -162.640000 
# y_pos       0.000000     0.000000 
# angle       2.960000     2.960000 
# z_pos      10.000000    10.000000 
# r_pos     162.640000   162.640000 
# phi         0.000000     3.141593 
# gnupl col      2            3      
# pos_id        49           50      
#
# lambda for peak transmission
#          482.9050000  482.9050000 
# peak transmission
#            0.9378500    0.9218360 
# lambda blue with 1/2 of peak transmission
#          389.1962369  391.5102207 
# lambda red  with 1/2 of peak transmission
#          528.4540319  528.5551332 
# half width                              
#          139.2577949  137.0449125 
# central wavelength                      
#          458.8251344  460.0326769 
# central wavelength calculated as SAGEM (mean frequency)
#          448.2586179  449.8261693 
# lambda blue with 80% of peak transmission
#          397.7954285  397.7189278 
# lambda red  with 80% of peak transmission
#          524.9836086  518.8444011 
# lambda blue with 0.0001 of peak transmission
#          375.6848593  375.8977999 
# lambda red  with 0.0001 of peak transmission
#          565.7394365  565.0623265 
# ATB calculated from points above 80%
#            0.8869763    0.8779522 
# ATB calculated from points above 50%
#            0.8600141    0.8461538 
# ABR calculated from points below and above 0.0001
#            0.0862134    0.0907828 
# minCWL      = 458.825134 at column =  2, at id = 49 
# maxCWL      = 460.032677 at column =  3, at id = 50 
# difference =    1.2075425 
# minBW       = 137.044913 at column =  3, at id = 50 
# maxBW       = 139.257795 at column =  2, at id = 49 
# difference =    2.2128824 
# minBlueEdge = 389.196237 at column =  2, at id = 49 
# maxBlueEdge = 391.510221 at column =  3, at id = 50 
# difference =    2.3139837 
# minRedEdge  = 528.454032 at column =  2, at id = 49 
# maxRedEdge  = 528.555133 at column =  3, at id = 50 
# difference =    0.1011013 
# minABR      = 0.086213 at column =  2, at id = 49 
# maxABR      = 0.090783 at column =  3, at id = 50 
# difference =    0.0045694 
  299.645     0.000166     0.000279 
  302.654     0.000126     0.000037 
  305.662     0.000107    -0.000001 
  308.671     0.000032    -0.000023 
  311.679     0.000025    -0.000018 
  314.687     0.000025    -0.000001 
  317.694     0.000051    -0.000001 
  320.702     0.000020    -0.000010 
  323.709     0.000017     0.000005 
  326.716     0.000005     0.000007 
  329.665     0.000009    -0.000000 
  332.672     0.000001    -0.000000 
  335.678    -0.000004     0.000006 
  338.683    -0.000002     0.000001 
  341.689     0.000009     0.000001 
  344.694     0.000014     0.000009 
  347.699     0.000009    -0.000003 
  350.703     0.000007     0.000001 
  353.707     0.000006    -0.000002 
  356.711     0.000003     0.000003 
  359.715     0.000003     0.000001 
  362.718     0.000006    -0.000000 
  365.721     0.000009     0.000003 
  368.724     0.000009     0.000001 
  371.726     0.000006     0.000002 
  374.728     0.000009     0.000001 
  377.730     0.000275     0.000235 
  380.788     0.004297     0.002444 
  383.789     0.016610     0.009101 
  386.789     0.112455     0.082380 
  389.790     0.556851     0.409160 
  392.790     0.604612     0.499424 
  395.790     0.603756     0.609070 
  398.789     0.822874     0.808698 
  401.788     0.816297     0.771246 
  404.787     0.809172     0.796544 
  407.785     0.866784     0.856962 
  410.783     0.866278     0.844630 
  413.781     0.873778     0.864509 
  416.834     0.888636     0.878056 
  419.831     0.905553     0.891237 
  422.828     0.886493     0.872854 
  425.824     0.895266     0.878866 
  428.820     0.907795     0.898438 
  431.815     0.923927     0.913753 
  434.810     0.920050     0.905268 
  437.862     0.885085     0.861040 
  440.856     0.887844     0.874729 
  443.850     0.918336     0.909976 
  446.844     0.903689     0.879814 
  449.837     0.891754     0.866803 
  452.830     0.901902     0.885624 
  455.878     0.918469     0.907719 
  458.870     0.918236     0.903174 
  461.862     0.902191     0.885849 
  464.853     0.906878     0.896708 
  467.901     0.925515     0.915963 
  470.891     0.921045     0.904910 
  473.881     0.899013     0.882673 
  476.871     0.900457     0.889353 
  479.916     0.926546     0.918019 
  482.905     0.937850     0.921836 
  485.894     0.914458     0.889361 
  488.882     0.888236     0.866746 
  491.925     0.902931     0.894061 
  494.913     0.930943     0.920248 
  497.899     0.923039     0.896644 
  500.942     0.901692     0.869269 
  503.928     0.893538     0.865015 
  506.913     0.894314     0.872829 
  509.954     0.906469     0.889974 
  512.939     0.897435     0.871515 
  515.923     0.836501     0.795720 
  518.963     0.782451     0.735104 
  521.946     0.784465     0.733057 
  524.929     0.754520     0.713405 
  527.967     0.518639     0.517762 
  530.949     0.214250     0.229547 
  533.987     0.068694     0.075607 
  536.968     0.023184     0.025248 
  539.948     0.009048     0.009600 
  542.984     0.003989     0.004136 
  545.964     0.001972     0.002015 
  548.999     0.001034     0.001038 
  551.977     0.000591     0.000582 
  555.012     0.000355     0.000346 
  557.989     0.000229     0.000219 
  561.023     0.000157     0.000149 
  563.999     0.000111     0.000102 
  567.032     0.000081     0.000074 
  570.007     0.000063     0.000058 
  573.038     0.000050     0.000041 
  576.013     0.000042     0.000037 
  579.043     0.000036     0.000031 
  582.017     0.000032     0.000025 
  585.046     0.000027     0.000023 
  588.019     0.000029     0.000016 
  591.047     0.000026     0.000018 
  594.019     0.000025     0.000017 
  597.046     0.000025     0.000016 
  600.073     0.000025     0.000017 
  603.043     0.000028     0.000016 
  606.068     0.000029     0.000015 
  609.038     0.000035     0.000018 
  612.062     0.000035     0.000017 
  615.086     0.000036     0.000021 
  618.053     0.000038     0.000021 
  621.076     0.000042     0.000019 
  624.099     0.000047     0.000023 
  627.064     0.000053     0.000028 
  630.086     0.000060     0.000033 
  633.106     0.000077     0.000038 
  636.071     0.000080     0.000035 
  639.090     0.000061     0.000025 
  642.109     0.000043     0.000015 
  645.128     0.000034     0.000016 
  648.090     0.000028     0.000011 
  651.107     0.000020     0.000005 
  654.123     0.000013    -0.000001 
  657.139     0.000010     0.000001 
  660.099     0.000011     0.000001 
  663.114     0.000006     0.000001 
  666.129     0.000011     0.000001 
  669.142     0.000015     0.000005 
  672.155     0.000026     0.000015 
  675.168     0.000060     0.000038 
  678.124     0.000119     0.000074 
  681.136     0.000124     0.000089 
  684.146     0.000076     0.000063 
  687.157     0.000045     0.000040 
  690.166     0.000031     0.000024 
  693.175     0.000022     0.000019 
  696.183     0.000018     0.000017 
  699.191     0.000023     0.000017 
  702.198     0.000028     0.000019 
  705.205     0.000034     0.000031 
  708.211     0.000045     0.000037 
  711.216     0.000051     0.000041 
  714.220     0.000047     0.000038 
  717.224     0.000039     0.000031 
  720.228     0.000027     0.000024 
  723.230     0.000027     0.000019 
  726.232     0.000018     0.000020 
  729.234     0.000020     0.000021 
  732.234     0.000023     0.000020 
  735.235     0.000026     0.000026 
  738.234     0.000031     0.000030 
  741.233     0.000042     0.000042 
  744.231     0.000052     0.000055 
  747.228     0.000076     0.000061 
  750.225     0.000085     0.000070 
  753.221     0.000086     0.000075 
  756.272     0.000084     0.000077 
  759.267     0.000087     0.000071 
  762.261     0.000092     0.000089 
  765.254     0.000101     0.000101 
  768.247     0.000128     0.000130 
  771.294     0.000167     0.000180 
  774.286     0.000247     0.000258 
  777.277     0.000381     0.000416 
  780.266     0.000614     0.000666 
  783.311     0.000976     0.001005 
  786.300     0.001447     0.001394 
  789.288     0.001939     0.001782 
  792.275     0.002297     0.002290 
  795.316     0.002800     0.002868 
  798.302     0.003391     0.003424 
  801.287     0.003941     0.003846 
  804.327     0.004050     0.003692 
  807.310     0.003333     0.002830 
  810.348     0.002254     0.001854 
  813.331     0.001377     0.001148 
  816.312     0.000822     0.000708 
  819.348     0.000492     0.000442 
  822.328     0.000317     0.000281 
  825.362     0.000204     0.000184 
  828.341     0.000140     0.000117 
  831.374     0.000093     0.000080 
  834.351     0.000065     0.000056 
  837.382     0.000046     0.000040 
  840.357     0.000030     0.000037 
  843.387     0.000030     0.000027 
  846.361     0.000023     0.000022 
  849.389     0.000002     0.000008 
  852.362     0.000013     0.000012 
  855.389     0.000012     0.000000 
  858.359     0.000012     0.000003 
  861.385     0.000003     0.000001 
  864.409     0.000003     0.000002 
  867.378     0.000003     0.000003 
  870.400     0.000003     0.000002 
  873.422     0.000004     0.000002 
  876.389     0.000003     0.000002 
  879.409     0.000003     0.000002 
  882.428     0.000003     0.000003 
  885.447     0.000005     0.000003 
  888.410     0.000011     0.000003 
  891.427     0.000024     0.000004 
  894.444     0.000023     0.000003 
  897.459     0.000026     0.000005 
  900.419     0.000027     0.000013 
  903.433     0.000028     0.000022 
  906.446     0.000046     0.000027 
  909.458     0.000049     0.000035 
  912.469     0.000059     0.000043 
  915.480     0.000062     0.000049 
  918.489     0.000070     0.000055 
  921.443     0.000075     0.000059 
  924.451     0.000078     0.000063 
  927.458     0.000076     0.000061 
  930.465     0.000070     0.000058 
  933.470     0.000062     0.000047 
  936.475     0.000056     0.000042 
  939.478     0.000051     0.000039 
  942.481     0.000048     0.000036 
  945.483     0.000050     0.000033 
  948.484     0.000045     0.000037 
  951.484     0.000043     0.000039 
  954.538     0.000059     0.000045 
  957.537     0.000072     0.000057 
  960.534     0.000083     0.000068 
  963.531     0.000098     0.000077 
  966.526     0.000109     0.000088 
  969.521     0.000126     0.000091 
  972.515     0.000124     0.000088 
  975.563     0.000123     0.000089 
  978.555     0.000122     0.000092 
  981.546     0.000124     0.000096 
  984.537     0.000135     0.000105 
  987.580     0.000148     0.000118 
  990.569     0.000161     0.000135 
  993.556     0.000190     0.000157 
  996.543     0.000220     0.000175 
  999.583     0.000235     0.000197 
 1002.568     0.000256     0.000214 
 1005.552     0.000270     0.000226 
 1008.589     0.000285     0.000240 
 1011.571     0.000309     0.000264 
 1014.606     0.000344     0.000296 
 1017.587     0.000392     0.000342 
 1020.620     0.000468     0.000408 
 1023.598     0.000568     0.000503 
 1026.629     0.000701     0.000619 
 1029.606     0.000859     0.000753 
 1032.635     0.001010     0.000873 
 1035.610     0.001102     0.000931 
 1038.637     0.001088     0.000896 
 1041.610     0.000995     0.000798 
 1044.635     0.000861     0.000689 
 1047.660     0.000737     0.000582 
 1050.629     0.000635     0.000505 
 1053.652     0.000563     0.000449 
 1056.620     0.000509     0.000408 
 1059.640     0.000468     0.000372 
 1062.660     0.000450     0.000361 
 1065.678     0.000447     0.000354 
 1068.642     0.000445     0.000362 
 1071.658     0.000469     0.000369 
 1074.674     0.000498     0.000403 
 1077.688     0.000548     0.000446 
 1080.702     0.000607     0.000502 
 1083.660     0.000684     0.000559 
 1086.672     0.000803     0.000709 
 1089.682     0.000996     0.000873 
 1092.691     0.001206     0.001071 
 1095.699     0.001525     0.001378 
 1098.707     0.001955     0.001764 
 1101.713     0.002550     0.002355 
 1104.718     0.003267     0.003028 
 1107.722     0.004114     0.003756 
 1110.725     0.004904     0.004499 
 1113.727     0.005513     0.004974 
 1116.728     0.005855     0.005211 
 1119.728     0.005904     0.005209 
 1122.726     0.005771     0.005061 
 1125.724     0.005630     0.004936 
 1128.720     0.005458     0.004860 
 1131.770     0.005404     0.004809 
 1134.764     0.005470     0.004870 
 1137.757     0.005564     0.005154 
 1140.749     0.005958     0.005465 
 1143.741     0.006556     0.006036 
 1146.784     0.007189     0.006830 
 1149.773     0.008341     0.007887 
 1152.761     0.009765     0.009284 
 1155.801     0.011697     0.011489 
 1158.786     0.014259     0.014322 
 1161.771     0.018302     0.018269 
 1164.807     0.023805     0.024452 
 1167.790     0.031577     0.032973 
 1170.771     0.042788     0.044958 
 1173.804     0.059761     0.064004 
 1176.783     0.082840     0.091775 
 1179.814     0.122949     0.133768 
 1182.790     0.183870     0.195448 
 1185.819     0.260112     0.279689 
 1188.793     0.344678     0.369789 
 1191.820     0.425109     0.455447 
 1194.845     0.518474     0.532799 
 1197.815     0.595614     0.576085 
 1200.838     0.621634     0.614833 
