#Relative Filter Curve created with the VISIR imaging detector and the VISIR calibration unit. #Author = Maximilian Haeberle Contact: max.haeberle18@gmail.com # #Filter = SIV_2 #Central_Wavelength = 10.7064 #FWHM =0.204 # #Minimum_Wavelength = 10.2168 #Maximum_Wavelength = 11.2128 #Wavelength Step = 0.0120001 # #Exposure information #DIT = 0.0248926 #NDIT = 50 #NABBA = 2 # #Data Analysis Information #Zeroth Order = 192 #Normalization factor=48605.1 #Aperture r0= 8.0 #Annulus rA1= 25.36 #Annulus rA2= 30.16 #Mean of first background file = 19056.0683594 # #encvalue wavelength transmission transmission_error 8706.0 10.2168 -0.00210962 0.00317131 8716.0 10.2288 -0.00106625 0.00317131 8726.0 10.2408 0.00443076 0.00317131 8736.0 10.2528 0.00146867 0.00317131 8746.0 10.2648 -0.00127936 0.00317131 8756.0 10.2768 0.00384115 0.00317131 8766.0 10.2888 0.000505452 0.00317131 8776.0 10.3008 0.00185404 0.00317131 8786.0 10.3128 0.000505062 0.00317131 8796.0 10.3248 -0.000897033 0.00317131 8806.0 10.3368 -0.00480492 0.00317131 8816.0 10.3488 0.00332702 0.00317131 8826.0 10.3608 0.00247338 0.00317131 8836.0 10.3728 0.00433397 0.00317131 8846.0 10.3848 0.00126679 0.00317131 8856.0 10.3968 0.00281355 0.00317131 8866.0 10.4088 0.0113104 0.00317131 8876.0 10.4208 0.00591239 0.00317131 8886.0 10.4328 0.00529263 0.00317131 8896.0 10.4448 0.00627321 0.00317131 8906.0 10.4568 0.00938071 0.00317131 8916.0 10.4688 0.0105737 0.00317131 8926.0 10.4808 0.010457 0.00317131 8936.0 10.4928 0.014225 0.00317131 8946.0 10.5048 0.0135719 0.00317131 8956.0 10.5168 0.0260876 0.00317131 8966.0 10.5288 0.0312739 0.00317131 8976.0 10.5408 0.0421194 0.00317131 8986.0 10.5528 0.064778 0.00317131 8996.0 10.5648 0.109947 0.00317131 9006.0 10.5768 0.178671 0.00317131 9016.0 10.5888 0.267962 0.00317131 9026.0 10.6008 0.424527 0.00317131 9036.0 10.6128 0.592052 0.00317131 9046.0 10.6248 0.755838 0.00317131 9056.0 10.6368 0.882994 0.00317131 9066.0 10.6488 0.948437 0.00317131 9076.0 10.6608 0.986169 0.00317131 9086.0 10.6728 0.999958 0.00317131 9096.0 10.6848 0.986701 0.00317131 9106.0 10.6968 0.987517 0.00317131 9116.0 10.7088 1.0 0.00317131 9126.0 10.7208 0.989209 0.00317131 9136.0 10.7328 0.988914 0.00317131 9146.0 10.7448 0.972355 0.00317131 9156.0 10.7568 0.943 0.00317131 9166.0 10.7688 0.910369 0.00317131 9176.0 10.7808 0.832963 0.00317131 9186.0 10.7928 0.70095 0.00317131 9196.0 10.8048 0.542164 0.00317131 9206.0 10.8168 0.363314 0.00317131 9216.0 10.8288 0.235404 0.00317131 9226.0 10.8408 0.152564 0.00317131 9236.0 10.8528 0.086585 0.00317131 9246.0 10.8648 0.0620638 0.00317131 9256.0 10.8768 0.0412374 0.00317131 9266.0 10.8888 0.0258045 0.00317131 9276.0 10.9008 0.0178093 0.00317131 9286.0 10.9128 0.0129306 0.00317131 9296.0 10.9248 0.00783287 0.00317131 9306.0 10.9368 0.0109613 0.00317131 9316.0 10.9488 0.0108251 0.00317131 9326.0 10.9608 0.00168491 0.00317131 9336.0 10.9728 0.00775438 0.00317131 9346.0 10.9848 0.00488843 0.00317131 9356.0 10.9968 0.00650889 0.00317131 9366.0 11.0088 0.00246058 0.00317131 9376.0 11.0208 -0.000568124 0.00317131 9386.0 11.0328 0.00561322 0.00317131 9396.0 11.0448 0.00233374 0.00317131 9406.0 11.0568 -0.00660475 0.00317131 9416.0 11.0688 0.00217363 0.00317131 9426.0 11.0808 -0.000399037 0.00317131 9436.0 11.0928 -1.69088e-05 0.00317131 9446.0 11.1048 0.00608185 0.00317131 9456.0 11.1168 -0.00028318 0.00317131 9466.0 11.1288 -0.00215952 0.00317131 9476.0 11.1408 0.00492531 0.00317131 9486.0 11.1528 0.000919053 0.00317131 9496.0 11.1648 0.00118165 0.00317131 9506.0 11.1768 0.000226829 0.00317131 9516.0 11.1888 -0.00186379 0.00317131 9526.0 11.2008 0.00279437 0.00317131 9536.0 11.2128 0.00411665 0.00317131