XCijjKVt
CEHT i voltage sensor
Datatype: REAL*4              
Units:    Kilovolts           
This parameter monitors both the CEHT 1 and CEHT2. The sensors (jj) monitor the 12kV and 36kV junctions. This parameter reports both the "Fine" and "Course" voltage measures. "Fine" refers to the resolution of the readout. When the voltage is low, XCijjKVC gives an estimate of the value and XCijjKVF is not useful; when the voltage is close to nominal, XCijjKVF gives a more accurate value.
                                                                                
  NIijjKVt reports the minimum voltage                                          
  OIijjKVt reports the maximum voltage                                          
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                Red     Yellow     Yellow        Red                            
    Mode    Minimum    Minimum    Maximum    Maximum                            
  Oper 48     -9.99      10.07      10.48      10.96   XC112KV                  
  Oper 96     -9.99      10.18      10.59      11.07   XC212KV                  
                                                                                

Source : PDB 40D, OMS 12.0

XCiLEDSL
Name of internal LED
Datatype: CHARACTER*08        
Units:    Name                
  One of the following names identifying the lamp:                              
	LED off                                                                        
	None                                                                           
	Yellow                                                                         
	Red                                                                            
	Blue                                                                           
	Red                                                                            
	Green                                                                          
	Yellow 2                                                                       

Source : PDB 40D

XCiLEDIT
internal LED intensity
Datatype: REAL*4              
Units:    Volts               

Source : PDB 40D

XCAMiTjj
CAM i temperature
Datatype: REAL*4              
Units:    Degrees             
  NCAMiTjj reports the minimum value of the temperature at sensor jj            
  OCAMiTjj reports the maximum value of the temperature at sensor jj            
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                  Yellow     Yellow                                             
	Mode	  Minimum    Maximum                                                      
       Oper 48     16.00      25.71    XCAM1TP6                                 
       Oper 48     16.00      28.93   	XCAM1TP8                                 
       Oper 48     16.00      23.33	XCAM1T12                                    
       Oper 48     16.00      25.71    XCAM2TP6                                 
       Oper 48     16.00      28.93   	XCAM2TP8                                 
       Oper 48     16.00      23.33	XCAM2T12                                    
                                                                                

Source : PDB 40D, OMS 12.0

XCEiARFS
CEHT i analog reference signal.
Datatype:                     
Units:                        

Source :

XCEUiTPj
CEU i temperature
Datatype: REAL*4              
Units:    Degrees             
  NCEUiTPj reports the minimum value of the temperature at sensor j             
  OCEUiTPj reports the maximum value of the temperature at sensor j             
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                  Yellow     Yellow                                             
	Mode	  Minimum    Maximum                                                      
       Oper 48    -99.90      26.43    XCEU1TP1                                 
       Oper 96    -99.90      26.43	XCEU2TP1                                    
       Oper 48    -99.90      25.00    XCEU1TP2                                 
       Oper 96    -99.90      25.00	XCEU2TP2                                    
                                                                                

Source : PDB 40D, OMS 12.0

XCUiFCSC
CEUi focus coil current
Datatype: REAL*4              
Units:    milliamps           
  NCUiFCSC reports the minimum value of the current                             
  OCUiFCSC reports the maximum value of the current                             
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                  Yellow     Yellow                                             
	Mode	  Minimum    Maximum                                                      
       Oper 48     65.96      72.47	XCU1FCSC                                    
	Oper 96     67.18      76.86    XCU2FCSC                                       
                                                                                

Source : PDB 40D, OMS 12.0

XCUiGjVL
CEUi voltage at monitor point j
Datatype: REAL*4              
Units:    volts               
  NCUiGjVL reports the minimum voltage at monitor point j                       
  OCUiGjVL reports the maximum voltage at monitor point j                       
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
               Red     Yellow     Yellow        Red                             
    Mode   Minimum    Minimum    Maximum    Maximum                             
  Oper 48   -99.99     -56.15     -51.80     -44.36	XCU1G1VL                    
  Oper 96              -99.99     -44.36		XCU1G1VL                              
  Oper 48              284.70     999.90		XCU1G2VL                              
  Oper 48              762.00     957.00		XCU1G4VL                              
  Oper 96              -47.10     -42.40		XCU2G1VL                              
  Oper 96  		284.70     999.90		XCU2G2VL                                        
  Oper 96  		697.00    1011.00		XCU2G4VL                                        
                                                                                

Source : PDB 40D, OMS 12.0

XCUiG2CR
CEU1 G2 current
Datatype: REAL*4              
Units:    Milliamps           
  NCUiG2CR reports the minimum current                                          
  OCUiG2CR reports the maximum current                                          

Source :

XCUijALC
CEUi horizontal/vertical alignment coil current
Datatype: REAL*4              
Units:    Milliamps           
  NCUiHALC reports the minimum Horizontal coil current                          
  OCUiHALC reports the maximum Horizontal coil current                          
  NCUiHALC reports the minimum Vertical coil current                            
  OCUiHALC reports the maximum Vertical coil current                            
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                   Yellow     Yellow                                            
           Mode   Minimum    Maximum                                            
         Oper 48   -10.60      -4.00	XCU1HALC                                   
         Oper 48    11.10      17.80	XCU1VALC                                   
         Oper 96    21.20      28.80   XCU2HALC                                 
         Oper 96    46.20     999.90   XCU2VALC                                 
                                                                                

Source : PDB 40D, OMS 12.0

XCUiHTRC
CEUi camera tube filament current
Datatype: REAL*4              
Units:    Milliamps           
  NCUiHTRC reports the minimum current                                          
  OCUiHTRC reports the maximum current                                          
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                   Yellow     Yellow                                            
           Mode   Minimum    Maximum                                            
         Oper 48   116.20     184.40	XCU1HTRC                                   
         Oper 96   117.30     182.70 	XCU2HTRC                                  
                                                                                

Source : PDB 40D, OMS 12.0

XCUiPMTR
CEUi photomultiplier assembly trim coil current
Datatype: REAL*4              
Units:    Milliamps           
  NCUiPMTR reports the minimum current                                          
  OCUiPMTR reports the maximum current                                          
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                   Yellow     Yellow                                            
           Mode   Minimum    Maximum                                            
         Oper 48   128.30     158.00	XCU1PMTR                                   
	  Oper 96   131.40     161.10   XCU2PMTR                                       
                                                                                

Source : PDB 40D, OMS 12.0

XCUiTRGT
CEUi target voltage
Datatype: REAL*4              
Units:    Volts               
  NCUiTRGT reports the minimum voltage                                          
  OCUiTRGT reports the maximum voltage                                          
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                   Yellow     Yellow                                            
           Mode   Minimum    Maximum                                            
         Oper 48     6.81       8.00	XCU1TRGT                                   
         Oper 96     6.76       8.00   XCU2TRGT                                 
                                                                                

Source : PDB 40D, OMS 12.0

XEBATMP7
EBA temperature 7 sink sensor
Datatype: REAL*4              
Units:    Degrees             
  NEBATMP7 reports the minimum temperature                                      
  OEBATMP7 reports the maximum temperature                                      
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
               Red     Yellow     Yellow        Red                             
    Mode   Minimum    Minimum    Maximum    Maximum                             
  Oper 48   -41.37     -41.37      -8.53      20.52                             
  Oper 96   -41.37     -41.37      -8.53      20.52                             
                                                                                

Source : PDB 40D, OMS 12.0

XEBATMP8
EBA housekeeping temperature 8
Datatype: REAL*4              
Units:    Degrees             
  NEBATMP8 reports the minimum value of the temperature                         
  OEBATMP8 reports the maximum value of the temperature                         
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                  Yellow     Yellow                                             
	Mode	  Minimum    Maximum                                                      
      Oper 48     -31.14       5.66                                             
      Oper 96     -31.14       5.66                                             
                                                                                

Source : PDB 40D, OMS 12.0

XIijjKVt
IEHT i voltage sensor
Datatype: REAL*4              
Units:    Kilovolts           
This parameter monitors both the IEHT 1 and IEHT2. The sensors (jj) monitor the 12kV and 36kV junctions. This parameter reports both the "Fine" and "Course" voltage measures. "Fine" refers to the resolution of the readout. When the voltage is low, XIijjKVC gives an estimate of the value and XIijjKVF is not useful; when the voltage is close to nominal, XIijjKVF gives a more accurate value.
                                                                                
  NIijjKVt reports the minimum voltage                                          
  OIijjKVt reports the maximum voltage                                          
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                 Yellow     Yellow                                              
         Mode   Minimum    Maximum                                              
       Oper 48    10.27      10.47	XI112KVt                                     
       Oper 48    36.19      36.79	XI136KVt                                     
       Oper 96    10.13      10.43	XI212KVt                                     
       Oper 96    36.10      36.70	XI236KVt                                     
                                                                                

Source : PDB 40D, OMS 12.0

XINTiTPj
INT i temperature at sensor j
Datatype: REAL*4              
Units:    Degrees             
This parameter monitors both the INT 1 and INT 2 temperatures at four sensor points.
                                                                                
  NINTiTPj reports the minimum temperature                                      
  OINTiTPj reports the maximum temperature                                      
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                 Yellow     Yellow                                              
         Mode   Minimum    Maximum                                              
       Oper 48    16.00      20.33	XINT1TP1                                     
       Oper 48    16.00      20.33	XINT1TP2                                     
       Oper 48    16.00      20.33	XINT1TP3                                     
       Oper 48    16.00      21.00	XINT1TP4                                     
       Oper 96    16.00      20.33	XINT2TP1                                     
       Oper 96    16.00      20.33	XINT2TP2                                     
       Oper 96    16.00      20.33	XINT2TP3                                     
       Oper 96    16.00      21.00	XINT2TP4                                     
                                                                                

Source : PDB 40D, OMS 12.0

XOBETMPj
OBE housekeeping temperature at sensor j
Datatype: REAL*4              
Units:    Degrees             
                                                                                
  NOBETMPj reports the minimum temperature                                      
  OOBETMPj reports the maximum temperature                                      
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
               Red     Yellow     Yellow        Red                             
    Mode   Minimum    Minimum    Maximum    Maximum                             
  Oper 48     7.17      16.25      17.74      22.75	XOBETMP1                    
  Oper 96     7.17      16.25      17.74      22.75    XOBETMP1                 
  Oper 48               16.25      17.74               XOBETMP2                 
  Oper 96               16.25      17.74               XOBETMP2                 
  Oper 48               16.25      17.74               XOBETMP3                 
  Oper 96               16.25      17.74               XOBETMP3                 
  Oper 48     7.17      16.25      17.74      22.75    XOBETMP4                 
  Oper 96     7.17      16.25      17.74      22.75    XOBETMP4                 
  Oper 48               16.25      17.74               XOBETMP5                 
  Oper 96               16.25      17.74               XOBETMP5                 
  Oper 48     7.17      16.25      17.74      22.75    XOBETMP6                 
  Oper 96     7.17      16.25      17.74      22.75    XOBETMP6                 
                                                                                

Source : PDB 40D, OMS 12.0

XPDATMjj
photon detector unit housekeeping temperature at sensor j
Datatype: REAL*4              
Units:    Degrees             
                                                                                
  NPDATMjj reports the minimum temperature at sensor jj                         
  OPDATMjj reports the maximum temperature at sensor jj                         
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
               Red     Yellow     Yellow        Red                             
    Mode   Minimum    Minimum    Maximum    Maximum                             
  Oper 48    -9.90     -15.31      20.00      32.58    XPDATMP9                 
  Oper 96    -9.90     -15.31      20.00      32.58    XPDATMP9                 
  Oper 48              -25.22      10.30               XPDATM10                 
  Oper 96              -25.22      10.30               XPDATM10                 
                                                                                

Source : PDB 40D, OMS 12.0

XRIUiTMP
RIU i housekeeping temperature
Datatype: REAL*4              
Units:    Degrees             
                                                                                
  NRIUiTMP reports the minimum temperature                                      
  ORIUiTMP reports the maximum temperature                                      
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
               Red     Yellow     Yellow        Red                             
    Mode   Minimum    Minimum    Maximum    Maximum                             
  Oper 48   -40.10     -25.65      13.85      40.20    XRIUATMP                 
  Oper 96   -40.10     -25.65      13.85      40.20    XRIUATMP                 
  Oper 48   -40.10     -25.65      13.85      40.20    XRIUBTMP                 
  Oper 96   -40.10     -25.65      13.85      40.20    XRIUBTMP                 
                                                                                

Source : PDB 40D, OMS 12.0

XSDSiVLT
SDS2 (science data store) housekeeping voltage
Datatype: REAL*4              
Units:    Volts               
                                                                                
  NSDSiVLT reports the minimum voltage                                          
  OSDSiVLT reports the maximum voltage                                          
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                 Yellow     Yellow                                              
         Mode   Minimum    Maximum                                              
       Oper 48     4.34       4.88    XSDS1VLT                                  
       Oper 96     0.00       0.62    XSDS1VLT                                  
       Oper 48     0.00       0.62    XSDS2VLT                                  
       Oper 96     4.34       4.88    XSDS2VLT                                  
                                                                                

Source : PDB 40D, OMS 12.0

XViTHARM
VPU1 (video processing unit) threshold arming level
Datatype: REAL*4              
Units:    Volts               
                                                                                
  NViTHARM reports the minimum voltage                                          
  OViTHARM reports the maximum voltage                                          
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                 Yellow     Yellow                                              
         Mode   Minimum    Maximum                                              
       Oper 48     0.28       0.70	XV1THARM                                     
       Oper 96     0.28       0.70	XV2THARM                                     
                                                                                

Source : PDB 40D, OMS 12.0

XViTHEXT
VPU1 (video processing unit) threshold extent level
Datatype: REAL*4              
Units:    Volts               
                                                                                
  NViTHEXT reports the minimum voltage                                          
  OViTHEXT reports the maximum voltage                                          
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                 Yellow     Yellow                                              
         Mode   Minimum    Maximum                                              
       Oper 48     0.28       0.76	XV1THEXT                                     
       Oper 96     0.28       0.76	XV2THEXT                                     
                                                                                

Source : PDB 40D, OMS 12.0

XVPiPRLT
VPU i (video processing unit) PRL temperature
Datatype: REAL*4              
Units:    Degrees             
This parameter monitors both the VPU 1 and VPU 2 temperatures.
                                                                                
  NVPiPRLT reports the minimum temperature                                      
  OVPiPRLT reports the maximum temperature                                      
                                                                                
  For normal operations this parameter should be within:                        
                                                                                
                 Yellow     Yellow                                              
         Mode   Minimum    Maximum                                              
       Oper 48   -99.90      38.90 	XVP1PRLT                                    
       Oper 96   -99.90      38.90 	XVP2PRLT                                    
                                                                                

Source : PDB 40D, OMS 12.0

XC48RFMP
Focussing mirror position for the f/48 relay.
Datatype: INTEGER*4           
Units:    Position            
The integer values range over approximately 0 to 225, each step corresponding to 0.083 mm in mirror position, which is 0.166 mm in optical path length. This is at f/48 if COSTAR is not in use or f/75 if COSTAR is used.

Source : PDB 40D, OMS 12.0

XC96RFMP
Focussing mirror position for the f/96 relay.
Datatype: INTEGER*4           
Units:    Position            
The integer values range over approximately 0 to 225, each step corresponding to 0.083 mm in mirror position, which is 0.166 mm in optical path length. This is at f/96 if COSTAR is not in use or f/151 if COSTAR is used.

Source : PDB 40D, OMS 12.0

XNPSBjjS
Power status buffer expected status.
Datatype: INTEGER*4           
Units:    Status Code         
This parameter reports the expected status of both the power status buffers.

Source :

XEXPTMnn
exposure stop time 1 (sc clock counts)
Datatype: INTEGER*4           
Units:                        
Telemetered values to determine the actual exposure time nn=odd: Exposure start or restart time nn=even: Exposure stop time.

Source :