HST Keyword Dictionary
Space Telescope Science Institute
3700 San Martin Drive
Baltimore, MD 21212
_____________________________________________________
Keyword Definitions for the
- High Resolution Spectrograph
- Standard Header Packet
This is version 11.4, dated 16-NOV-1987
_____________________________________________________
- KXBFOCUS
- COSTAR FOC M1 Focus Position (mm)
Datatype: REAL*4
Units: mm
-
Source :
- KZBFOCUS
- COSTAR HRS M1 Focus Position (mm)
Datatype: REAL*4
Units: mm
-
Source :
- KZBXTILT
- COSTAR HRS M1 X-tilt Position (arcsec)
Datatype: REAL*4
Units: arcsec
-
Source :
- KZBYTILT
- COSTAR HRS M1 Y-tilt Position (arcsec)
Datatype: REAL*4
Units: arcsec
-
Source :
- KZDEPLOY
- COSTAR deployed for HRS (T or F)
Datatype: LOGICAL*1
Units:
-
Source :
- SCIDATA
- science data present:T/F (actual not predicted)
Datatype: LOGICAL*1
Units:
-
Source :
- SS_DET
- detector in use (1-2)
Datatype: INTEGER*2
Units:
-
Source :
- SS_GRAT
- grating,echelle or mirror in use mode
Datatype: CHARACTER*09
Units:
-
Source :
- SS_MODE
- data mode
Datatype: CHARACTER*18
Units:
-
Source :
- ZACMODE1
- acquisition mode
Datatype: CHARACTER*08
Units:
-
0: spectral science data
1: focus diode field map
3: single frame
(SO-01p3-424)
Source :
- ZCST
- carrousel stator temperature
Datatype: REAL*4
Units:
-
Source :
- ZDEBTF
- DEB front post amp. temperature
Datatype: REAL*4
Units:
-
Source :
- ZDEBTR
- DEB rear post amp temperature
Datatype: REAL*4
Units:
-
Source :
- ZDETT1
- det. 1 temperature
Datatype: REAL*4
Units:
-
Source :
- ZDETT2
- det. 2 temperature
Datatype: REAL*4
Units:
-
Source :
- ZDRT
- digicon radiator tem
Datatype: REAL*4
Units:
-
Source :
- ZDT11
- det. 1 detector shield temperature #1
Datatype: REAL*4
Units:
-
Source :
- ZDT12
- det. 2 detector shield temperature #1
Datatype: REAL*4
Units:
-
Source :
- ZET11
- det. 1 enclosure temperature #1
Datatype: REAL*4
Units:
-
Source :
- ZET31
- det. 1 enclosure temperature #3
Datatype: REAL*4
Units:
-
Source :
- ZFIAT
- fixture interface A temperature
Datatype: REAL*4
Units:
-
Source :
- ZFIBT
- fixture interface B temperature
Datatype: REAL*4
Units:
-
Source :
- ZFICT
- fixture interface C temperature
Datatype: REAL*4
Units:
-
Source :
- ZHDC1
- det. 1 horizontal deflection current
Datatype: REAL*4
Units:
-
Source :
- ZHDC2
- det. 2 horizontal deflection current
Datatype: REAL*4
Units:
-
Source :
- ZHVPST1
- det. 1 high voltage power supply temperature
Datatype: REAL*4
Units:
-
Source :
- ZHVPST2
- det. 2 high voltage power supply temperature
Datatype: REAL*4
Units:
-
Source :
- ZMEBT1
- main elec box 1 temperature
Datatype: REAL*4
Units:
-
Source :
- ZMEBT2
- main elec box 2 temperature
Datatype: REAL*4
Units:
-
Source :
- ZOBBT
- optical bench bulkhead temperature
Datatype: REAL*4
Units:
-
Source :
- ZOBT11
- det. 1 optical bench temperature #1
Datatype: REAL*4
Units:
-
Source :
- ZPABT1
- det. 1 preamp assembly box temperature
Datatype: REAL*4
Units:
-
Source :
- ZPABT2
- det. 2 preamp assembly box temperature
Datatype: REAL*4
Units:
-
Source :
- ZPCC1
- det. 1 photo cathode current
Datatype: REAL*4
Units:
-
Source :
- ZPCC2
- det. 2 photo cathode current
Datatype: REAL*4
Units:
-
Source :
- ZPCV1
- det. 1 photo cathode high voltage
Datatype: REAL*4
Units:
-
Source :
- ZPCV2
- det. 2 photo cathode high voltage
Datatype: REAL*4
Units:
-
Source :
- ZRIUTA
- RIU A internal temperature
Datatype: REAL*4
Units:
-
Source :
- ZRIUTB
- RIU B internal temperature
Datatype: REAL*4
Units:
-
Source :
- ZSCT1
- det. 1 spectral calibration lamp temperature
Datatype: REAL*4
Units:
-
Source :
- ZSCT2
- det. 2 spectral calibration lamp temperature
Datatype: REAL*4
Units:
-
Source :
- ZTST11
- det. 1 thermal shelf temperature #1
Datatype: REAL*4
Units:
-
Source :
HST Keyword Dictionary: 3/15/94: (rose@stsci.edu)