Calibrating amplitude errors

The errors on the amplitudes of the visibility and the triple can be recomputed based on their formal uncertainties and the calibration error. The latter is derived from the variation of the calibrator visibilities and the comparison to their formal errors. Both are added in quadrature. This procedure requires the selection of calibrator and program stars.