Description:
Stop the APD measurements setting the APD gate to 0 and opening the
APD loop.
As soon as the loop is open M6 goes automatically to center position.
The center position is defined as (0,0) plus the offset
value set in the SETUP database branch.
Role(s)/Actor(s):
Primary: Operator/Maintenance
Secondary: FSS Strap
|
![]() | Interface: IfFss.Control.Stop |
Exception Course: Command failed
Issues to be Determined or Resolved: The behaviour of the M6 as controlled by the APD system must be still analyzed on more details. This will most probably cause modifications in the FSS and M6 Use Cases and the introduction of new Use Cases for the M6.
ACTION MCO: Verify the following points regarding the interaction of the STRAP system with the M6:
Notes:
Last modified: Thu Jun 28 13:19:01 UTC 2001