mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
UVES:
lamps: stability (580 REDU)
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
UVES trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-04-25T06:19:05 (UT)
  | now: 2024-04-25T12:37:43 (UT) muc02 QC pipeline: uves-6.1.11 (installed 2023-06-22)
same group: FF_LAMP3 Flux_FF_LAMP3 ThAr_LAMP1 SFLAT_LAMP5
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
UVES news:  
Report news:
DATE*: [?] 2024-04-18
report | NLT
2024-04-19
report | NLT
2024-04-20
report | NLT
2024-04-21
report | NLT
2024-04-22
report | NLT
2024-04-23
report | NLT
2024-04-24
report | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw raw
P...
CAL product quality:
products products products products products products products
 
transfer   ngas [?]

scores&comments | FULL | history ... | plot tutorial ... | contact | HC_docu... | quality events...                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 0.173 counts/sec none  77 int_avg this | last_yr | all Flux of FLAMES/UVES SIMCAL arclamp, from 580.0nm, 1x1, Plate 1 data, REDU CCD, in fibre 1.
2 QC1DB MEDIAN 0.49 counts/sec none  78 int_avg this | last_yr | all Flux of FLAMES/UVES robotic arclamp Same data as for plot 1, fibre 2
3 QC1DB MEDIAN 0.546 counts/sec none  78 int_avg this | last_yr | all same as plot 2, fibre 3
4 QC1DB MEDIAN 0.53 counts/sec VAL0.35,0.9 78 int_avg this | last_yr | all same as plot 2, fibre 4

5 QC1DB MEDIAN 0.587 counts/sec VAL0.35,0.9 78 int_avg this | last_yr | all same as plot 2, fibre 5This plot is scored
6 QC1DB MEDIAN 0.455 counts/sec none  78 int_avg this | last_yr | all same as plot 2, fibre 6
7 QC1DB MEDIAN 0.412 counts/sec none  78 int_avg this | last_yr | all same as plot 2, fibre 7
8 QC1DB MEDIAN 0.587 counts/sec none  78 int_avg this | last_yr | all same as plot 2, fibre 8
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:uves_fib_wave
(QC1 database)
dataset:int_avg
median:0.173counts/sec
thresholds:none 
N_data plotted:77
[click plot for closeup]
Plot 2
scores: not implemented
data source:uves_fib_wave
(QC1 database)
dataset:int_avg
median:0.49counts/sec
thresholds:none 
N_data plotted:78
[click plot for closeup]
Plot 3
scores: not implemented
data source:uves_fib_wave
(QC1 database)
dataset:int_avg
median:0.546counts/sec
thresholds:none 
N_data plotted:78
[click plot for closeup]
Plot 4
scores: not implemented
data source:uves_fib_wave_scoreQC
(QC1 database)
dataset:int_avg
median:0.53counts/sec
fixed thresholds:0.35...0.9counts/sec
N_data plotted:78
[click plot for closeup]
Plot 5
scores: 9|
data source:uves_fib_wave_fib5
(QC1 database)
dataset:int_avg
median:0.587counts/sec
fixed thresholds:0.35...0.9counts/sec
N_data plotted:78
[click plot for closeup]
Plot 6
scores: not implemented
data source:uves_fib_wave
(QC1 database)
dataset:int_avg
median:0.455counts/sec
thresholds:none 
N_data plotted:78
[click plot for closeup]
Plot 7
scores: not implemented
data source:uves_fib_wave
(QC1 database)
dataset:int_avg
median:0.412counts/sec
thresholds:none 
N_data plotted:78
[click plot for closeup]
Plot 8
scores: not implemented
data source:uves_fib_wave
(QC1 database)
dataset:int_avg
median:0.587counts/sec
thresholds:none 
N_data plotted:78
[click plot for closeup]
This plot

This is the Health Check report for the FLAMES/UVES wavelength calibration lamp. It is based on data taken with the RED UPPER CCD in setting 580, 7+1FIB, with Plate 1. These data are taken daily as part of the Health Checks. The lamp is identified in the headers by HIERARCH ESO INS1 LAMP1 NAME = 'ThAr_Lamp'.
Find the corresponding data for the RED LOWER CCD here. To avoid redundancy, these data are not scored.

Note: we score only Fibre 5 data here, to follow the lamp performance. Any issue with individual fibres is not scored here but would become visible in the plot.

Trends in this plot probably indicate aging of the lamp. This lamp is used for wavelength calibration and format check calibrations.

The individual plots describe:

  • Fibre 1: The average of the line intensities, QC.FIB1.INTAVG, measured on a selection of lines (taken from the LINE_INTMON_TABLE, if provided, in the sof, normally UV_GLIM_040226A_line_intmon_table.fits).
    This fibre 1 is illuminated by the simultaneous calibration ThAr lamp.
  • Fibres 2-8: The average of the intensity values, QC.FIB[2-8].INTAVG, measured for a subset of lines (same as above). These fibres are illuminated by the robotic fibre projector fed by the ThAr lamp.

Find more information about FLAMES/UVES Lamp monitoring here.  
General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up