[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
VIRCAM trending system: HISTORY plot
Last update: 2011-03-13T05:19:58 (UT)
same group: RESETMED RESETRMS RESETDIFFRMS   temperatures
close window history: 2009 2010   2011   2012   2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023   HEALTH
  ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 16.7304 ADU VAL1,30 62 qc_resetdiff_rms this | last_yr | all RESETDIFFRMS, average over all 16 detectors
2 QC1DB MEDIAN 14.57453 ADU VAL1,50 991 qc_resetdiff_rms this | last_yr | all RESETDIFFRMS, values of all detetcors
3 QC1DB MEDIAN 4.97318 ADU VAL0.01,20 62 qc_resetdiff_rms this | last_yr | all RESETDIFFRMS, stdev over all detectors
4 LOCAL none   ADU none   990 qc_resetdiff_rms n/a Score per Detector: Green = within the thresholds
4 LOCAL none   ADU none   2 qc_resetdiff_rms n/a Score per Detector: Red = beyond thresholds
4 .LOCAL none   ADU none   990 qc_resetdiff_rms n/a Score per Detector: Green = within the thresholds
4 .LOCAL none   ADU none   2 qc_resetdiff_rms n/a Score per Detector: Red = beyond thresholds
*Data sources: QC1DB: QC1 database; LOCAL: local text file
Plot 1
data source:vircam_reset
(QC1 database)
parameter | dataset:qc_resetdiff_rms
median:16.7304ADU
fixed thresholds:1.0...30.0ADU
N_data:62
[click on plot for closeup]
Plot 2
data source:vircam_reset
(QC1 database)
parameter | dataset:qc_resetdiff_rms
median:14.57453ADU
fixed thresholds:1.0...50.0ADU
N_data:991
[click on plot for closeup]
Plot 3
data source:vircam_reset
(QC1 database)
parameter | dataset:qc_resetdiff_rms
median:4.97318ADU
fixed thresholds:0.01...20.0ADU
N_data:62
[click on plot for closeup]
Plot 4
data source:local text file
parameter | dataset:
(numbers applicable to )
qc_resetdiff_rms
average:none
thresholds:none
N_data:990
[click on plot for closeup]
This plot

Trending plot for RMS noise in MASTER_BIAS minus REFERENCE_BIAS combined product frame.

QC parameters is derived from each detector of daily RESET calibrations.

Name:
Fits header: QC.RESETDIFFRMS,
QC1 DB: qc_resetdiff_rms

Description:
RMS noise of master minus reference product frame

Setup:
DET.DIT = MINDIT = 1.0011 sec

These plots describe:
Fig. 1. Average view: The QC parameter averaged over all detectors. This view is sensitive to common changes.
Fig. 2. Resolved View: The QC parameter resolved for all detectors.
Fig. 3. Scatter View: The standard deviation of the QC parameter, obtained from the sample of all detectors. This view is sensitive changes of individual detectors.
Fig. 4. Scoring View: Scoring values of all 16 QC parameters. Green = within the acceptance thresholds. Red = beyond the acceptance thresholds.

Find more information on the VIRCAM RESET tutorial page.

 


General information

Click on any of the plots to see a close-up version. The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up