VIRCAM trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2023-06-12T10:21:49 (UT)
  | now: 2024-05-05T09:11:47 (UT) muc07 QC pipeline: vcam-2.3.9 (installed 2022-03-17)
same group: GAIN COUNTS LAMP_FLUX   DARKCURRENT
close window history: 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022   2023   HEALTH FULL
  ... ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
  • detetcor #6 video card change on 2009-11-20 had no impact on gain
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 4.36 e-/ADU none  17 qc_gain this | last_yr | all GAIN, average over all 16 detectors
2 QC1DB MEDIAN 4.17 e-/ADU none  271 qc_gain this | last_yr | all GAIN, values of all detetcors
2 QC1DB none   e-/ADU none  17 qc_gain this | last_yr | all GAIN, values of detector 7
2 QC1DB none   e-/ADU none  17 qc_gain this | last_yr | all GAIN, values of detector 3
2 QC1DB none   e-/ADU none  17 qc_gain this | last_yr | all GAIN, values of detector 6
3 QC1DB MEDIAN 0.646 e-/ADU none  17 qc_gain this | last_yr | all GAIN, stdev over all detectors
4 LOCAL none   e-/ADU none  0 qc_gain n/a Score per Detector: Green = within the thresholds
4 LOCAL none   e-/ADU none  0 qc_gain n/a Score per Detector: Red = beyond thresholds
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:vircam_gain
(QC1 database)
dataset:qc_gain
median:4.36e-/ADU
thresholds:none 
N_data plotted:17
[click plot for closeup]
Plot 2
scores: not implemented
data source:vircam_gain
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_gain
median:4.17e-/ADU
thresholds:none 
N_data plotted:271
[click plot for closeup]
Plot 3
scores: not implemented
data source:vircam_gain
(QC1 database)
dataset:qc_gain
median:0.646e-/ADU
thresholds:none 
N_data plotted:17
[click plot for closeup]
Plot 4
scores: not implemented
data source:local data source
dataset:
(numbers below apply to this dataset)
qc_gain
average:none
thresholds:none
N_data plotted:0
[click plot for closeup]
This plot

The scoring thresholds of the individual chips used in box (4) are:

CHIP_16 4.70 6.7
CHIP_15 3.00 5.0
CHIP_14 3.50 5.5
CHIP_13 4.50 6.5
CHIP_12 3.00 5.0
CHIP_11 3.50 5.5
CHIP_10 3.00 5.0
CHIP_9 3.50 5.5
CHIP_8 3.00 5.0
CHIP_7 3.00 5.0
CHIP_6 3.00 5.0
CHIP_5 3.00 5.0
CHIP_4 3.50 5.5
CHIP_3 3.00 5.0
CHIP_2 3.00 5.0
CHIP_1 2.45 4.0
 


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up