[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
VIRCAM trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2023-06-12T10:00:44 (UT)
  | now: 2024-09-24T15:33:09 (UT) muc07 QC pipeline: vcam-2.3.9 (installed 2022-03-17)
same group: IQ_NB118 IQ_Z IQ_Y IQ_J IQ_H IQ_K
close window history: 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022   2023   HEALTH FULL
  ... ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
  • 2009-05-28: Scoring (red/green squares in the group bar and in the navigation bar) is on the detector average (Fig. 1) and detector rms (Fig. 3) values alone.
  • 2009-05-28: Scores of individual detector values (Fig. 4) are for detailed analysis but do not contribute to the overall instrument score.
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 0.737 arcsec VAL0.51,1.7 38 qc_image_size this | last_yr | all IQ in arcsec K, average over all 16 detectors
2 QC1DB MEDIAN 0.746 arcsec VAL0.51,1.7 608 qc_image_size this | last_yr | all IQ in arcsec K, values of all detectors
3 QC1DB MEDIAN 0.0473 arcsec VAL0.0,0.2 38 qc_image_size this | last_yr | all IQ in arcsec K, stdev over all detectors
4 LOCAL none   arcsec none  592 qc_image_size n/a Score per Detector: Green = within the thresholds
4 LOCAL none   arcsec none  16 qc_image_size n/a Score per Detector: Red = beyond thresholds
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:vircam_photstd
(QC1 database)
dataset:qc_image_size
median:0.737arcsec
fixed thresholds:0.51...1.7arcsec
N_data plotted:38
[click plot for closeup]
Plot 2
scores: not implemented
data source:vircam_photstd
(QC1 database)
dataset:qc_image_size
median:0.746arcsec
fixed thresholds:0.51...1.7arcsec
N_data plotted:608
[click plot for closeup]
Plot 3
scores: not implemented
data source:vircam_photstd
(QC1 database)
dataset:qc_image_size
median:0.0473arcsec
fixed thresholds:0.0...0.2arcsec
N_data plotted:38
[click plot for closeup]
Plot 4
scores: not implemented
data source:local data source
dataset:
(numbers below apply to this dataset)
qc_image_size
average:none
thresholds:none
N_data plotted:592
[click plot for closeup]
This plot

The scoring thresholds of the individual chips used in box (4) are:

CHIP_16 0.408 1.7
CHIP_15 0.408 1.7
CHIP_14 0.408 1.7
CHIP_13 0.408 1.7
CHIP_12 0.408 1.7
CHIP_11 0.408 1.7
CHIP_10 0.408 1.7
CHIP_9 0.408 1.7
CHIP_8 0.408 1.7
CHIP_7 0.408 1.7
CHIP_6 0.408 1.7
CHIP_5 0.408 1.7
CHIP_4 0.408 1.7
CHIP_3 0.408 1.7
CHIP_2 0.408 1.7
CHIP_1 0.408 1.7
 


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up