spxw, spgw, mag, dit, snr, max
25mas, J_low, 3.0, 1.6, 1933.9, 12227.3
25mas, J_low, 3.5, 1.6, 1517.9, 7714.9
25mas, J_low, 4.0, 1.6, 1183.8, 4867.8
25mas, J_low, 4.5, 1.6, 914.7, 3071.4
25mas, J_low, 5.0, 1.6, 697.6, 1937.9
25mas, J_low, 5.5, 1.6, 522.9, 1222.7
25mas, J_low, 6.0, 1.6, 383.5, 771.5
25mas, J_low, 6.5, 1.6, 274.3, 486.8
25mas, J_low, 7.0, 1.6, 191.2, 307.1
25mas, J_low, 7.5, 1.6, 130.0, 193.8
25mas, J_low, 8.0, 1.9, 100.0, 143.6
25mas, J_low, 8.5, 3.0, 100.0, 142.6
25mas, J_low, 9.0, 4.6, 100.0, 140.7
25mas, J_low, 9.5, 7.0, 100.0, 134.1
25mas, J_low, 10.0, 10.3, 100.0, 124.4
25mas, J_low, 10.5, 15.1, 100.0, 115.8
25mas, J_low, 11.0, 22.5, 100.0, 108.6
25mas, J_low, 11.5, 33.7, 100.0, 105.5
25mas, J_low, 12.0, 52.3, 100.0, 108.7
25mas, J_low, 12.5, 86.5, 100.0, 125.3
25mas, J_low, 13.0, 151.7, 100.0, 159.5
25mas, J_short, 3.0, 1.6, 1157.4, 4276.6
25mas, J_short, 3.5, 1.6, 893.3, 2698.3
25mas, J_short, 4.0, 1.6, 680.2, 1702.5
25mas, J_short, 4.5, 1.6, 508.8, 1074.2
25mas, J_short, 5.0, 1.6, 372.2, 677.8
25mas, J_short, 5.5, 1.6, 265.5, 427.7
25mas, J_short, 6.0, 1.6, 184.6, 269.8
25mas, J_short, 6.5, 1.6, 125.2, 170.3
25mas, J_short, 7.0, 2.0, 100.0, 131.8
25mas, J_short, 7.5, 3.1, 100.0, 130.7
25mas, J_short, 8.0, 4.8, 100.0, 128.9
25mas, J_short, 8.5, 7.3, 100.0, 122.3
25mas, J_short, 9.0, 10.7, 100.0, 114.2
25mas, J_short, 9.5, 15.7, 100.0, 107.4
25mas, J_short, 10.0, 23.4, 100.0, 102.3
25mas, J_short, 10.5, 35.0, 100.0, 99.5
25mas, J_short, 11.0, 54.5, 100.0, 101.5
25mas, J_short, 11.5, 90.3, 100.0, 113.3
25mas, J_short, 12.0, 159.4, 100.0, 139.1
25mas, J_short, 12.5, 310.3, 100.0, 196.3
25mas, J_short, 13.0, 640.6, 100.0, 309.8
25mas, J_middle, 3.0, 1.6, 1194.3, 4525.6
25mas, J_middle, 3.5, 1.6, 923.1, 2855.5
25mas, J_middle, 4.0, 1.6, 704.2, 1801.7
25mas, J_middle, 4.5, 1.6, 527.9, 1136.8
25mas, J_middle, 5.0, 1.6, 387.1, 717.3
25mas, J_middle, 5.5, 1.6, 276.9, 452.6
25mas, J_middle, 6.0, 1.6, 192.9, 285.5
25mas, J_middle, 6.5, 1.6, 131.1, 180.2
25mas, J_middle, 7.0, 1.9, 100.0, 132.3
25mas, J_middle, 7.5, 2.9, 100.0, 131.3
25mas, J_middle, 8.0, 4.6, 100.0, 129.6
25mas, J_middle, 8.5, 6.9, 100.0, 124.0
25mas, J_middle, 9.0, 10.2, 100.0, 115.7
25mas, J_middle, 9.5, 15.0, 100.0, 108.7
25mas, J_middle, 10.0, 22.3, 100.0, 103.5
25mas, J_middle, 10.5, 33.4, 100.0, 100.1
25mas, J_middle, 11.0, 51.6, 100.0, 101.6
25mas, J_middle, 11.5, 85.1, 100.0, 112.5
25mas, J_middle, 12.0, 148.7, 100.0, 138.3
25mas, J_middle, 12.5, 287.0, 100.0, 197.3
25mas, J_middle, 13.0, 600.0, 100.0, 320.5
25mas, J_long, 3.0, 1.6, 1114.0, 4510.5
25mas, J_long, 3.5, 1.6, 858.5, 2845.9
25mas, J_long, 4.0, 1.6, 652.5, 1795.6
25mas, J_long, 4.5, 1.6, 486.9, 1133.0
25mas, J_long, 5.0, 1.6, 355.2, 714.9
25mas, J_long, 5.5, 1.6, 252.7, 451.0
25mas, J_long, 6.0, 1.6, 175.2, 284.6
25mas, J_long, 6.5, 1.6, 118.6, 179.6
25mas, J_long, 7.0, 2.1, 100.0, 147.8
25mas, J_long, 7.5, 3.3, 100.0, 146.4
25mas, J_long, 8.0, 5.1, 100.0, 144.1
25mas, J_long, 8.5, 7.6, 100.0, 136.0
25mas, J_long, 9.0, 11.3, 100.0, 126.8
25mas, J_long, 9.5, 16.6, 100.0, 119.6
25mas, J_long, 10.0, 24.7, 100.0, 114.6
25mas, J_long, 10.5, 37.2, 100.0, 112.7
25mas, J_long, 11.0, 58.1, 100.0, 117.0
25mas, J_long, 11.5, 97.3, 100.0, 133.3
25mas, J_long, 12.0, 174.0, 100.0, 167.7
25mas, J_long, 12.5, 342.1, 100.0, 242.2
25mas, J_long, 13.0, 697.8, 100.0, 381.3
25mas, H_low, 3.0, 1.6, 1834.2, 12626.5
25mas, H_low, 3.5, 1.6, 1437.8, 7966.8
25mas, H_low, 4.0, 1.6, 1119.4, 5026.7
25mas, H_low, 4.5, 1.6, 862.7, 3171.7
25mas, H_low, 5.0, 1.6, 655.7, 2001.2
25mas, H_low, 5.5, 1.6, 489.3, 1262.7
25mas, H_low, 6.0, 1.6, 356.9, 796.7
25mas, H_low, 6.5, 1.6, 253.8, 503.5
25mas, H_low, 7.0, 1.6, 175.9, 319.0
25mas, H_low, 7.5, 1.6, 119.1, 202.6
25mas, H_low, 8.0, 2.1, 100.0, 167.9
25mas, H_low, 8.5, 3.3, 100.0, 169.1
25mas, H_low, 9.0, 5.1, 100.0, 170.7
25mas, H_low, 9.5, 7.6, 100.0, 167.6
25mas, H_low, 10.0, 11.2, 100.0, 167.9
25mas, H_low, 10.5, 16.6, 100.0, 175.0
25mas, H_low, 11.0, 24.8, 100.0, 194.8
25mas, H_low, 11.5, 37.6, 100.0, 233.2
25mas, H_low, 12.0, 59.4, 100.0, 306.2
25mas, H_low, 12.5, 100.7, 100.0, 453.0
25mas, H_low, 13.0, 183.4, 100.0, 748.8
25mas, H_short, 3.0, 1.6, 1157.6, 4754.2
25mas, H_short, 3.5, 1.6, 893.5, 2999.7
25mas, H_short, 4.0, 1.6, 680.3, 1892.7
25mas, H_short, 4.5, 1.6, 508.7, 1194.2
25mas, H_short, 5.0, 1.6, 371.9, 753.5
25mas, H_short, 5.5, 1.6, 265.1, 475.4
25mas, H_short, 6.0, 1.6, 184.1, 300.0
25mas, H_short, 6.5, 1.6, 124.8, 190.0
25mas, H_short, 7.0, 2.0, 100.0, 148.8
25mas, H_short, 7.5, 3.1, 100.0, 149.1
25mas, H_short, 8.0, 4.8, 100.0, 150.7
25mas, H_short, 8.5, 7.3, 100.0, 149.4
25mas, H_short, 9.0, 10.7, 100.0, 148.1
25mas, H_short, 9.5, 15.8, 100.0, 151.7
25mas, H_short, 10.0, 23.5, 100.0, 163.1
25mas, H_short, 10.5, 35.4, 100.0, 186.0
25mas, H_short, 11.0, 55.3, 100.0, 231.9
25mas, H_short, 11.5, 92.3, 100.0, 328.5
25mas, H_short, 12.0, 164.3, 100.0, 522.4
25mas, H_short, 12.5, 322.6, 100.0, 948.5
25mas, H_short, 13.0, 665.5, 100.0, 1855.5
25mas, H_middle, 3.0, 1.6, 1049.3, 4809.4
25mas, H_middle, 3.5, 1.6, 806.1, 3034.6
25mas, H_middle, 4.0, 1.6, 609.9, 1914.9
25mas, H_middle, 4.5, 1.6, 452.4, 1208.4
25mas, H_middle, 5.0, 1.6, 327.8, 762.6
25mas, H_middle, 5.5, 1.6, 231.4, 481.3
25mas, H_middle, 6.0, 1.6, 159.3, 303.8
25mas, H_middle, 6.5, 1.6, 107.1, 191.8
25mas, H_middle, 7.0, 2.3, 100.0, 177.4
25mas, H_middle, 7.5, 3.7, 100.0, 176.1
25mas, H_middle, 8.0, 5.7, 100.0, 173.4
25mas, H_middle, 8.5, 8.4, 100.0, 166.8
25mas, H_middle, 9.0, 12.4, 100.0, 166.6
25mas, H_middle, 9.5, 18.3, 100.0, 172.3
25mas, H_middle, 10.0, 27.3, 100.0, 187.4
25mas, H_middle, 10.5, 41.6, 100.0, 219.0
25mas, H_middle, 11.0, 66.5, 100.0, 282.8
25mas, H_middle, 11.5, 112.9, 100.0, 408.1
25mas, H_middle, 12.0, 208.8, 100.0, 671.2
25mas, H_middle, 12.5, 421.7, 100.0, 1248.9
25mas, H_middle, 13.0, 836.8, 100.0, 2344.6
25mas, H_long, 3.0, 1.6, 895.5, 4247.3
25mas, H_long, 3.5, 1.6, 682.3, 2679.8
25mas, H_long, 4.0, 1.6, 511.0, 1690.9
25mas, H_long, 4.5, 1.6, 374.5, 1066.9
25mas, H_long, 5.0, 1.6, 267.8, 673.1
25mas, H_long, 5.5, 1.6, 186.7, 424.7
25mas, H_long, 6.0, 1.6, 127.0, 268.0
25mas, H_long, 6.5, 1.9, 100.0, 203.8
25mas, H_long, 7.0, 3.0, 100.0, 202.2
25mas, H_long, 7.5, 4.7, 100.0, 199.5
25mas, H_long, 8.0, 7.1, 100.0, 193.5
25mas, H_long, 8.5, 10.5, 100.0, 188.3
25mas, H_long, 9.0, 15.5, 100.0, 188.1
25mas, H_long, 9.5, 23.1, 100.0, 195.5
25mas, H_long, 10.0, 34.7, 100.0, 213.9
25mas, H_long, 10.5, 54.0, 100.0, 254.5
25mas, H_long, 11.0, 89.6, 100.0, 340.5
25mas, H_long, 11.5, 158.2, 100.0, 509.6
25mas, H_long, 12.0, 308.1, 100.0, 879.8
25mas, H_long, 12.5, 636.6, 100.0, 1671.6
25mas, H_long, 13.0, 1000.0, 88.9, 2480.4
25mas, K_low, 3.0, 1.6, 1323.8, 8964.1
25mas, K_low, 3.5, 1.6, 1027.4, 5656.0
25mas, K_low, 4.0, 1.6, 788.4, 3568.8
25mas, K_low, 4.5, 1.6, 595.7, 2251.8
25mas, K_low, 5.0, 1.6, 441.3, 1420.9
25mas, K_low, 5.5, 1.6, 319.4, 896.6
25mas, K_low, 6.0, 1.6, 225.3, 565.8
25mas, K_low, 6.5, 1.6, 155.0, 357.1
25mas, K_low, 7.0, 1.6, 104.2, 225.4
25mas, K_low, 7.5, 2.4, 100.0, 214.8
25mas, K_low, 8.0, 3.8, 100.0, 213.0
25mas, K_low, 8.5, 5.8, 100.0, 207.8
25mas, K_low, 9.0, 8.7, 100.0, 195.9
25mas, K_low, 9.5, 12.9, 100.0, 186.7
25mas, K_low, 10.0, 19.2, 100.0, 181.9
25mas, K_low, 10.5, 29.0, 100.0, 183.9
25mas, K_low, 11.0, 45.6, 100.0, 201.1
25mas, K_low, 11.5, 76.5, 100.0, 244.2
25mas, K_low, 12.0, 137.9, 100.0, 334.2
25mas, K_low, 12.5, 275.0, 100.0, 532.9
25mas, K_low, 13.0, 591.9, 100.0, 1075.0
25mas, K_short, 3.0, 1.6, 895.0, 3920.1
25mas, K_short, 3.5, 1.6, 681.6, 2473.4
25mas, K_short, 4.0, 1.6, 510.0, 1560.6
25mas, K_short, 4.5, 1.6, 373.2, 984.7
25mas, K_short, 5.0, 1.6, 266.4, 621.3
25mas, K_short, 5.5, 1.6, 185.2, 392.0
25mas, K_short, 6.0, 1.6, 125.7, 247.4
25mas, K_short, 6.5, 2.0, 100.0, 190.6
25mas, K_short, 7.0, 3.1, 100.0, 189.1
25mas, K_short, 7.5, 4.8, 100.0, 186.5
25mas, K_short, 8.0, 7.2, 100.0, 177.3
25mas, K_short, 8.5, 10.6, 100.0, 164.9
25mas, K_short, 9.0, 15.7, 100.0, 154.5
25mas, K_short, 9.5, 23.4, 100.0, 151.0
25mas, K_short, 10.0, 35.2, 100.0, 152.8
25mas, K_short, 10.5, 55.2, 100.0, 167.5
25mas, K_short, 11.0, 92.6, 100.0, 206.5
25mas, K_short, 11.5, 166.3, 100.0, 286.1
25mas, K_short, 12.0, 329.3, 100.0, 461.0
25mas, K_short, 12.5, 681.9, 100.0, 816.7
25mas, K_short, 13.0, 1000.0, 84.0, 1070.0
25mas, K_middle, 3.0, 1.6, 857.1, 3857.8
25mas, K_middle, 3.5, 1.6, 651.0, 2434.1
25mas, K_middle, 4.0, 1.6, 485.3, 1535.9
25mas, K_middle, 4.5, 1.6, 353.7, 969.1
25mas, K_middle, 5.0, 1.6, 251.3, 611.5
25mas, K_middle, 5.5, 1.6, 174.0, 385.8
25mas, K_middle, 6.0, 1.6, 117.6, 243.5
25mas, K_middle, 6.5, 2.1, 100.0, 202.4
25mas, K_middle, 7.0, 3.3, 100.0, 200.6
25mas, K_middle, 7.5, 5.2, 100.0, 197.4
25mas, K_middle, 8.0, 7.7, 100.0, 186.5
25mas, K_middle, 8.5, 11.4, 100.0, 174.6
25mas, K_middle, 9.0, 16.8, 100.0, 168.2
25mas, K_middle, 9.5, 25.1, 100.0, 166.4
25mas, K_middle, 10.0, 38.2, 100.0, 171.8
25mas, K_middle, 10.5, 60.6, 100.0, 191.5
25mas, K_middle, 11.0, 103.6, 100.0, 239.8
25mas, K_middle, 11.5, 191.6, 100.0, 341.0
25mas, K_middle, 12.0, 388.8, 100.0, 560.8
25mas, K_middle, 12.5, 794.5, 100.0, 977.0
25mas, K_middle, 13.0, 1000.0, 75.4, 1095.6
25mas, K_long, 3.0, 1.6, 730.1, 3783.0
25mas, K_long, 3.5, 1.6, 548.9, 2387.0
25mas, K_long, 4.0, 1.6, 404.1, 1506.1
25mas, K_long, 4.5, 1.6, 290.4, 950.3
25mas, K_long, 5.0, 1.6, 203.4, 599.7
25mas, K_long, 5.5, 1.6, 139.0, 378.4
25mas, K_long, 6.0, 1.7, 100.0, 259.1
25mas, K_long, 6.5, 2.7, 100.0, 257.8
25mas, K_long, 7.0, 4.3, 100.0, 255.0
25mas, K_long, 7.5, 6.5, 100.0, 245.5
25mas, K_long, 8.0, 9.7, 100.0, 229.0
25mas, K_long, 8.5, 14.3, 100.0, 216.3
25mas, K_long, 9.0, 21.3, 100.0, 209.5
25mas, K_long, 9.5, 32.2, 100.0, 208.9
25mas, K_long, 10.0, 50.5, 100.0, 221.9
25mas, K_long, 10.5, 85.3, 100.0, 261.2
25mas, K_long, 11.0, 154.4, 100.0, 343.3
25mas, K_long, 11.5, 309.4, 100.0, 524.1
25mas, K_long, 12.0, 654.8, 100.0, 890.4
25mas, K_long, 12.5, 1000.0, 85.2, 1149.1
25mas, K_long, 13.0, 1000.0, 55.0, 1016.1
100mas, J_low, 3.0, NaN, NaN, NaN
100mas, J_low, 3.5, NaN, NaN, NaN
100mas, J_low, 4.0, NaN, NaN, NaN
100mas, J_low, 4.5, NaN, NaN, NaN
100mas, J_low, 5.0, 1.6, 724.5, 31186.1
100mas, J_low, 5.5, 1.6, 544.4, 19677.1
100mas, J_low, 6.0, 1.6, 400.5, 12415.4
100mas, J_low, 6.5, 1.6, 287.4, 7833.6
100mas, J_low, 7.0, 1.6, 201.0, 4942.7
100mas, J_low, 7.5, 1.6, 137.1, 3118.6
100mas, J_low, 8.0, 1.8, 100.0, 2172.7
100mas, J_low, 8.5, 2.8, 100.0, 2161.0
100mas, J_low, 9.0, 4.4, 100.0, 2136.1
100mas, J_low, 9.5, 6.6, 100.0, 2052.3
100mas, J_low, 10.0, 9.8, 100.0, 1911.4
100mas, J_low, 10.5, 14.5, 100.0, 1787.5
100mas, J_low, 11.0, 21.7, 100.0, 1683.6
100mas, J_low, 11.5, 32.8, 100.0, 1649.3
100mas, J_low, 12.0, 51.5, 100.0, 1721.0
100mas, J_low, 12.5, 86.6, 100.0, 2016.7
100mas, J_low, 13.0, 155.5, 100.0, 2624.9
100mas, J_short, 3.0, NaN, NaN, NaN
100mas, J_short, 3.5, NaN, NaN, NaN
100mas, J_short, 4.0, 1.6, 709.6, 27834.9
100mas, J_short, 4.5, 1.6, 532.3, 17562.6
100mas, J_short, 5.0, 1.6, 390.8, 11081.3
100mas, J_short, 5.5, 1.6, 279.9, 6991.8
100mas, J_short, 6.0, 1.6, 195.3, 4411.5
100mas, J_short, 6.5, 1.6, 133.0, 2783.5
100mas, J_short, 7.0, 1.8, 100.0, 2010.1
100mas, J_short, 7.5, 2.9, 100.0, 1996.7
100mas, J_short, 8.0, 4.5, 100.0, 1971.4
100mas, J_short, 8.5, 6.8, 100.0, 1885.3
100mas, J_short, 9.0, 10.1, 100.0, 1760.4
100mas, J_short, 9.5, 14.9, 100.0, 1658.4
100mas, J_short, 10.0, 22.1, 100.0, 1582.5
100mas, J_short, 10.5, 33.2, 100.0, 1537.4
100mas, J_short, 11.0, 51.6, 100.0, 1568.9
100mas, J_short, 11.5, 85.6, 100.0, 1748.8
100mas, J_short, 12.0, 150.9, 100.0, 2141.6
100mas, J_short, 12.5, 293.8, 100.0, 3015.3
100mas, J_short, 13.0, 614.0, 100.0, 4801.8
100mas, J_middle, 3.0, NaN, NaN, NaN
100mas, J_middle, 3.5, NaN, NaN, NaN
100mas, J_middle, 4.0, 1.6, 731.0, 28993.8
100mas, J_middle, 4.5, 1.6, 549.4, 18293.9
100mas, J_middle, 5.0, 1.6, 404.2, 11542.6
100mas, J_middle, 5.5, 1.6, 290.1, 7282.9
100mas, J_middle, 6.0, 1.6, 202.8, 4595.2
100mas, J_middle, 6.5, 1.6, 138.3, 2899.4
100mas, J_middle, 7.0, 1.8, 100.0, 2001.7
100mas, J_middle, 7.5, 2.8, 100.0, 1990.5
100mas, J_middle, 8.0, 4.3, 100.0, 1966.5
100mas, J_middle, 8.5, 6.6, 100.0, 1893.5
100mas, J_middle, 9.0, 9.7, 100.0, 1773.2
100mas, J_middle, 9.5, 14.3, 100.0, 1670.3
100mas, J_middle, 10.0, 21.3, 100.0, 1589.8
100mas, J_middle, 10.5, 31.9, 100.0, 1541.5
100mas, J_middle, 11.0, 49.6, 100.0, 1569.8
100mas, J_middle, 11.5, 82.1, 100.0, 1746.5
100mas, J_middle, 12.0, 144.4, 100.0, 2158.5
100mas, J_middle, 12.5, 280.3, 100.0, 3093.8
100mas, J_middle, 13.0, 589.2, 100.0, 5049.5
100mas, J_long, 3.0, NaN, NaN, NaN
100mas, J_long, 3.5, NaN, NaN, NaN
100mas, J_long, 4.0, 1.6, 674.8, 28465.5
100mas, J_long, 4.5, 1.6, 504.8, 17960.5
100mas, J_long, 5.0, 1.6, 369.3, 11332.3
100mas, J_long, 5.5, 1.6, 263.6, 7150.2
100mas, J_long, 6.0, 1.6, 183.3, 4511.5
100mas, J_long, 6.5, 1.6, 124.4, 2846.6
100mas, J_long, 7.0, 2.0, 100.0, 2220.4
100mas, J_long, 7.5, 3.1, 100.0, 2201.8
100mas, J_long, 8.0, 4.9, 100.0, 2172.4
100mas, J_long, 8.5, 7.3, 100.0, 2062.1
100mas, J_long, 9.0, 10.8, 100.0, 1924.6
100mas, J_long, 9.5, 15.9, 100.0, 1820.9
100mas, J_long, 10.0, 23.8, 100.0, 1752.6
100mas, J_long, 10.5, 36.0, 100.0, 1730.8
100mas, J_long, 11.0, 56.7, 100.0, 1810.0
100mas, J_long, 11.5, 95.7, 100.0, 2082.1
100mas, J_long, 12.0, 173.2, 100.0, 2653.5
100mas, J_long, 12.5, 344.5, 100.0, 3880.3
100mas, J_long, 13.0, 709.1, 100.0, 6170.8
100mas, H_low, 3.0, NaN, NaN, NaN
100mas, H_low, 3.5, NaN, NaN, NaN
100mas, H_low, 4.0, NaN, NaN, NaN
100mas, H_low, 4.5, NaN, NaN, NaN
100mas, H_low, 5.0, 1.6, 668.9, 32541.3
100mas, H_low, 5.5, 1.6, 499.6, 20532.3
100mas, H_low, 6.0, 1.6, 364.8, 12955.1
100mas, H_low, 6.5, 1.6, 259.8, 8187.2
100mas, H_low, 7.0, 1.6, 180.2, 5186.9
100mas, H_low, 7.5, 1.6, 122.1, 3293.8
100mas, H_low, 8.0, 2.0, 100.0, 2656.6
100mas, H_low, 8.5, 3.2, 100.0, 2686.5
100mas, H_low, 9.0, 5.0, 100.0, 2730.9
100mas, H_low, 9.5, 7.6, 100.0, 2704.7
100mas, H_low, 10.0, 11.3, 100.0, 2737.5
100mas, H_low, 10.5, 17.0, 100.0, 2895.6
100mas, H_low, 11.0, 25.9, 100.0, 3280.4
100mas, H_low, 11.5, 40.4, 100.0, 4035.1
100mas, H_low, 12.0, 66.7, 100.0, 5534.7
100mas, H_low, 12.5, 117.8, 100.0, 8512.4
100mas, H_low, 13.0, 228.2, 100.0, 14949.6
100mas, H_short, 3.0, NaN, NaN, NaN
100mas, H_short, 3.5, NaN, NaN, NaN
100mas, H_short, 4.0, 1.6, 696.8, 31236.2
100mas, H_short, 4.5, 1.6, 521.8, 19708.9
100mas, H_short, 5.0, 1.6, 382.2, 12435.7
100mas, H_short, 5.5, 1.6, 272.9, 7846.6
100mas, H_short, 6.0, 1.6, 189.9, 4951.0
100mas, H_short, 6.5, 1.6, 128.9, 3133.8
100mas, H_short, 7.0, 1.9, 100.0, 2364.3
100mas, H_short, 7.5, 3.0, 100.0, 2374.9
100mas, H_short, 8.0, 4.7, 100.0, 2403.7
100mas, H_short, 8.5, 7.1, 100.0, 2396.9
100mas, H_short, 9.0, 10.5, 100.0, 2384.6
100mas, H_short, 9.5, 15.6, 100.0, 2456.6
100mas, H_short, 10.0, 23.5, 100.0, 2658.8
100mas, H_short, 10.5, 35.8, 100.0, 3060.3
100mas, H_short, 11.0, 56.8, 100.0, 3866.0
100mas, H_short, 11.5, 96.9, 100.0, 5566.9
100mas, H_short, 12.0, 177.2, 100.0, 9073.3
100mas, H_short, 12.5, 355.8, 100.0, 16808.7
100mas, H_short, 13.0, 733.8, 100.0, 32834.4
100mas, H_middle, 3.0, NaN, NaN, NaN
100mas, H_middle, 3.5, NaN, NaN, NaN
100mas, H_middle, 4.0, 1.6, 622.9, 31137.8
100mas, H_middle, 4.5, 1.6, 462.7, 19648.9
100mas, H_middle, 5.0, 1.6, 335.8, 12400.0
100mas, H_middle, 5.5, 1.6, 237.5, 7826.2
100mas, H_middle, 6.0, 1.6, 163.7, 4940.3
100mas, H_middle, 6.5, 1.6, 110.3, 3119.5
100mas, H_middle, 7.0, 2.3, 100.0, 2796.4
100mas, H_middle, 7.5, 3.6, 100.0, 2781.8
100mas, H_middle, 8.0, 5.5, 100.0, 2751.3
100mas, H_middle, 8.5, 8.3, 100.0, 2655.7
100mas, H_middle, 9.0, 12.3, 100.0, 2665.0
100mas, H_middle, 9.5, 18.2, 100.0, 2771.3
100mas, H_middle, 10.0, 27.4, 100.0, 3036.6
100mas, H_middle, 10.5, 42.3, 100.0, 3588.0
100mas, H_middle, 11.0, 68.7, 100.0, 4703.5
100mas, H_middle, 11.5, 118.5, 100.0, 6890.1
100mas, H_middle, 12.0, 224.6, 100.0, 11592.3
100mas, H_middle, 12.5, 462.9, 100.0, 21989.0
100mas, H_middle, 13.0, 917.4, 100.0, 41192.5
100mas, H_long, 3.0, NaN, NaN, NaN
100mas, H_long, 3.5, NaN, NaN, NaN
100mas, H_long, 4.0, 1.6, 520.9, 27108.8
100mas, H_long, 4.5, 1.6, 382.3, 17104.5
100mas, H_long, 5.0, 1.6, 273.8, 10792.2
100mas, H_long, 5.5, 1.6, 191.1, 6809.4
100mas, H_long, 6.0, 1.6, 130.2, 4296.5
100mas, H_long, 6.5, 1.9, 100.0, 3175.5
100mas, H_long, 7.0, 3.0, 100.0, 3155.9
100mas, H_long, 7.5, 4.6, 100.0, 3119.9
100mas, H_long, 8.0, 7.0, 100.0, 3041.4
100mas, H_long, 8.5, 10.3, 100.0, 2969.6
100mas, H_long, 9.0, 15.3, 100.0, 2980.8
100mas, H_long, 9.5, 23.0, 100.0, 3117.9
100mas, H_long, 10.0, 34.8, 100.0, 3436.9
100mas, H_long, 10.5, 54.7, 100.0, 4130.5
100mas, H_long, 11.0, 91.9, 100.0, 5593.2
100mas, H_long, 11.5, 164.8, 100.0, 8498.0
100mas, H_long, 12.0, 324.9, 100.0, 14851.0
100mas, H_long, 12.5, 670.9, 100.0, 28193.6
100mas, H_long, 13.0, 1000.0, 85.2, 39694.3
100mas, K_low, 3.0, NaN, NaN, NaN
100mas, K_low, 3.5, NaN, NaN, NaN
100mas, K_low, 4.0, NaN, NaN, NaN
100mas, K_low, 4.5, 1.6, 598.3, 36001.7
100mas, K_low, 5.0, 1.6, 442.6, 22716.5
100mas, K_low, 5.5, 1.6, 319.9, 14334.1
100mas, K_low, 6.0, 1.6, 225.4, 9045.6
100mas, K_low, 6.5, 1.6, 154.8, 5709.1
100mas, K_low, 7.0, 1.6, 104.0, 3604.0
100mas, K_low, 7.5, 2.4, 100.0, 3474.2
100mas, K_low, 8.0, 3.9, 100.0, 3499.2
100mas, K_low, 8.5, 6.1, 100.0, 3487.1
100mas, K_low, 9.0, 9.5, 100.0, 3403.6
100mas, K_low, 9.5, 14.9, 100.0, 3452.0
100mas, K_low, 10.0, 24.6, 100.0, 3727.3
100mas, K_low, 10.5, 43.4, 100.0, 4399.6
100mas, K_low, 11.0, 84.7, 100.0, 5970.6
100mas, K_low, 11.5, 179.9, 100.0, 9180.9
100mas, K_low, 12.0, 408.3, 100.0, 15821.5
100mas, K_low, 12.5, 938.3, 100.0, 29081.9
100mas, K_low, 13.0, 1000.0, 66.4, 29058.5
100mas, K_short, 3.0, NaN, NaN, NaN
100mas, K_short, 3.5, NaN, NaN, NaN
100mas, K_short, 4.0, 1.6, 516.0, 25281.5
100mas, K_short, 4.5, 1.6, 377.9, 15951.7
100mas, K_short, 5.0, 1.6, 269.9, 10065.0
100mas, K_short, 5.5, 1.6, 187.8, 6350.8
100mas, K_short, 6.0, 1.6, 127.5, 4007.3
100mas, K_short, 6.5, 1.9, 100.0, 3040.9
100mas, K_short, 7.0, 3.0, 100.0, 3025.6
100mas, K_short, 7.5, 4.8, 100.0, 2998.9
100mas, K_short, 8.0, 7.2, 100.0, 2871.9
100mas, K_short, 8.5, 10.8, 100.0, 2704.7
100mas, K_short, 9.0, 16.2, 100.0, 2585.5
100mas, K_short, 9.5, 25.0, 100.0, 2607.4
100mas, K_short, 10.0, 39.9, 100.0, 2794.3
100mas, K_short, 10.5, 69.0, 100.0, 3380.1
100mas, K_short, 11.0, 130.5, 100.0, 4691.9
100mas, K_short, 11.5, 273.3, 100.0, 7572.9
100mas, K_short, 12.0, 611.2, 100.0, 13759.4
100mas, K_short, 12.5, 1000.0, 85.9, 19232.6
100mas, K_short, 13.0, 1000.0, 55.1, 17163.6
100mas, K_middle, 3.0, NaN, NaN, NaN
100mas, K_middle, 3.5, 1.6, 656.7, 38916.7
100mas, K_middle, 4.0, 1.6, 489.6, 24555.1
100mas, K_middle, 4.5, 1.6, 356.8, 15493.6
100mas, K_middle, 5.0, 1.6, 253.5, 9776.1
100mas, K_middle, 5.5, 1.6, 175.6, 6168.6
100mas, K_middle, 6.0, 1.6, 118.7, 3892.5
100mas, K_middle, 6.5, 2.1, 100.0, 3208.8
100mas, K_middle, 7.0, 3.3, 100.0, 3195.7
100mas, K_middle, 7.5, 5.2, 100.0, 3168.1
100mas, K_middle, 8.0, 7.8, 100.0, 3030.4
100mas, K_middle, 8.5, 11.8, 100.0, 2900.5
100mas, K_middle, 9.0, 18.1, 100.0, 2897.7
100mas, K_middle, 9.5, 28.7, 100.0, 3041.9
100mas, K_middle, 10.0, 48.7, 100.0, 3503.9
100mas, K_middle, 10.5, 91.3, 100.0, 4614.4
100mas, K_middle, 11.0, 187.9, 100.0, 6951.2
100mas, K_middle, 11.5, 418.6, 100.0, 11914.5
100mas, K_middle, 12.0, 941.1, 100.0, 21712.5
100mas, K_middle, 12.5, 1000.0, 66.4, 19672.0
100mas, K_middle, 13.0, 1000.0, 42.4, 17526.6
100mas, K_long, 3.0, NaN, NaN, NaN
100mas, K_long, 3.5, 1.6, 551.8, 38127.1
100mas, K_long, 4.0, 1.6, 406.0, 24057.3
100mas, K_long, 4.5, 1.6, 291.6, 15179.8
100mas, K_long, 5.0, 1.6, 204.2, 9578.5
100mas, K_long, 5.5, 1.6, 139.5, 6044.3
100mas, K_long, 6.0, 1.7, 100.0, 4129.6
100mas, K_long, 6.5, 2.8, 100.0, 4138.4
100mas, K_long, 7.0, 4.4, 100.0, 4138.1
100mas, K_long, 7.5, 6.7, 100.0, 4047.9
100mas, K_long, 8.0, 10.3, 100.0, 3888.4
100mas, K_long, 8.5, 16.0, 100.0, 3871.5
100mas, K_long, 9.0, 26.1, 100.0, 4103.5
100mas, K_long, 9.5, 46.0, 100.0, 4771.4
100mas, K_long, 10.0, 90.6, 100.0, 6355.0
100mas, K_long, 10.5, 195.7, 100.0, 9572.1
100mas, K_long, 11.0, 450.9, 100.0, 16018.7
100mas, K_long, 11.5, 1000.0, 97.6, 27073.5
100mas, K_long, 12.0, 1000.0, 62.4, 21740.3
100mas, K_long, 12.5, 1000.0, 39.7, 18375.3
100mas, K_long, 13.0, 1000.0, 25.2, 16252.2
250mas, J_low, 3.0, NaN, NaN, NaN
250mas, J_low, 3.5, NaN, NaN, NaN
250mas, J_low, 4.0, NaN, NaN, NaN
250mas, J_low, 4.5, NaN, NaN, NaN
250mas, J_low, 5.0, NaN, NaN, NaN
250mas, J_low, 5.5, NaN, NaN, NaN
250mas, J_low, 6.0, NaN, NaN, NaN
250mas, J_low, 6.5, NaN, NaN, NaN
250mas, J_low, 7.0, 1.6, 290.5, 29306.2
250mas, J_low, 7.5, 1.6, 218.9, 18491.1
250mas, J_low, 8.0, 1.6, 161.6, 11667.2
250mas, J_low, 8.5, 1.6, 116.5, 7361.6
250mas, J_low, 9.0, 2.1, 100.0, 6018.0
250mas, J_low, 9.5, 3.3, 100.0, 5995.1
250mas, J_low, 10.0, 5.1, 100.0, 5949.1
250mas, J_low, 10.5, 7.9, 100.0, 5727.5
250mas, J_low, 11.0, 11.9, 100.0, 5476.8
250mas, J_low, 11.5, 18.2, 100.0, 5453.8
250mas, J_low, 12.0, 28.3, 100.0, 5655.9
250mas, J_low, 12.5, 45.4, 100.0, 6347.0
250mas, J_low, 13.0, 76.3, 100.0, 7778.9
250mas, J_short, 3.0, NaN, NaN, NaN
250mas, J_short, 3.5, NaN, NaN, NaN
250mas, J_short, 4.0, NaN, NaN, NaN
250mas, J_short, 4.5, NaN, NaN, NaN
250mas, J_short, 5.0, NaN, NaN, NaN
250mas, J_short, 5.5, NaN, NaN, NaN
250mas, J_short, 6.0, 1.6, 284.8, 26433.5
250mas, J_short, 6.5, 1.6, 214.4, 16678.5
250mas, J_short, 7.0, 1.6, 158.0, 10523.4
250mas, J_short, 7.5, 1.6, 113.7, 6639.9
250mas, J_short, 8.0, 2.1, 100.0, 5600.6
250mas, J_short, 8.5, 3.4, 100.0, 5564.2
250mas, J_short, 9.0, 5.3, 100.0, 5529.4
250mas, J_short, 9.5, 8.0, 100.0, 5346.1
250mas, J_short, 10.0, 12.0, 100.0, 5155.1
250mas, J_short, 10.5, 18.1, 100.0, 5043.0
250mas, J_short, 11.0, 27.6, 100.0, 5057.8
250mas, J_short, 11.5, 43.2, 100.0, 5324.9
250mas, J_short, 12.0, 70.1, 100.0, 6030.4
250mas, J_short, 12.5, 118.6, 100.0, 7404.3
250mas, J_short, 13.0, 213.5, 100.0, 10221.8
250mas, J_middle, 3.0, NaN, NaN, NaN
250mas, J_middle, 3.5, NaN, NaN, NaN
250mas, J_middle, 4.0, NaN, NaN, NaN
250mas, J_middle, 4.5, NaN, NaN, NaN
250mas, J_middle, 5.0, NaN, NaN, NaN
250mas, J_middle, 5.5, NaN, NaN, NaN
250mas, J_middle, 6.0, 1.6, 293.3, 27396.1
250mas, J_middle, 6.5, 1.6, 221.1, 17285.8
250mas, J_middle, 7.0, 1.6, 163.3, 10906.6
250mas, J_middle, 7.5, 1.6, 117.7, 6881.6
250mas, J_middle, 8.0, 2.0, 100.0, 5543.5
250mas, J_middle, 8.5, 3.2, 100.0, 5527.2
250mas, J_middle, 9.0, 5.1, 100.0, 5511.2
250mas, J_middle, 9.5, 7.7, 100.0, 5341.1
250mas, J_middle, 10.0, 11.5, 100.0, 5153.2
250mas, J_middle, 10.5, 17.5, 100.0, 5048.6
250mas, J_middle, 11.0, 26.8, 100.0, 5073.7
250mas, J_middle, 11.5, 41.9, 100.0, 5356.7
250mas, J_middle, 12.0, 68.4, 100.0, 6178.5
250mas, J_middle, 12.5, 116.3, 100.0, 7802.0
250mas, J_middle, 13.0, 210.2, 100.0, 11006.0
250mas, J_long, 3.0, NaN, NaN, NaN
250mas, J_long, 3.5, NaN, NaN, NaN
250mas, J_long, 4.0, NaN, NaN, NaN
250mas, J_long, 4.5, NaN, NaN, NaN
250mas, J_long, 5.0, NaN, NaN, NaN
250mas, J_long, 5.5, NaN, NaN, NaN
250mas, J_long, 6.0, 1.6, 270.9, 26764.4
250mas, J_long, 6.5, 1.6, 203.3, 16887.2
250mas, J_long, 7.0, 1.6, 149.4, 10655.1
250mas, J_long, 7.5, 1.6, 107.0, 6723.0
250mas, J_long, 8.0, 2.3, 100.0, 6141.0
250mas, J_long, 8.5, 3.6, 100.0, 6103.4
250mas, J_long, 9.0, 5.7, 100.0, 6033.4
250mas, J_long, 9.5, 8.6, 100.0, 5849.9
250mas, J_long, 10.0, 13.0, 100.0, 5701.0
250mas, J_long, 10.5, 19.7, 100.0, 5660.7
250mas, J_long, 11.0, 30.4, 100.0, 5808.6
250mas, J_long, 11.5, 48.5, 100.0, 6323.3
250mas, J_long, 12.0, 80.8, 100.0, 7457.6
250mas, J_long, 12.5, 140.6, 100.0, 9584.5
250mas, J_long, 13.0, 260.4, 100.0, 13802.8
250mas, H_low, 3.0, NaN, NaN, NaN
250mas, H_low, 3.5, NaN, NaN, NaN
250mas, H_low, 4.0, NaN, NaN, NaN
250mas, H_low, 4.5, NaN, NaN, NaN
250mas, H_low, 5.0, NaN, NaN, NaN
250mas, H_low, 5.5, NaN, NaN, NaN
250mas, H_low, 6.0, NaN, NaN, NaN
250mas, H_low, 6.5, NaN, NaN, NaN
250mas, H_low, 7.0, 1.6, 266.6, 30557.6
250mas, H_low, 7.5, 1.6, 199.3, 19412.6
250mas, H_low, 8.0, 1.6, 145.7, 12380.6
250mas, H_low, 8.5, 1.6, 103.9, 7943.7
250mas, H_low, 9.0, 2.4, 100.0, 7818.0
250mas, H_low, 9.5, 3.9, 100.0, 8194.7
250mas, H_low, 10.0, 6.1, 100.0, 8832.4
250mas, H_low, 10.5, 9.5, 100.0, 9646.4
250mas, H_low, 11.0, 14.7, 100.0, 11255.9
250mas, H_low, 11.5, 23.3, 100.0, 14152.4
250mas, H_low, 12.0, 37.9, 100.0, 19233.8
250mas, H_low, 12.5, 64.6, 100.0, 28755.4
250mas, H_low, 13.0, 116.6, 100.0, 47239.1
250mas, H_short, 3.0, NaN, NaN, NaN
250mas, H_short, 3.5, NaN, NaN, NaN
250mas, H_short, 4.0, NaN, NaN, NaN
250mas, H_short, 4.5, NaN, NaN, NaN
250mas, H_short, 5.0, NaN, NaN, NaN
250mas, H_short, 5.5, NaN, NaN, NaN
250mas, H_short, 6.0, 1.6, 278.9, 29142.9
250mas, H_short, 6.5, 1.6, 209.3, 18459.0
250mas, H_short, 7.0, 1.6, 153.8, 11729.1
250mas, H_short, 7.5, 1.6, 110.2, 7482.8
250mas, H_short, 8.0, 2.2, 100.0, 6777.4
250mas, H_short, 8.5, 3.5, 100.0, 7083.9
250mas, H_short, 9.0, 5.6, 100.0, 7511.2
250mas, H_short, 9.5, 8.5, 100.0, 7984.4
250mas, H_short, 10.0, 12.9, 100.0, 8811.3
250mas, H_short, 10.5, 19.9, 100.0, 10281.3
250mas, H_short, 11.0, 31.0, 100.0, 12864.0
250mas, H_short, 11.5, 50.2, 100.0, 17715.0
250mas, H_short, 12.0, 85.4, 100.0, 26986.0
250mas, H_short, 12.5, 152.3, 100.0, 44589.3
250mas, H_short, 13.0, 290.6, 100.0, 80811.8
250mas, H_middle, 3.0, NaN, NaN, NaN
250mas, H_middle, 3.5, NaN, NaN, NaN
250mas, H_middle, 4.0, NaN, NaN, NaN
250mas, H_middle, 4.5, NaN, NaN, NaN
250mas, H_middle, 5.0, NaN, NaN, NaN
250mas, H_middle, 5.5, NaN, NaN, NaN
250mas, H_middle, 6.0, 1.6, 249.6, 29231.6
250mas, H_middle, 6.5, 1.6, 185.9, 18458.7
250mas, H_middle, 7.0, 1.6, 135.4, 11671.1
250mas, H_middle, 7.5, 1.7, 100.0, 7788.2
250mas, H_middle, 8.0, 2.7, 100.0, 7878.1
250mas, H_middle, 8.5, 4.2, 100.0, 8084.5
250mas, H_middle, 9.0, 6.6, 100.0, 8522.8
250mas, H_middle, 9.5, 9.9, 100.0, 9067.3
250mas, H_middle, 10.0, 15.1, 100.0, 10136.5
250mas, H_middle, 10.5, 23.4, 100.0, 12053.6
250mas, H_middle, 11.0, 36.7, 100.0, 15351.7
250mas, H_middle, 11.5, 59.6, 100.0, 21299.6
250mas, H_middle, 12.0, 102.0, 100.0, 32534.9
250mas, H_middle, 12.5, 183.7, 100.0, 54113.5
250mas, H_middle, 13.0, 352.4, 100.0, 98371.9
250mas, H_long, 3.0, NaN, NaN, NaN
250mas, H_long, 3.5, NaN, NaN, NaN
250mas, H_long, 4.0, NaN, NaN, NaN
250mas, H_long, 4.5, NaN, NaN, NaN
250mas, H_long, 5.0, NaN, NaN, NaN
250mas, H_long, 5.5, NaN, NaN, NaN
250mas, H_long, 6.0, 1.6, 209.3, 25295.5
250mas, H_long, 6.5, 1.6, 154.1, 15960.4
250mas, H_long, 7.0, 1.6, 110.8, 10070.4
250mas, H_long, 7.5, 2.2, 100.0, 8803.8
250mas, H_long, 8.0, 3.5, 100.0, 8994.2
250mas, H_long, 8.5, 5.5, 100.0, 9347.1
250mas, H_long, 9.0, 8.4, 100.0, 9664.2
250mas, H_long, 9.5, 12.7, 100.0, 10274.9
250mas, H_long, 10.0, 19.3, 100.0, 11457.6
250mas, H_long, 10.5, 29.7, 100.0, 13581.3
250mas, H_long, 11.0, 47.1, 100.0, 17494.9
250mas, H_long, 11.5, 78.0, 100.0, 24695.8
250mas, H_long, 12.0, 134.4, 100.0, 37924.8
250mas, H_long, 12.5, 246.5, 100.0, 64183.6
250mas, H_long, 13.0, 480.0, 100.0, 118393.2
250mas, K_low, 3.0, NaN, NaN, NaN
250mas, K_low, 3.5, NaN, NaN, NaN
250mas, K_low, 4.0, NaN, NaN, NaN
250mas, K_low, 4.5, NaN, NaN, NaN
250mas, K_low, 5.0, NaN, NaN, NaN
250mas, K_low, 5.5, NaN, NaN, NaN
250mas, K_low, 6.0, NaN, NaN, NaN
250mas, K_low, 6.5, 1.6, 233.6, 33420.4
250mas, K_low, 7.0, 1.6, 171.9, 21097.7
250mas, K_low, 7.5, 1.6, 123.5, 13322.6
250mas, K_low, 8.0, 2.0, 100.0, 10274.8
250mas, K_low, 8.5, 3.2, 100.0, 10793.8
250mas, K_low, 9.0, 5.5, 100.0, 11530.2
250mas, K_low, 9.5, 9.3, 100.0, 12620.6
250mas, K_low, 10.0, 16.5, 100.0, 14727.9
250mas, K_low, 10.5, 31.4, 100.0, 18861.1
250mas, K_low, 11.0, 64.4, 100.0, 27052.8
250mas, K_low, 11.5, 140.2, 100.0, 42892.9
250mas, K_low, 12.0, 318.7, 100.0, 74529.9
250mas, K_low, 12.5, 744.0, 100.0, 140219.0
250mas, K_low, 13.0, 1000.0, 75.0, 180962.1
250mas, K_short, 3.0, NaN, NaN, NaN
250mas, K_short, 3.5, NaN, NaN, NaN
250mas, K_short, 4.0, NaN, NaN, NaN
250mas, K_short, 4.5, NaN, NaN, NaN
250mas, K_short, 5.0, NaN, NaN, NaN
250mas, K_short, 5.5, 1.6, 275.5, 37023.6
250mas, K_short, 6.0, 1.6, 206.5, 23361.5
250mas, K_short, 6.5, 1.6, 151.5, 14741.2
250mas, K_short, 7.0, 1.6, 108.4, 9302.2
250mas, K_short, 7.5, 2.3, 100.0, 8422.4
250mas, K_short, 8.0, 3.7, 100.0, 8491.9
250mas, K_short, 8.5, 5.8, 100.0, 8542.6
250mas, K_short, 9.0, 9.1, 100.0, 8495.2
250mas, K_short, 9.5, 14.6, 100.0, 8944.4
250mas, K_short, 10.0, 24.4, 100.0, 10069.2
250mas, K_short, 10.5, 43.4, 100.0, 12640.6
250mas, K_short, 11.0, 84.1, 100.0, 18100.0
250mas, K_short, 11.5, 174.8, 100.0, 29243.6
250mas, K_short, 12.0, 385.3, 100.0, 52766.8
250mas, K_short, 12.5, 872.9, 100.0, 102868.4
250mas, K_short, 13.0, 1000.0, 69.7, 105786.2
250mas, K_middle, 3.0, NaN, NaN, NaN
250mas, K_middle, 3.5, NaN, NaN, NaN
250mas, K_middle, 4.0, NaN, NaN, NaN
250mas, K_middle, 4.5, NaN, NaN, NaN
250mas, K_middle, 5.0, NaN, NaN, NaN
250mas, K_middle, 5.5, 1.6, 261.5, 35949.3
250mas, K_middle, 6.0, 1.6, 195.0, 22684.5
250mas, K_middle, 6.5, 1.6, 142.2, 14315.0
250mas, K_middle, 7.0, 1.6, 101.1, 9034.2
250mas, K_middle, 7.5, 2.5, 100.0, 9049.9
250mas, K_middle, 8.0, 4.1, 100.0, 9237.0
250mas, K_middle, 8.5, 6.6, 100.0, 9488.5
250mas, K_middle, 9.0, 10.7, 100.0, 9996.0
250mas, K_middle, 9.5, 18.0, 100.0, 11227.1
250mas, K_middle, 10.0, 32.5, 100.0, 13811.1
250mas, K_middle, 10.5, 63.8, 100.0, 19150.9
250mas, K_middle, 11.0, 134.8, 100.0, 29863.8
250mas, K_middle, 11.5, 301.3, 100.0, 51743.9
250mas, K_middle, 12.0, 696.6, 100.0, 97746.3
250mas, K_middle, 12.5, 1000.0, 77.8, 120495.1
250mas, K_middle, 13.0, 1000.0, 50.0, 107992.4
250mas, K_long, 3.0, NaN, NaN, NaN
250mas, K_long, 3.5, NaN, NaN, NaN
250mas, K_long, 4.0, NaN, NaN, NaN
250mas, K_long, 4.5, NaN, NaN, NaN
250mas, K_long, 5.0, NaN, NaN, NaN
250mas, K_long, 5.5, 1.6, 217.9, 34949.4
250mas, K_long, 6.0, 1.6, 159.9, 22056.0
250mas, K_long, 6.5, 1.6, 114.6, 13920.8
250mas, K_long, 7.0, 2.2, 100.0, 11846.8
250mas, K_long, 7.5, 3.5, 100.0, 12269.5
250mas, K_long, 8.0, 5.9, 100.0, 12851.4
250mas, K_long, 8.5, 9.8, 100.0, 13736.6
250mas, K_long, 9.0, 17.4, 100.0, 15866.7
250mas, K_long, 9.5, 33.3, 100.0, 20186.2
250mas, K_long, 10.0, 69.7, 100.0, 28678.8
250mas, K_long, 10.5, 155.2, 100.0, 44807.3
250mas, K_long, 11.0, 360.1, 100.0, 76090.4
250mas, K_long, 11.5, 855.5, 100.0, 138967.5
250mas, K_long, 12.0, 1000.0, 69.4, 131609.9
250mas, K_long, 12.5, 1000.0, 44.3, 112153.4
250mas, K_long, 13.0, 1000.0, 28.1, 99877.2