! READING Filter ! Absolute filter transmission measurement at cold using a FTS ! lambda (microns) absolute transmission (%) 8.85000 0.0669100 8.85601 0.0454337 8.86201 0.0185659 8.86802 -0.0124951 8.87402 -0.0346866 8.88003 -0.0371327 8.88604 -0.0265231 8.89204 -0.0192852 8.89805 -0.0161514 8.90405 -0.00646340 8.91006 0.00303257 8.91607 -0.000565057 8.92207 -0.00469204 8.92808 0.00821038 8.93408 0.0270033 8.94009 0.0332100 8.94610 0.0314088 8.95210 0.0305857 8.95811 0.0244746 8.96411 0.0118181 8.97012 0.00836586 8.97613 0.0197360 8.98213 0.0254969 8.98814 0.00526666 8.99414 -0.0319017 9.00015 -0.0586433 9.00616 -0.0585468 9.01216 -0.0361462 9.01817 -0.00717433 9.02417 0.0119319 9.03018 0.0119603 9.03619 -0.00382380 9.04219 -0.0246973 9.04820 -0.0360398 9.05420 -0.0261627 9.06021 -0.000794847 9.06622 0.0211639 9.07222 0.0251244 9.07823 0.00736672 9.08423 -0.0253871 9.09024 -0.0550862 9.09625 -0.0589729 9.10225 -0.0305985 9.10826 0.0103352 9.11426 0.0339155 9.12027 0.0258262 9.12628 0.00103634 9.13228 -0.0104235 9.13829 0.00461871 9.14429 0.0243977 9.15030 0.0191376 9.15631 -0.00596051 9.16231 -0.0195281 9.16832 -0.00918103 9.17432 0.0117420 9.18033 0.0296560 9.18634 0.0379013 9.19234 0.0364976 9.19835 0.0357089 9.20435 0.0430904 9.21036 0.0479323 9.21637 0.0356671 9.22237 0.00835365 9.22838 -0.0208495 9.23438 -0.0391060 9.24039 -0.0402610 9.24640 -0.0284791 9.25240 -0.0156151 9.25841 -0.0154610 9.26441 -0.0388413 9.27042 -0.0807961 9.27643 -0.113460 9.28243 -0.114830 9.28844 -0.0943682 9.29445 -0.0738946 9.30045 -0.0591661 9.30646 -0.0457124 9.31246 -0.0302894 9.31847 -0.0101022 9.32448 0.00848208 9.33048 0.00609343 9.33649 -0.0215151 9.34249 -0.0464057 9.34850 -0.0449011 9.35450 -0.0312683 9.36051 -0.0313875 9.36652 -0.0429013 9.37252 -0.0464580 9.37853 -0.0329548 9.38453 0.00352067 9.39054 0.0644566 9.39655 0.123201 9.40255 0.134680 9.40856 0.0924795 9.41457 0.0364711 9.42057 -0.00270788 9.42658 -0.0320976 9.43258 -0.0556775 9.43859 -0.0485456 9.44460 0.00232725 9.45060 0.0613944 9.45661 0.0781758 9.46261 0.0484325 9.46862 0.0112056 9.47462 -0.00359957 9.48063 -0.000578437 9.48664 0.00618689 9.49264 0.0162000 9.49865 0.0343973 9.50465 0.0564508 9.51066 0.0678421 9.51667 0.0574744 9.52267 0.0329486 9.52868 0.0197082 9.53469 0.0320029 9.54069 0.0509592 9.54670 0.0427238 9.55270 0.00358208 9.55871 -0.0358917 9.56472 -0.0510114 9.57072 -0.0527740 9.57673 -0.0612933 9.58273 -0.0703552 9.58874 -0.0631912 9.59475 -0.0450836 9.60075 -0.0300577 9.60676 -0.0111164 9.61276 0.0166098 9.61877 0.0239516 9.62477 -0.00935291 9.63078 -0.0414742 9.63679 -0.0158332 9.64279 0.0550323 9.64880 0.108626 9.65481 0.119928 9.66081 0.108968 9.66682 0.0862597 9.67282 0.0472534 9.67883 0.00844596 9.68484 0.000467359 9.69084 0.0246204 9.69685 0.0468574 9.70285 0.0338975 9.70886 -0.0124465 9.71487 -0.0623391 9.72087 -0.0943173 9.72688 -0.119914 9.73288 -0.151938 9.73889 -0.164746 9.74489 -0.121334 9.75090 -0.0318463 9.75691 0.0535335 9.76291 0.103507 9.76892 0.121773 9.77493 0.114369 9.78093 0.0782481 9.78694 0.0248101 9.79294 -0.0113990 9.79895 0.00149719 9.80496 0.0610898 9.81096 0.131150 9.81697 0.174087 9.82297 0.185793 9.82898 0.186565 9.83499 0.186903 9.84099 0.175069 9.84700 0.141249 9.85300 0.0983859 9.85901 0.0696185 9.86502 0.0667643 9.87102 0.0796656 9.87703 0.0904799 9.88303 0.0962661 9.88904 0.106549 9.89505 0.123537 9.90105 0.138300 9.90706 0.145929 9.91306 0.148697 9.91907 0.151077 9.92508 0.160802 9.93108 0.188474 9.93709 0.230853 9.94309 0.256440 9.94910 0.225401 9.95511 0.145137 9.96111 0.0867011 9.96712 0.110539 9.97312 0.214981 9.97913 0.338613 9.98514 0.431764 9.99114 0.472548 9.99715 0.464308 10.0032 0.467950 10.0092 0.601360 10.0152 0.919866 10.0212 1.39429 10.0272 2.05755 10.0332 2.98890 10.0392 3.99598 10.0452 4.49036 10.0512 4.00654 10.0572 2.77610 10.0632 1.56001 10.0692 0.885553 10.0752 0.702455 10.0812 0.721250 10.0872 0.767196 10.0932 0.803867 10.0992 0.823917 10.1053 0.834931 10.1113 0.879938 10.1173 0.980830 10.1233 1.10446 10.1293 1.19663 10.1353 1.23660 10.1413 1.24344 10.1473 1.26048 10.1533 1.31000 10.1593 1.38945 10.1653 1.47920 10.1713 1.56465 10.1773 1.64332 10.1833 1.71712 10.1893 1.78684 10.1953 1.85678 10.2014 1.93729 10.2074 2.03842 10.2134 2.16330 10.2194 2.30696 10.2254 2.45985 10.2314 2.60979 10.2374 2.75026 10.2434 2.88514 10.2494 3.02788 10.2554 3.18859 10.2614 3.36311 10.2674 3.54202 10.2734 3.72498 10.2794 3.92423 10.2854 4.14515 10.2914 4.37761 10.2974 4.60963 10.3035 4.84541 10.3095 5.10155 10.3155 5.38606 10.3215 5.68946 10.3275 5.99494 10.3335 6.29512 10.3395 6.59588 10.3455 6.90782 10.3515 7.23732 10.3575 7.58676 10.3635 7.95397 10.3695 8.33714 10.3755 8.73401 10.3815 9.14497 10.3875 9.57027 10.3935 10.0105 10.3995 10.4706 10.4056 10.9576 10.4116 11.4779 10.4176 12.0268 10.4236 12.5957 10.4296 13.1780 10.4356 13.7774 10.4416 14.3972 10.4476 15.0337 10.4536 15.6778 10.4596 16.3239 10.4656 16.9774 10.4716 17.6492 10.4776 18.3465 10.4836 19.0660 10.4896 19.7992 10.4956 20.5411 10.5017 21.2941 10.5077 22.0620 10.5137 22.8441 10.5197 23.6362 10.5257 24.4386 10.5317 25.2558 10.5377 26.0911 10.5437 26.9384 10.5497 27.7853 10.5557 28.6223 10.5617 29.4491 10.5677 30.2731 10.5737 31.1019 10.5797 31.9394 10.5857 32.7840 10.5917 33.6329 10.5977 34.4832 10.6038 35.3321 10.6098 36.1746 10.6158 37.0031 10.6218 37.8124 10.6278 38.6027 10.6338 39.3793 10.6398 40.1485 10.6458 40.9131 10.6518 41.6732 10.6578 42.4270 10.6638 43.1702 10.6698 43.8961 10.6758 44.5983 10.6818 45.2759 10.6878 45.9363 10.6938 46.5935 10.6999 47.2593 10.7059 47.9388 10.7119 48.6286 10.7179 49.3231 10.7239 50.0159 10.7299 50.7007 10.7359 51.3699 10.7419 52.0200 10.7479 52.6535 10.7539 53.2795 10.7599 53.9049 10.7659 54.5300 10.7719 55.1468 10.7779 55.7450 10.7839 56.3171 10.7899 56.8633 10.7959 57.3926 10.8020 57.9176 10.8080 58.4448 10.8140 58.9693 10.8200 59.4810 10.8260 59.9736 10.8320 60.4466 10.8380 60.9016 10.8440 61.3385 10.8500 61.7556 10.8560 62.1511 10.8620 62.5279 10.8680 62.8936 10.8740 63.2594 10.8800 63.6331 10.8860 64.0175 10.8920 64.4070 10.8980 64.7917 10.9041 65.1622 10.9101 65.5162 10.9161 65.8579 10.9221 66.1939 10.9281 66.5285 10.9341 66.8643 10.9401 67.2035 10.9461 67.5461 10.9521 67.8883 10.9581 68.2226 10.9641 68.5426 10.9701 68.8461 10.9761 69.1357 10.9821 69.4150 10.9881 69.6865 10.9941 69.9505 11.0002 70.2088 11.0062 70.4636 11.0122 70.7157 11.0182 70.9618 11.0242 71.2007 11.0302 71.4360 11.0362 71.6744 11.0422 71.9182 11.0482 72.1650 11.0542 72.4119 11.0602 72.6594 11.0662 72.9108 11.0722 73.1670 11.0782 73.4246 11.0842 73.6782 11.0902 73.9249 11.0962 74.1681 11.1023 74.4160 11.1083 74.6764 11.1143 74.9523 11.1203 75.2395 11.1263 75.5283 11.1323 75.8082 11.1383 76.0753 11.1443 76.3356 11.1503 76.6013 11.1563 76.8809 11.1623 77.1730 11.1683 77.4694 11.1743 77.7633 11.1803 78.0537 11.1863 78.3429 11.1923 78.6294 11.1983 78.9070 11.2044 79.1701 11.2104 79.4185 11.2164 79.6586 11.2224 79.8981 11.2284 80.1423 11.2344 80.3915 11.2404 80.6433 11.2464 80.8937 11.2524 81.1401 11.2584 81.3810 11.2644 81.6161 11.2704 81.8436 11.2764 82.0598 11.2824 82.2608 11.2884 82.4474 11.2944 82.6264 11.3005 82.8076 11.3065 82.9940 11.3125 83.1784 11.3185 83.3461 11.3245 83.4881 11.3305 83.6082 11.3365 83.7245 11.3425 83.8546 11.3485 84.0079 11.3545 84.1772 11.3605 84.3463 11.3665 84.4955 11.3725 84.6114 11.3785 84.6916 11.3845 84.7407 11.3905 84.7692 11.3965 84.7847 11.4026 84.7940 11.4086 84.7972 11.4146 84.7899 11.4206 84.7604 11.4266 84.6965 11.4326 84.5901 11.4386 84.4424 11.4446 84.2621 11.4506 84.0595 11.4566 83.8414 11.4626 83.6101 11.4686 83.3663 11.4746 83.1117 11.4806 82.8508 11.4866 82.5928 11.4926 82.3538 11.4986 82.1544 11.5047 82.0139 11.5107 81.9406 11.5167 81.9294 11.5227 81.9646 11.5287 82.0283 11.5347 82.1082 11.5407 82.1965 11.5467 82.2903 11.5527 82.3852 11.5587 82.4818 11.5647 82.5811 11.5707 82.6871 11.5767 82.8041 11.5827 82.9353 11.5887 83.0842 11.5947 83.2522 11.6008 83.4396 11.6068 83.6421 11.6128 83.8529 11.6188 84.0645 11.6248 84.2712 11.6308 84.4669 11.6368 84.6455 11.6428 84.8015 11.6488 84.9319 11.6548 85.0389 11.6608 85.1284 11.6668 85.2058 11.6728 85.2711 11.6788 85.3186 11.6848 85.3399 11.6908 85.3293 11.6968 85.2880 11.7029 85.2249 11.7089 85.1553 11.7149 85.0920 11.7209 85.0416 11.7269 85.0021 11.7329 84.9693 11.7389 84.9396 11.7449 84.9125 11.7509 84.8920 11.7569 84.8809 11.7629 84.8785 11.7689 84.8788 11.7749 84.8761 11.7809 84.8672 11.7869 84.8522 11.7929 84.8348 11.7989 84.8184 11.8050 84.8032 11.8110 84.7851 11.8170 84.7582 11.8230 84.7182 11.8290 84.6641 11.8350 84.5990 11.8410 84.5284 11.8470 84.4558 11.8530 84.3780 11.8590 84.2888 11.8650 84.1840 11.8710 84.0654 11.8770 83.9408 11.8830 83.8211 11.8890 83.7113 11.8950 83.6070 11.9011 83.5010 11.9071 83.3921 11.9131 83.2881 11.9191 83.2056 11.9251 83.1645 11.9311 83.1734 11.9371 83.2257 11.9431 83.3047 11.9491 83.3901 11.9551 83.4627 11.9611 83.5101 11.9671 83.5303 11.9731 83.5305 11.9791 83.5211 11.9851 83.5108 11.9911 83.5035 11.9971 83.4958 12.0032 83.4802 12.0092 83.4541 12.0152 83.4215 12.0212 83.3887 12.0272 83.3610 12.0332 83.3391 12.0392 83.3174 12.0452 83.2929 12.0512 83.2674 12.0572 83.2456 12.0632 83.2321 12.0692 83.2266 12.0752 83.2215 12.0812 83.2089 12.0872 83.1861 12.0932 83.1561 12.0992 83.1258 12.1053 83.1042 12.1113 83.0942 12.1173 83.0936 12.1233 83.0976 12.1293 83.1004 12.1353 83.0965 12.1413 83.0798 12.1473 83.0453 12.1533 82.9905 12.1593 82.9175 12.1653 82.8338 12.1713 82.7533 12.1773 82.6893 12.1833 82.6458 12.1893 82.6191 12.1953 82.5990 12.2014 82.5719 12.2074 82.5314 12.2134 82.4795 12.2194 82.4208 12.2254 82.3593 12.2314 82.2960 12.2374 82.2261 12.2434 82.1468 12.2494 82.0584 12.2554 81.9635 12.2614 81.8672 12.2674 81.7715 12.2734 81.6762 12.2794 81.5803 12.2854 81.4829 12.2914 81.3854 12.2974 81.2875 12.3035 81.1863 12.3095 81.0755 12.3155 80.9471 12.3215 80.7949 12.3275 80.6172 12.3335 80.4184 12.3395 80.2044 12.3455 79.9817 12.3515 79.7566 12.3575 79.5305 12.3635 79.3020 12.3695 79.0684 12.3755 78.8251 12.3815 78.5708 12.3875 78.3076 12.3935 78.0395 12.3995 77.7704 12.4056 77.5032 12.4116 77.2377 12.4176 76.9723 12.4236 76.7054 12.4296 76.4358 12.4356 76.1631 12.4416 75.8876 12.4476 75.6102 12.4536 75.3325 12.4596 75.0573 12.4656 74.7862 12.4716 74.5162 12.4776 74.2420 12.4836 73.9558 12.4896 73.6504 12.4956 73.3269 12.5017 72.9912 12.5077 72.6533 12.5137 72.3255 12.5197 72.0152 12.5257 71.7217 12.5317 71.4412 12.5377 71.1659 12.5437 70.8874 12.5497 70.6037 12.5557 70.3160 12.5617 70.0288 12.5677 69.7510 12.5737 69.4859 12.5797 69.2343 12.5857 68.9945 12.5917 68.7620 12.5977 68.5360 12.6038 68.3180 12.6098 68.1109 12.6158 67.9216 12.6218 67.7554 12.6278 67.6142 12.6338 67.4977 12.6398 67.3985 12.6458 67.3069 12.6518 67.2173 12.6578 67.1268 12.6638 67.0408 12.6698 66.9691 12.6758 66.9173 12.6818 66.8886 12.6878 66.8763 12.6938 66.8664 12.6999 66.8491 12.7059 66.8160 12.7119 66.7706 12.7179 66.7253 12.7239 66.6910 12.7299 66.6791 12.7359 66.6874 12.7419 66.7060 12.7479 66.7232 12.7539 66.7235 12.7599 66.7023 12.7659 66.6580 12.7719 66.5920 12.7779 66.5103 12.7839 66.4077 12.7899 66.2791 12.7959 66.1176 12.8020 65.9097 12.8080 65.6514 12.8140 65.3402 12.8200 64.9746 12.8260 64.5571 12.8320 64.0845 12.8380 63.5535 12.8440 62.9594 12.8500 62.2925 12.8560 61.5438 12.8620 60.7068 12.8680 59.7756 12.8740 58.7524 12.8800 57.6446 12.8860 56.4607 12.8920 55.2093 12.8980 53.8938 12.9041 52.5143 12.9101 51.0665 12.9161 49.5533 12.9221 47.9810 12.9281 46.3581 12.9341 44.7052 12.9401 43.0368 12.9461 41.3627 12.9521 39.6907 12.9581 38.0198 12.9641 36.3483 12.9701 34.6771 12.9761 33.0081 12.9821 31.3546 12.9881 29.7278 12.9941 28.1434 13.0002 26.6173 13.0062 25.1575 13.0122 23.7692 13.0182 22.4513 13.0242 21.1989 13.0302 20.0073 13.0362 18.8691 13.0422 17.7800 13.0482 16.7378 13.0542 15.7410 13.0602 14.7922 13.0662 13.8944 13.0722 13.0497 13.0782 12.2606 13.0842 11.5250 13.0902 10.8399 13.0962 10.2006 13.1023 9.60355 13.1083 9.04530 13.1143 8.52334 13.1203 8.03647 13.1263 7.57748 13.1323 7.14163 13.1383 6.72454 13.1443 6.32144 13.1503 5.93480 13.1563 5.57023 13.1623 5.23075 13.1683 4.91785 13.1743 4.63239 13.1803 4.36479 13.1863 4.11328 13.1923 3.87626 13.1983 3.65138 13.2044 3.44375 13.2104 3.25442 13.2164 3.08223 13.2224 2.92532 13.2284 2.78075 13.2344 2.64401 13.2404 2.51551 13.2464 2.39504 13.2524 2.28240 13.2584 2.17794 13.2644 2.07915 13.2704 1.98381 13.2764 1.88993 13.2824 1.79740 13.2884 1.70633 13.2944 1.61882 13.3005 1.53473 13.3065 1.45357 13.3125 1.37313 13.3185 1.29097 13.3245 1.20616 13.3305 1.11835 13.3365 1.03068 13.3425 0.945382 13.3485 0.866061 13.3545 0.795698 13.3605 0.735239 13.3665 0.685311 13.3725 0.645067 13.3785 0.613404 13.3845 0.588577 13.3905 0.568241 13.3965 0.550962 13.4026 0.534844 13.4086 0.518941 13.4146 0.502513 13.4206 0.484684 13.4266 0.464065 13.4326 0.439349 13.4386 0.408545 13.4446 0.371223 13.4506 0.328905 13.4566 0.283711 13.4626 0.242843 13.4686 0.209929 13.4746 0.190229 13.4806 0.184589 13.4866 0.190690 13.4926 0.204070 13.4986 0.216235 13.5047 0.223516 13.5107 0.220443 13.5167 0.208695 13.5227 0.190529 13.5287 0.171597 13.5347 0.157922 13.5407 0.151825 13.5467 0.155265 13.5527 0.163517 13.5587 0.173499 13.5647 0.177102 13.5707 0.170722 13.5767 0.152069 13.5827 0.122397 13.5887 0.0870690 13.5947 0.0502035 13.6008 0.0201807 13.6068 -0.000762278 13.6128 -0.00981015 13.6188 -0.00897543 13.6248 -0.00104746 13.6308 0.0103295 13.6368 0.0204026 13.6428 0.0279463 13.6488 0.0313796 13.6548 0.0324400 13.6608 0.0319213 13.6668 0.0316973 13.6728 0.0316894 13.6788 0.0318402 13.6848 0.0305611 13.6908 0.0274539 13.6968 0.0220496 13.7029 0.0156874 13.7089 0.00943484 13.7149 0.00481070 13.7209 0.00185251 13.7269 -0.000193432 13.7329 -0.00316132 13.7389 -0.00900956 13.7449 -0.0183284 13.7509 -0.0306079 13.7569 -0.0433704 13.7629 -0.0549533 13.7689 -0.0620011 13.7749 -0.0648374 13.7809 -0.0631988 13.7869 -0.0610948 13.7929 -0.0602457 13.7989 -0.0645569 13.8050 -0.0741764 13.8110 -0.0892067 13.8170 -0.105942 13.8230 -0.121798 13.8290 -0.134053 13.8350 -0.141398 13.8410 -0.144308 13.8470 -0.144121 13.8530 -0.141528 13.8590 -0.136538 13.8650 -0.126808 13.8710 -0.110444 13.8770 -0.0853876 13.8830 -0.0533276 13.8890 -0.0176527 13.8950 0.0155793 13.9011 0.0381866 13.9071 0.0468737 13.9131 0.0382842 13.9191 0.0163274 13.9251 -0.0165602 13.9311 -0.0512162 13.9371 -0.0848403 13.9431 -0.111609 13.9491 -0.130772 13.9551 -0.141447 13.9611 -0.144909 13.9671 -0.142164 13.9731 -0.134494 13.9791 -0.123221 13.9851 -0.109066 13.9911 -0.0940275 13.9971 -0.0803160 14.0032 -0.0698018 14.0092 -0.0651913 14.0152 -0.0663340 14.0212 -0.0729588 14.0272 -0.0812138 14.0332 -0.0891811 14.0392 -0.0918124 14.0452 -0.0888370 14.0512 -0.0788536 14.0572 -0.0652175 14.0632 -0.0492311 14.0692 -0.0359433 14.0752 -0.0266499 14.0812 -0.0237339 14.0872 -0.0271908 14.0932 -0.0369291 14.0992 -0.0513643 14.1053 -0.0685186 14.1113 -0.0866270 14.1173 -0.101469 14.1233 -0.111657 14.1293 -0.113214 14.1353 -0.106973 14.1413 -0.0923403 14.1473 -0.0751652 14.1533 -0.0575919 14.1593 -0.0471152 14.1653 -0.0444967 14.1713 -0.0522458 14.1773 -0.0654551 14.1833 -0.0822831 14.1893 -0.0954456 14.1953 -0.103798 14.2014 -0.104568 14.2074 -0.100972 14.2134 -0.0940519 14.2194 -0.0886404 14.2254 -0.0852748 14.2314 -0.0856070 14.2374 -0.0879569 14.2434 -0.0918838 14.2494 -0.0956137 14.2554 -0.0994377 14.2614 -0.103437 14.2674 -0.108480 14.2734 -0.114905 14.2794 -0.121992 14.2854 -0.129031 14.2914 -0.134401 14.2974 -0.137438 14.3035 -0.137474 14.3095 -0.135283 14.3155 -0.131273 14.3215 -0.127010 14.3275 -0.123106 14.3335 -0.120391 14.3395 -0.119016 14.3455 -0.119035 14.3515 -0.119985 14.3575 -0.121477 14.3635 -0.122963 14.3695 -0.123228 14.3755 -0.121633 14.3815 -0.117511 14.3875 -0.111014 14.3935 -0.102774 14.3995 -0.0938140 14.4056 -0.0851975 14.4116 -0.0777805 14.4176 -0.0719041 14.4236 -0.0681658 14.4296 -0.0666768 14.4356 -0.0678544 14.4416 -0.0713669 14.4476 -0.0772575 14.4536 -0.0839300 14.4596 -0.0910277 14.4656 -0.0972556 14.4716 -0.103775 14.4776 -0.111592 14.4836 -0.125278 14.4896 -0.147478 14.4956 -0.181517 14.5017 -0.227132 14.5077 -0.277703 14.5137 -0.326955 14.5197 -0.362911 14.5257 -0.379709 14.5317 -0.371230 14.5377 -0.343089 14.5437 -0.296974 14.5497 -0.247261 14.5557 -0.197247 14.5617 -0.157172 14.5677 -0.126714 14.5737 -0.108034 14.5797 -0.0969075 14.5857 -0.0924767 14.5917 -0.0901289 14.5977 -0.0894103 14.6038 -0.0881166 14.6098 -0.0866271 14.6158 -0.0846171 14.6218 -0.0832409 14.6278 -0.0827422 14.6338 -0.0852141 14.6398 -0.0908820 14.6458 -0.100930 14.6518 -0.114216 14.6578 -0.129605 14.6638 -0.144316 14.6698 -0.156399 14.6758 -0.164457 14.6818 -0.167970 14.6878 -0.168826 14.6938 -0.167514 14.6999 -0.166584 14.7059 -0.165633 14.7119 -0.165092 14.7179 -0.163389 14.7239 -0.159806 14.7299 -0.153166 14.7359 -0.143128 14.7419 -0.131184 14.7479 -0.117810 14.7539 -0.105649 14.7599 -0.0947970 14.7659 -0.0864921 14.7719 -0.0793922 14.7779 -0.0728859 14.7839 -0.0659729 14.7899 -0.0581363 14.7959 -0.0511936 14.8020 -0.0456757 14.8080 -0.0465187 14.8140 -0.0542402 14.8200 -0.0727379 14.8260 -0.0993161 14.8320 -0.133466 14.8380 -0.168033 14.8440 -0.200212 14.8500 -0.221860