Use Case: Set Crystal
Temperature
Description:
Set new setpoint to the Crystal Temperature controller
Role(s)/Actor(s):
Primary: PRIMA Metrology Control System
Secondary: Crystal Temperature controller
Priority: Critical
Performance: 100msec
Frequency: At any time
Preconditions:
- Crystal Temperature controller is ONLINE
Basic Course:
- Send command SETTEMP
crystal,<temperature> to the Light Source Stabilization sub-system
- Light Source Stabilization sub-system sets the new setpoint
in the Crystal Temperature controller
- Light Source Stabilization sub-system sends OK/ERROR reply
Postconditions:
- the Crystal Temperature controller regulates on the new
temperature setpoint
Issues to be Determined or
Resolved: Temperature regulation bandwidth
Notes:
Last modified: Tue Jan 21 13:37:50 MET 2003