AMBER trending system: HEALTH CHECK report
Last update: 2012-05-25T18:18:58 (UT)
| now: 2012-05-26T05:16:45 (UT)
HELP USERS-GUIDE MORE
same group: P2VM_MK P2VM_MHJ
General news: 2012-05-24: The HC monitors for OMEGACAM, VIRCAM and HAWKI are back. Population with current data is in progress.
AMBER news:
Report news:  
DATE*: [?] 2012-05-19
report | NR
2012-05-20
report | NR
2012-05-21
report | NR
2012-05-22
report | NR
2012-05-23
report | NR
2012-05-24
report | NR
2012-05-25
report | NR
P...
Product quality:
products products products products products products products
  last OPSLOG data:
2012-05-11*

monitor

scores&comments | history ... | plot tutorial ... | contact                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB yes (1) MEAN 0.8729 NONE VAL0.75,1 11 meas_int_Vis_base12 this | last_yr | all VIS12_for_MK2.1
2 QC1DB yes (1) MEAN 0.84758 NONE VAL0.75,1 11 meas_int_Vis_base23 this | last_yr | all VIS23_for_MK2.1
3 QC1DB yes (1) MEAN 0.77302 NONE VAL0.65,1 11 meas_int_Vis_base31 this | last_yr | all VIS31_for_MK2.1
4 QC1DB no MEAN 0.91335 NONE VAL0.8,1 9 meas_int_Vis_base12 this | last_yr | all VIS12_for_MK2.3
5 QC1DB no MEAN 0.80747 NONE VAL0.7,1 9 meas_int_Vis_base23 this | last_yr | all VIS23_for_MK2.3
6 QC1DB no MEAN 0.7554 NONE VAL0.65,1 9 meas_int_Vis_base31 this | last_yr | all VIS31_for_MK2.3
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate that OPSLOG data are included
Plot 1
scores: 4|
data source:amber_p2vm
(QC1 database)
dataset:meas_int_Vis_base12
mean:0.8729NONE
fixed thresholds:0.75...1.0NONE
N_data plotted:11
[click on plot for closeup]
Plot 2
scores: 4|
data source:amber_p2vm
(QC1 database)
dataset:meas_int_Vis_base23
mean:0.84758NONE
fixed thresholds:0.75...1.0NONE
N_data plotted:11
[click on plot for closeup]
Plot 3
scores: 4|
data source:amber_p2vm
(QC1 database)
dataset:meas_int_Vis_base31
mean:0.77302NONE
fixed thresholds:0.65...1.0NONE
N_data plotted:11
[click on plot for closeup]
Plot 4
scores: 3|
data source:amber_p2vm
(QC1 database)
dataset:meas_int_Vis_base12
mean:0.91335NONE
fixed thresholds:0.8...1.0NONE
N_data plotted:9
[click on plot for closeup]
Plot 5
scores: 3|
data source:amber_p2vm
(QC1 database)
dataset:meas_int_Vis_base23
mean:0.80747NONE
fixed thresholds:0.7...1.0NONE
N_data plotted:9
[click on plot for closeup]
Plot 6
scores: 3|
data source:amber_p2vm
(QC1 database)
dataset:meas_int_Vis_base31
mean:0.7554NONE
fixed thresholds:0.65...1.0NONE
N_data plotted:9
[click on plot for closeup]
This plot

The P2VM (Pixel to Visibility Matrix) is used to calibrate the science data. The pipeline product provides also some QC parameters which are used to monitor the Instrumental transfer function and the offset between the photometric beams.
 


General information

Click on any of the plots to see a close-up version.

If applicable, the latest values from Paranal ops logs are plotted as blue dots. More information about those values, including a download option, is available in the OPS column.

The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines