[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
SINFONI trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2019-06-28T05:01:11 (UT)
  | now: 2024-03-19T07:32:07 (UT) muc04 QC pipeline: sinfo-3.2.5 (installed 2019-05-09)
same group: lamp_eff   lamp_badpix lamp_off lamp_fpn1 lamp_fpn2 vignetting_check_sl1 vignetting_check_sl32
close window history: 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018   2019   HEALTH FULL
  ... ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 oQC1DB MEDIAN 0.0399 ADU VAL0.00,0.16 69 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): J-band ALL camera scales
(this FULL data set is scored)
1 QC1DB none   ADU none  34 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): J-band/250 mas scale
1 QC1DB none   ADU none  17 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): J-band/100 mas scale
1 QC1DB none   ADU none  18 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): J-band/ 25 mas scale

2 oQC1DB MEDIAN 0.0344 ADU VAL0.00,0.12 73 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): H-band ALL camera scales
(this FULL data set is scored)
2 QC1DB none   ADU none  33 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): H-band/250 mas scale
2 QC1DB none   ADU none  22 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): H-band/100 mas scale
2 QC1DB none   ADU none  18 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): H-band/ 25 mas scale

3 oQC1DB MEDIAN 0.0272 ADU VAL0.00,0.135 105 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): K-band ALL camera scales
(this FULL data set is scored)
3 QC1DB none   ADU none  46 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): K-band at the 250 mas camera scale
3 QC1DB none   ADU none  28 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): K-band at the 100 mas camera scale
3 QC1DB none   ADU none  31 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): K-band at the 25 mas camera scale

4 oQC1DB MEDIAN 0.0444 ADU VAL0.00,0.12 77 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): H+K-band ALL camera scales
(this FULL data set is scored)
4 QC1DB none   ADU none  30 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): H+K-band at the 250 mas camera scale
4 QC1DB none   ADU none  20 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): H+K-band at the 100 mas camera scale
4 QC1DB none   ADU none  27 qc_lflat_fpn2 this | last_yr | all fixed pattern noise (region 2): H+K-band at the 25 mas camera scale
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: 4|
data source:sinfoni_flat
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_lflat_fpn2o
median:0.0399ADU
fixed thresholds:0.0...0.16ADU
N_data plotted:69
[click plot for closeup]
Plot 2
scores: 7|
data source:sinfoni_flat
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_lflat_fpn2o
median:0.0344ADU
fixed thresholds:0.0...0.12ADU
N_data plotted:73
[click plot for closeup]
Plot 3
scores: 10|
data source:sinfoni_flat
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_lflat_fpn2o
median:0.0272ADU
fixed thresholds:0.0...0.135ADU
N_data plotted:105
[click plot for closeup]
Plot 4
scores: 6|
data source:sinfoni_flat
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_lflat_fpn2o
median:0.0444ADU
fixed thresholds:0.0...0.12ADU
N_data plotted:77
[click plot for closeup]
This plot

The FPN is calculated over 2 windows:

FPN1: over the central region of the detector(X: 512-1536 Y: 512-1536
FPN2: over the area of a single slitlet (X: 1360-1400 Y: 1000-1200)

The area where FPN2 is computed was shifted by 10 pixels after the intervention which took place second part of 2013.

Remark: For H+K the area for FPN2 contains some lines, which causes a correlation with humidity  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up